Инструкция на Системы кондиционирования Daikin VRV 5 S
Системы кондиционирования Daikin VRV 5 S. Информационная брошюра.
Загружаем документ…
Текст инструкции
-
a sustainable future Lower CO2 equivalent and market-leading efficiencies CO Lower CO2 equivalents ErP 2021 COMPLIANT Industry-leading real life efficiencies Flexibility to take care of every room Variable Refrigerant Temperature
-
Creating a sustainable future
together Determined to reduce our environmental footprint, we aim to be CO₂-neutral by 2050. A circular economy, innovation and smart use – these are the stepping stones on our path. The time to act is now. Join us in creating a sustainable future for HVAC-R. INNOVATION CIRCULAR ECONOMY…
-
INNOVATION
2013 First R-32 split Ururu Sarara + + 2016 2017 Full range of optimised Split R-32 units First R-32 Sky Air + 2018 Launch of Daikin Altherma heat pump range on R-32 Full range of optimised Sky Air R-32 units Launch of HFO chillers + 2020 Launch of VRV 5 on R-32 Continuing our path to lower CO2…
-
The best VRV
we ever made Lower CO2, equivalent and market-leading versatility Top sustainability Reduced CO2 equivalent thanks to the use of R-32 refrigerant › R-32 Global Warming Potential (GWP) is 68% lower than R-410A › 15% less refrigerant charge Leading to a GWP reduction of 71% on system level! CO Single…
-
Maximum flexibility out of the box
With Shirudo technology your VRV 5 system takes care of small room applications in your building, without the need for any additional considerations and equipment in the field. › Fully compliant with the latest product standard IEC60335-2-40 (Ed.6) › Third party CB certified by a Notified Body (SGS…
-
Did you know …
different standards regarding F-gas safety regulations exist? Two standards are applied to cover the safety regulations of refrigerants: › EN378:2016: the generic standard on refrigerants covering the toxicity of the refrigerant (class A or B) › IEC60335-2-40 (Ed.6): the specific heat pump product…
-
Taking care
of every room in your building With Shirudo technology your VRV 5 system takes are of any room down to 10 m², without the need for time consuming selections and additional measures to be taken in the field. With all measures factory-integrated, VRV 5 is the most flexible and quick to design, fully…
-
VRV 5 outdoor unit overview
Capacity class (kW) Air – cooled heat pump Model UNIQUE VRV 5 S-series Product name Lower CO2 equivalent and market-leading flexibility › Compact single fan design saves space and is easy to install › Market-leading serviceability and handling › Reduced CO2 equivalent thanks to the use of lower GWP…
-
Ceiling mounted
cassette units Concealed ceiling units Wall mounted unit FXZA-A FXDA-A FXSA-A FXAA-A During absence, indoor comfort levels can be maintained Fan only The air conditioner can be used as fan, blowing air without cooling or heating Auto cleaning filter The filter automatically…
-
Next generation
New asymmetric fan design › Two high ESP settings › Low sound levels Compact dimensions › Easy to transport thanks to compact size and single-fan design New casing design with 4 handles for easy carrying Specially designed grille Refrigerant cooled PCB › Low pressure drop › No risk for accidental…
-
VRV 5 S-series 460 mm 1.100 mm Lower CO2 equivalent and market-leading flexibility 869mm RXYSA-AV/AY1 Only 869mm level difference between indoor units high! 120 m longest pipe length 40 m longest length after first branch 15 m 50 m level difference between indoor and outdoor units › Reduced CO2…
-
The most comfortable cassette
just got better New round flow cassette › Bigger louvers and new sensor logic further improves equal air distribution in the room › Widest ever choice in panels for cassette units, with up to 8 different panels Black auto cleaning panel Black designer panel Full white standard panel White designer…
-
NEW FXFA-A
Round flow cassette 360° air discharge for optimum efficiency and comfort › Optimised design for R-32 refrigerant › Optional automatic filter cleaning results in higher efficiency & comfort and lower maintenance costs. › Two optional intelligent sensors improve energy efficiency and comfort › Widest…
-
NEW FXZA-A
Fully flat cassette Unique design in the market that integrates fully flat into the ceiling › Optimised design for R-32 refrigerant › Fully flat integration in standard architectural ceiling tiles, leaving only 8mm › Remarkable blend of iconic design and engineering excellence with an elegant finish…
-
Auto cleaning filter for
concealed ceiling units The unique automatic cleaning filter achieves higher efficiency and comfort with lower maintenance costs airflow direction Reduce running costs › Automatic filter cleaning ensures low maintenance costs because the filter is always clean UNIQUE Patents pending Efficiency…
-
NEW FXDA-A
Slim concealed ceiling unit rear suction Slim design for flexible installation › Optimised design for R-32 refrigerant › 10 class unit especially developed for small or well-insulated rooms, such as hotel bedrooms, small offices, etc. › Compact dimensions, can easily be mounted in a ceiling void of…
-
NEW FXSA-A
Concealed ceiling unit with medium ESP Slimmest yet most powerful medium static pressure unit on the market outblow rear suction › Optimised design for R-32 refrigerant › Slimmest unit in class, only 245mm (300mm built-in height) and therefore narrow ceiling voids are no longer a challenge bottom…
-
NEW FXAA-A
Wall mounted unit For rooms with no false ceilings nor free floor space › Optimised design for R-32 refrigerant › Flat, stylish front panel blends easily within any interior décor and is easier to clean › Can easily be installed in both new and refurbishment projects › The air is comfortably spread…
-
Options & accessories Outdoor units
VRV S-series RXYSA-AV1/AY1 Heater tape kit - Optional electrical heater to guarantee trouble-free operation in extremely cold and humid climates (one per outdoor unit needed) EKBPH250D Adapters External control adapter for outdoor unit - Allows to activate Low Noise Operation and three levels of…
-
Concealed ceiling units (duct units)
Wall mounted units Medium ESP • FXSA15-32A FXSA40-50A FXSA63-80A FXSA100-125A FXSA140A FXAA-A BRC4C65 BRC4C65 BRC4C65 BRC4C65 BRC4C65 BRC7EA630 / BRC7EA628 • • • • • • (mandatory for R-32) • • (18) (18) • • • • • • • • • • • • • • • • (mandatory for R-32) • • (18) (18) • • • • • • • • • • • • • • •…
-
Technical drawings
-
(480~490) holes for anchor bolts M12 1100 Gas pipe connection ·Ø22.2· brazing 2 Liquid pipe connection ·Ø9.5· brazing 3 Service port (in the unit) 4 Electronic connection and grounding terminal ·M5· (in the switch box) 5 Refrigerant piping intake 6 Knockout hole. 7 Knockout hole. 8 Drain outlet…
-
RXYSA-AY1
-
таблицы и схемы — в просмотре
-
RXYSA-AY1
Stacked units (max.2 levels) ( Stacked units (max.2 levels) ( ) ) A2 A1 ≥100(1) A2 ≥100(1) ≥500 A2 ≥500 ≥1000 B1 ≥300 B2 ≥100(1) B2 ≥100(1) ≥100(1) ≥1000 B2 ≥100(1) ≥300 (1) A1=>A2 For better serviceability, use a distance ≥250 mm (A1) If there is danger of drainage dripping and freezing between the…
-
FXFA-A WITH STANDARD PANEL
FXFQ-B Notes 1. Location of nameplate The unit nameplate is located on the control box cover. The decoration panel nameplate is located on the piping-side panel frame, under the corner cover. 2. When installing optional accessories, refer to their respective documentation. 3. Make sure the distance…
-
FXFA-A WITH DESIGNER PANEL
FXFQ-B Notes 1. Location of nameplate The unit nameplate is located on the control box cover. The decoration panel nameplate is located on the piping-side panel frame, under the corner cover. 2. When installing optional accessories, refer to thei r respective documentation. 3. Make sure the distance…
-
FXZA-A
FXZQ-A Decoration panel 585-595 (Ceiling opening space) Fresh white N9.5 Daikin Silver 300 or less 533 (Suspension position) Service access panel 450x450mm or more 533 (Suspension position) Pipe connection side 585-595 (Ceiling opening space) BYFQ60C2W1W BYFQ60C2W1S Drain connection side A Arrow…
-
20 or more
240 or more 300 or more (Service space) (Suspension bolt pitch) 300 or more (Service space of installation box for adapter PCB) 20 or more FXDA10-32A FXDQ15-32A 400 or more (In case of bottom-suction) Ceiling Service space 16x ø 4,7 holes 300 or more Adjustable (0-600) (Suspension bolt pitch)…
-
FXDA63A
300 or more 300 or more (Service space of installation box for adapter PCB) (in case of bottom suction) 240 or more 400 or more 20 or more 20 or more (Suspension bolt pitch) (Service space) Ceiling 26 x dia. 4.7 holes Service space (Suspension bolt pitch) View A Inspection door (ceiling opening) 300…
-
FXSQ15-32A
FXSA15-32A 25 2x65=130 KJ KC KH KE or more Service space Suspension bolt Fresh air intake position 109 Ø100 (Knockout hole.) 170 ARROW VIEW A 365 32 KF 179.2 50 500 or more Service space KD Suspension position 4x65=260 KA 210 2x140=280 126 P.C.D. 4-M4 (CLASS 2) 50 KK 630 Suspension position KB Item…
-
FXSQ63-80A
-
FXSQ140A
-
FXAQ15-32A
FXAA15-32A Hole for piping Hole for piping About 365 Drain hose About 420 Gas pipe About 460 Liquid pipe 30 or more Dimensions of fully opened front panel 450 Indoor air flow 290 Front grille fixing screws Front panel Front grille Heating 120 or less For installation in high places 50 or more…
-
FXAA63A
FXAQ63A About 365 Drain hose About 420 Gas pipe About 460 Liquid pipe Hole for piping Hole for piping 30 or more Required space Hole for piping 90 or more Required space Hole for piping Dimensions of fully opened front panel 2500 or more Indoor air flow Location of nameplate Front grille fixing…
-
Definitely the best VRV
we ever made 37
-
Creating
a sustainable future together Determined to reduce our environmental footprint, we aim to be CO₂-neutral by 2050. A circular economy, innovation and smart use – these are the stepping stones on our path. The time to act is now. Join us in creating a sustainable future for HVAC-R. Sowing the seeds of…
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.