Installer manual
NIBE™ F130 LEK Heat pump IHB GB 1540-4 231984
-
Quick guide
Navigation Ok button (confirm/select) Up/down buttons (move/increase/reduce) Back button (back/undo/exit) A detailed explanation of the button functions can be found on page 22. How to scroll through menus and make different settings is described on page 23. Increase hot water volume true off 1X 2X…
-
Table of Contents
1 Important information Safety information 2 Delivery and handling Transport Assembly Supplied components Removing the covers 2 Filling and venting Start-up and inspection Control - Introduction The Heat pump design 8 4 Pipe and air connections 10 General pipe connections Dimensions and pipe…
-
1 Important information
Safety information This manual describes installation and service procedures for implementation by specialists. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been…
-
Inspection of the installation
Current regulations require the heating installation to be inspected before it is commissioned. The inspection must be carried out by a suitably qualified person. ✔ Description Notes Signature Date Ventilation, exhaust air (page 13) Setting the ventilation flow Exhaust air filter Ventilation…
-
Contact information
AT KNV Energietechnik GmbH, Gahberggasse 11, 4861 Schörfling Tel: +43 (0)7662 8963-0 Fax: +43 (0)7662 8963-44 E-mail: mail@knv.at www.knv.at CH NIBE Wärmetechnik c/o ait Schweiz AG, Industriepark, CH-6246 Altishofen Tel: (52) Fax: (52) E-mail: info@nibe.ch www.nibe.ch CZ Druzstevni zavody Drazice…
-
2 Delivery and handling
Transport 40 mm Transport F130 should be transported and stored vertically in a dry place. Assembly Installation area Leave a free space of 800 mm in front of the heat pump. Approx. 50 mm free space is required on each side, to remove the side panels. The panels do not need to be removed during…
-
Supplied components
Location LEK The kit of supplied items is placed on top of the product. LEK Display Filter cartridge LEK Air connection Silencer vi nk ar oM K LE K LE 4-pin display connector 6-pin sensor connector 2 x sensors Choke washer Ø22 mm Drainage hose Ø 20 mm 2 x bracket L=2200 mm 6 x screws LEK LEK LE K x…
-
Side panels
Removing the covers 1. 2. 3. 4. Front hatch Undo the screws at the edge. Twist the cover slightly outward. Move the side cover outwards and backwards. Assembly takes place in the reverse order. LEK K LE 1. Slacken off the screws for the securing plate above F130. 2. Slide the hatch upwards and pull…
-
3 The Heat pump design
-
Pipe connections
Electrical components XL 41 XL 42 XL43 XL44 WM2 AA2 CA1 EB10 X 10 X 11 Connection, hot water outgoing Connection, hot water incoming Connecting incoming air Connecting outgoing air Overflow water discharge1 Base card Capacitor Compressor heater Sensor switch Display switch HVAC components Cooling…
-
4 Pipe and air connections
General pipe connections Pipe installation must be carried out in accordance with current norms and directives. F130 is only designed for upright installation. All connections are equipped with smooth pipe for compression ring couplings. Overflow water from the evaporator's collecting trough is…
-
Dimensions and pipe connections
Pipe dimensions Connection (mm) (mm) (mm) XL41 Outgoing hot water ext Ø XL42 Incoming hot water ext Ø WM2 Overflow water discharge int Ø XL42 NIBE™ F130 WM2 XL41 Chapter 4 | Pipe and air connections 11
-
Installing brackets
Mounting 1. Install the brackets together using the M6 screws and nuts supplied. 2. Drill holes in the wall as illustrated. 3. Fit the brackets on the wall. 4. Screw F130 into place in the brackets using the M5 screws and nuts supplied. The heat pump is wall-mounted using the brackets supplied. The…
-
Connecting cold and hot water
Installation alternative For optimal hot water operation, install the supplied choke washer. F130 must be connected according to the instructions in this manual. The washer is installed in the connection for outgoing hot water (XL41) or connection for incoming hot water (XL42) before the compression…
-
Surrounding air
Take incoming air from one room and release the outgoing air to the same room. Connecting surrounding air With surrounding air connection the heat in the room air is used to heat up the hot water. The outgoing air can be used to cool a room. ■ If the incoming air is taken from the same room where…
-
L EK
Install the filter cartridge General air connections Air installation must be carried out in accordance with applicable directives. To prevent fan noise being transferred to the ventilation devices, it may be a good idea to install a silencer in the duct, alternatively mount the enclosed silencer in…
-
Exhaust air duct /kitchen fan
Exhaust air duct (kitchen fan) must not be connected to F130. To prevent food vapour being transferred to F130 the distance between the kitchen fan and the exhaust air device must be considered. The distance should not be less than 1.5 m, but this can vary between different installations. Always use…
-
5 Electrical connections
General 1. Installation must be carried out in accordance with current standards and directives. LE K When working behind screwed covers, the circuit fuse must be removed or the connection plug pulled out. Work behind screwed covers may only be carried out under the supervision of a qualified…
-
Display
-
Optional connections
AUX inputs Switch for external blocking of compressor When external blocking of the compressor is desired, this can be connected to terminal block X13 on the base board (AA2). The compressor is disconnected by connecting a potential-free switch function to AUX2 (X13:3 och X13:4) (compressor). A…
-
6 Commissioning and adjusting
Preparations Start-up and inspection 1. Check that the display is off. 2. Check that the filling valves are fully closed. Starting NOTE Caution Check miniature circuit breaker (FA1) in the heat pump. It may have tripped during transportation. Filling and venting Filling There must be water in the…
-
Setting ventilation (exhaust air)
Ventilation must be set according to applicable standards. The setting is made in menu 5.1.5. Even if ventilation is roughly set at installation it is important that a ventilation adjustment is ordered and permitted. NOTE Order a ventilation adjustment to complete the setting. Fan capacity Available…
-
7 Control - Introduction
Display unit Menu system When F130 is started you come to the information menu. Basic information about the heat pump status is shown here. Date Clock A B C D E A Display B Stand-by button C Instructions, settings and operational information are shown on the display. F130 can be switched to stand-by…
-
Menu 5 - SERVICE
Setting a value Advanced settings. These settings are not available to the end user. Go to the main menu and hold the Back button in for 7 seconds to access the Service menu. See page 29. periodic increase 2.9.1 Symbols in the display activated The following symbols can appear in the display during…
-
8 Control - Menus
Menu 1 - ventilation Overview 1 - ventilation Menu 1 - ventilation Setting range: normal and speed 1-4 Default value: normal This menu is only shown with exhaust air installation. The ventilation in the accommodation can be temporarily increased or reduced here. When a new speed has been selected a…
-
Menu 2 - HOT WATER
Overview 2 - HOT WATER 2.1 - temporary lux 2.2 - comfort mode 2.3 - scheduling 2.9 - advanced * Accessory needed. 2.9.1 - periodic increase Sub-menus The difference between the selectable modes is the temperature of the hot tap water. Higher temperature means that the hot water lasts longer. This…
-
TIP
If you wish to set similar scheduling for every day of the week start by filling in “all” and then changing the desired days. Caution If the stop time is earlier in the day than the start time it means that the period extends past midnight. Scheduling always starts on the date that the start time is…
-
Menu 3 - INFO
Overview 3 - INFO 3.1 - service info 3.2 - compressor info 3.4 - alarm log Sub-menus For the menu INFO there are several sub-menus. No settings can be made in these menus, they just display information. service info shows temperature levels and software versions in the heat pump. compressor info…
-
Menu 4 - MY SYSTEM
Overview 4 - MY SYSTEM 4.4 - time & date 4.6 - language 4.7 - holiday setting 4.8 - alarm 4.9 - advanced 4.9.4 - factory setting Sub-menus Caution For the menu MY SYSTEM there are several submenus. Status information for the relevant menu can be found on the display to the right of the menus. If you…
-
Menu 5 - SERVICE
Overview 5 - SERVICE 5.1 - operating settings 5.1.1 - hot water settings 5.1.5 - fan speed 5.1.15 - air in-temperatures 5.1.16 - installation 5.5 - factory setting 5.6 - forced control 5.7 - start guide 5.8 - quick start Go to the main menu and hold the Back button in for 7 seconds to access the…
-
Menu 5.1.5 - fan speed
Menu 5.5 - factory setting Exhaust air installation All settings can be reset (including settings available to the user) to default values here. Setting range: 30 – 100 % Factory setting normal: 70 % Factory setting speed 1: 30 % Factory setting speed 2: 50 % NOTE When resetting, the start guide is…
-
9 Disturbances in comfort
If F130 is not installed together with the indoor module, go directly to section Troubleshooting. In most cases, the heat pump notes operational interference (operational interference can lead to disturbance in hot water comfort) and indicates this with an alarm in the display. Info menu All the…
-
Gurgling sound
■ Not enough water in the water seal. ■ Refill the water seal with water. ■ Choked water seal. ■ Check and adjust the condensation water hose. 32 Chapter 9 | Disturbances in comfort NIBE™ F130
-
10 Accessories
Top cabinet Top cabinet for concealing the ventilation ducts. 245 mm Part no. mm Part no. 089 757 395-645 mm Part no. 089 758 Water heater/Accumulator tank VPD10 150 Stainless steel water heater without immersion heater Part no. 086 017 VPD10 300 Stainless steel water heater without immersion heater…
-
11 Technical data
65-90 Dimensions and setting-out coordinates Ø125 220 Ø160 34 Chapter 11 | Technical data NIBE™ F130
-
Technical specifications
1x230 V Output data according to EN 14 511 Specified heating output (PH)1 kW COP1 3.87 Specified heating output (PH)2 kW COP2 Specified heating output (PH 1.42 1.34 3.13 )3 kW COP3 Electrical data Rated voltage Max operating current Driving power circulation pump Driving power fan Specified…
-
Miscellaneous
Dimensions and weight Width Depth Height (excluding connectors) Weight Part No. 36 Chapter 11 | Technical data mm mm mm kg - NIBE™ F130
-
Energy labelling
Supplier NIBE AB Model Model hot water heater Declared load profile Water heating energy efficiency class F130 Surrounding air F130 Surrounding air VPD10-150 VPD10-300 L A XL A Water heating energy efficiency, wh % 106 110 Annual energy consumption water heating, AEC Thermostat setting Sound power…
-
Electrical circuit diagram
38 Chapter 11 | Technical data NIBE™ F130
-
12 Item register
Item register A Accessories, 33 Adjusting ventilation, 16 Assembly, 5 C Commissioning and adjusting, 20 Filling and venting, 20 Preparations, 20 Start-up and inspection, 20 Connecting cold and hot water, 13 Contact information, 4 Control, 22, 24 Control - Introduction, 22 Control - Menus, 24 Control…
-
SE
Återvinning Lämna avfallshanteringen av emballaget till den installatör som installerade produkten eller till särskilda avfallsstationer. När produkten är uttjänt får den inte slängas bland vanligt hushållsavfall. Den ska lämnas in till särskilda avfallsstationer eller till återförsäljare som…
-
WS name: -Gemensamt
WS version: a83 (working edition) Publish date: 2015-09-18 08:35 NIBE AB Sweden Hannabadsvägen 5 Box 14 SE-285 21 Markaryd info@nibe.se www.nibe.eu 231984
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.