USER'S MANUAL WIRED CONTOLLER XK117
-
“Original instructions”
IMPORTANT NOTE: Read this manual ca refully befo re installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
-
To Users
Thank you for selecting Sinclair’s product. Please read this instruction manual carefully before installing and using the product, so as to master and correctly use the product. In order to guide you to correctly install and use our product and achieve expected operating effect, we hereby instruct…
-
1 Installation
1.1 Dimension and Component of Wired Controller Figure 1-1 Dimension of Wired Controller (Unit:mm) Figure 1-2 Components of Wired Controller 1
-
Table 1.1.1 Introduction of Components
No. Name ① wired controller ② screw M4×25 ③ installing box of wired controller Quantity ④ junction box for installing inside the wall 1(prepared by user) 1.2 Installing Position and Requirements of Wired Controller (1) Please do not install the wired controller in the position where is wet or is…
-
(6) The wired controller should only be installed indoors, and its working temperature range is 0℃~50℃. 1.3 Installation of Wired Controller First to select the right signal wire of wired controller: 2–core signal wire (wire diameter>=0.75mm, length<30m, recommendable length is 8m). For installation…
-
(5) Buckle the panel of wired controller with the soleplate, then the installation is
finished. Figure 1-3 Sketch Map for Installation of Wired Controller 4
-
1.4 Disassembly of Wired Controller
Disassembly for wired controller is as below: Figure 1-4 Sketch Map for Disassembly of Wired Controller 2 Introduction to Display 2.1 Outline of Wired Controller Figure 2-1 Outline of Wired Controller 5
-
2.2 Liquid Crystal Display of Wired Controller
Figure 2-2 Liquid Crystal Display of Wired Controller 2.3 Instruction for Liquid Crystal Display of Wired Controller Table 2.3.1 Instruction for Liquid Crystal Display of Wired Controller Display Instruction of Display 1 Auto Automatic mode (under auto mode, the indoor unit will select its operating…
-
Display
No. Instruction of Display 7 Exchange 8 Silent Display when silent function is set (only display silent, no AT) 9 Health Display when health function is set 10 Absent Display when absent function is set 11 I-DEMAND 12 WIFI 13 14 WIFI function icon (reserve this function, no this function for wired…
-
Display Instruction of Display Clean Filter washing reminder 24 Save Display when energy-saving function is set 25 Defrost Defrosting status 26 Timer Display when timer status is set 27 Shield Shielding status 3 Instruction for Operation 3.1 Silkscreen of Buttons Figure 3-1 Silkscreen of Buttons 3.2…
-
Figure 3-2 ON Status
Figure 3-3 OFF Status 9
-
3.3 Mode Setting
Under power-on status, each time press the “MODE” button, the mode will switch circularly according to the following order, as shown in the figure. Figure 3-4 Mode Setting Note: Under auto mode, if the unit conducts auto cooling, then“ the unit conducts auto heating, then“ ” and “ ” and “ ” turn on…
-
Temperature setting range under cooling, dry, fan and heating mode is: 16℃~
30℃. The setting temperature cannot be adjusted under auto mode. Figure 3-5 Setting of Temperature 11
-
3.5 Setting of Fan Speed
Under power-on status, press “FAN” button, the fan speed will switch circularly according to the following order, as shown below. Figure 3-6 Setting of Fan Speed Note: (1) Under dry mode, the fan speed will automatically set as low speed, and the fan speed cannot be adjusted. (2) Under fan and auto…
-
simultaneously for 5 seconds, the up & down swing icon will flash, then switch for
simple swing and fixed swing is done. When it is set to be simple swing, under power-on status, press “SWING/ ENTER” button, the mode is activated, press the button again the mode is turned off. When it is set to be fixed swing, press “SWING/ENTER” button, the unit will circularly switch the swing…
-
power-off time. Press “TIMER” button, the setting is done. If before pressing “TIMER” button to finish the setting, press “MODE” button can switch to timer setting status, liquid crystal screen will display “xx.x hour”, and “ON” and “hour” icons flash simultaneously, then press “▲” or “▼” button to…
-
function is activated, the corresponding icon will turn bright. After finishing setting
one function, it will jump to the next functional setting. Specific instructions for setting of the following functions: (1) When setting air exchange function, there are a total 10 types of air exchange modes from 1 to 10, the temperature area will display the current mode, first press “▲” or “▼”…
-
(3) When setting washing remind function, the timer area will display 2–bit number
that means the pollution level, then press “▲” and “▼” buttons to select, and press “SWING/ENTER” button to confirm the setting. Conversion relation between the displayed pollution level and accumulative operating time are as the following list. After setting, when it reaches the washing time…
-
Pollution
Level 18 19 Accumulative operating time Pollution (hour) Level 9500 28 10000 29 Accumulative operating time Pollution (hour) Level 4600 38 5000 39 Accumulative operating time (hour) 900 1000 (4) When absent function is set, the setting temperature will display 8°C, the setting fan notch displays…
-
When low-temperature dry function is turned on, directly press “▲” button or
switch the mode can quit the function. 3.9.3 Setting of Child-lock Function Without error, under ON or OFF status of unit, press “▲” and “▼” buttons simultaneously for 5 seconds can enter into child-lock function, the liquid crystal screen will display “ ”; press “▲” and “▼” buttons simultaneously…
-
buttons other than “MODE” or when the unit receives remote control signal, it will
quit the inquiry status. If there is no any operation for 20 seconds, it will quit automatically. Note: When the outdoor ambient temperature sensor detects the same temperature for 12 hours, it will shield the display of outdoor ambient temperature sensor. 4 Display of Errors When error occurs in…
-
The following figure refers to the high-pressure protection under power-on
status. Figure 4-1 High-pressure Protection Table 4.1 Error Code List Error Code E1 Error Compressor high-pressure protection E2 Indoor anti-freeze protection E3 Compressor low-pressure protection, refrigerant lack protection, refrigerant collection mode E4 Compressor air discharge high-temperature…
-
Error Code
F0 Error Indoor ambient temperature sensor error F1 Evaporator temperature sensor error F2 Condenser temperature sensor error F3 Outdoor ambient temperature sensor error F4 Discharge temperature sensor error F5 Wired controller temperature sensor error C5 IDU jumper cap error EE IDU or ODU memory…
-
Error Code
P5 Error Over-current protection P6 Master control and driver communication error P7 Driver module sensor error P8 Driver module high temperature protection P9 Zero-crossing protection PA AC current protection Pc Driver current error Pd Sensor connection protection PE Temperature drift protection PL…
-
NOTE CONCERNING PROTECTION OF
ENVIRONMENT This product must not be disposed of via normal household waste after its service life, but must be taken to a collection station for the recycling of electrical and electronic devices. The symbol on the product, the operating instructions or the packaging indicate such disposal…