Инструкция на Кондиционеры серии LP
Кондиционеры серии LP-K3020HL/HA, LP-K3061HL/HA, LP-K3061ZL/ZA. Инструкция по монтажу и эксплуатации.
Смотрите также: Инструкция по монтажу и эксплуатации →
Загружаем документ…
Текст инструкции
-
Package
-
Contents
Functions 3 Product Specifications 6 Dimensions 7 Refrigeration Cycle Diagram 7 Wiring Diagram 8 Operation Details 9 Installation of Indoor, Outdoor Unit 16 Test Running 27 3-way Valve 29 Cycle Troubleshooting Guide 35 Electronic Parts Troubleshooting Guide 36 Electronic Control Device 39 Schematic…
-
Functions
Indoor Unit Power Switch ON/OFF Operation Mode Control • Cooling, Heating, Soft Dry, Fan Indoor Fan Speed Control • High, Low Jet Cool • Speed Cooling operates super high fan speed in cooling mode Energy Saving • Cooling Mode only Room Temperature control • Maintains the room temperature in…
-
Remote Control
Operation ON/OFF Cooling Operation Mode Heating Operation Mode Sot Dry Operation Mode • Intermittent operation of fan at low speed. Fan Operation • Used to circulate room air without cooling. Timer Control • OFF Timer (1, 2, 3, 7 hour) Jet Cool • Speed cooling operates super high fan speed in…
-
Outdoor Unit
Deice Control • De-ice PCB Outdoor Fan Speed Control • One speed Sensing Heat Exchanger Temperature • Heat exchanger temperature sensor (Thermistor) Sensing Discharge Pressure For Compressor • Discharge pressure sensor (High Pressure Switch) –5–
-
Product Specifications
MODEL UNIT ITEMS POWER SUPPLY Ø, V, Hz LP-K3061HL/HA LP-K3061ZL/ZA LP-K3020HL/HA 1, 220-240, 50 1, 220,60 COOLING CAPACITY Btu/hr 27,800 27,800 HEATING CAPACITY (Incl. elec. Heater) Btu/hr 27,800 + (2kw) 27,800 COOLING W 2,750 3,400 HEATING W 2,450 3,200 RUNNING COOLING A 12.5 16 CURRENT HEATING A…
-
Dimensions
Indoor Unit Outdoor Unit Air Outlet Vent Air Intake Vent (Rear) Remote Signal Receptor Air Inlet Vent Air Outlet Vent Refrigeration Cycle Diagram INDOOR UNIT CAPILLARY TUBE OUTDOOR UNIT LIQUID SIDE CHECK VALVE CAPILLARY TUBE BY PATH CAPILLARY TUBE HEAT EXCHANGER HEAT EXCHANGER GAS SIDE REVERSING…
-
Wiring Diagram
-
Operation Details
(1) The function of main control 1. Time Delay Safety Control 3min 3sec 30sec The compressor is ceased for 3 minutes to balance the pressure in the refrigeration cycle. (Protection of compressor) The indoor fan is ceased for 3 seconds to prevent relay noise. (Protection of fan relay and micro chip)…
-
5. Heating Mode Operation
The unit will operate according to the setting by the remote controller and the operation diagram is shown as following. Intake Air Temp. Setting Temp. +1°C (Compressor OFF) A A Setting Temp. (Compressor ON) Setting Temp. -1°C Hot Start minimum minimum minimum 10sec. 10sec. 10sec. minimum 10sec.…
-
5-1. Heating Mode Operation
The unit will operate according to the setting by the remote controller and the operation diagram is shown as following. Intake Air Temp. Setting Temp. +1°C (Compressor OFF) A A Setting Temp. (Compressor ON) Setting Temp. -1°C Hot Start minimum minimum minimum 10sec. 10sec. 1min Indoor Fan Speed OFF…
-
6. Hot-Start Control
• The indoor fan stops until the evaporator piping temperature will be reached to 28°C. • During heating operation, if piping temperatures fall below 26°C fan stops. • The operation diagram is as following. Maximum 1min INDOOR PIPE TEMP. 28°C 26°C INDOOR FAN SPEED OFF Selecting fan speed LOW…
-
8. Soft Dry Operation Mode
• During Soft Dry Operation, the compressor ON temperature is the setting temperature plus 2°C, the compressor OFF temperature is the setting temperature minus 1°C. • When the room temperature rises over the compressor ON temperature, the operation mode is switched to the Cooling mode. • When the…
-
12. Alarm mode display / only displayed while operating
CO : The sensor for sensing room temperature is open or short. C1 : The sensor for sensing piping temperature is open or short. 13. Jet Cool ❏ During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely high speed setting the room temp. automatically to 18°C. It is…
-
16. Function of changing set temperature when re-operation after stop
Operation is set the following condition when re-operation with start/stop button. 1.Operation mode. Cooling/soft dry mode Cooling mode Heating mode Heating mode 2. Setting the set temperature when cooling operation. Room temperature > Set temperature: to be set to the previous set temperature. Room…
-
Installation of Indoor, Outdoor Unit
1. Selection of the best location 1) Indoor unit • There should not be any heat source or steam near the unit. • There should not be any obstacles to prevent the air circulation. • A place where air circulation in the room will be good. • A place where drainage can be easily obtained. • A place…
-
2. Indoor Unit installation
3. Outdoor unit Installation The mounting floor should be strong and solid enough to prevent it from vibration. Drill the piping hole with 70mm diameter holecore drill at either the right or the left of indoor unit. The hole should be sightly slant to the outdoor side. Install the outdoor unit on…
-
■ Installation Method
1. Procedure No. Installation works Descriptions 1 Preparation of tools and installation parts Preparation of installation 2 Flaring the pipes To insert the flare nuts, mounted on the connection parts of both indoor and outdoor unit, onto the copper pipes. 3 Pipe bending To reduce the flow…
-
2. Preparation of installation parts and tools
No. Installation Parts, Tools 1 Flaring tool (Ø 6,35 - Ø 19,05) Flaring the pipes 2 Remear Remove burrs from cut edges of pipes. 3 Pipe cutter (MAX 35mm Copper pipe) Cutting the pipings 4 Wrench (H5, H4 hexagonal wrench) To open the service valve 5 Pipe bender Bending the pipings 6 Leak detector…
-
■ Piping of Indoor Unit
1. Preparation of piping Pipe cutter Cut the pipes and the cable • Use the accessory piping kit or the pipes purchased locally. • Measure the distance between the indoor and the outdoor unit. • Cut the pipes a little longer than measured distance. • Cut the cable 1.5m longer than the pipe length.…
-
2. Connection of piping
Move the indoor tubing and drain hose to the hole • Remove tubing holder and pull the tubing out of the chassis. Replace the tubing holder into original position Route the tubing and the drain hose staight backwards. Insert the connecting cable into the indoor unit through the hole. • Do not connect…
-
■ Connecting the Cable to Indoor Unit
• In order to protect cable, it should be inserted “Bushing Rubber”. • The inside and outside connecting cable can be connected after opening the inlet grille. Open the inlet grille manually. Connet the supplied cables to the connector on the control board. Close the inlet grille. Knock-out holes…
-
■ Connecting Piping and the Cable to Outdoor Unit
1) Connecting pipings to outdoor unit Align the center of the pipings and sufficiently tighten the flare nut with fingers. Finally tighten the flare nut with torque wrench until the wrench clicks. • When tightening the flare nut with torque wrench, ensure the direction for tightening follows the…
-
■ Power Supply and Wiring
The unit is completely wired internally at the factory according to general rule of electrical technology, but local rules, if they are required, should be complied with. UNIT 30K 1. Power supply H/P C/O Outside diameter 450/750V Conductor cross-sectional area 4.0mm2 450/750V 2.5mm2 11.8mm VOLTS…
-
■ Checking the Drainage and Form the Piping
1. Checking the Drainage Remove the inlet grille with your hands as shown (right and left) and pull in the direction indicated by the arrow. Check the drainage • Pour a glass of water into the drain pan. • Ensure if water flows drain hose of indoor unit. –25–
-
2. Form the Piping
;; ;; ;; ;; ;; ;; Wrap the connecting port of indoor unit with the insulation material and secure it with two Plastic Bands. (for the right Piping) Gas side piping • If you connect an additional drain hose, the end of the drain-outlet should be water, and fix it on the wall to avoid swinging in the…
-
Test running
1. PRECAUTIONS IN TEST RUN • The initial power supply must provide at least 90% of the rated voltage. Otherwise, the air conditioner should not be operated. Carry out the test run more than 5 minutes without fail. Caution (Test run will be cancelled 18 minutes later automatically) • The test run is…
-
CAUTION
After the confirmation of the above conditions, prepare the wiring as follows: 1) Never fail to have an individual power specialized for the air conditioner. As for the method of wiring, be guided by the circuit diagram pasted on the inside of control box cover. 2) Provide a circuit breaker switch…
-
3-way Valve
1. Pump down Liquid side Indoor unit 3-Way valve Open Outdoor unit Gas side Closed 3-Way valve Lo CLOSE CLOSE Purge the air • Procedure (6) Operate the air conditioner in cooling mode and stop it when the gaug e indicates 1kg/cm2g. (1) Confirm that both liquid side and gas side valves are set to the…
-
1) Re-airpurging
(Re-installation) Liquid side Indoor unit 3-Way valve Closed Outdoor unit Gas side Closed 3-Way valve Gas cylinder Lo R22 OPEN CLOSE • Procedure (6) Disconnect the charge set and the gas cylinder, and set the 2-way and 3-way valves to the open position. – Be sure to use a hexagonal wrench to operate…
-
2) Balance refrigerant of the 3-way valve
(Gas leakage) Liquid side Indoor unit Outdoor unit 3-Way valve Open 3-Way valve Open Gas side Lo OPEN CLOSE • Procedure (1) Confirm that both the liquid side and gas side valves are set to the back seat. (3) Open the valve (Lo side) on the charge set and discharge the refrigerant until the gauge…
-
2. Evacuation
(All amount of refrigerant leaked) Liquid side Indoor unit Outdoor unit 3-Way valve Open 3-Way valve Open Gas side Vacuum pump Lo OPEN CLOSE • Procedure (1) Connect the vacuum pump to the center hose of charge set center hose (3) Close the valve (Lo side) on the charge set, turn off the vacuum pump…
-
3. Gas Charging
(After Evacuation) Liquid side Indoor unit 3-Way valve Open Outdoor unit Gas side Open 3-Way valve Check valve Charging cylinder Lo (1) OPEN CLOSE • Procedure \ (1) Connect the charge hose to the charging cylinder. – Connect the charge hose which you disconnected from the vacuum pump to the valve at…
-
2) Heating Mode
(After Evacuation) Charging cylinder Lo (1) OPEN CLOSE Check valve Indoor unit Liquid side Open 3-Way valve Outdoor unit Gas side Open 3-Way valve • Procedure (1) Connect the charge hose to the charge cylinder. • Connect the charge hose which you disconnected from the vacuum pump to the valve at the…
-
Cycle Troubleshooting Guide
Trouble analysis 1. Check temperature difference between intake and discharge air and operating current. Temp. Difference Operating Current Temp. difference Current : approx. 0°C : less than 80% of rated current All amount of refrigerant leaked out Check refrigeration cycle Temp. difference Current…
-
Electronic Parts Troubleshooting Guide
-
2) No heating operation works
-
3) No heater operation works
-
Electronic control device
-
Schematic Diagram
-
Exploded View and Replacement Parts List
1. Indoor Unit 135310 147582 146812 147581-1 147581-2 137211-1 159830 268712 249310 137211-2 135313 152302 267110 266090 150170 –41–
-
Parts List (Indoor Unit )
-
Parts List (Outdoor Unit )
-
March, 2001 Printed in Korea
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.