Product Manual
401 B – 04/11 E Date: November 2004 Supersedes: 401B - 02/10 D $LUWRZDWHUKHDWSXPSV 0+5· &RROLQJFDSDFLW\IURPWRN: +HDWLQJFDSDFLW\IURPWRN: +]UHIULJHUDQW+&)&+)&& McQuay is participating in the Eurovent Certification Programme. Product are as listed in the Eurovent Directory of Certified Products and on…
-
MHR - Air to water heat pumps
McQuay air to water heat pumps MHR equipped with scroll and reciprocating compressors are a new line of the proven range of air cooled units. They are manufactured by McQuay to satisfy the requirements of the consultants and the end user. McQuay MHR units are designed to minimise energy costs while…
-
- access password to prevent unauthorised access
- water temperature control - regulation of temperature set points - start-up sequence delay device - compressor functioning- fan on-off control - antifreeze control - antifreeze heater functioning - general alarm - differential pressure switch or pump failure alarm (opt.) By means of automatic…
-
4. The performance figures are based on Fouling factor of 0.044 m2°C/kW. In the event of different values, the correction coefficients indicated in Table 2 should be used. 5. The performance is influenced by air density. Table 3 gives the correction factors for the various altitudes above sea level.…
-
Table 3 – Altitude correction factors
Elvation above sea level (m) Barometric pressure (mbar) Cooling cap.correction factor Power input correction factor 0 1013 1,000 1,000 300 977 0,993 1,005 600 942 0,986 1,009 900 908 0,979 1,015 1200 875 0,973 1,021 1500 843 0,967 1,026 1800 812 0,960 1,031 Table 5 – Ethylene glycol and low ambient…
-
Physical data MHR ST 050.2÷110.2
“MHR ST” unit size Cooling capacity HFC 407C (1) Power input HFC 407C (1) Heating capacity HFC 407C (2) Power input HFC 407C (2) Cooling capacity HCFC 22 (1) Power input HCFC 22 (1) Heating capacity HCFC 22 (2) Power input HCFC 22 (2) Compressor type / N°of compressors N°of circuits N°of reduction…
-
Sound pressure levels MHR ST 050.2 ÷ 110.2
-
Electrical data MHR ST 080.2 ÷ 110.2
“MHR ST” unit size HCFC 22 Standard voltage Total compr. absorbed current nom. cond. (2) Max absorbed current each compressor (3) Max inrush current bigger compressor PW Total fans absorbed current nom. cond. (2) Total unit absorbed current nom. cond. (2) Max unit absorbed current (3) Max unit…
-
Standard ratings MHR ST 050.2 ÷ 080.2 HCFC 22
Unit size 050.2 055.2 060.2 065.2 070.2 075.2 080.2 Notes: Evap. leaving water temp. °C AIR AMBIENT TEMPERATURE - °C Cooling capacity kW Power input kW Cooling capacity kW Power input kW Cooling capacity kW Power input kW Cooling capacity kW Power input kW Cooling capacity kW Power input kW 170,1…
-
Standard ratings MHR ST 085.2 ÷ 110.2 HCFC 22
Unit size 085.2 090.2 095.2 100.2 110.2 Notes: Evap. leaving water temp. °C AIR AMBIENT TEMPERATURE - °C Cooling capacity kW Power input kW Cooling capacity kW Power input kW Cooling capacity kW Power input kW Cooling capacity kW Power input kW Cooling capacity kW Power input kW 310,1 317,5 324,9…
-
size
050.2 055.2 060.2 065.2 070.2 075.2 080.2 Evap. leaving water temp. °C Standard ratings MHR LN 050.2 ÷ 080.2 HCFC AIR AMBIENT TEMPERATURE - °C (*) 42 (*) Cooling capacity kW Power input kW Cooling capacity kW Power input kW Cooling capacity kW Power input kW Cooling capacity kW Power input kW…
-
Standard ratings MHR LN 085.2 ÷ 110.2 HCFC 22
Unit size 085.2 090.2 095.2 100.2 110.2 Evap. leaving water temp. °C AIR AMBIENT TEMPERATURE - °C (*) 42 (*) Cooling capacity kW Power input kW Cooling capacity kW Power input kW Cooling capacity kW Power input kW Cooling capacity kW Power input kW Cooling capacity kW Power input kW 297,7 304,8…
-
Heating capacity ratings MHR ST 050.2 ÷ 110.2 HCFC 22
Unit size 050.2 055.2 060.2 065.2 070.2 075.2 080.2 085.2 090.2 095.2 100.2 110.2 Leaving water temperature °C AIR AMBIENT TEMPERATURE - °C -5 Heating capacity kW Power input kW Heating capacity kW Power input kW Heating capacity kW Power input kW Heating capacity kW Power input kW Heating capacity…
-
Standard ratings MHR ST 050.2 ÷ 080.2 HFC 407C
Unit size 050.2 055.2 060.2 065.2 070.2 075.2 080.2 Notes: Evap. leaving water temp. °C AIR AMBIENT TEMPERATURE - °C Cooling capacity kW Power input kW Cooling capacity kW Power input kW Cooling capacity kW Power input kW Cooling capacity kW Power input kW Cooling capacity kW Power input kW 165,0…
-
Standard ratings MHR ST 085.2 ÷ 110.2 HFC 407C
Unit size 085.2 090.2 095.2 100.2 110.2 Notes: Evap. leaving water temp. °C AIR AMBIENT TEMPERATURE - °C Cooling capacity kW Power input kW Cooling capacity kW Power input kW Cooling capacity kW Power input kW Cooling capacity kW Power input kW Cooling capacity kW Power input kW 300,8 308,0 315,2…
-
size
050.2 055.2 060.2 065.2 070.2 075.2 080.2 Evap. leaving water temp. °C Standard ratings MHR LN 050.2 ÷ 080.2 HFC 407C AIR AMBIENT TEMPERATURE - °C (*) 42 (*) Cooling capacity kW Power input kW Cooling capacity kW Power input kW Cooling capacity kW Power input kW Cooling capacity kW Power input kW…
-
Standard ratings MHR LN 085.2 ÷ 110.2 HFC 407C
Unit size 085.2 090.2 095.2 100.2 110.2 Evap. leaving water temp. °C AIR AMBIENT TEMPERATURE - °C (*) 42 (*) Cooling capacity kW Power input kW Cooling capacity kW Power input kW Cooling capacity kW Power input kW Cooling capacity kW Power input kW Cooling capacity kW Power input kW 288,8 295,7…
-
Heating capacity ratings MHR ST 050.2 ÷ 110.2 HFC 407C
Unit size 050.2 055.2 060.2 065.2 070.2 075.2 080.2 085.2 090.2 095.2 100.2 110.2 Leaving water temperature °C AIR AMBIENT TEMPERATURE - °C -5 Heating capacity kW Power input kW Heating capacity kW Power input kW Heating capacity kW Power input kW Heating capacity kW Power input kW Heating capacity…
-
Water pressure drop
401 B – 04/11 E – pag. 19/24
-
401 B – 04/11 E – pag.20/24
-
401 B – 04/11 E – pag. 21/24
-
401 B – 04/11 E – pag.22/24
-
401 B – 04/11 E – pag. 23/24
-
We reserve the right to make changes in design and construction at any time without notice, thus the cover picture is not binding. McQuay partecipa al programma di Certificazione Eurovent. I prodotti interessati figurano nella Guida Eurovent dei Prodotti Certificati. McQuay is participating in the…