Installation and maintenance manual
CLS/CLC/CLH 182 ÷ 602 English 41 140 kW Air cooled water chillers, air cooled condensing units and air-to-water reverse cycle heat pumps 46 152 kW IOM CLSCH-N.1GB Date : November 2005 Supersedes : None
-
Pagina 1 English Table of contents Table of contents 1 FOREWORD 5 START-UP 1.1 Introduction 3 5.1 Preliminary check 19 1.2 Warranty 3 5.2 Start-up 19 1.3 Emergency stop/Normal stop 3 5.3 Checking the operation 20 1.4 An introduction to this manual 3 5.4 Delivery to the customer 20 2 SAFETY 6 CONTROL…
-
Pagina 2 Table of contents 9 MAINTENANCE 9.1 General requirements 75 9.2 Planned maintenance 75 9.3 Refrigerant charge 76 9.4 Compressor 76 9.5 Condenser 76 9.6 Fans 76 9.7 Dehydrating filter 77 9.8 Sight glass 77 9.9 Thermostatic expansion valve 77 9.10 Evaporator 10 TROUBLESHOOTING SPARE PARTS…
-
Pagina 3 1 FOREWORD 1.1 Introduction Itelco-Clima units, manufactured to state-of-the-art design and implementation standards, ensure top performance, reliability and fitness to any type of airconditioning systems. These units are designed for cooling water or glycoled water (and for water heating…
-
Pagina 4 Safety 2 SAFETY 2.1 Foreword These units must be installed in conformity with the provisions of Machinery Directive 98/37/EC, Low Voltage Directive 73/23/EC, Pressure Vessels Directive 97/23/EC, Electromagnetic Interference Directive 89/336/EC, as well as with other regulations applicable…
-
Pagina 5 OPERATOR: means a person authorised by the owner to do on Itelco-Clima unit all the regulation and control operations expressly described in this manual, that must be strictly complied with, without exceeding the scope of the tasks entrusted to him. ENGINEER: means a person authorised…
-
Pagina 6 Safety h check the proper grounding of the unit before start- up h check all the electrical connections, the connecting cables, and in particular the insulation; replace worn or damaged cables h periodically check the board’s internal wiring h do not use cables having an inadequate section…
-
Pagina 7 English Safety 2.7 Safety plates The labels below will be affixed to each unit in the indicated point: Identification of the refrigerant - External door TENERE SU QUESTA LINEA GANCIO DI SOLLEVAMENTO R407C KEEP LIFT HOOK ON THIS LINE Gravity centre - Base Identification of the unit Outside…
-
Pagina 8 ATTENZIONE INSERIRE LE RESISTENZE DI RISCALDAMENTO OLIO ALMENO 12 ORE PRIMA DI OGNI AVVIAMENTO (SE PREVISTE). 881000215/B Safety PRIMA DELLA MESSA IN TENSIONE ASSICURARSI CHE LE VITI DEI CIRCUITI ELETTRICI SIANO SERRATE COMPLETAMENTE. WARNING ENERGIZE THE CRANCKCASE HEATER FOR AT LEAST 12…
-
Pagina 9 2.8 English Safety Safety regulations Refrigerant data Safety data: R407C, R134a Toxicity Low Contact with skin If sprayed, the refrigerant is likely to cause frost burns. If absorbed by the skin, the danger is very limited; it may cause a slight irritation, and the liquid is degreasing.…
-
Pagina 10 Safety General precautions Do not inhale concentrated vapours. Their concentration in the atmosphere should not exceed the minimum preset values and should be maintained below the professional threshold. Being more weighty than the air, the vapour concentrates on the bottom, in narrow…
-
Pagina 11 English Safety Refrigerant oil data Safety data: Polyolester oil (POE) Classification Not harmful Contact with skin May cause slight irritation. Does not require first aid measures. It is recommended to follow usual personal hygiene measures, including washing the exposed skin with soap…
-
Pagina 12 Transport, Lifting and Positioning 3 TRANSPORT, LIFTING AND POSITIONING Refrigerators are supplied assembled (apart from standard antivibrating rubber supports, that will be installed on site). The equipment are full of refrigerant and oil (except to the condensing unit), in the quantity…
-
Pagina 13 English Transport, Lifting and Positioning For lifting operations, use only tools and material fit for this purpose, in accordance with accident-prevention regulations. During the lifting and handling of the unit, be careful not to damage the finned pack of the coils positioned on the…
-
Pagina 14 Installation 4 INSTALLATION 4.1 Positioning of the unit Before installing the unit, make sure that the structure of the building and/or the supporting surface can withstand the weight of the appliance. The weights of the units are listed in Chapter 8 of this manual. 4.2 Installation of…
-
Pagina 15 The capacity of the expansion vessel must allow for an expansion of at least 2% of the volume of the fluid in the circuit (evaporator, piping, user circuit and standby tank, if any). The expansion vessel needs not be isolated, because no water can circulate inside it. h A flow meter, to…
-
Pagina 16 Installation Legends: I: S: Fl: Pressure gauge connection Gate valve Flow meter Before filling the circuit, it is important to check that it is free from any foreign matter, sand, gravels, rust, welding deposits, waste and other materials that may damage the evaporator. When cleaning the…
-
Pagina 17 The company in charge of the installation shall conform to the standards applicable to outdoor electrical connections. Before connecting the power supply lines, check that the available voltage value does not exceed the range specified in the Electric Data (Chapter 8). Itelco-Clima may not…
-
Pagina 18 Installation Terminal box CLS/CLH/CLC STD-LN-ELN-HPF-HT Terminal box CLH EH REMOTE START/STOP SWITCH (SRS) (COMMON) REMOTE SEL. OF COOLING/HEATING MODES FLOW METER EXTERNAL INTERLOK/PUMP CONSENT COMMON ANTIFREEZE CONTROL (MAX 0,5 AMP 230 Vac) EXTERNAL PUMP CONTROL (MAX 0,5 AMP 230 Vac)…
-
Pagina 19 5 START-UP The unit must be started for the first time by personnel suitably trained by one of ItelcoClima’s Authorised Service Centre. Failure to meet this requirement will immediately void the warranty. The operations carried out by Itelco-Clima personnel are limited to the start-up of…
-
Pagina 20 Start-up 5.3 Checking the operation Check the following: h The temperature of the water entering the evapo- rator. h The temperature of the water leaving the evapora- tor. h The level of the water flow rate in the evaporator, if possible. h The current absorption upon the start of the com…
-
Pagina 21 6 CONTROL The standard equipment of the units includes a control and monitoring electronic system, which ensures the deployment of all control, monitoring and alarm functions of these units. 6.1 General information The system consists of an electronic card and a panel terminal. Control…
-
Pagina 22 Control 6.3 Display The display allows to indicate, in particular: h The temperature of the water entering the machine in Celsius degrees h The alarm code, if an alarm has been activated LED’s: 1 Displays the “Heating” mode of operation 2 Displays the “Cooling” mode of operation 3 Selects…
-
Pagina 23 6.4 Start-up Once you have checked that the electrical connections are workmanlike, the unit can be started as follows: – Hold down the ON-OFF button for 2 seconds to turn on the regulator. – If, upon start-up, only the decimal point appears on the screen of the display, the regulator is…
-
Pagina 24 Control 6.6 Main alarms Code E00 E01 E02 E03 E04 E05 E06 E07 E21 E22 E23 E25 E26 E27 E40 E41 E42 E44 E45 E46 Description Remote Off High pressure 1 Low pressure 1 Thermal protection, compressor 1 Thermal protection, fans Antifreeze, circuit 1 Failure of leaving water sensor 1 Failure of…
-
Pagina 25 7 GENERAL DESCRIPTION 7.1 Introduction The CLS/CLH units are water chillers/air - water heat pumps with hermetic scroll compressors with double refrigeration circuit. These units are fit for cooling and heating the water necessary for each air-conditioning application and other types of…
-
Pagina 26 General Description 7.5 Water heat exchanger 7.7 Fans The evaporators are of stainless steel plate type. Fans are of directly coupling propeller type, provided with aluminium blade with wing profile. Each fan is provided with galvanised steel accidentprevention guard. Their thermal…
-
Pagina 27 English General Description CLH refrigeration diagram REFRIGERATION PLANT Components of the refrigeration system: 1 Compressors C1 / C2 2 Silencer (ELN only) 3 Reversing valve 4 Delivery cock 5 PED safety valve 6 Coil 7 Liquid cock 8 Filter 9 Liquid sight glass 10 Check valve 11…
-
Pagina 28 General Description 7.8 Electric power supply and control system The control compartment contains and electronic card with keyboard and a display for working parameters, alarms, if any, and operating blocks. It is complete with remote control switches and protection fuses for the motors of…
-
Pagina 29 8 English Technical data TECHNICAL DATA 8.1 Pressure drops in the evaporator PRESSURE DROPS IN THE EVAPORATOR CLS 182 CLS 202 CLS 242 CLS 302 CLS 352 52.3 41.5 29.4 21.0 12.5 l/s 1.4 1.8 2.2 2.5 3.1 Nominal flow rate l/s 1.9 2,6 3,1 3.5 4.3 Max. water flow rate l/s 3.2 4.3 5.2 5.9 7.2 Min.…
-
Pagina 30 Technical data 8.2 Technical data CLS STD 182 202 Number of circuits 2 2 Number of steps 2 2 % 50/100 50/100 kg 7.0 7.0 Scroll 2 Power supply Capacity control steps 50/100 50/100 43-57/100 9.0 10.0 12.0 Scroll Scroll Scroll Scroll V/ph/Hz 242 400/3/50 Refrigerant Type Charge (1) R407C…
-
Pagina 31 English Technical data CLS STD 402 502 Number of circuits Number of steps % 50/100 50/100 43-57/100 50/100 kg 12.0 17.0 18.5 20.0 Scroll Scroll Scroll Scroll Power supply Capacity control steps 552 V/ph/Hz 602 400/3/50 2 Refrigerant Type Charge (1) R407C Compressors Type Number Start-up…
-
Pagina 32 Technical data CLS LN 182 202 Number of circuits 2 2 Number of steps 2 2 % 50/100 50/100 kg 7.0 7.0 Scroll 2 Power supply Capacity control steps 50/100 50/100 43-57/100 9.0 11.0 12.0 Scroll Scroll Scroll Scroll V/ph/Hz 242 400/3/50 Refrigerant Type Charge (1) R407C Compressors Type Number…
-
Pagina 33 English Technical data CLS LN 402 502 Number of circuits Number of steps % 50/100 50/100 43-57/100 50/100 kg 13.0 17.0 18.5 20.0 Scroll Scroll Scroll Scroll Power supply Capacity control steps 552 V/ph/Hz 602 400/3/50 2 Refrigerant Type Charge (1) R407C Compressors Type Number Start-up…
-
Pagina 34 Technical data CLS ELN 182 202 Number of circuits 2 2 Number of steps 2 2 % 50/100 50/100 kg 7.5 7.5 Scroll 2 Power supply Capacity control steps 50/100 50/100 43-57/100 9.0 11.0 12.0 Scroll Scroll Scroll Scroll V/ph/Hz 242 400/3/50 Refrigerant Type Charge (1) R407C Compressors Type Number…
-
Pagina 35 English Technical data CLS ELN 402 502 Number of circuits Number of steps % 50/100 50/100 43-57/100 50/100 kg 12.0 17.0 18.5 20.0 Scroll Scroll Scroll Scroll Power supply Capacity control steps V/ph/Hz 552 602 400/3/50 2 Refrigerant Type Charge (1) R407C Compressors Type Number Start-up…
-
Pagina 36 Technical data CLS HPF 182 202 Number of circuits 2 2 Number of steps 2 2 % 50/100 50/100 kg 7.5 7.5 Scroll 2 Power supply Capacity control steps 50/100 50/100 43-57/100 9.0 11.0 12.0 Scroll Scroll Scroll Scroll V/ph/Hz 242 400/3/50 Refrigerant Type Charge (1) R407C Compressors Type Number…
-
Pagina 37 English Technical data CLS HPF 402 502 Number of circuits Number of steps % 50/100 50/100 43-57/100 50/100 kg 12.0 17.0 18.5 20.0 Scroll Scroll Scroll Scroll Power supply Capacity control steps V/ph/Hz 552 602 400/3/50 2 Refrigerant Type Charge (1) R407C Compressors Type Number Start-up…
-
Pagina 38 Technical data CLS HT 182 202 Number of circuits 2 2 Number of steps 2 2 % 50/100 50/100 kg 7.5 7.5 Scroll 2 Power supply Capacity control steps 50/100 50/100 43-57/100 9.0 11.0 12.0 Scroll Scroll Scroll Scroll V/ph/Hz 242 400/3/50 Refrigerant Type Charge (1) R407C Compressors Type Number…
-
Pagina 39 English Technical data CLS HT 402 502 Number of circuits Number of steps % 50/100 50/100 43-57/100 50/100 kg 12.0 17.0 18.5 20.0 Scroll Scroll Scroll Scroll Power supply Capacity control steps V/ph/Hz 552 602 400/3/50 2 Refrigerant Type Charge (1) R407C Compressors Type Number Start-up…
-
Pagina 40 Technical data CLC STD-LN-HPF-HT 182 202 Number of circuit 2 2 Number of steps 2 2 50/100 Power supply Capacity control steps 50/100 50/100 50/100 43-57/100 Scroll Scroll Scroll Scroll Scroll 5/8” 5/8” V/ph/Hz % 242 400/3/50 Compressors Type Number Start-up type Direct Condenser Type Coil…
-
Pagina 41 English Technical data CLC ELN 182 202 Number of circuit 2 2 Number of steps 2 2 50/100 Power supply Capacity control steps 50/100 50/100 50/100 43-57/100 Scroll Scroll Scroll Scroll Scroll 5/8” 5/8” V/ph/Hz % 242 400/3/50 Compressors Type Number Start-up type Direct Condenser Type Coil…
-
Pagina 42 Technical data CLH STD 182 202 Number of circuits 2 2 Number of steps 2 2 % 50/100 50/100 kg 7.0 11.0 Scroll 2 Power supply Capacity control steps 50/100 50/100 43-57/100 13.0 14.5 15.0 Scroll Scroll Scroll Scroll V/ph/Hz 242 400/3/50 Refrigerant Type Charge (1) R407C Compressors Type…
-
Pagina 43 English Technical data CLH STD 402 502 Number of circuits Number of steps % 50/100 50/100 43-57/100 50/100 kg 17.0 20.0 22.0 24.0 Scroll Scroll Scroll Scroll Power supply Capacity control steps V/ph/Hz 552 602 400/3/50 2 Refrigerant Type Charge (1) R407C Compressors Type Number Start-up…
-
Pagina 44 Technical data CLH LN 182 202 Number of circuits 2 2 Number of steps 2 2 % 50/100 50/100 kg 7.0 11.0 Scroll 2 Power supply Capacity control steps 50/100 50/100 43-57/100 13.0 14.5 15.0 Scroll Scroll Scroll Scroll V/ph/Hz 242 400/3/50 Refrigerant Type Charge (1) R407C Compressors Type…
-
Pagina 45 English Technical data CLH LN 402 502 Number of circuits Number of steps % 50/100 50/100 43-57/100 50/100 kg 17.0 20.0 22.0 24.0 Scroll Scroll Scroll Scroll Power supply Capacity control steps V/ph/Hz 552 602 400/3/50 2 Refrigerant Type Charge (1) R407C Compressors Type Number Start-up…
-
Pagina 46 Technical data CLH ELN 182 202 Number of circuits 2 2 Number of steps 2 2 % 50/100 50/100 kg 9.0 12.0 Scroll 2 Power supply Capacity control steps 50/100 50/100 43-57/100 15.0 15.0 15.0 Scroll Scroll Scroll Scrolll V/ph/Hz 242 400/3/50 Refrigerant Type Charge 1) R407C Compressors Type…
-
Pagina 47 English Technical data CLH ELN 402 502 Number of circuits Number of steps % 50/100 50/100 43-57/100 50/100 kg 17.0 20.0 18.5 20.0 Scroll Scroll Scroll Scroll Power supply Capacity control steps V/ph/Hz 552 602 400/3/50 2 Refrigerant Type Charge (1) R407C Compressors Type Number Start-up…
-
Pagina 48 Technical data CLH HPF 182 202 Number of circuits 2 2 Number of steps 2 2 % 50/100 50/100 kg 9.0 12.0 Scroll 2 Power supply Capacity control steps 50/100 50/100 43-57/100 15.0 15.0, 15.0 Scroll Scroll Scroll Scroll V/ph/Hz 242 400/3/50 Refrigerant Type Charge (1) R407C Compressors Type…
-
Pagina 49 English Technical data CLH HPF 402 502 Number of circuits Number of steps % 50/100 50/100 43-57/100 50/100 kg 17.0 20.0 18.5 20.0 Scroll Scroll Scroll Scroll Power supply Capacity control steps V/ph/Hz 552 602 400/3/50 2 Refrigerant Type Charge (1) R407C Compressors Type Number Start-up…
-
Pagina 50 Technical data 8.3 Unit Electrical data CLS/CLC STD Rated voltage 182 202 V(%)/ph/Hz ±10% / 3 / 50 Max. absorbed power kW 18.8 25.4 30.0 35.6 42.5 Rated current A 22.2 30.6 41.9 50.5 58.5 Max. current (FLA) A 32.1 43.3 49.9 59.9 70.3 Max. start-up current (LRA) A 116.0 149.6 175.9 205.9…
-
Pagina 51 English Technical data Unit Electrical data CLS/CLC LN-ELN Rated voltage 182 202 V(%)/ph/Hz ±10% / 3 / 50 Max. absorbed power kW 19.3 25.9 30.4 36.0 43.2 Rated current A 22.6 31.0 42.3 50.9 59.2 Max. current (FLA) A 32.5 43.7 50.3 60.3 71.0 Max. start-up current (LRA) A 116.4 150.0 176.3…
-
Pagina 52 Technical data Unit Electrical data CLS/CLC HT-HPF Rated voltage 182 202 V(%)/ph/Hz ±10% / 3 / 50 Max. absorbed power kW 19.8 26.4 31.0 36.6 44.0 Rated current A 23.7 32.1 43.4 52.0 60.8 Max. current (FLA) A 33.6 44.8 51.4 61.4 72.6 Max. start-up current (LRA) A 117.5 151.1 177.4 207.4…
-
Pagina 53 English Technical data Electrical Data Compressors and pumps Compressors CLS/CLC Number 8.5 12 13.7 13.7 Absorbed power rating, compr. 1 kW 352 Absorbed power rating, compr. 2 kW 6 8.5 12 13.7 18.6 Max. absorbed power, compr. 1 kW Max. absorbed power, compr. 2 kW Rated current, compressor…
-
Pagina 54 Technical data Fans Electrical data Fans CLS/CLC STD Power supply 182 202 V-ph-Hz ±10% / 3 / 50 Number n° Rated power per fan kW 0.48 0.48 0.48 0.48 0.48 Max. absorbed current per fan A 0.93 0.93 0.93 0.93 0.93 Fans CLS/CLC STD Power supply V-ph-Hz 400 ±10% / 3 / 50 Numero n° Rated power…
-
Pagina 55 English Technical data Unit Electrical data CLH STD Rated voltage 182 202 V(%)/ph/Hz ±10% / 3 / 50 Max. absorbed power kW 18.8 25.4 31.0 36.0 42.1 Rated current A 22.2 30.6 41.9 51.4 51.3 Max. current (FLA) A 32.1 43.3 49.9 60.8 71.6 Max. start-up current (LRA) A External fuses (A) Max.…
-
Pagina 56 Technical data Unit Electrical data CLH LN Rated voltage 182 202 V(%)/ph/Hz ±10% / 3 / 50 Max. absorbed power kW 19.3 25.9 31.4 36.7 42.8 Rated current A 22.6 31.0 42.3 52.1 52.0 Max. current (FLA) A 32.5 43.7 50.3 61.5 72.3 Max. start-up current (LRA) A External fuses (A) Max. cable…
-
Pagina 57 English Technical data Unit Electrical data CLH ELN Rated voltage 182 202 V(%)/ph/Hz ±10% / 3 / 50 Max. absorbed power kW 19.3 25.9 32.1 36.7 42.8 Rated current A 22.6 31.0 43.5 52.1 52.0 Max. current (FLA) A 32.5 43.7 51.5 61.5 72.3 Max. start-up current (LRA) A External fuses (A) Max.…
-
Pagina 58 Technical data Unit Electrical data CLH HPF Rated voltage 182 202 V(%)/ph/Hz ±10% / 3 / 50 Max. absorbed power kW 19.8 26.4 32.0 37.5 43.6 Rated current A 23.7 32.1 43.4 53.7 53.6 Max. current (FLA) A 33.6 44.8 51.4 63.1 73.9 Max. start-up current (LRA) A External fuses (A) Max. cable…
-
Pagina 59 English Technical data Electrical Data Compressors and pumps Compressorsi CLH Number 13.7 12.9 15.8 Absorbed power rating, compr. 1 kW 6 8.5 Absorbed power rating, compr. 2 kW 6 8.5 12 13.7 Max. absorbed power, compr. 1 kW Max. absorbed power, compr. 2 kW Rated current, compressor 1 A 10.1…
-
Pagina 60 Technical data Fans Electrical data Fans CLH STD Power supply 182 202 V-ph-Hz ±10% / 3 / 50 Number n° Rated power per fan kW 0.48 0.48 0.48 0.48 0.48 Max. absorbed current per fan A 0.93 0.93 0.93 0.93 0.93 Fans CLH STD Power supply V-ph-Hz 400 ±10% / 3 / 50 Number n° Rated power per fan…
-
Pagina 61 English Technical data CLH with additional resistances CLH HE Option 0 Rated voltage V(%)/ph/Hz ±10% / 3 / 50 Additional resistances kW 24 Max. absorbed power kW 43.6 50.2 64.5 69.5 75.9 99.7 107.4 Rated current A 58.9 67.3 91.9 101.4 102.4 130.3 140.5 Max. current (FLA) A 68.8 80.0 99.9…
-
Pagina 66 Technical data A3 A4 V3 A3 A4 V2 V2 V1 C1 A2 V1 C2 Compressor side Lato Compressori C1 A1 A2 C2 Lato Compressori Compressor side A1 (For the support position, see paragraph 8.5). CLH 182 STD/LN/HPF 202 STD/LN/HPF 242 STD/LN/HPF 302 STD/LN/HPF 352 STD/LN/HPF 402 STD/LN/HPF 502 STD/LN/HPF…
-
Pagina 67 A3 English Technical data A4 V3 A3 A4 V2 V2 V1 C1 A2 V1 C2 Compressor side Lato Compressori C1 A1 A2 C2 Lato Compressori Compressor side A1 (For the support position, see paragraph 8.5). CLH 182 STD/LN/HPF 202 STD/LN/HPF 242 STD/LN/HPF 302 STD/LN/HPF 352 STD/LN/HPF 402 STD/LN/HPF 502…
-
Pagina 68 Technical data A3 A4 V3 A3 A4 V2 V2 V1 C1 A2 V1 C2 Compressor side Compressori Lato C1 A1 A2 C2 Lato Compressori Compressor side A1 (For the support position, see paragraph 8.5). CLH 182 STD/LN/HPF 202 STD/LN/HPF 242 STD/LN/HPF 302 STD/LN/HPF 352 STD/LN/HPF 402 STD/LN/HPF 502 STD/LN/HPF…
-
Pagina 69 English Technical data 8.5 Overall dimensions CLS 182-302 STD-LN-ELN-HT-HPF 35 mm for transport only B A C Lifting point Lifting point Cable inlet C A 177 177 36.5 36.5 1037 1110 VIEW A 2” male 2" B (+35 mm for transport only) 784 ~470 470 ~404 1100 2” 2"male ~368 VIEW C with tank 501 VIEW…
-
Pagina 70 Technical data CLS 352-602 STD-LN-ELN-HT-HPF 35 mm for transport only B A C Lifting point Lifting point cable inlet C A 177 36.5 177 36.5 1037 1110 VIEW A 2” male 2" 784 ~470 470 ~404 1100 2" male B (+35 mm for transport only) ~368 VIEW B VIEW C with tank Models Versions Dimensions A (mm)…
-
Pagina 71 English Technical data CLC 182-602 STD-LN-ELN-HT-HPF D1 - D2 = Liquid line E1 - E2 = Suction line CLC D1-D2 E1-E2 182-202 1/2” 7/8” 242-602 5/8” 1 5/8” Note: Back view shows the refrigerant attacks. For the other dimensions to reference to CLS units. The refrigerant connections doesn’t…
-
Pagina 72 Technical data CLH 182-242 STD-LN-HPF / CLH 182-202 ELN Cable inlet C Lifting point Lifting point 35 mm for transport only 177 A 177 36.5 1037 36.5 1110 VIEW A 2” male 2" 1100 2" male B (+35 mm for transport only) 368 VIEW C with tank VIEW B Models CLH 182 CLH 202 CLH 242 Versions…
-
Pagina 73 English Technical data CLH 302 STD-LN-ELN-HPF / CLH 242 ELN / CLH 352-602 STD-LN-ELN-HPF Lifting point Lifting point Cable inlet 35 mm for transport only A 177 36.5 177 36.5 1037 1110 VIEW A 2” male 2" 1100 2 " male B (+35 mm for transport only) 368 VIEW B VIEW C with tank Models Versions…
-
Pagina 75 MAINTENANCE Planned maintenance Do not throw away the waste oil of the compressor, because it contains refrigerant in solution. The waste oil must be returned to the manufacturer. Unless otherwise specified, the operations described below may be carried out only by a trained maintenance…
-
Pagina 76 Maintenance 9.3 Refrigerant charge Do not inject refrigerant liquid into the LP side of the circuit. Be very careful, and charge the circuit properly. If the charge is insufficient, the efficiency of the unit will be lower than expected. In the worst of cases the LP pressure switch may be…
-
Pagina 77 9.7 Dehydrating filter The refrigeration circuits are provided with dehydrating filters. The filter clogging is marked by the presence of air bubbles in the sight glass, or by the difference between the temperatures measured downstream from and upstream of the drying filter. If, once the…
-
Pagina 78 Troubleshooting 10 TROUBLESHOOTING The table below lists the anomalies of operation of the unit, the relevant causes and the corrective measures. For anomalies of any other type or not listed, contact one of Itelco-Clima’s Service Centre for technical assistance. Anomaly Cause Operation…
-
Pagina 79 Anomaly Cause Operation One or both compressors are not working. Breaking of the electric circuit. Check the electric circuit and detect any ground dispersions and short circuits. Check fuses. Intervention of the HP pressure switch. Reset the pressure switch and the control panel and…
-
Pagina 80 Spare parts 11 SPARE PARTS 11.1 Spare part list The table below shows the list of spare parts recommended during the first two years of operation. Component HP pressure switch LP pressure switch Gas filter Thermostatic valve Auxiliary relays Fan’s fuses Compressor’s fuses Auxiliary fuses…
-
Pagina 81 12 DISMANTLING, DEMOLITION AND SCRAPPING During the draining of the refrigeration circuits, do not let the refrigerant overflow in the surrounding atmosphere. The circuit must be drained using suitable recovery equipment. Do not disperse the waste oil of the compressors in the environment…
-