User manual
NIBE F750 Exhaust air heat pump LE K UHB GB 1702-3 331472
-
Quick guide
Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation of the button functions can be found on page 14. How to scroll through menus and make different settings is described on page 18. Set the indoor climate 2X The mode for…
-
Table of Contents
1 Important information 4 Installation data Safety information Serial number F750 – An excellent choice The heat pump – the heart of the house 10 Heat pump function Contact with F750 Maintenance of F750 F750 – at your service 33 Set the indoor climate Set the hot water capacity Get information…
-
1 Important information
Installation data Product F750 Serial number Installation date Installer No. Name Fact- Set ory settings 1.1 1.9.1 1.9.3 temperature (heating curve offset) heating curve (curve slope) min. flow line temp. 5 20 5.1.5 ventilation 75% -1 (fan speed, normal mode) ✔ Accessories Extra shunt ECS 40/41 Room…
-
Safety information
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards…
-
Symbols
NOTE This symbol indicates danger to machine or person. Caution This symbol indicates important information about what you should observe when maintaining your installation. TIP This symbol indicates tips on how to facilitate using the product. 6 Chapter 1 | Important information NIBE F750
-
Marking
F750 is CE marked and fulfils IP21. The CE marking means that NIBE ensures that the product meets all regulations that are placed on it based on relevant EU directives. The CE mark is obligatory for most products sold in the EU, regardless where they are made. IP21 means that objects with a diameter…
-
Serial number
The serial number can be found at the bottom right of the front cover and in the info menu (menu 3.1). Serial number Caution You need the product's (14 digit) serial number for servicing and support. 8 Chapter 1 | Important information NIBE F750
-
F750 is part of a new generation of heat pumps, which have been introduced to supply your home with inexpensive and environmentally friendly heating. Heat production is safe and economical with integrated hot water heater, immersion heater, circulation pump and control system. The heat pump can be…
-
2 The heat pump – the heart of
-
Heat pump function
An exhaust air heat pump makes use of the heat in the building's ventilation air to heat up the accommodation. The conversion of the ventilation air's energy to accommodation heating is done in three different circuits. From the outgoing ventilation air (1), free heating energy is retrieved from the…
-
I
The heating medium passes the heat pump's integrated buffer vessel whereupon the temperature is equalised. It is then transported to the heating system of the house. The temperatures are only examples and may vary between different installations and time of year. 12 Chapter 2 | The heat pump – the…
-
Contact with F750
External information When the heat pump door is closed, information can be received via an information window and a status lamp. Information window Status lamp Information window The information window shows part of the display that is on the display unit (located behind the door to the heat pump).…
-
Display unit
A Display INDOOR CLIMATE HOT WATER B Status lamp HEAT PUMP INFO C OK button D Back button E Control knob F Switch F750 G USB port There is a display unit behind the heat pump door, which is used to communicate with F750. Here you: ■ switch on, switch off or set the heat pump in emergency mode. ■…
-
C
OK button The OK button is used to: ■ confirm selections of sub menus/options/set values/page in the start guide. D Back button The back button is used to: ■ go back to the previous menu. ■ change a setting that has not been confirmed. E Control knob The control knob can be turned to the right or…
-
Menu system
When the door to the heat pump is opened, the menu system’s four main menus are shown in the display as well as certain basic information. Outdoor temperature Indoor temperature - (if room sensors are installed) INDOOR CLIMATE HOT WATER Hot water temp. Information about operation SERVICE HEAT PUMP…
-
Symbols in the display
The following symbols can appear in the display during operation. Symbol Description This symbol appears by the information sign if there is information in menu 3.1 that you should note. These two symbols indicate whether the compressor or addition is blocked in F750. These can, for example, be…
-
Menu number – marked sub menu
Name and menu number – main menu Symbol – main menu INDOOR CLIMATE HOT WATER INDOOR CLIMATE 1 temperature ventilation normal scheduling off advanced HEAT PUMP INFO Marked main menu Symbols – sub menus Name – sub menus Status information – sub menus Operation To move the cursor, turn the control knob…
-
Selecting options
comfort mode2.2 economy normal luxury Alternative In an options menu the current selected option is indicated by a green tick. To select another option: 1. Mark the applicable option. One of the options is pre-selected (white). 2. Press the OK button to confirm the selected option. The selected…
-
Setting a value
time & date4.4 time 24 h 12 h date day month year Values to be changed To set a value: 1. Mark the value you want to set using the control knob. 2. Press the OK button. The background of the value becomes green, which means that you have accessed the setting mode. 3. Turn the control knob to the…
-
Use the virtual keyboard
Different keyboards In some menus where text may require entering, a virtual keyboard is available. Depending on the menu, you can gain access to different character sets which you can select using the control knob. To change character table, press the Back button. If a menu only has one character…
-
Scroll through the windows
A menu can consist of several windows. Turn the control knob to scroll between the windows. Current menu window Number of windows in the menu Scroll through the windows in the start guide language 4.6 Arrows to scroll through window in start guide 1. Turn the control knob until one of the arrows in…
-
Maintenance of F750
Regular checks Your heat pump requires minimal maintenance after commissioning. On the other hand, it is recommended that you check your installation regularly. If something unusual occurs, messages about the malfunction appear in the display in the form of different alarm texts. See alarm…
-
Cleaning the air filter
Clean the F750's air filter regularly, how often depends on the amount of dust in the ventilation air. Select what is most suitable for your heat pump. You will receive a reminder about filter cleaning in the display. The default setting for the reminder is every three months, however, if the power…
-
Safety valves
F750 has two safety valves, one for the hot water heater and one for the climate system. The water heater's safety valve sometimes releases a little water after hot water usage. This is because the cold water, which enters the water heater, expands when heated causing the pressure to rise and the…
-
F750, copper
LEK / APH Safety valve for climate system LE K LEK Safety valve for water heater F750, stainless steel LEK / APH Safety valve for climate system LE K LEK Safety valve for water heater 26 Chapter 2 | The heat pump – the heart of the house NIBE F750
-
Cleaning the overflow cup
Condensation forms when the heat pump is working. This condensation is led off and collected in an overflow cup. In addition to water, a certain amount of dust and particles also collect in the overflow cup. LEK / APH F750, copper LE K LEK Overflow water container LEK / APH F750, stainless steel LE…
-
Filling the climate system
If the pressure is too low, increase as follows: 1. For F750, stainless steel: Check if the flexi hose supplied is connected between the two filler valves. Adjust the hose if this has not been done. 2. For F750, copper: Open the filling valve. The boiler section and the rest of the climate system…
-
F750, stainless steel
Venting valve Filler valve 2 LEK / APH Pressure meter LE K LEK Filler valve 1 Bleed valves Venting the climate system In event of repeated filling of the climate system or if bubbling sounds are heard from the heat pump the system may need venting. This is carried out as follows: 1. Set the switch…
-
Saving tips
Your heat pump installation produces heat and hot water. This occurs via the control settings you made. Factors that affect the energy consumption are, for example, indoor temperature, hot water consumption, the insulation level of the house and whether the house has many large window surfaces. The…
-
Domestic electricity
In the past it has been calculated that an average Swedish household has an approximate annual consumption of 5000 kWh domestic electricity/year. In today's society it is usually between 6000-12000 kWh/year. Equipment TV (Operation: 5 h/day, Standby: 19 h/day) Digital box (Operation: 5 h/day…
-
Example: A family with 2 children live in a house with 1 flat-screen TV, 1
digital box, 1 DVD player, 1 TV games console, 2 computers, 3 stereos, 2 bulbs in the WC, 2 bulbs in the bathroom, 4 bulbs in the kitchen, 3 bulbs outside, a washing machine, tumble drier, fridge, freezer, oven, vacuum cleaner, engine block heater = 6240 kWh domestic electricity/year Energy meter…
-
Set the indoor climate Overview Sub-menus For the menu INDOOR CLIMATE there are several sub-menus. Status information for the relevant menu can be found on the display to the right of the menus. temperature Setting the temperature for the climate system. The status information shows the set values…
-
A slow heat-releasing heating system, such as for example, underfloor
heating, may not be suitable for control using the heat pump's room sensor. To change the room temperature, use the control knob to set the desired temperature in the display. Confirm the new setting by pressing the OK button. The new temperature is shown on the right-hand side of the symbol in the…
-
Wait 24 hours before making a new setting, so that the room temperature has time to stabilise
If it is cold outdoors and the room temperature is too low, increase the curve slope in menu 1.9.1.1 by one increment. If it is cold outdoors and the room temperature is too high, reduce the curve slope in menu 1.9.1.1 by one increment. If it is warm outdoors and the room temperature is too low…
-
scheduling scheduling 1.3 In the menu scheduling indoor climate (heating/ventilation) is scheduled for each weekday. You can also schedule a longer period during a selected period (vacation) in menu 4.7. Menu 1.3.1 heating off ventilation off heating Increases or decreases in the accommodation…
-
System: Which climate system the schedule is for is selected here. This
alternative is only displayed if more than one climate system is present. Chapter 3 | F750 – at your service NIBE F750 37
-
Day: Select which day or days of the week the schedule is to apply to here
To remove the scheduling for a particular day, the time for that day must be reset by setting the start time to the same as the stop time. If the line "all" is used, all days in the period are set for these times. Time period: The start and stop time for the selected day for scheduling are selected…
-
Schedule
Activated SCHEDULING VENTILATION schedule 1 1.3.3 schedule 2 activated all mon tues wed thur fri 21:30 - 06:00 speed 3 sat sun Day Time period Adjusting Conflict Schedule: The schedule to be changed is selected here. Activated: Scheduling for the selected period is activated here. Set times are not…
-
Set the stop time earlier than the start time so that the period extends
beyond midnight. Scheduling then stops at the set stop time the day after. Scheduling always starts on the date that the start time is set for. Caution A significant change over a longer period of time may cause poor indoor environment and worse operating economy. Menu 1.9 advanced Menu advanced has…
-
heating curve
heating curve heating curve 1.9.1.1 Setting range: 0 - 15 system Default value: 5 flow temperature °C outdoor temp. °C The prescribed heating curve for your house can be viewed in the menu heating curve . The task of the heating curve is to give an even indoor temperature, regardless of the outdoor…
-
In the event of making fine adjustments for the indoor temperature,
the heat curve must be offset up or down instead, this is done in menu 1.1 temperature . Curve offset FRAMLEDNINGSTEMPERATUR Supply temperature °C 70 Offset heating curve Förskjuten värmekurva - 10 - 20 - 30 - 40°C An offset of the heating curve means that the supply temperature changes by the same…
-
To select another heat curve (slope)
NOTE If you only have one heating system, the number of the curve is already marked when the menu window opens. 1. Select the system (if more than one) for which the heat curve is to be changed. 2. When the system selection has been confirmed the heat curve number is marked. 3. Press the OK button…
-
Wait 24 hours before making a new setting, so that the room temperature has time to stabilise
If it is cold outdoors and the room temperature is too low, increase the curve slope by one increment. If it is cold outdoors and the room temperature is too high, lower the curve slope by one increment. If it is warm outdoors and the room temperature is too low, increase the curve offset by one…
-
min. flow line temp. heating min. flow line temp.1.9.3 Setting range: 20-70 °C Default value: 20 °C climate system 1 20 °C climate system 2 20 °C climate system 3 20 °C climate system 4 20 °C Set the minimum temperature on the supply temperature to the climate system. This means that F750 never…
-
room sensor settings factor system room sensor settings 1.9.4 heating control room sensor syst 1 Setting range: 0.0 - 6.0 factor system 1 Default value: 2.0 control room sensor syst 2 control room sensor syst 3 factor system 3 control room sensor syst 4 Room sensors to control the room temperature…
-
fan return time speed 1-4 fan return time1.9.6 Setting range: 1 – 99 h Default value: 4 h speed 1 hrs speed 2 hrs speed 3 hrs speed 4 hrs Here you select the return time for temporary speed change (speed 1-4) on the ventilation in menu 1.2. Return time is the time it takes before ventilation speed…
-
point offset outdoor temp. point point offset1.9.8 Setting range: -40 – 30 °C Default value: 0 °C change in curve outdoor temp. point °C change in curve °C flow temperature °C Setting range: -10 – 10 °C Default value: 0 °C outdoor temp. °C Select a change in the heating curve at a certain outdoor…
-
night cooling start temp. exhaust air night cooling1.9.9 Setting range: 20 – 30 °C Default value: 25 °C night cooling min diff. outdoor-exhaust Setting range: 3 – 10 °C start temp. exhaust air °C min diff. outdoor-exhaust °C Default value: 6 °C Activate night cooling here. When the temperature in…
-
Set the hot water capacity
Overview Sub-menus HOT WATER 2 For the menu HOT WATER there are several sub-menus. Status information for the relevant menu can be found on the display to the right of the menus. temporary lux Activation of temporary increase in the hot water temperature. Status information displays “off" or what…
-
If comfort mode "luxury" is selected in menu 2.2 no further increase can
be carried out. The function is activated immediately when a time period is selected and confirmed using the OK button. The remaining time for the selected setting is shown to the right. When the time has run out F750 returns to the mode set in menu 2.2. Select “off" to switch off temporary lux .…
-
scheduling What hot water comfort the heat pump is to work with can be scheduled here for up to two different time periods per day. Scheduling is activated/deactivated by ticking/unticking"activated". Set times are not affected at deactivation. Schedule: The schedule to be changed is selected here.…
-
advanced advanced 2.9 Menu advanced has orange text and is intended for the advanced user. This menu has several sub-menus. periodic increase hot water recirc. Menu 2.9.1 periodic increase period periodic increase 2.9.1 Setting range: 1 - 90 days Default value: 14 days activated start time period…
-
hot water recirc. operating time hot water recirc. 2.9.2 Setting range: 1 - 60 min Default value: 60 min operating time min downtime downtime min Setting range: 0 - 60 min Default value: 0 min period1 period2 period3 Set the hot water circulation for up to three periods per day here. During the set…
-
Get information
Overview Sub-menus For the menu INFO there are several sub-menus. No settings can be made in these menus, they just display information. Status information for the relevant menu can be found on the display to the right of the menus. service info shows temperature levels and settings in the…
-
service info Information about the heat pump’s actual operating status (e.g. current temperatures etc.) can be obtained here. No changes can be made. service info 3.1 EB100 status internal add. set max electrical add. off 5 The information is on several pages. Turn the control knob to scroll between…
-
add. heat info The information is on several pages. Turn the control knob to scroll between the pages. Menu 3.4 add. heat info3.3 Information about the additional heat's settings, operating status and statistics can be obtained here. No changes can be made. off status: time factor: alarm log alarm…
-
indoor temp. log Here you can see the average temperature indoors week by week during the past year. The dotted line indicates the annual average temperature. The average outdoor temperature is only shown if a room temperature sensor/room unit is installed. Otherwise, the exhaust air temperature is…
-
Adjust the heat pump
Overview Sub-menus For the menu HEAT PUMP there are several sub-menus. Status information for the relevant menu can be found on the display to the right of the menus. plus functions Settings applying to any installed extra functions in the heating system. op. mode Activation of manual or automatic…
-
internet internet4.1.3 Here you make settings for connecting F750 to the internet. NOTE For these functions to work the network cable must be connected. Menu 4.1.3.1 nibe uplink tcp/ip settings proxy settings NIBE Uplink Here you can manage the installation's connection to NIBE Uplink…
-
tcp/ip settings tcp/ip settings4.1.3.8 You can set TCP/IP settings for your installation here. Automatic setting (DHCP) 1. Tick “automatic". The installation now receives the TCP/IP settings using DHCP. 2. Mark “confirm" and press the OK button. automatic ip-address net mask gateway dns confirm…
-
If unsure about applicable settings, contact your network administrator
(or similar) for further information. Setting 1. 2. 3. 4. 5. 6. Tick “use proxy" if you do not want to use a proxy. Mark “server" and press the OK button. Enter the correct details via the virtual keypad. Mark “OK" and press the OK button. Repeat 1 - 3 for "port", "user name" and "password". Mark…
-
SG Ready SG Ready 4.1.5 This function can only be used in mains networks that support the "SG Ready"-standard . Make settings for the function "SG Ready" here. affect room temperature affect room temperature affect hot water Here you set whether room temperature should be affected when activating…
-
Smart price adaption™ smart price adaption 4.1.6 area In this menu you state where the heat pump is located and how great a role the electricity price should play. The greater the value, the greater the effect the electricity price has and the possible savings are larger, but at the same time there…
-
op. mode op. mode op. mode 4.2 Setting range: auto, manual, add. heat only Default value: auto auto manual functions add. heat only Setting range: compressor, addition, heating The heat pump operating mode is usually set to "auto". It is also possible to set the heat pump to "add. heat only", but…
-
"addition" is what helps the compressor to heat the accommodation
and/or the hot water when it cannot manage the whole requirement alone. "heating" means that you get heat in the accommodation. You can deselect the function when you do not wish to have heating running. Caution If you deselect "addition" it may mean that insufficient hot water and/or heating in the…
-
language Menu 4.7 holiday setting language 4.6 Choose the language that you want the information to be displayed in here. To reduce energy consumption during a holiday you can schedule a reduction in heating, ventilation and hot water temperature. Solar panel cooling can also be scheduled if the…
-
If you choose to switch off hot water production during the vacation
“periodic increase" (preventing bacterial growth) are blocked during this time. "periodic increase" started in conjunction with the vacation setting being completed. Caution If the exhaust air temperature falls below 16 °C, the compressor is blocked and electric additional heat is permitted. Heat is…
-
op. prioritisation op. prioritisation op. prioritisation 4.9.1 Setting range: 0 to 180 min Default value: 30 min hot water min heating min Choose here how long the heat pump should work with each requirement if there are two requirements at the same time. If there is only one requirement the heat…
-
It cannot be set "stop additional heat" higher than "stop heating"
Menu 4.9.3 degree minute setting current value degree minute setting4.9.3 Setting range: -3000 – 3000 start compressor current value Setting range: -1000 – -30 start compressor DM Default value: -60 start diff additional heat DM diff. between additional steps DM DM start diff additional heat Setting…
-
schedule blocking The compressor can be scheduled to be blocked for up to two different time periods here. Schedule Activated schedule blocking 4.9.5 schedule 1 When scheduling is active the actual blocking symbol in the main menu on the heat pump symbol is displayed. schedule 2 activated all mon…
-
Long term blocking can cause reduced comfort and operating economy
-
4 Disturbances in comfort
In most cases, the heat pump notes operational interference (operational interference can lead to disturbance in comfort) and indicates this with alarms and shows action instructions in the display. Info menu All the heat pump measurement values are gathered under menu 3.1 in the heat pump menu…
-
Selecting "aid mode” is not the same as correcting the problem that
caused the alarm. The status lamp will therefore continue to be red. If the alarm does not reset, contact your installer for suitable remedial action. NOTE Always give the product's serial number (14 digits) when reporting a fault. Troubleshooting If the operational interference is not shown in the…
-
– Enter menu 4.9.1 and increase the time for when hot water is to be
prioritised. Note that if the time for hot water is increased, the time for heating production is reduced, which can give lower/uneven room temperatures. ■ Filter blocked. – Clean or replace filter (see page 24). Low room temperature ■ Closed thermostats in several rooms. – See section "Saving tips"…
-
High room temperature
■ Too high set value on the automatic heating control. – Enter menu 1.1 (temperature) and reduce the offset heating curve. If the room temperature is only high in cold weather the curve slope in menu 1.9.1 "heating curve" needs adjusting down. ■ External switch for changing the room heating…
-
The compressor does not start
■ There is no heating requirement. – The heat pump does not call on heating nor hot water. – The heat pump defrosts. ■ Temperature conditions tripped. – Wait until the temperature condition has been reset. ■ Minimum time between compressor starts has not been reached. – Wait 30 minutes and then…
-
5 Technical data
Detailed technical specifications for this product can be found in the installation manual (www.nibe.eu). 78 Chapter 5 | Technical data NIBE F750
-
6 Glossary
Additional heat The additional heat is the heat produced in addition to the heat supplied by the compressor in your heat pump. Additional heaters can be for example, immersion heater, electric heater, gas/oil/pellet/wood burner or district heating. Buffer vessel A buffer vessel increases the system…
-
Disturbances in comfort
Disturbances in comfort are undesirable changes to the hot water/indoor comfort, for example when the temperature of the hot water is too low or if the indoor temperature is not at the desired level. A malfunction in the heat pump can sometimes be noticed in the form of a disturbance in comfort. In…
-
Extract air
The air that the heat pump has retrieved heat from and which has therefore been cooled. This air is blown out of the building. Filtering time Indicates the time the average outdoor temperature is calculated on. Flow pipe The line in which the heated water is transported from the heat pump out to the…
-
Pressostat
Pressure switch that triggers an alarm and/or stops the compressor if nonpermitted pressures occur in the system. A high pressure pressostat trips if the condensing pressure is too great. A low pressure pressostat trips if the evaporation pressure is too low. Radiator Another word for heating…
-
Supply temperature
The temperature of the heated water that the heat pump sends out to the heating system. The colder the outdoor temperature, the higher the supply line temperature becomes. Water heater Container where domestic water is heated. Is located inside the heat pump, but an extra hot water heater can be…
-
7 Item register
A Adjust the heat pump, 59 Alarm, 73 B Back button, 15 C Contact with F750, 13 Display unit, 14 External information, 13 Menu system, 16 Control knob, 15 D Display, 14 Display unit, 14 Back button, 15 Control knob, 15 Display, 14 OK button, 15 Status lamp, 14 Switch, 15 Disturbances in comfort, 73…
-
T
Technical data, 78 The heat pump – the heart of the house, 10 Troubleshooting, 74 U Use the virtual keyboard, 21 Chapter 7 | Item register NIBE F750 85
-