Ducted Split-System Cooling LN-Series Product Data 3 ton, 4 ton, 5 ton Air Handling Unit Condensing Unit MODELS: LN-0320CC LN-0420CC LN-0520CC File Tab Position: 1 Rev. No.: 1 P/No.: 3828A30041M April, 2001 Printed in Korea
-
Features
Air Handlers • 4 way Convertibility-horizontal(Left & right), up-flow, down-flow. • Plastic drain Pan • High efficient Evaporator Coil • Galvanized Steel with painting • Washable and Anti-fungus Filter • Direct drive Motor • Multi-speed blower Condensing Units • Hi-Reliability Compressor • Insulated…
-
General Data
Table-1 Capacity Nominal ton Models ARI Net Cooling Capacity Electrical Data Voltage M.C.A(with standard motor) Power Input Performance Air Circulation EER Sound Rating Features Filter type Compressor Type Quantity Outdoor Coil Type Tube size(O.D) (Ton) Cooling Cooling Nominal CFM Cooling Cooling…
-
Table-2
Outdoor Indoor CFM 960 1080 1200 1320 1440 Outdoor Indoor CFM 960 1080 1200 1320 1440 DB WB DB TGC 30 31.3 32.5 33.6 31.6 32.9 34.2 35.3 32.2 33.6 34.9 36 33 34.4 35.7 36.8 33.2 34.6 36 37.1 DB WB DB SHC 17.3 21.6 26 28.9 18.5 23.2 27.9 31 20 25.1 30.2 33.6 20.1 25.1 30.3 33.6 20.6 25.8 31.1 34.5…
-
Table-3
Outdoor Indoor CFM 1280 1440 1600 1760 1920 Outdoor Indoor CFM 1280 1440 1600 1760 1920 DB WB DB TGC 41.2 42.9 44.6 46 43.3 45.2 46.9 48.4 44.2 46.1 47.9 49.4 45.2 47.1 48.9 50.5 45.5 47.5 49.3 50.9 DB WB DB SHC 23.7 29.7 35.7 39.7 25.4 31.8 38.3 42.5 27.5 34.4 41.4 46 27.5 34.5 41.5 46.1 28.2 35.4…
-
Table-4
Outdoor Indoor CFM 1600 1800 2000 2200 2400 Outdoor Indoor CFM 1600 1800 2000 2200 2400 DB WB DB TGC 49.7 51.9 53.8 55.6 52.3 54.6 56.6 58.5 53.4 55.7 57.8 59.7 54.6 57 59.1 61.1 55 57.4 59.6 61.5 DB WB DB SHC 28.6 35.8 43.1 47.9 30.7 38.4 46.3 51.4 33.2 41.6 50.1 55.6 33.3 41.6 50.2 55.7 34.1 42.7…
-
Table-5
CFM 900 1,000 1,100 1,200 1,300 1,400 1,500 1,600 Evaporator Fan Performance Data(LN-0320CC) High Speed ESP BHP 1.50 0.23 1.30 0.27 1.09 0.31 0.89 0.36 0.66 0.40 0.49 0.44 0.29 0.49 0.09 0.53 Mid Speed ESP 1.12 0.91 0.71 0.51 0.31 0.11 - BHP 0.21 0.26 0.32 0.37 0.43 0.48 - ESP 0.80 0.59 0.38 0.16…
-
Wet coil pressure drop
Table-8 UNIT SIZE LN-0320CC LN-0420CC LN-0520CC AIRFLOW(cfm) 1,000 1,200 1,400 1,600 1,400 1,600 1,800 1,700 1,800 2,100 2,300 Table-9 Unit Model No. LN-0320CC LN-0420CC LN-0520CC Table-10 MODEL LN-0320CC LN-0420CC LN-0520CC PRESSURE DROP(in.wg) 0.07 0.09 0.11 0.12 0.07 0.08 0.09 0.07 0.08 0.09 0.10…
-
Electrical Requirements
-
Electrical Requirements
Table-14 Evaporator Fan Motor 60 Hz No Standard indoor fan motor Volts Phase HP FLA LN-0320CC 0.46 5.0 LN-0420CC 0.46 5.0 LN-0520CC 0.46 5.0 MODEL Table-15 MODEL Compressor and Outdoor Fan Motor 60 Hz COMPRESSOR Phase HP FLA LRA No OUTDOOR FAN MOTOR Volts Phase HP FLA 3.0 19.0 0.12 1.2 1 4.0 19.2…
-
Wiring Diagram
-
Dimensions
-
Mechanical Specifications
Mechanical Specifications General Air handling units shall be completely factory asembled including coil drain pan, Blower motor and controls in an insulated casing that can be applied in horizontal or vertical configuration. Units shall be rated in accordance with ARI standard testing procedure…
-
Specification of Components