Alféa Excellia Duo A.I
Air/water heat pump split 2 services Outdoor unit WOYG112LHT U0611772_1879_EN_3 13/09/2017 FR NL DE EN IT ES PT PL PT PT Hydraulic unit 024116 WOYG140LCTA WOYK112LCTA 024117 WOYK140LCTA WOYK160LCTA Installation and commissioning instructions for professionals to be kept by the user for future…
-
""Installation
and maintenance regulations The appliance must be installed and maintained by an approved professional in accordance with current regulations and codes of practice. ""Handling The outdoor unit must not be placed in a horizontal position during transport. If not kept upright during transport, the…
-
""Electrical connections
• Before any maintenance operation, ensure that the general power supply is switched off. • Specifications of electricity supply The electrical installation must be carried out in accordance with current regulations. Electrical connections will only be made once all other installation operations…
-
This appliance must be installed by qualified personnel holding a certificate of competence in the handling of refrigerants. Contents Description of the equipment. . . . . . . . . . . . . . . . . . . . . . . . . . 6 Packing. . . . . . . . . . . . . . . . . . . . . . . . 6 Unpacking and supplies. . .…
-
Controller Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Menu Structure . . . . . . . . . . . . . . . . . . . . 52 Installed options. . . . . . . . . . . . . . . . . . . 53 Hydraulic configuration . . . . . . . . . . . . . . . . 53 Heat Pump Configuration . . . . . . . . . . . . . . 58 System status . . . . . . . . . . . . . . . . . . . . 60 Auxiliary…
-
1 Description of the equipment
1.1 Packing 1.3 • 1 package: Outdoor unit. • 1 package: Hydraulic unit and outside temperature sensor. 1.2 Unpacking and supplies While the courier is still present, carefully check the general appearance of the appliances and check that the outdoor unit has not been laid in a horizontal position.…
-
General characteristics Model name Alféa Excellia Duo A.I. 11 14 tri 11 tri 14 tri 16 Rated heating performances (outdoor temp. / flow temp.) Heat output +7°C/+35°C - Underfloor heating system kW 10.80 13.50 10.80 13.00 15.17 -7°C/+35°C - Underfloor heating system kW 10.38 11.54 10.38 12.20 12.98…
-
""Outdoor Unit, Alféa Excellia Duo A.I. 11 and 14 Air 370 hole (Ø 20) OrificeOverflow d’écoulement Bottom view Vue de dessous 4 4holes trous Ø Air 1290 Air 3/8” 5/8” Front view Vue de face Side view Vue de coté Top Vue de view dessus ""Outdoor Unit, Alféa Excellia Duo A.I. tri 11, 14 and Air…
-
""Hydraulic unit
Heating return. Heating flow. 47 1611 1679 1841 55 1190 1141 297 1296 DHW DCW 1851 Back view 115 Side view Front view Space requirements of the hydraulic unit, see figure 15, page 20. figure 2 - Dimensions in mm 1* 1 Elbow 2 Plugs (x2) (depending on model) 2* for condensate evacuation figure 3…
-
Variable pressure
Constant pressure mCE mCE 1 mbar = 10 mmCE = 100 Pa 0,5 0,5 mbar = 10 mmCE = 100 Pa 1 1 1,5 1,5 m m3/h /h 0 0,5 0,5 1 1 1,5 1,5 3 2 m m3/h /h 2 figure 5 - Available hydraulic pressures and flow rates Outside sensor QAC34 HP return sensor HP flow sensor 32500 30000 27500 25000 43907 22500 20000 10000…
-
Ohmic value (kΩ)
10000 - Compressor. - Discharge. - Condensation. - Expansion valve. 1000 - Outdoor 100 - Evaporator inlet. 10 1 -20 -10 Temperature °C figure 7 - Ohmic sensor values (Outdoor unit) Installation and Operating Manual "1879- EN" - 11 -
-
Description ""Alféa Excellia Duo A.I. 11 and 14 ""Alféa Excellia Duo A.I. tri 11 , 14 and Key: 1. High performance and low noise impeller. 2. Electrical motor with variable "inverter" operation. 3. "Inverter" control unit. 4. Check lights and buttons. 5. Connection terminal blocks (power supply and…
-
Key: 1 - Electric control box. 2 - Controller / User interface. 3 - Start/stop switch. 4 - Hydraulic unit circulation pump. 5 - Distribution valve. 6 - "Gas" refrigeration connection. 7 - "Liquid" refrigeration connection. 8 - Condensation sensor. 9 - Drain valve. 10 - Safety valve. 11 - Safety…
-
Operating principle The heat pump transmits the energy contained in the surrounding air into the dwelling to be heated and for production of domestic hot water. The heat pump consists of four main parts, in which a refrigerant (R410A) circulates. --In the evaporator (ref. 13, figure 8, page 12): The…
-
• Domestic hot water (DHW) operating principle
Two domestic hot water (DHW) temperatures can be set: comfort and reduced. The default DHW program is set to the comfort temperature between 00:00 and 05:00 and between 14:30 and 17:00 and to the reduced temperature for the rest of the day. This optimises electrical consumption while ensuring…
-
2 Installation
2.1 Installation of refrigeration connections "" Bend the pipes into position and make holes for them through the floor or walls either with their protective caps in place or after brazing. ""Keep the protective caps in place or ends brazed until the appliance is commissioned. The outdoor unit must…
-
Installation and Operating Manual "1879- EN" - 17 -
-
Installation of the outdoor unit 2.2.1 Installation precautions ""The outdoor unit must only be installed outside. If a shelter is required, it must have broad openings on all 4 sides and installation clearances must be observed (figure 13). • The outdoor unit is able to withstand bad weather but…
-
• Make sure that the unit does not disturb the
surrounding area or inhabitants (noise level, draught, low temperature of the ejected air freezing the plants in its path). • The surface on which the appliance is installed must: --Be permeable (soil, gravel, etc.), --Support its weight easily. --Allow a solid fastening base, --Not transmit any…
-
Installation of the hydraulic unit 2.3.1 Installation precautions 300 • Choose the location of the appliance after discussion with the client. • The installation space should comply with current regulations. • To facilitate maintenance and to allow access to the various components, we recommend that…
-
3 Refrigeration connections
and filling the installation with gas ""This appliance uses refrigerant R410A. Comply with the legislation on handling of refrigerants. 3.1 Rules and precautions ""Connections must be made on the same day the installation is filled with gas (3.4, page 24). • Minimum tools required --Set of pressure…
-
3.2.2 Creating the flarings
--Cut the pipe to an appropriate length with a pipe-cutter without damaging it. --Carefully deburr it, holding the pipe pointing downward to avoid introducing filings into the pipe. --Remove the flared connection nut situated on the valve to be connected and slide the pipe into the nut. --Proceed to…
-
Checks and connection ""The refrigeration circuit is very sensitive to dust and humidity: check that the area around the connection is clean and dry before removing the plugs protecting the refrigeration connectors. Nitrogen Gas connection ""Indicated blowing value: 6 bar for minimum 30 seconds for…
-
Filling the installation with gas ""This operation is reserved for installers familiar with the legislation for handling refrigerants. ""Creating a vacuum with a calibrated vacuum pump is essential (see APPENDIX 1). ""Never use equipment used previously with any refrigerant other than a HFC. ""Only…
-
3.4.1 Seal test
3.4.2 Creating a vacuum --Remove the protective plug (B) from the filling hole (Schrader) in the gas valve (large diameter). --Connect the high pressure hose from the Manifold to the filling hole (figure 22). --Connect the nitrogen bottle to the Manifold (only use dehydrated nitrogen type U). --Fill…
-
3.4.3 Filling with gas
If additional filling is required, do it before filling the hydraulic unit with gas. Refer to paragraph "Additional filling", page 26. 3.4.5 Additional filling 50 g of R410A for every additional 1 metre Length of the connections 15 m 20 m max. Additional load None 250 g --Remove the access plugs (A)…
-
3.4.6 Recovering the refrigerant in the outdoor
unit ""Before performing any maintenance, make sure that all power supplies have been cut off. "" Stored energy: after cutting off the power supplies, wait for 1 minute before accessing the internal parts of the equipment. Perform the following procedures to collect the refrigerant. --1- Switch the…
-
4 Hydraulic connections
4.1 Connecting the hydraulic unit to the heating circuit 4.1.1 Flushing the installation Before connecting the hydraulic unit to the installation, rinse out the heating system correctly to eliminate any particles that may affect the appliance's correct operation. Do not use solvents or aromatic…
-
4.1.3 Volume of the heating system
You must maintain the minimum installation water volume. Install a buffer tank on the return from the heating circuit in case the volume is lower than this value. Where the system is fitted with one or more thermostatic valves, you must ensure that this minimum water volume is able to circulate.…
-
Connecting to the DHW circuit Attach dielectric connections and DHW pipes to the tank (see figure 26). Insulate the pipes with the insulation provided. ""Be sure to place the DHW sensor back in the bottom of the tank thermowell. Mandatory: On the cold water inlet, place a safety valve calibrated to…
-
Filling and bleeding the installation Check the pipe fixings, tightness of the connectors and the stability of the hydraulic unit. Check the direction in which the water is circulating and that all the valves are open. Proceed to fill the installation. Do not operate the circulation pump during…
-
Heating circulation pump speed settings mCE 1 mbar = 10 mmCE = 100 Pa 8 Variable pressure The circulation pump varies the water pressure depending on the flow rate. Recommended for an installation fitted with radiators (particularly any system with thermostatic valves or zone solenoids). Do not use…
-
Pression
variable Variable pressure Dégazage Gas venting Circulation pump fouled or stuck: If the motor becomes stuck, a start-up cycle is launched. If the motor remains stuck, it will be permanently stopped. ""Cut off the power supply to the circulation pump for 30 secs in order to free it and allow a new…
-
5 Electrical connections
""Before any maintenance operation, ensure that the general power supply is switched off. ""Electrical installation must be performed in accordance with current regulations. The electrical diagram for the hydraulic unit is shown on figure 53, page 74. Room sensor A78 (battery/option) Outside sensor…
-
Cable dimensions and protection rating These cable dimensions are provided for information purposes only and do not exempt the installer from checking that these dimensions match requirements and comply with current standards. • Outdoor Unit Power Supply Single phase heat pump Electricity supply 230…
-
Electrical connections on the single phase outdoor unit side Access to connection terminals: --Remove the front plate. Remove the screws and front panel. --Make the connections according to the diagram(s) figure 35 and figure 41, page 39. Terminal Remove the screws and push downwards Terminal Remove…
-
Electrical connections on the 3 phase outdoor unit side Access to connection terminals: --Remove the front plate. Remove the screws and front panel. --Use cable clamps to prevent any power cables from being disconnected accidentally. --Fill in the space where the cables enter the outdoor unit with…
-
Electrical connections on the hydraulic unit side Access to connection terminals: --Remove the front plate. --Open the power control box. --Make the connections according to the diagram (figure 41). Do not place the sensor and power supply lines parallel to each other to avoid interference due to…
-
""Single phase model
Hydraulic unit Single phase outdoor unit L N L 2 N 4 towards external 230 V component contact* N L green/yellow brown blue red Interconnection between outdoor unit and hydraulic unit LN Power supply Electrical backup 230 V L N Power supply Domestic Hot Water 230 V Electricity supply single phase 230…
-
Safety thermostat
Power supply terminal block HP controller Power Relay for electric backup Terminal Cable grommets (power) DHW Relay + Terminal Cable grommets (sensors) Interface Board figure 42 - Description of the single phase hydraulic unit's electrical control box - 40 - Installation and Operating Manual "1879…
-
Safety thermostat
Power supply terminal block HP controller Static relay Terminal Cable grommets (power) DHW Relay + Terminal Cable grommets (sensors) Interface Board figure 43 - Description of the 3 phase hydraulic unit's electrical control box Installation and Operating Manual "1879- EN" - 41 -
-
Outside sensor The outside sensor is required for correct operation of the heat pump. Please see the fitting instructions on the sensor’s packaging. Place the sensor on the coldest side of the building, generally the northern or north-western side. It must not be exposed to morning sun. It must be…
-
Power limitation or
EDR (Energy Demand Reduction) Tariffs, peak times/offpeak times, day/night External fault X11 External component contact* (faults, power limiter, electricity meter) X86 X84 321 Outside sensor Typass ATL or Room sensor A59 (if cabled) Room sensor A75 If the control device does not provide a…
-
6 Commissioning
--Close the installation's main circuit breaker. Upon initial start-up (or in winter), to preheat the compressor, engage the installation's main circuit breaker (outdoor unit power supply) several hours before starting any tests. --Press the heat pump's Start/Stop button. To ensure that inputs EX1…
-
2nd circuit kit
--If the installation covers 2 zones, set "2nd circuit kit" to "Yes". No Easy Start Emitters type Area 1 (Direct circuit) --Choose the radiator type for each zone: Low temp. radiator / Heat. floor system / Dynamic Radiators / Radiators. Low temp. radiator Easy Start Cooling --If the installation is…
-
7 Controller Interface
7.1 User Interface 15:23 7 September 2017 15:23 OFF 12° OFF 7 September 2017 12° 21,5 21.5 19.5 19,0° 19,0° 19,0° ECO ECO ECO Zone 1 1 MENU Zone 2 MENU 2 3 ""1 heating Circuit version + domestic hot water (DHW) ""2 heating circuit version + domestic hot water (DHW) N° Description 1 Menu button 2…
-
Display Description 1 2 15:23 7 September 2017 21.5 19.5 19,0° 19,0° ECO 5 N° Symbols Definitions 1 Time 15:23 7 12° 9 ECO Zone 1 Zone 2 N° Symbols 9 Mode Definitions Comfort 2 7 September 2017 Date 21.5 Temperature measured by the room sensor* 19,0° Room temperature setpoint 3 4 Manual (exemption)…
-
Installer Menu To access the Installer Menu, press and hold the MENU button and turn the knob a quarter turn to the right. To return to the User Menu, repeat the same operation. MENU figure 46 - Installer Menu 7.4 Navigating the Menus For Action: Access the menu Press MENU . Choose a menu item Turn…
-
Modifying Settings • Turn the knob to highlight the setting you wish to change. MENU • Press the knob to accept the change. • Turn the knob to adjust the setting. • Press the knob to accept your choice. Installed options Hydraulic configuration HP configuration System status Auxiliary functions…
-
Temperature control The heat pump's operation is subject to the temperature control. The heating circuit water temperature setpoint is adjusted according to the outdoor temperature. If there are thermostatic valves on the installation, these must be fully open or set higher than the normal…
-
Heating flowchauffage temperature °C Température départ °C 2.5 100 2.25 1.75 Pente de la Heating gradient courbecurve de chauffe 2.75 Standard radiator Radiateur classique 1.5 With boiler connection Application relève de chaudière Radiateur BT radiator Low temperature 1.25 Heat pump application only…
-
8 Controller Menu
8.1 Menu Structure Installed options page 53 Hydraulic configuration Heating Control / Temperature control page 53 Temperature control Comfort optimisation ECO mode limitation Setting setpoint T° Time programming DHW General Configuration Time programming Setting setpoint T° Anti-legionella…
-
Installed options
8.2 Installed options Installed options are configured during commissioning (see page 44). However, you can modify them by accessing the "Installed Options" menu. Name of Appliance - Choose the appliance's power. Installed options Electrical backup - Choose the electrical backup power. Boiler…
-
Area 1
Control / Temperature control Temperature control ""Choose the temperature control to adjust: "Heating". ""Two methods for adjusting the temperature control are available: flow temperature or gradient control. ● Control using flow temperature 1 - Set "Room T° influence" then select "Advanced…
-
Area 1
Control / Temperature control Comfort optimisation Area 1 Comfort optimisation "Accelerated decrease": ON / Stop. "ECO / Comfort switchover" Anticipates time needed to reach the comfort setpoint. "Comfort / ECO switchover" Anticipates time needed to switch from comfort setpoint to ECO setpoint.…
-
Area 1
Time programming - Choose "Heating" or "Cooling" as well as the appropriate zone by accessing the menu: "Programming" > "Heating" / "Cooling" > "Area 1" / "Area 2". - Select the day. - Adjust the Comfort period start and end times. ""If 2 or 3 Comfort periods are not required, click on "--:--". --To…
-
Hot water
8.3.2 Hot Water (HW) General Configuration DHW Circuit Configuration Comfort T° charge "Comfort T° charge": DHW program + off-peak hours / Off-peak hours / Permanent. Electrical back-up power: 0 to 20 KW. DHW program + off-peak hours Electrical back-up power 1KW Time programming See "Time…
-
HP configuration
8.4 HP Heat Pump Configuration 8.4.1 Heat Pump Compressor configuration "Minimum shutdown time": 0 mins... 120 mins. "Max HP T°": 8°C... 100°C. "Post-circulation": 10 secs... 600 secs... "Power shedding operating": Automatic, When needed. HP Compressor configuration Minimum shutdown time 8 mins…
-
HP configuration
HP Tariff input configuration Heat Pump Tariff input configuration Power shedding + Off-peak hours Type of use "Type of use": Power shedding + Off-peak hours / Smartgrid. "EX1: function activation": 230V / 0V. "EX2: function activation": 230V / 0V. EX1: function activation 230V EX2: function…
-
System status
8.5 System status Active functions Active functions Indoor comfort The "Active Functions" page tells you which services are operating and allows you to change their status. --"Indoor comfort": Heating / Cooling / Stop. --"Area 1" / "Area 2" / "Hot water": ON / Stop. Heating Area 1 Start Area 2 Start…
-
System status
Temperature control See "7.6 Temperature control", page 50. Energy consumption Consumption can be displayed per usage: - Heating (Zones 1 and 2). - Cooling. - Domestic Hot Water (DHW). - Total (Heating + Cooling + Hot Water). Daily cons. 20kW.h This information is available for: - the last 8 days…
-
Auxiliary functions
8.6 Auxiliary functions Floor drying Area 1 floor drying --Choose the zone. --Choose the "Drying type": Stop / Automatic / Manual. --Set the "Flow T° setpoint": 0°C... 95°C. Drying type Stop Flow T° setpoint 25°C Emergency mode Emergency mode --Stop: The HP is operating normally (with backup if…
-
Auxiliary functions
Relay test --"HP circulation pump": ON / -----"Elec. backup 1": ON / -----"Area 2 circulation pump": ON / -----"Mixing valve": Open / Close / -----"DHW valve": DHW / -----"DHW backup": ON / -----"Boiler connection": ON / -----"Boiler connection ON / Stop": ON / Relay test HP circulation pump Elec.…
-
Settings Date and time Settings Date and time To set the appliance's date and time, access the menu: "Settings" > "Date and Time". Monday 12 September 2016 09: 45 Modify Validate Language Settings Language To set the appliance's language, access the menu: "Settings" > "Language". English Some…
-
Advanced/simplified menu
Two display modes for menus and appliance functions are available: - Advanced menu: - The appliance follows the time programming defined in paragraph "Time programming", page 56. - Simplified menu*: - The appliance operates at a constant temperature set directly by the user. - Some functions are no…
-
Areas name
Settings Circuits name You can customise the zone names from the menu: "Settings" > "Areas name". Rename Zone 1 in Available names: "Area 1" / "Area 2" / "Day area" / "Night area" / "1st floor" / "Lounge" / "G. floor" / "Bedroom" / "Floor" / "Radiator". Rename Zone 2 in Settings Day Night…
-
Software versions
Software version HMI: xxxx xxxx xxxx xxxx Show the display and controller software versions. Controller: RVS21 - 85.002.030 Some settings (or menus) might not be displayed. They are dependent on the installation's configuration (and installed options). Installation and Operating Manual "1879- EN"…
-
Easy Start Easy Start --Turn the knob to choose the language. --Press the knob to accept. English Easy Start --Turn the knob to adjust the date. Press the knob to accept. --Repeat this operation for the month, year, hours and minutes. Monday 12 September 2016 09: 45 Easy Start Alféa --Set the…
-
Emitters type
Area 1 (Direct circuit) --Choose the radiator type for each zone: Low temp. radiator / Heat. floor system / Dynamic Radiators / Radiators. Low temp. radiator Easy Start Cooling --If the installation is fitted with cooling function, choose the zone(s): None / Area 1 / Area 2 / Area 1 and 2. No Easy…
-
AE - DHW electrical backup CAR - Non-return valve C - HP circulation pump CCM - Mixed circuit circulation pump D - Shut-off Key: SE SSe Pg VE C VD Ssa SDp GS - Safety valve (mandatory) MT - Thermostatic mixing valve PC - Underfloor heating system Pg - Bleeder valve R - Radiators SR SaeC Sae AE MT…
-
Installation and Operating Manual "1879- EN"
AE - DHW electrical backup AVS - Extension board, 2 circuits CAR - Non-return valve C - HP circulation pump CCM - Mixed circuit circulation pump D - Shut-off Key: SE SSe Pg AVS VE C VD CCM Ssa SDpM SDp Sae AE GS - Safety valve (mandatory) K2c - 2 circuit kit MT - Thermostatic mixing valve PC…
-
10 Electrical Cabling Plans
Control board (Inverter) Pressure sensor Temperature sensor Compressor Option (connector) See the technical manual Temperature sensor Outdoor Temperature sensor Evaporator Temperature sensor Discharge Expansion valve coil Fuse Temperature sensor Radiator F4 T 5A - 250 V Temperature sensor Evaporator…
-
BU
-
0/I
-
таблицы и схемы — в просмотре
-
11 Fault Diagnosis
15:23 7 September 2017 OFF 12° --,- If a fault occurs, the error number appears on the welcome screen. To obtain the error's designation, select it using the knob. 24,0° Error XXX Error ""In the event of an error originating in the outdoor unit, the user interface displays error code "370…
-
11.2 Faults in the outdoor unit
Interface Board Error Outdoor Unit Board Error designation LED Green LED Red - UART communications error Hydraulic unit heat-exchange thermistor error Inverter error Active filter error, PFC error Discharge thermistor error Compressor thermistor error 5 Heat-exchange thermistor error (centre) 4…
-
12 Maintenance of the installation
""Before any maintenance operation, make sure that the general power supply is switched off. 6 12.1 Checking the hydraulic circuit ""If frequent refills are required it is absolutely essential that you check for any leaks. If refilling and a pressure reset are necessary, check what type of fluid was…
-
13 Other maintenance
13.1 Emptying the hydraulic unit Valve Flow towards exchanger A Ensure the distribution valve is fitted in the correct direction: Channel AB: Outlet to the hydraulic unit. Channel A open: Return from DHW tank. Channel B open: Return from the heating circuit. Valve motor Return from DHW tank 13.3 ACI…
-
14 Start-up procedure
Before switching on the hydraulic unit: • Check the electric wiring. • Check the refrigeration circuit and make sure that it has been gassed. • Check the hydraulic circuit's pressure (1 to 2 bar), check that the heat pump has been bled, along with the rest of the installation. • Make sure that ALL…
-
14.1.2 Starting-up
• Powering up (see chapter "Commissioning", page 44 and section "Controller Menu", page 52) OK Not compliant OK Not compliant Value OK Not compliant Value OK Not compliant Close the installation's main circuit breaker (outdoor unit power supply) 2 hours before testing => Preheating of the…
-
14.2 Commissioning technical datasheet
Site Outdoor unit Installer Serial No. Serial No. Hydraulic unit Model Model Refrigerant type Refrigerant load Checks Operating voltage & current on outdoor unit Compliance with positioning distances L/N or L1/N V Condensate evacuation correct L2/N V Electric connections / connections tightness L3/N…
-
Installation and Operating Manual "1879- EN" - 83 -
-
15 ErP performance figures
15.1 Definition of ErP The term "ErP" includes two directives that are part of the European program for reducing greenhouse gases: --The Ecodesign Directive establishes efficiency thresholds and prohibits the marketing of products whose efficiency is below these thresholds. --The Energy Labelling…
-
Trademark / Product name
Atlantic / Alféa Excellia Duo A.I. Export Code Heating applications 11 14 tri 11 tri 14 tri 16 526355 526356 526357 526358 526359 35°C 55°C 35°C 55°C 35°C 55°C 35°C 55°C 35°C 55°C Acoustic data Sound power level of hydraulic unit LWA dB (A) Sound power level of outdoor unit LWA dB (A) Declared heat…
-
15.3 Package datasheet
Outside sensor included in the combined package 074208 074213 074214 (Navilink A59) (Navilink A75) (Navilink A78) Controller class II Modulating room thermostat references (outdoor sensor included in the package) Seasonal efficiency contribution 2% Controller class VI Seasonal efficiency…
-
16 Instructions for the end user
Explain to the user the operation of the installation (heating and hot water temperature settings), especially the ambient sensor functions and the programs that are accessible via the user interface. Emphasise that a heated floor has significant inertia and that therefore any adjustments must be…
-
This equipment complies with
--Low Voltage Directive 2006/95/EC in accordance with EN 60335-1 and EN 60335-2-40 standards, --Electromechanical Compatibility Directive 2004/108/EC, --Machines Directive 2006/42/EC, --Pressure Equipment Directive 97/23/EC. --Ecodesign Directive 2009/125/EC, --Energy Labelling Directive 2010/30/EC.…