SERVICE
-
Table of Content
Available models ���������������������������������������������������� 2 PCB code���������������������������������������������������������������� 3 PCB boiler combustion reset ���������������������������������� 4 Check list first ignition �������������������������������������������� 5 User guide…
-
PCB Code
F FR PCB Code is placed close to the control panel and it is visible leaving metal cover City Class F City Class F City Class F City Class FR City Class FR City Class FR Digits 1st 2nd 3rd 4th 5th Value Aestethic Gas Type Power Hydraulic Not used PCB boiler combustion automatic check • On every…
-
PCB boiler combustion reset
FR PCB RESET = 2 parameters to factory setting a PCB code reset It can be done only in first 3 min after switching ON (in case switch OFF and ON again the boiler). It is advised for solving some puzzling problem on the field. • Boiler Mode OFF • Keep pressing for 15 sec buttons • When display shows…
-
Check list first ignition
F Installation done under country regulation in force done Verify the length of exaust flue system,and verify the installation of reducer for short system if needed (supplied with boielr’s documentation) Flues and air system No leakage between part of the system (extension, bends and flanges)…
-
User Guide
FR The front control panel: PUSHBUTTONS AND KNOBS Stand-by / Functioning mode At every press, the boiler switches its mode from summer or winter mode. to To set the CH system temperature. If the Outdoor Sensor Kit was installed, see also “Outdoor Sensor Kit” 00357 00 CH setting knob DHW setting knob…
-
Access to the inside of the boiler
FR ff Unscrew the casing fixing screws 1 and 2; ff pull the casing 3 outwards, then push it upwards (to unhooF it from the tongues 4) and remove it; ff unscrew the screw 5, then slide the control panel 6 upwards and overturn it downwards; ff after the regulations, close the boiler repeating…
-
00353 00 Boiler internal components 20 F - 25 F - 30 F Flue pressure switch Flue hood Expansion vessel Flame ignition/detection electrode Safety thermostat on system flow Temperature Sensor, system flow Motorized 3-way valve Automatic Venting Device (heating circuit, incorporated in the pump) 9…
-
00385 A 00 Boiler internal components 20 FR - 25 FR - 30 FR Flue pressure switch Flue hood Expansion vessel Flame ignition/detection electrode Safety thermostat on system flow Temperature Sensor, system flow Motorized 3-way valve Automatic Venting Device (heating circuit, incorporated in the pump) 9…
-
00360 00 Boiler internal components 35 F Flue pressure switch Flue hood Expansion vessel Flame ignition/detection electrode Safety thermostat on system flow Temperature Sensor, system flow Motorized 3-way valve Automatic Venting Device (heating circuit, incorporated in the pump) 9 Safety valve 3 bar…
-
00385 B 00 Boiler internal components 35 FR Flue pressure switch Flue hood Expansion vessel Flame ignition/detection electrode Safety thermostat on system flow Temperature Sensor, system flow Motorized 3-way valve Automatic Venting Device (heating circuit, incorporated in the pump) 9 Safety valve 3…
-
Hydraulic components F
00355 R M 1 Flue pressure switch 2 Flue hood 3 Expansion vessel 5 Safety thermostat on system flow 6 Temperature Sensor, system flow 7 Motorized 3-way valve 8 Automatic Venting Device (heating circuit, incorporated in the pump) 9 Safety valve 3 bar 10 Pump 11 Drain valve 12 Priority flow switch…
-
Hydraulic components FR
00384 00 M 13 15 R 1 Flue pressure switch 2 Flue hood 3 Expansion vessel 5 Safety thermostat on system flow 6 Temperature Sensor, system flow 7 Motorized 3-way valve 8 Automatic Venting Device (heating circuit, incorporated in the pump) 9 Safety valve 3 bar 10 Pump 11 Drain valve 12 Loss of water…
-
Electrical diagram F
L N NC NO 14.1 14.2 YG NC NO BU BU BK BK OG OG VT GN VT GN WH WH BU BU M0901 M0900 M0904 00354 INT 01 PE L N M0101 4 RD WH RD BK M0102 YG BN BU BU BN BN BU BN BU 23 BK BK SE TA 3 DHW 2 COM 1 HEA Flue pressure switch (*) 4 Flame ignition/detection electrode 5 Safety thermostat on system flow (*) 6…
-
Electrical diagram FR
L N NC 7 NO 13.1 13.2 YG NC WH WH BU BU (SP) 42 SP (ST) 12 6 ST BU BU BK BK OG OG VT GN VT GN WH WH BU BU M0901 M0900 M0904 003383 01 PE L N M0101 4 RD WH RD BK M0102 YG BN BU BU BN BN BU BN BU 19 SE TA 3 DHW 2 COM 1 HEA 10 BK BK NO 41 1 Flue pressure switch (*) 4 Flame ignition/detection electrode…
-
Heating system filling and pressuring
Once all system connections have been carried out, proceed with system filling. This operation should be made with care, respecting the following steps: ff Open the radiators venting devices; ff Check that the plug of the automatic air vent, incorporated in the boiler circulator, is unscrewed: if…
-
Heating system filling and pressuring
Once all system connections have been carried out, proceed with system filling. This operation should be made with care, respecting the following steps: 1 ff Open the radiators venting devices; ff Check that the plug of the automatic air vent, incorporated in the boiler circulator, is unscrewed: if…
-
DHW exchanger
18 SERVICE Manual City Class F-FR F FR Green Heating Technology
-
Dismounting & mounting
FLOW STAT tools suggested: allen Fey 4 mm - antiscale liquid for cleaning DISMOUNTING • discharge boiler water from both side (DHW and CH) • rotate safety 3 bar (D) 90* clockwise to show the right fixing screw • unscrew 2 fixing screws (F) • take out the DHW exchanger (H) • clean chemically or to…
-
Combustion components
20 SERVICE Manual City Class F-FR F FR Green Heating Technology
-
Dismounting & mounting
FR F BURNER AND FAN TOOLS tools suggested: wrench 24 mm - cross screwdriver - plastic brush - straight plier DISMOUNTING • leave electric supply and close the gas inlet by hand • remove the sealed chamber, unscrew the 5 screws (A) • disconnect the electrode wire • remove the insulating plate…
-
Gas valve
GAS VALVE TOOLS tools suggested: screw - nut CALIBRATION • Outlet pressure: Values written on User manual (1) • Inlet pressure: Net pressure must be: 20 mbar – MTN / 29- 37 mbar - LPG (2) • Vent Connection: Pressure compensation on sealed chamber (3) • • Coil modulator wires: MTN = 20 – 120 mA / LPG…
-
How to access parameters
storing Scrolling parameters FR Changing values 1. Boiler Mode OFF 2. Put both knobs at minimum value; then press RESET for 6 sec. until display is showing on the left «00» (n°of Parameter) and on the right «000» (Value of Parameter chosen). 3. Acting on left knob for scrolling Parameters. 4. Acting…
-
Standard Parameter for general uses
Suggested to not modify Parameters Param. Description F Range FR Fact. settings Note 0 : G20 1 : G31 0 : Standard Range 35 ÷ 80 °C F FR 01 Type Gas 0÷1 0 F FR 02 CH Temperature Range 0÷1 0 80% of Max 1 : Reduced Range 20 ÷ 45 °C F FR 03 Slow Ignition Fan Revolution 0 ÷ 80 kind of boiler F FR 04 Max…
-
Errors
Code F FR Error Find E01 RESET Description No flame ignition (after 3 attempts) FR Suggestion • Gas pressure inlet lower than required • Electrode position not correct High Water Temperature on Primary • PCB is not managing ignition • Safety Thermostat open; check water circulation and pressure…
-
Pump capacity diagram 6 00361 A 01 The graph is referred to the capacity available to the system. mod. 20F - 25F 1 speed 3 - 2 of the pump 1000 1200 1400 1600 pressure (m H2O) water flow (l/h) 6 00361 B 01 The graph is referred to the capacity available to the system. mod. 30F 1 speed 3 - 2 of the…
-
Pump capacity diagram
-
Gas type
U.M. City Class 20 F G20 G30/G31 City Class 25 F G20 G30/G31 City Class 30 F G20 G30/G31 City Class 35 F G20 G30/G31 II2H3+ II2H3+ II2H3+ II2H3+ Class Type B22 - C12 - C32 - C42 - C52 - C62 - C82 Working temperature range (min÷max) °C Max heat input (Qn) kW 21.0 20.5 25.7 25.5 30.0 29.0 30.0 29.0…
-
City Class 20 F
G20 G30/G31 City Class 25 F G20 G30/G31 City Class 30 F G20 G30/G31 City Class 35 F G20 G30/G31 Voltage / frequency (nominal voltage) 220÷240 / 50 (230V) 220÷240 / 50 (230V) 220÷240 / 50 (230V) 220÷240 / 50 (230V) Power consumption Level of protection IP X5D IP X5D IP X5D IP X5D Gas type U.M.…
-
Gas type
-
Gas type
U.M. City Class 20 F G20 G30/G31 City Class 25 F G20 G30/G31 City Class 30 F G20 G30/G31 City Class 35 F G20 G30/G31 Dimensions Width - Height - Depth mm Weight: net / gross kg see “Dimensions and connections” 27.5 / 29.7 30.2 / 32.6 30.8 / 33.2 34.6 / 37.0 Connections Hydraulic and gas connections…
-
ITALTHERM S.p.A. declines any responsibility for eventual printing and/or transcription errors in the present manual. In order to constantly improve its products, the company has the right to change features and data written in the present manual, at any time and without notice. www.italtherm.it…
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.