Мобильные кондиционеры MDV (сервис мануалы)
Мобильные кондиционеры MDV серии MPG-09ERN1. Сервис мануал.
Загружаем документ…
Текст каталога
-
СДЕЛАНО ДЛЯ РОССИИ
Portable air conditioner MPG-09ERN1 www.mdv-russia.ru
-
Outer dimension
1 Safety precaution 1.1 Installation For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized service center. Do not disassemble or repair the product by yourself. Sharp edges could cause injury, be especially careful of the case edges and the fins on the condenser…
-
Outer dimension
Use a firm stool or ladder when cleaning or maintaining the product. Replace the all batteries in the remote control with new ones of the same type. Do not mix old and mew batteries or different types of batteries. Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire.…
-
External view, part, display
2 Display
-
Refrigerant cycle diagram
3 Refrigerant cycle diagram The figure below is a brief description of the important components and their function in what is called the refrigeration system
-
PCB drawing & Wiring diagram
4 PCB drawing & wiring diagram
-
Feature
5 Installation detail
-
Basic test procedure 6.1 Defective compressor Compressors are single phase, 220~240 volt. All compressor motors are permanent split capacitor type using only a running capacitor across the start and run terminal. All compressors are internally spring mounted and externally mounted on rubber…
-
If test shows
A. Below normal high side pressure. B. Above normal low side pressure. C. Low temperature difference across coil. The compressor valves are faulty - replace the compressor. 6.1.4 Terminal overload (external) Some compressors are equipped with an external overload which is located in the compressor…
-
5. Vacuum Pump (capable of 200 microns or less vacuum.)
6. Acetylene Welder 7. Electronic Halogen Leak Detector (G.E. Type H-6 or equivalent.) 8. Accurate refrigerant charge measuring device such as: a. Balance Scales - 1/2 oz. accuracy b. Charging Board - 1/2 oz. accuracy 9. High Pressure Gauge - (0 - 400 lbs.) 10. Low Pressure Gauge - (30 - 150 lbs.)…
-
in small increments while operating the unit
12. Restart unit several times after allowing pressures to stabilize. Pinch off process tubes, cut and solder the ends. Remove pinch off tool, and leak check the process tube ends. 6.2.4 Special procedure in the case of compressor motor burnout. 1. Recover all refrigerant and oil from the system. 2.…
-
run at high speed
4. Apply "live" test cord probes on red wire and common terminal of capacitor. Motor should run at low speed. 5. Apply "live" test cord probes on each of the remaining wires from the speed switch or system switch to test intermediate speeds. 6.4 Capacitor A run capacitor is wired across the…
-
Characteristic of temperature sensor
7 Characteristic of temperature sensor Temp.℃ -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 Resistance KΩ 62.2756 58.7079 56.3694 52.2438 49.3161 46.5725 44 41.5878 39.8239 37.1988 35.2024 33.3269 31.5635 29.9058 28.3459 26.8778 25.4954 24.1932 22.5662 21.8094 20.7184 19.6891 18.7177 17.8005 16.9341 16.1156…
-
Trouble shooting PROBLEM No power display on panel or any one of the buttons failure. Remote control failure. POSSIBLE CAUSE Power failure Transformer (Discharge transformer before testing) REMEDY Check the power supplier if the power supplier is supplied to the unit. Check the power cord and…
-
Loose screws
Tighten them. Replace the motor if knocking sounds continue when running Worn bearings or loose, or the motor hums or noise appears to be internal while running. Voltage Check voltage. Call Supply Authority if not within limits. Check the wire connections, if loose, repair or replace the Wiring…
-
The inlet and outlet valve of the compressor is damaged,
making the low pressure connected with the high pressure. Compressor The refrigerating system can not produce high pressure and low pressure. Replace the compressor after checking for the reason. No cooling or heating. Heat sources Reduce if too many. No power Check the voltage. Call an electrician…
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.