Инструкция на Реверсивные тепловые насосы 'воздух-вода' Carrier серии 30RQ
Реверсивные тепловые насосы 'воздух-вода' со спиральными компрессорами Carrier серии 30RQ теплопроизводительностью 17,0 - 39,0 кВт. Технические характеристики.
Загружаем документ…
Текст инструкции
-
Air-Cooled Liquid Chillers/Air-to-Water Heat Pumps
www.eurovent-certification.com www.certiflash.com Quality Management Systems 30RB/RQ 017-033 Nominal cooling capacity 16-33 kW Nominal heating capacity 16-33 kW The Aquasnap liquid chiller/heat pump range was designed for commercial applications such as the air conditioning of offices and hotels…
-
Easy and fast installation
■■ Integrated hydronic module High-pressure centrifugal water pump Access panels, sizes 017-021 Economical operation ■■ Increased energy efficiency at part load Eurovent energy efficiency class A and B (in accordance with EN14511-3:2011) in cooling and heating mode. The exceptionally high energy…
-
Pro-Dialog+ control
Pro-Dialog+ combines intelligence with operating simplicity. The control constantly monitors all machine parameters and precisely manages the operation of compressors, expansion devices, fans and of the water heat exchanger water pump for optimum energy efficiency. Pro-Dialog+ interface…
-
Options and accessories
Options Description Advantages Use Integrated water fill system Designed for units with hydronic module Unit adds the water into the circuit 30RB/RQ 017-033 Unit without hydronic module Power supply without neutral Accessories JBus gateway BacNet gateway LonTalk gateway Remote interface Integrated…
-
Hydronic module
The hydronic module reduces the installation time. The unit is factory-equipped with the main hydronic components required for the installation: screen filter, water pump, expansion tank, safety valve and pressure gauge. The hydronic module is integrated into the unit without increasing its…
-
Physical data, 30RB units
30RB Air conditioning application as per EN14511-3:2011* Condition 1 Nominal cooling capacity kW EER kW/kW Eurovent class, cooling ESEER kW/kW Condition 2 Nominal cooling capacity kW EER kW/kW ESEER kW/kW Air conditioning application Condition 1 Nominal cooling capacity kW EER kW/kW ESEER kW/kW…
-
Physical data, 30RQ units
30RQ Air conditioning application as per EN14511-3:2011* Condition 1 Nominal cooling capacity kW EER kW/kW Eurovent class, cooling ESEER kW/kW Condition 2 Nominal cooling capacity kW EER kW/kW ESEER kW/kW Air conditioning application** Condition 1 Nominal cooling capacity kW EER kW/kW ESEER kW/kW…
-
Electrical data, 30RB/RQ units
30RB/RQ 017 Power circuit Nominal power supply V-ph-Hz 400-3-50 Voltage range V 340-440 Maximum start-up current (Un)* A Maximum operating power input** kW 7.8 9.1 11 13.8 Control circuit supply Unit power factor at nominal capacity** A Nominal unit operating current draw*** A Maximum operating…
-
Sound spectrum, 30RB/RQ units
dB dB dB dB Operating limits Flow rate, l/s 017 0.45 Minimum Maximum* Maximum** 0.57 1.52 1.42 0.67 0.87 30RQ Flow rate, l/s 017 0.45 1.39 1.96 2.18 1.43 1.72 Maximum* Maximum** 0.57 1.52 1.42 0.67 0.87 2.18 2.29 4000 Sound power levels 8000 dB(A) dB(A) dB(A) dB(A) 1.26 Minimum 1.39 2000 30RB/RQ…
-
Available static system pressure
-
Dimensions/clearances
-
таблицы и схемы — в просмотре
-
Cooling capacities in accordance with EN14511-3 : 2011
-
таблицы и схемы — в просмотре
-
Heating capacities in accordance with EN14511-3 : 2011
-
Variable water flow system (VWF)
Variable water flow is a hydronic control function package that permits control of the water flow rate. The VWF not only ensures control at full load, a specific Carrier algorithm linked to an electronic frequency converter also continuously modulates the flow rate to minimise pump consumption at…
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.