1. Software Installation
1.1 Running Environment OS: Windows7/Windows8/Windows10 Minimum configuration: CPU: Pentium 800MHz or above RAM: above 128MB Graphics card: Display mode above SVGA 16 bit color Hard drive: 83MB for full installation Recommended configuration: CPU: Pentium 1Ghz or above RAM: 1GB Graphics card…
-
After the installer completes the automatic check and installs the Microsoft.Net
Framework 4.6 component, the system enters the installation interface for the Midea Thermal Client. Click "Next" continuously to continue installation. 4
-
The installation completion confirmation window is displayed after installation ends. Click
"Finish" to confirm and close the window. 1.3 Starting the Software After the Midea Thermal Client is installed, it can be started as follows: Click the "Start" menu bar, select the MSS-Mthermal1.0 program group, and then click "MSS-Mthermal1.0" to start the software. After the program is installed…
-
1.4 Uninstall the Software
Select MSS-Mthermal1.0 under Add/Remove Programs in the control panel of the Windows system, and then click "Add/Remove" to uninstall the software. Click the "Start" menu bar, select the MSS-Mthermal1.0 program group, and then click "Uninstall MSS-Mthermal1.0" to uninstall the software. 2 Software…
-
2.1.2 Opening a Project
Click the "Open File" submenu under the "Project" menu to open a saved project. If the version of the product library used for the project to be opened is earlier than the product library version of current version, the system displays a list of all versions of the backup product libraries for one…
-
2.2 System Selection
Multiple systems for selection can be added for one project. Success marks will be added to the system list for projects that the system has selected. Systems can be selected through "ADD", "Delete" and "Copy" under the " Systems" menu. 2.2.1 Meteorological Parameters First define the dry bulb…
-
The humidity input mode can be set in "Unit" under the "Setting" menu. Either the dry bulb
temperature and humidity can be used to back-calculate the other humidity value. Click the expand button behind the "City" edit box to enter the meteorological database, and select the city: 9
-
When the meteorological parameters of system selection need to be entered manually,
uncheck the "Use meteorological database" box. After defining the meteorological parameters, click the "Appy" button to save data and enter the "Design" defining page. 2.2.2 Design Conditions Define the detailed operating parameters such as load and outlet water temperature for the selected system.…
-
System type
Define heating only or both heating and cooling for the selected product. If both heating and cooling are needed, define the corresponding cold and heat loads and cold and hot water temperatures. Selection method Set the selection method: "Terminals" means that the total load and water temperature…
-
"Load Input": No terminal can be selected. Enter the load and water temperature of the operating conditions. Water temperature range: When the water temperature of the terminal or operating conditions is defined, the system checks whether the entered water temperature is accurate. The input range…
-
actual heating capacity of the machine is its heating capacity pus the standby electric
heating capacity: Refrigerant piping length and level difference between outdoor unit and hydronic box If a split model is selected, the pipe length and IDU and ODU height difference needs to be defined. The machine capacity will be corrected during model selection. Here, the maximum value of the…
-
Safety factor
During selection, a safety factor can be selected for the system. The machine can be recommended as long as its capacity is in the load range of the selected system. Select the most appropriate machine. If the system implements both heating and cooling, a safety factor can be selected for the heat…
-
If there is no model meeting requirements when "Select" is clicked, the system will prompt
a parameter settings error. You need to go back to modify the selection conditions such as meteorological parameters and operating condition parameters. Common errors: 1) If the selected load is too high or too low and no machine meets requirements in the product library, the selected load size…
-
Click "Add" to open the auxiliary equipment library. Select the target auxiliary equipment
and add it to the system auxiliary equipment list. Click "Add Line" to add a line in the auxiliary equipment list. You can define corresponding data such as "Name", "Model", and "Size". 16
-
Click "Delete" to delete the auxiliary equipment on the currently selected line
2.2.5 System Diagram After model selection, the system principle diagram can be drawn on the "System Diagram" page. Select the appropriate typical system pattern for drawing from the diagram example. The drawn system diagram can be saved in picture format. 17
-
Recommended drawing
Click "Diagram Example" to display the typical diagram example. Select an appropriate application scenario to draw from it. After drawing is completed, the deleting, adding, marking and other operations can be performed on the surface. Check "With water tank" to list all the application scenarios…
-
таблицы и схемы — в просмотре
-
Text
Specify the text font, color and size, click "Text", click on the position to write text on the surface, and enter the content in the displayed text input window. Drawing lines Specify the line color, line width and line type, click the "Line" button to enter line drawing, and click in the drawing…
-
Select the drawn text, line, arrow or part and either click "Delete" or use the right-click
menu to delete it. Click "Undo" to restore the deleted content. Right-click menu Select a drawn graph, and edit it through the right-click menu: 1) Fill View: Zoom in/out to set the entire surface to the proper scale and cover the entire drawing area. 2) Original size: Restore the entire surface to…
-
create a new graph by copying
8) Arrange: The currently selected graph can be set to the top layer or bottom layer to change the occlusion relationship between graphs. Mouse operations 1) Move: Select a graph, and click to drag it and change its position. 2) Stretch: Select a line or arrow, move the cursor to its node (the…
-
Click the page turning button to turn the page and browse the content on each page
Click "Page setting" to set the page size and page margin of the exported report. Click "Export" to export a document in Excel, PDF, or Word format. 23
-
2.3 Software Settings
2.3.1 Language Settings Click "Language" under the "Setting" menu to switch the interface display language. Select a language from the language list. 2.3.2 Unit Settings Click "Unit" under the "Setting" menu to switch the interface display unit. Click "Recovery" to restore the unit settings to the…
-
2.4 Database Maintenance
2.4.1 Meteorologic Parameters Click "Meteorological" under the "Meteorological Database" menu to enter the meteorological parameter maintenance interface, where you can add, delete, or edit meteorological parameters. The software provides meteorological data of more than 6,000 cities around the…
-
Copying meteorologic parameters
Click under the city list to make a meteorologic parameter copy of the currently selected city. Modifying meteorologic parameters Click under the city list to display the editing interface, and edit the city's geographical location, dry bulb temperature in winter, relative humidity in winter, dry…
-
Deleting meteorologic parameters
Click under the city list to delete the meteorological data of the currently selected city. 2.4.2 Other Components Click "Other Components" under the menu to access the "Database" menu to open the auxiliary equipment maintenance interface, where you can add, delete, or edit auxiliary equipment.…
-
Copying auxiliary equipment
Click under the auxiliary equipment list to make a copy of the current auxiliary equipment. Editing auxiliary equipment Click under the auxiliary equipment to display the editing interface. The specification/model, size/dimension, material unit price and statistic unit of the auxiliary equipment can…
-
Deleting auxiliary equipment
Click under the auxiliary equipment list to delete the currently selected auxiliary equipment. Exporting auxiliary equipment Auxiliary equipment added by the user can exported to an Excel file for editing, and auxiliary equipment can also be added in Excel. Importing auxiliary equipment The…
-
2.4.3 Product Update
Click "Product Update" under the "Database" menu to compare the version of the product library used currently for the local computer with that of the product library in the server, and determine whether an update is needed. If an update is available, the latest product library can be downloaded from…
-
2.5 Help
2.5.1 Software Update Click "Software Update" under the "Help" menu to check whether an updated version is available for the current client software. If yes, the latest client program can be downloaded from the server. The system also automatically checks whether the software is updated when the…
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.