Portable air conditioner MPN1-09ERN1 MPN1-12ERN1 www.mdv-russia.ru
-
Safety Precaution
1 Safety precaution 1.1 Installation For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized service center. Do not disassemble or repair the product by yourself. Sharp edges could cause injury, be especially careful of the case edges and the fins on the condenser…
-
Safety Precaution
Do not insert hands or other object through air inlet or outlet while the product is operated. Do not drink the water drained from the product. Use a firm stool or ladder when cleaning or maintaining the product. Replace the all batteries in the remote control with new ones of the same type. Do not…
-
Outer dimension
2 Out dimension Model: MPN1-09ERN1 814 3
-
Outer dimension
MPN1-12ERN1 Model:
-
External view, part, display
-
Refrigerant cycle diagram
4 Refrigerant cycle diagram The figure below is a brief description of the important components and their function in what is called the refrigeration system 6
-
PCB drawing & Wiring diagram
-
Installation detail 6.1 Position requirement for installation Installation must be in a flat and spacious location where the air outlets will not be covered up. A minimum clearance of 30cm from a wall or other obstacles should be kept. The appliance shall not be used in the washroom. The plug shall…
-
Installation in a double-hung sash windows 6.3.1 Cut the foam seal (adhesive type) to the proper length and attach it to the window stool. 6.3.2 Attach the window panel to the window stool. Adjust the length of the window panel according to the width of window, short the adjustable panel if the…
-
Installation in a sliding sash windows 6.4.1 Cut the foam seal to a proper length and adhesive to the window frame. 6.4.2 Attach the window panel to the window stool. Adjust the length of the sliding window panel according to the width of window, short the adjustable panel if the width of window is…
-
6.4.5 11 Close the sliding sash securely against the window. Cut the foam seal to an appropriate length and sealing the open gap between the top window sash and outer window sash. Show as below picture.
-
Features Double louver flat appearance,Simple and generous Straight condenser ,low cost High-efficiency Turbo cooling function Flexible air exhaust Advanced shower system Follow me function 24 hour on/off Cooling Dry 12
-
Basic test procedure 8.1 Defective compressor Compressors are single phase, 115 or 230/208 volt, depending on the model unit. All compressor motors are permanent split capacitor type using only a running capacitor across the start and run terminal. All compressors are internally spring mounted and…
-
3. Start the system and run a “cooling or heating performance test.”
If test shows: A. Below normal high side pressure. B. Above normal low side pressure. C. Low temperature difference across coil. The compressor valves are faulty - replace the compressor. 8.1.4 Terminal overload (external) Some compressors are equipped with an external overload which is located in…
-
5. Vacuum Pump (capable of 200 microns or less vacuum.) 6. Acetylene Welder 7. Electronic Halogen Leak Detector (G.E. Type H-6 or equivalent.) 8. Accurate refrigerant charge measuring device such as: a. Balance Scales - 1/2 oz. accuracy b. Charging Board - 1/2 oz. accuracy 9. High Pressure Gauge…
-
refrigerant specified. This will prevent boiling the oil out of the crankcase
NOTE: If the entire charge will not enter the high side, allow the remainder to enter the low side in small increments while operating the unit. 12. Restart unit several times after allowing pressures to stabilize. Pinch off process tubes, cut and solder the ends. Remove pinch off tool, and leak…
-
3. Apply "live" test cord probes on black wire and common terminal of capacitor. Motor
should run at high speed. 4. Apply "live" test cord probes on red wire and common terminal of capacitor. Motor should run at low speed. 5. Apply "live" test cord probes on each of the remaining wires from the speed switch or system switch to test intermediate speeds. 8.4 Capacitor A run capacitor is…
-
Characteristic of temperature sensor
9 Characteristic of temperature sensor Temp.℃ -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 Resistance KΩ 62.2756 58.7079 56.3694 52.2438 49.3161 46.5725 44 41.5878 39.8239 37.1988 35.2024 33.3269 31.5635 29.9058 28.3459 26.8778 25.4954 24.1932 22.5662 21.8094 20.7184 19.6891 18.7177 17.8005 16.9341 16.1156…
-
Trouble shooting PROBLEM No power display POSSIBLE CAUSE Power failure REMEDY Check the power supplier if the power supplier is supplied to the unit. Check the power cord and correct if damaged. on panel or any Transformer (Discharge Check resistance between the two input/output lines on one of the…
-
Loose screws
Tighten them. Replace the motor if knocking sounds continue when Worn bearings running or loose, or the motor hums or noise appears to be internal while running. Voltage Check voltage. Call Supply Authority if not within limits. Check the wire connections, if loose, repair or replace the Wiring…
-
The inlet and outlet valve of the compressor is damaged,
making the low pressure connected with the high pressure. Compressor The refrigerating system can not produce high pressure and low pressure. Replace the compressor after checking for the reason. No cooling or heating. Heat sources Reduce if too many. No power Check the voltage. Call an electrician…