Installer manual
NIBE F750 Exhaust air heat pump LE K IHB GB 1723-1 431408
-
Quick guide
Navigation Ok button (confirm/select) Back button (back/undo/exit) Control knob (move/increase/reduce) A detailed explanation of the button functions can be found on page 34. How to scroll through menus and make different settings is described on page 36. Set the indoor climate INDOOR CLIMATE HOT…
-
Table of Contents
1 Important information Safety information General 2 Delivery and handling Transport Assembly Supplied components Removing the covers Removing parts of the insulation 3 The heat pump design Component positions 4 Pipe and ventilation connections General pipe connections Dimensions and pipe…
-
1 Important information
Safety information General This manual describes installation and service procedures for implementation by specialists. Serial number The manual must be left with the customer. The serial number can be found at the bottom right of the front cover and in the info menu (menu 3.1). This appliance can…
-
Inspection of the installation
Current regulations require the heating installation to be inspected before it is commissioned. The inspection must be carried out by a suitably qualified person. In addition, fill in the page for the installation data in the User Manual. ✔ Description Notes Signature Date Ventilation (page 18)…
-
2 Delivery and handling
15 - 40 mm Transport Assembly F750 should be transported and stored vertically in a dry place. However. the F750 may be carefully laid on its back when being moved into a building. The centre of gravity is in the upper part. ■ Position F750 on a fixed foundation that can take the 0 Because water…
-
Installation area
Supplied components Leave a free space of 800 mm in front of the product. Leave free space between F750 and wall/other machinery/fittings/cables/pipes etc. It is recommended that a space of at least 10 mm is left to reduce the risk of noise and of any vibrations being propagated. Outside sensor Room…
-
Removing the covers
Removing parts of the insulation Front cover Parts of the insulation can be removed to facilitate the installation. 1 Insulation, top 1. Disconnect the cable from the motor and remove the motor from the shuttle valve as illustrated. 3 A 4 LEK 2 LE K LE K B LEK The side covers can be removed to…
-
LEK / APH
2. Grip the handle and pull the insulation carefully towards you as illustrated. TIP Remove the hatch for the immersion heater card so that it is easier to remove the insulation (see page 20). NIBE F750 Chapter 2 | Delivery and handling 9
-
Component positions
-
F750, stainless steel
-
Pipe connections
XL1 XL2 XL3 XL4 XL5 XL10 XL31 XL32 Connection, heating medium flow line Connection, heating medium return line Connection, cold water Connection, hot water Connection, hot water circulation Connection, draining heating medium Ventilation connection, exhaust air Ventilation connection, extract air…
-
4 Pipe and ventilation connections
General pipe connections System diagram Pipe installation must be carried out in accordance with current norms and directives. F750 consists of a heat pump, water heater, buffer vessel, immersion heater, fan, circulation pump and control system.F750 is connected to the ventilation system and heating…
-
F750
-
Symbol key
Heating medium side Symbol Meaning Connecting the climate system Mixing valve A climate system is a system that regulates indoor comfort with the help of the control system in F750 and for example radiators, under floor heating/cooling, fan coils etc. ■ Install the enclosed filterballs as…
-
Installation alternative
Extra hot water heaters F750 can be installed in several different ways, some of which are shown below. The heat pump should be supplemented with an extra water heater, if a large bath tub or other significant consumer of hot water is installed. Further option information is available at www.nibe.eu…
-
Hot water circulation (VVC)
To reduce the risk of bacterial growth in systems with hot water circulation, the temperature of the circulating water should not fall below 50°C. Nor should there be any hot water pipes containing stationary water. Adjust the hot water system so that the temperature does not fall below 50°C at the…
-
60Exhaust air
370 350 2075 Connect F750 so that all of the exhaust air, except kitchen duct air (kitchen fan), passes the evaporator (EP1) in the heat pump. The lowest ventilation flow must comply with the applicable national standards. For optimum heat pump performance, the ventilation flow should not be less…
-
5 Electrical connections
General NOTE All electrical equipment, except the outdoor sensors, room sensors and the current sensors are ready connected at the factory. ■ Disconnect the heat pump before insulation testing the house wiring. Electrical installation and service must be carried out under the supervision of a…
-
Removing the cover, base circuit board
Accessibility, electrical connection The plastic cap of the electrical boxes is opened using a screwdriver. Caution To remove the cover for the base board, the cover for the input circuit board must first be removed. NOTE The cover for the input card is opened without a tool. A Removing the cover…
-
Connection 3x230V
Connections NOTE AA1-X1 To prevent interference, unscreened communication and/or sensor cables to external connections must not be laid closer than 20 cm from high voltage cables. PE L1 1 L2 2 L3 Power connection F750 must be installed via an isolator switch with a minimum breaking gap of 3mm.…
-
Connecting external operating voltage for
the control system NOTE Only applies to power connection of 3x400V. NOTE Mark up any junction boxes with warnings for external voltage. Outside sensor Install the outdoor temperature sensor (BT1) in the shade on a wall facing north or north-west, so it is unaffected by the morning sun for example.…
-
Room sensor
F750 is supplied with a room sensor enclosed (BT50). The room sensor has up to three functions: 1. Show current room temperature in F750's display. 2. Option of changing the room temperature in °C. 3. Makes it possible to change/stabilise the room temperature. Install the sensor in a neutral…
-
3x230V
Settings BT30 AA1-X3 AA1-SF2 AA1-X7 Electrical addition (kW) Max (A) (L1) Max (A) L2 Max (A) L3 0.0 1.0 2.0 3.0 4.0 5.0* 1.0 1.0 9.2 9.2 9.2 9.2 1.0 4.9 1.0 4.9 9.2 13.5 4.3 8.7 11.5 15.1 18.9 6.0 7.0 17.9 17.9 9.2 13.5 23.0 26.4 Electrical addition - maximum output *Default value The immersion…
-
Emergency mode
3x400V Power in emergency mode The immersion heater's power in emergency mode is set with the dip switch (S2) on the immersion heater board (AA1) according to the table below. The factory setting is 4 kW (5 kW at 3x230V). 3x400 V kW 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 on off on off…
-
Optional connections
Load monitor Integrated load monitor Connect the cable to the input board (AA3) on terminal X4:1-4 block - where X4:1 is the common terminal block for the three current sensors. Incoming electricity PEN L1 L2 L3 F750 is equipped with a simple form of integrated load monitor, which limits the power…
-
Contact for external tariff blocking
soft in/outputs5.4 In those cases where external tariff blocking is used, it can be connected to terminal block X6 on the input board (AA3), which is positioned behind the front cover. block heating activate temp lux Tariff blocking means that the additional heat, the compressor, the heating and hot…
-
Switch for +Adjust
Contact for activation of “external adjustment" Using +Adjust, the installation communicates with the underfloor heating's control centre* and adjusts the heat curve and calculated supply temperature according to the underfloor heating system's reconnection. An external contact function can be…
-
An accessory board is required, if several functions are connected to terminal block X7 at the
same time the common alarm is activated (see page 52). C NO NC AA3-X7 AA3-X7 The picture shows the relay in the alarm position. When switch (SF1) is in the " " or " is in the alarm position. " position the relay External circulation pump or hot water circulation pump connected to the buzzer alarm…
-
6 Commissioning and adjusting
Preparations 1. Check that the switch (SF1) is in position " ". 2. Check that the filling valves (QM10) and (QM11) are fully closed. Caution Check the miniature circuit-breaker (FA1) in the heat pump. It may have tripped during transportation. Venting the climate system 1. Set the switch (SF1) in…
-
Start-up and inspection
NOTE Operation in the start guide A. Page B. Name and menu number Warning: Do not start the heat pump if there is a risk that the water in the system has frozen. language 4.6 Start guide NOTE There must be water in the climate system before the switch is set to " ". 1. Set switch (SF1) on F750 to…
-
Setting the ventilation
Commissioning without fan Ventilation must be set according to applicable standards. Set the fan speed in menu 5.1.5. The heat pump can be run without recovery, as only an electric boiler, to produce heat and hot water, for example before the ventilation installation is complete. Even if ventilation…
-
Capacity, heating medium pump 2 (GP6)
Speed I Output, heating medium pump 2 (GP6) Effekt Pressure (watt) 50 45 Tillgängligt tryck Pressure (kPa) 0,1 0,2 0,3 0,4 0,0 0,1 0,2 0,3 0,4 0,5 0,5 Flöde Flow Flöde Flow (l/s) (l/s) Post-adjustment, venting Capacity, heating medium pump 2 (GP6) Speed II Post-adjustment, venting Tillgängligt tryck…
-
7 Control - Introduction
Display unit F A Display INDOOR CLIMATE ■ Standby ( ) HOT WATER INFO ■ Emergency mode ( D Back button F750 A Display B Status lamp ) (see page 46) Emergency mode must only be used in the event of a fault on the heat pump. In this mode, the compressor switches off and the immersion heater engages.…
-
Symbols in the display
Menu system When the door to the heat pump is opened, the menu system’s four main menus are shown in the display as well as certain basic information. Outdoor temperature Indoor temperature - (if room sensors are installed) INDOOR CLIMATE HOT WATER The following symbols can appear in the display…
-
Menu number – marked sub menu
Name and menu number – main menu Symbol – main menu INDOOR CLIMATE HOT WATER INDOOR CLIMATE 1 temperature ventilation normal scheduling off advanced HEAT PUMP INFO Marked main menu Symbols – sub menus Operation To move the cursor, turn the control knob to the left or the right. The marked position…
-
Use the virtual keyboard
Help menu In many menus there is a symbol that indicates that extra help is available. To access the help text: 1. Use the control knob to select the help symbol. 2. Press the OK button. Different keyboards The help text often consists of several windows that you can scroll between using the control…
-
8 Control - Menus
Menu 1 - INDOOR CLIMATE Overview 1 - INDOOR CLIMATE 1.1 - temperature 1.2 - ventilation 1.3 - scheduling 1.3.1 - heating 1.3.3 - ventilation 1.9 - advanced 1.9.1.1 - heating curve 1.9.2 - external adjustment 1.9.3 - min. flow line temp. 1.9.4 - room sensor settings 1.9.6 - fan return time 1.9.7…
-
Menu 4 - HEAT PUMP
Overview 4 - HEAT PUMP 4.1 - plus functions * 4.1.3 - internet 4.1.3.1 - NIBE Uplink 4.1.3.8 - tcp/ip settings 4.1.3.9 - proxy settings 4.1.4 - sms * 4.1.5 - SG Ready 4.1.6 - smart price adaption™ 4.2 - op. mode 4.3 - my icons 4.4 - time & date 4.6 - language 4.7 - holiday setting 4.9 - advanced…
-
Menu 5 - SERVICE
Overview 5 - SERVICE 5.1 - operating settings 5.1.1 - hot water settings 5.1.2 - max flow line temperature 5.1.3 - max diff flow line temp. 5.1.4 - alarm actions 5.1.5 - fan sp. exhaust air 5.1.11 - charge pump speed 5.1.12 - internal electrical addition 5.1.14 - flow set. climate system 5.1.24…
-
Menu 5.1.1 - hot water settings
Menu 5.1.2 - max flow line temperature economy climate system Setting range start temp. economy: 15 - 52 °C Setting range: 20-70 °C Factory setting start temp. economy: 40 °C Default value: 60 °C F750 copper: 43 °C F750 stainless steel: 42 °C Setting range stop temp. economy: 15 - 55 °C Factory…
-
Menu 5.1.4 - alarm actions
Menu 5.1.11 - charge pump speed Select how you want the heat pump to alert you that there is an alarm in the display here. Operating status The different alternatives are that the heat pump stops producing hot water (default setting) and/or reduces the room temperature. Caution If no alarm action is…
-
Here you set the max. electrical output of the internal
electric additional heat in F750 during normal operation and overcapacity mode (SG Ready), as well as the fuse size and transformer ratio for the installation. The transformer ratio is the factor that is used to convert the metered voltage to current. Here you can also check which current sensor is…
-
Menu 5.1.99 - other settings
See the accessory installation instructions for function description. months btwn filter alarms Menu 5.4 - soft in/outputs Setting range: 1 – 12 Default value: 3 Here you can select the in/output on the input circuit board (AA3) the external contact function (page 26) is to be connected to. Set…
-
Menu 5.9 - floor drying function
length of period 1 – 7 Setting range: 0 – 30 days Factory setting, period 1 – 3, 5 – 7: 2 days Factory setting, period 4: 3 days temp. period 1 – 7 Setting range: 15 – 70 °C Default value: temp. period 1 temp. period 2 temp. period 3 temp. period 4 temp. period 5 temp. period 6 temp. period 7 20 °C…
-
9 Service
NOTE NOTE Servicing and maintenance should only be carried out by persons with the necessary expertise. There may be some hot water when draining the heating medium side/climate system. There is a risk of scalding. When replacing components on F750 only replacement parts from NIBE may be used.…
-
Temperature sensor data
Temperature (°C) Resistance (kOhm) Voltage (VDC) -40 -35 -30 -25 -20 -15 -10 -5 351.0 251.6 182.5 133.8 99.22 74.32 56.20 42.89 33.02 25.61 20.02 15.77 12.51 10.00 8.045 6.514 5.306 4.348 3.583 2.968 2.467 2.068 1.739 1.469 1.246 1.061 0.908 0.779 0.672 3.256 3.240 3.218 3.189 3.150 3.105 3.047…
-
Menu 7.1 - update firmware
USB service outlet update firmware7.1 start updating choose another file LEK This allows you to update the software in F750. NOTE The display unit is equipped with a USB socket that can be used to update the software, save logged information and manage the settings in F750. INDOOR CLIMATE HOT WATER…
-
choose another file
Menu 7.3 - manage settings update firmware7.1 manage settings 7.3 save settings recover settings Select “choose another file" if you do not want to use the suggested software. When you scroll through the files, information about the marked software is shown in a fact box just as before. When you…
-
10 Disturbances in comfort
In most cases, the heat pump notes operational interference (operational interference can lead to disturbance in comfort) and indicates this with alarms and shows action instructions in the display. Info-menu All the heat pump measurement values are gathered under menu 3.1 in the heat pump menu…
-
■ Too low set value on the automatic heating control
– Enter menu 1.1 "temperature" and adjust the offset heating curve up. If the room temperature is only low in cold weather the curve slope in menu 1.9.1 "heating curve" needs adjusting up. ■ Too low or no operating prioritisation of heat. – Enter menu 4.9.1 and increase the time for when heating is…
-
11 Accessories
Not all accessories are available on all markets. Splitter kit DKI 10 Communications module MODBUS 40 For split installation of F750. MODBUS 40 enables F750 to be controlled and monitored using a DUC (computer sub-centre) in the building. Communication is then performed using MODBUS-RTU. Part no.…
-
Eminent
Water heater with immersion heater. Eminent 35 Eminent 55 Copper Part no. 072 310 Copper Part no. 072 340 Enamel Part no. 072 300 Enamel Part no. 072 330 Stainless Part no. 072 320 Stainless Part no. 072 350 Eminent 100 Eminent 120 Copper Part no. 072 370 Stainless Part no. 072 384 Enamel Part no.…
-
12 Technical data
Dimensions and setting-out coordinates F750 installed as one unit. Ø 125 Extract air Ø 125 Avoid routing pipes through the marked area Exhaust air 25-50 2075 Chapter 12 | Technical data NIBE F750
-
F750 at separated installation. Ø 125 Ø125 Ø 125 Extract air Ø125 Exhaust air Avoid routing pipes through the marked area 505120 25-50 25-50 1575 1575 NIBE F750 Chapter 12 | Technical data 55
-
Technical specifications
IP 21 3x400 V Output data according to EN 14 511 Specified heating output (PH)1 Copper kW COP1 Specified heating output (PH)2 5.35 2.43 kW 6.5 (6.5) V A A W W 400 V 3N ~ 50 Hz 17.3 16 5-45 25-140 IP 21 kg ton R407C 1774 0.74 1,312 MPa/bar MPa/bar 2.9 / 29.0 0.05 / 0.5 MPa/bar °C 0.25 / 2.5 70 (60)…
-
Other 3x400 V
Water heater and heating section Volume heating section (of which buffer vessel) Volume, hot water heater Volume buffer vessel Max pressure in hot water heater Capacity, hot water Tap volume 40 °C according to EN 255-3(Vmax)6,7 Tap volume 40 °C according to EN 16 147(Vmax)6,7 Copper Stainless litre…
-
3x230 V
Stainless Output data according to EN 14 511 Specified heating output (PH)1 kW COP1 4.79 )2 kW Specified heating output (PH)3 kW Specified heating output (PH COP2 Additional power Max power, immersion heater (factory setting) Electrical data Rated voltage Max operating current Min. fuse rating Drive…
-
Other 3x230 V
Water heater and heating section Volume heating section (of which buffer vessel) Volume, hot water heater Volume buffer vessel Max pressure in hot water heater Capacity, hot water Tap volume 40 °C according to EN 255-3(Vmax)6,7 Tap volume 40 °C according to EN 16 147(Vmax)6,7 Stainless litre litre…
-
Energy labelling
Information sheet Supplier NIBE Model F750 Temperature application °C Declared load profile for water heating 35 / 55 L A++ / A++ Seasonal space heating energy efficiency class, average climate Water heating energy efficiency class, average climate A Rated heat output (Pdesignh), average climate…
-
Technical documentation
Model F750 Type of heat pump Air-water Exhaust-water Brine-water Water-water Low-temperature heat pump Yes No Integrated immersion heater for additional heat Yes No Heat pump combination heater Yes No Climate Average Temperature application Applied standards Rated heat output Prated Cold Warm…
-
Page 2/7 Created:2017-05-03 12:16
-
Page 3/7 Created:2017-05-03 12:16
-
Page 4/7 Created:2017-05-03 12:16
-
Page 5/7 Created:2017-05-03 12:16
-
Page 6/7 Created:2017-05-03 12:16
-
Page 7/7 Created:2017-05-03 12:16
-
230V 3 ~ 50Hz, 7kW
Chapter 12 | Technical data Page 2/7 Created:2017-05-09 08:24 051198-1 Part Specification Sheet 68 051198 2017-04-10 Production KRN WIRING DIAGRAM F750, 3X230V ELSCHEMA F750, 3X230V 1 0.001 2017-05-09 MJN 3x230V NIBE F750
-
Page 3/7 Created:2017-05-09 08:24
-
Page 4/7 Created:2017-05-09 08:24
-
Page 5/7 Created:2017-05-09 08:24
-
Page 6/7 Created:2017-05-09 08:24
-
Page 7/7 Created:2017-05-09 08:24
-
13 Item register
Item register A Accessibility, electrical connection, 20 Accessories, 52 Adjusting ventilation, 18 Alarm, 50 Assembly, 6 B Back button, 34 C Cable lock, 20 Cold and hot water, 15 Commissioning and adjusting, 30 Filling and venting, 30 Preparations, 30 Start guide, 31 Start-up and inspection, 31…
-
Scroll through the windows, 37
Selecting menu, 36 Selecting options, 36 Setting a value, 36 Use the virtual keyboard, 37 Miniature circuit-breaker, 19 N NIBE Uplink, 26 NV 10, pressure/level/flow monitor brine, 28 O OK button, 34 Operation, 36 Optional connections, 26 Outdoor sensor, 22 P Pipe and ventilation connections, 13…
-