Installer manual
NIBE™ F135 Exhaust air module LEK IHB GB 1622-4 331432
-
Table of Contents
1 Important information Safety information 4 2 Delivery and handling 7 Transport Assembly Supplied components Removing the covers The exhaust air module design 10 4 Pipe and air connections 12 General pipe connections Dimensions and pipe connections Mounting Connecting to indoor module and air-water…
-
1 Important information
Safety information This manual describes installation and service procedures for implementation by specialists. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been…
-
Inspection of the installation
Current regulations require the heating installation to be inspected before it is commissioned. The inspection must be carried out by a suitably qualified person. ✔ Description Notes Signature Date Ventilation, exhaust air (page 15) Setting the ventilation flow Exhaust air filter Heating medium…
-
Contact information
AT KNV Energietechnik GmbH, Gahberggasse 11, 4861 Schörfling Tel: +43 (0)7662 8963-0 Fax: +43 (0)7662 8963-44 E-mail: mail@knv.at www.knv.at CH NIBE Wärmetechnik c/o ait Schweiz AG, Industriepark, CH-6246 Altishofen Tel: (52) Fax: (52) E-mail: info@nibe.ch www.nibe.ch CZ Druzstevni zavody Drazice…
-
2 Delivery and handling
15 - 40 mm Installation area Transport F135 should be transported and stored vertically in a dry place. Assembly ■ F135 is installed freestanding on brackets or a suitable flat surface. Noise from the circulation pump, fan and compressor can be transferred to the brackets or the surface that F135 is…
-
Supplied components
Location The kit of supplied items is placed on top of the product. Air connection Silencer LEK K LE Filter cartridge K LE 4-pin terminal block LEK 2 x bracket 6 x nuts 6 x screws 4 x washers 567 425 6-pin sensor connector vi n k ar oM LE K Drain hose Ø 20 mm LEK Circulation pump LEK L=2200 mm LEK…
-
Side panels
Removing the covers 1. 2. 3. 4. Front hatch Undo the screws at the edge. Twist the cover slightly outward. Move the side cover outwards and backwards. Assembly takes place in the reverse order. LEK K LE 1. Slacken off the screws for the securing plate above F135. 2. Slide the hatch upwards and pull…
-
3 The exhaust air module design
-
Pipe connections
Electrical components XL8 XL9 XL43 XL44 WM2 AA2 CA1 EB10 X 10 X 11 Connection, heating medium supply line Connection, return heating medium Connecting incoming air Connecting outgoing air Overflow water discharge1 Base card Capacitor Compressor heater PWM switch, circulation pump Terminal block…
-
4 Pipe and air connections
General pipe connections Pipe installation must be carried out in accordance with current norms and directives. F135 is only designed for upright installation. All connections are equipped with smooth pipe for compression ring couplings. Overflow water from the evaporator's collecting trough is…
-
Pipe dimensions
Dimensions and pipe connections Connection (mm) (mm) (mm) XL8 Heating medium out ext Ø XL9 Heating medium in ext Ø WM2 Overflow water discharge int Ø XL9 NIBE™ F135 WM2 XL8 Chapter 4 | Pipe and air connections 13
-
Installing brackets
Mounting The exhaust air module is wall-mounted using the brackets enclosed. The exhaust air module can also be placed on a suitable flat surface. NOTE Check that the mountings are located in the intended grooves on the exhaust air module. 1. Install the brackets together using the M6 screws and…
-
Connecting to indoor module
and air-water heat pump Installation exhaust air XL8 and XL9 are connected to the return line between the indoor module and the air-water heat pump. The particle filter must be installed before F135 to prevent dirt being deposited in F135. Install the shut-off valves outside F135 to facilitate any…
-
Docking NIBE air-water heat pump
The demand on F135 is controlled by the indoor module in the system. The pump and fan speed are also controlled from the menu in the indoor module. 16 Chapter 4 | Pipe and air connections NIBE™ F135
-
Docking NIBE F135, VVM, outdoor air, pool,
cooling F135 connected in air/water system with 4-pipe cooling. 4-pipe cooling must, in this instance, be connected between the outdoor air heat pump and F135. When there is also a pool, the F135 must be connected between 4-pipe cooling and the pool. The demand on F135 is controlled by the indoor…
-
LEK
General ventilation connections Ventilation installation must be carried out in accordance with current norms and directives. To prevent fan noise being transferred via the air ducts, it may be a good idea to install a silencer in the ducts, alternatively mount the enclosed silencer in F135. The…
-
Exhaust air duct /kitchen fan
Exhaust air duct (kitchen fan) must not be connected to F135. To prevent food vapour being transferred to F135 the distance between the kitchen fan and the exhaust air device must be considered. The distance should not be less than 1.5 m, but this can vary between different installations. Always use…
-
5 Electrical connections
General Indoor module Installation must be carried out in accordance with current standards and directives. Connect the indoor module input board (AA3-X4) to the four-pole terminal block X11:1 (15), X11:2 (14) and X11:3 (13). When working behind screwed covers, the circuit fuse must be removed or…
-
Optional connections
AUX inputs Switch for external blocking of compressor When external blocking of the compressor is desired, this can be connected to terminal block X13 on the base board (AA2). The compressor is disconnected by connecting a potential-free switch function to AUX2 (X13:3 och X13:4) (compressor). A…
-
6 Commissioning and adjusting
Preparations QM25 1. Check that the switch for the indoor module is in position " ". 2. Cut the power to F135. 3. Check that the filling valves are fully closed. Filling and venting Caution Insufficient venting can damage internal components in F135. Filling the climate system 1. Check that the…
-
Start-up and inspection
Start-up with NIBE Indoor module NOTE There must be water in the climate system before the switch in the indoor module is set to " ". NOTE The circulation pump must not be powered up until F135 is activated in the indoor module. 1. Start F135 by connecting the supply cable. 2. Set the indoor…
-
Setting ventilation (exhaust air)
Ventilation must be set according to applicable standards. Set the fan speed in menu 5.1.5. Even if ventilation is roughly set at installation it is important that a ventilation adjustment is ordered and permitted. NOTE Order a ventilation adjustment to complete the setting. Fan capacity Available…
-
7 Disturbances in comfort
In most cases, the indoor module notes a malfunction (malfunctions can lead to distruption in hot water comfort) and indicates this with alarms in the display. Info menu indoor module All the indoor module measured values are gathered under menu 3.1 in the indoor module menu system. Looking through…
-
Gurgling sound
■ Not enough water in the water seal. – Refill the water seal with water. ■ Choked water seal. – Check and adjust the condensation water hose. 26 Chapter 7 | Disturbances in comfort NIBE™ F135
-
8 Accessories
Top cabinet Top cabinet that conceals the ventilation ducts. 245 mm 445 mm Part no. 089 756 Part no. mm 385-635 mm Part no. 089 757 Part no. 089 758 NIBE™ F135 Chapter 8 | Accessories 27
-
9 Technical data
65-90 Dimensions and setting-out coordinates Ø125 220 Ø160 28 Chapter 9 | Technical data NIBE™ F135
-
Technical specifications
1x230 V Output data according to EN 14 511 Specified heating output (PH)1 kW COP1 Specified heating output (PH)2 3.87 kW COP2 Specified heating output (PH)3 Min fuse rating Enclosure class Refrigerant circuit Type of refrigerant Volume Compressor type Cut-out value pressostat HP Exhaust air module…
-
Miscellaneous
Dimensions and weight Width Depth Height (excluding connectors) Weight Part No. 30 Chapter 9 | Technical data mm mm mm kg - NIBE™ F135
-
Energy labelling
Information sheet Supplier NIBE Model F135 Temperature application Seasonal space heating energy efficiency class, average climate Rated heat output (Pdesignh), average climate Annual energy consumption space heating, average climate Seasonal space heating energy efficiency, average climate Sound…
-
Technical documentation
Model F135 Type of heat pump Air-water Exhaust-water Brine-water Water-water Low-temperature heat pump Yes No Integrated immersion heater for additional heat Yes No Heat pump combination heater Yes No Climate Average Temperature application Applied standards Rated heat output Prated Warm ƞs 114 %…
-
WIRING DIAGRAM NIBE F135
ELSCHEMA NIBE F135 051133 4 Electrical circuit diagram NIBE™ F135 Chapter 9 | Technical data 33
-
10 Item register
Item register A Accessories, 27 Adjusting ventilation, 19 Assembly, 7 C Commissioning and adjusting, 22 Filling and venting, 22 Preparations, 22 Start-up and inspection, 23 Connecting cold and hot water, 15 Connecting the climate system, 15 Contact information, 6 D Delivery and handling, 7 Removing…
-
WS name: -Gemensamt
WS version: a197 WS release date: 2016-05-31 14:06 Publish date: 2016-06-29 07:34 NIBE AB Sweden Hannabadsvägen 5 Box 14 SE-285 21 Markaryd info@nibe.se www.nibe.eu 331432