Инструкция на Настенные кондиционеры Fuji Electric серии RSW... (инструкции по монтажу)
Сплит-системы Fuji Electric RSW 13 V настенного типа. Инструкция по монтажу.
Смотрите также: Инструкция по монтажу →
Загружаем документ…
Текст инструкции
-
SPLIT TYPE ROOM AIR CONDITIONER
INSTALLATION MANUAL (PART NO. 9307698019-01) For authorized service personnel only. 77 ZXWARNING (1) For the room air conditioner to operate satisfactory, install it as outlined in this installation manual. (2) Connect the indoor unit and outdoor unit with the air conditioner piping and cords…
-
-SELECTING THE MOUNTING —
POSITION Decide the mounting position with the customer as follows: 1. INDOOR UNIT (1) Install the indoor unit level on a strong wall which is not subject to vibration. (2) The inlet and outlet ports should not be obstructed : the air should be able to blow all over the room. (3) Install the unit…
-
INDOOR UNIT
(1) Cut a 80 mm diameter hole in the wall at the position shown in (Fig. 5). {2) When cutting the wall hole at the inside of the wall hook bracket, cut the 980 mm hole within the range of the left and right center marks. When cutting the wall hole at the outside of the wall hook bracket, cut the…
-
@ For left piping and left rear piping, align the marks on the wall hook Fig. 8 om |
bracket and shape the connection pipe. = SUL ae $ Align the marks. @ Bend the connection piping at a bend radius of 70 mm or more and instal! +p — Энни | по more than 35 mm from the wall. <. Us ° @ After passing the indoor piping and drain hose through the wall hole, hang the indoor unit on the…
-
-FINISHING
(1) Heat insulate the connections between pipes. @ For rear, right, and bottom piping, butt the connection piping insulation material against the indoor unit piping and fasten it with seal A and vinyl tape so there is no gap. @ For left and left bottom piping wrap the piping with cloth tape within…
-
OUTDOOR UNIT
rOUTDOOR UNIT INSTALLATION @ = Set the unit on a strong stand, such as one made of concrete blocks to minimize shock and vibration. @ Do not set the unit directly on the ground because it will cause trouble. Connector cover removal @ Remove the two mounting screws. @ Put your hand on the back side…
-
ADDITIONAL CHARGE Refrigerant suitable for a piping length of 5 mis charged in the outdoor unit at the factory. When the piping is longer than 5 m, additional charging is necessary. For the additional amount, see the table below. Table 3 Pipe’... length |. * 5m 7m wm : Additional: ° > ° refrigerant…
-
ГТГ RUNNING
@ Perform test operation and check items 1 and 2 at the right. @ For the test operation method, refer to the operating manual. @ The outdoor unit, may not operate, depending on the room temperature. In this case, press the test run button on the rear of the remote control unit while the air…