Кондиционеры Sanyo серии SPW. Полный сервис-мануал продукции
Кондиционеры Sanyo серии SPW-CR363GVH8, SPW-CR483GVH8, SPW-CR703GVH8, SPW-CR903GVH8, SPW-CR363GV8, SPW-CR483GV8, SPW-CR703GV8, SPW-CR903GV8, SPW-XR123GH56, SPW-XR183GH56, SPW-XR253GH56, SPW-XR363GH56, SPW-XR483GH56, SPW-SR93GH56, SPW-SR123GH56, SPW-SR183GH56, SPW-SR253GH56, SPW-ASR93GH56, SPW-ASR123GH56, SPW-ASR93GH56, SPW-KR93GH56, SPW-KR123GH56, SPW-KR183GH56, SPW-KR93GH56, SPW-TR183GH56, SPW-TR253GH56, SPW-TR363GH56, SPW-TR483GH56, SPW-UR93GH56, SPW-UR123GH56, SPW-UR183GH56, SPW-UR253GH56, SPW-UR363GH56, SPW-UR483GH56, SPW-UR93GH56, SPW-DR253GH56, SPW-DR363GH56, SPW-DR483GH56, SPW-FR93GH56, SPW-FR123GH56, SPW-FR183GH56, SPW-FR253GH56, SPW-FMR93GH56, SPW-FMR123GH56, SPW-FMR183GH56, SPW-FMR253GH56, SPW-SLR93GH56, SPW-SLR123GH56, SPW-SLR183GH56, SPW-SLR253GH56. Полный сервис-мануал продукции.
Загружаем документ…
Текст каталога
-
SERVICE MANUAL
-
Important
Please Read Before Starting When Installing This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently. …In a Room Properly insulate any…
-
Check of Density Limit
Important The room in which the air conditioner is to be installed requires a design that in the event of refrigerant gas leaking out, its density will not exceed a set limit. NOTE (1) The refrigerant R-407C which is used in the air conditioner is safe, without the toxicity or combustibility of…
-
Page
Please Read Before Starting Important i Check of Limit Density Important ii Line Up iv Section 1 : ECO MULTI SYSTEM Unit Specifications I - 1 1. Outdoor Unit I - 3 2. 4-way Air Discharge Semi-concealed Type I - 19 3. 2-way Air Discharge Semi-concealed Type I - 34 4. 1-way Air Discharge…
-
ECO MULTI SYSTEM
-
1. ECO MULTI SYSTEM Unit Specifications
1. Outdoor Unit I - 3 1-1. Specifications I - 3 1-2. Major component specifications I - 9 1-3. Control specifications I - 12 1-4. Other component specifications I - 13 1-5. Dimensional data I - 15 1-6. Refrigerant flow diagram I - 16 1-7. Noise criterion curves I - 18 2. 4-way Air Discharge…
-
9. Floor Standing Type (F Type) .......................................................I - 107
9-1. Specifications I - 107 9-2. Major component specifications I - 111 9-3. Other component specifications I - 115 9-4. Dimensional data I - 116 9-5. Noise criterion curves I - 117 9-6. Air throw distance chart I - 118 10. Concealed Floor Standing Type (FM Type) I - 119 1 10-1. Specifications I…
-
1-1. Specifications
Unit specifications (A) MODEL No. Outdoor Unit SPW – CR363GVH8 POWER SOURCE 380 - 400 - 415 V / 3 N / 50Hz PERFORMANCE Capacity kW BTU / h Cooling Heating 11.2 38,200 12.5 42,700 m3/min(cu. ft/min) Air circulation (Hi) 1 84 (2,970) ELECTRICAL RATINGS Voltage rating V Available voltage range V…
-
Unit specifications (B)
MODEL No. 1 Outdoor Unit SPW – CR363GV8 POWER SOURCE 380 - 400 - 415 V / 3 N / 50Hz PERFORMANCE Cooling Capacity kW BTU / h 11.2 38,200 m3/min(cu. ft/min) Air circulation (Hi) 84 (2,970) ELECTRICAL RATINGS Voltage rating V Available voltage range V Running amperes A 7.9 7.9 7.9 Max. running amperes*…
-
Unit specifications (C)
MODEL No. Outdoor Unit SPW – CR483GVH8 POWER SOURCE 380 - 400 - 415 V / 3 N / 50Hz PERFORMANCE Capacity kW BTU / h Cooling Heating 14 47,800 16 54,600 m3/min(cu. ft/min) Air circulation (Hi) 1 84 (2,970) ELECTRICAL RATINGS Voltage rating V Available voltage range V Running amperes A 9.5 9.5 9.4 Max.…
-
Unit specifications (D)
MODEL No. 1 Outdoor Unit SPW – CR483GV8 POWER SOURCE 380 - 400 - 415 V / 3 N / 50Hz PERFORMANCE Cooling Capacity kW BTU / h 14 47,800 m3/min(cu. ft/min) Air circulation (Hi) 84 (2,790) ELECTRICAL RATINGS Voltage rating V Available voltage range V Running amperes A 9.5 9.5 9.4 Max. running amperes* A…
-
Unit specifications (E)
MODEL No. Outdoor Unit SPW – CR703GVH8 POWER SOURCE 380 - 400 - 415 V / 3 phase / 50Hz PERFORMANCE Cooling Heating 22.4 76,400 25.0 85,300 Capacity kW BTU / h m3/min(cu. ft/min) Air circulation (Hi) 1 155 (5,470) ELECTRICAL RATINGS Voltage rating V 380 - 400 - 415 Available voltage range V Running…
-
Unit specifications (F)
MODEL No. 1 Outdoor Unit SPW – CR703GV8 POWER SOURCE 380 - 400 - 415 V / 3 phase / 50Hz PERFORMANCE Cooling Capacity kW BTU / h 22.4 76,400 m3/min(cu. ft/min) Air circulation (Hi) 155 (5,470) ELECTRICAL RATINGS Voltage rating V 380 - 400 - 415 Available voltage range V 342 - 456 Running amperes A…
-
Unit specifications (G)
MODEL No. Outdoor Unit SPW – CR903GVH8 POWER SOURCE 380 - 400 - 415 V / 3 phase / 50Hz PERFORMANCE Cooling Capacity kW BTU / h Heating 28.0 95,500 m3/min(cu. ft/min) Air circulation (Hi) 1 31.5 107,500 150 (5,300) ELECTRICAL RATINGS Voltage rating V 380 - 400 - 415 Available voltage range V 342…
-
Unit specifications (H)
MODEL No. 1 Outdoor Unit SPW – CR903GV8 POWER SOURCE 380 - 400 - 415 V / 3 phase / 50Hz PERFORMANCE Cooling Capacity kW BTU / h 28.0 95,500 m3/min(cu. ft/min) Air circulation (Hi) 150 (5,300) ELECTRICAL RATINGS Voltage rating V 380 - 400 - 415 Available voltage range V 342 – 456 Running amperes A…
-
1-2. Major component specifications
Outdoor Unit (A) MODEL No. SPW – CR363GVH8 / SPW – CR363GV8 Source 380 - 400 - 415 V / 3 phase / 50Hz Controller P.C.B. Ass’y CR - CR363GVH / CR - CR363GV Control circuit fuse 250 V , 3.15 A Compressor 1 Rotary (Hermetic) PC (Power Control) Model … Code No. C-5RN373H8R 80838788 Nominal output kW…
-
Outdoor Unit (B)
1 MODEL No. SPW – CR483GVH8 / SPW – CR483GV8 Source 380 - 400 - 415 V / 3 phase / 50Hz Controller P.C.B. Ass’y CR - CR363GVH / CR - CR363GV Control circuit fuse 250 V , 3.15 A Compressor Rotary (Hermetic) PC (Power Control) Model … Code No. C-5RN433H8R 80844788 Nominal output kW 4.3 Compressor oil…
-
Outdoor Unit (C)
-
Outdoor Unit (D)
-
1-3. Control specifications
MODEL No. Thermostat SPW – CR363GVH8 / SPW – CR363GV8 SPW – CR483GVH8 / SPW – CR483GV8 SPW – CR703GVH8 / SPW – CR703GV8 SPW – CR903GVH8 / SPW – CR903GV8 Outdoor Unit Available Setting temp. Cooling 18 – 30 °C Dry 18 – 30 °C Heating 16 – 26 °C Operation mode Mode setting HEAT* • DRY • COOL • FAN Fan…
-
1-4. Other component specifications
-
MODEL No
-
1-5. Dimentional data
Diagram of ECO MULTI Outer Dimensions 1235 4 5 1239_C_I Detail of installation hole 1098 1218 4 Installation hole ø15 224 3 Installation hole (4 - ø15 hole) Refrigerant liquid line ø12.7 (narrow tube) flare connection Refrigerant gas line (wide tube) 90 type: ø28.58 70 type: ø25.4 Brazing connection…
-
1-6. Refrigerant flow diagram
-
SPW-CR703GVH8, CR903GVH8 (Heat pump only)
High pressure port Discharge A.C gas sensor compressor TH2 SAVE valve S CM 1 HP High pressure switch Accumulator Discharge P.C gas sensor compressor TH1 Oil CM separator HP High pressure switch Low pressure port S S S S HPV valve LPV 1 valve LPV 2 valve Wide tube (Type 70 : ø25.4) (Type 90 : ø28.58)…
-
1-7. Noise criterion curves
-
2-1. Specifications
Unit specifications (A) MODEL No. 1 Indoor Unit SPW-XR123GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase – 50Hz PERFORMANCE Cooling Heating 3.6 12,000 4.2 14,000 Capacity kW BTU / h Air circulation (Hi / Me / Lo) m3/h Moisture removal (High) Liters/h 900 / 780 / 660 0.9 — ELECTRICAL RATINGS Voltage…
-
Unit specifications (B)
MODEL No. Indoor Unit SPW-XR183GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating 5.6 19,000 6.3 21,000 Capacity kW BTU / h 3 Air circulation (Hi / Me / Lo) m /h Moisture removal (High) Liters/h 1 900 / 780 / 660 2.6 — ELECTRICAL RATINGS Voltage rating V 220 - 230 - 240…
-
Unit specifications (C)
MODEL No. 1 Indoor Unit SPW-XR253GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating 7.3 25,000 8.0 27,000 Capacity kW BTU / h Air circulation (Hi / Me / Lo) m3/h Moisture removal (High) Liters/h 1,140 / 1,020 / 840 3.6 — ELECTRICAL RATINGS Voltage rating V 220 - 230…
-
Unit specifications (D)
MODEL No. Indoor Unit SPW-XR363GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating 10.6 36,000 11.4 39,000 Capacity kW BTU / h 3 Air circulation (Hi / Me / Lo) m /h Moisture removal (High) Liters/h 1 1,920 / 1,680 / 1,320 4.6 — ELECTRICAL RATINGS Voltage rating V 220…
-
Unit specifications (E)
MODEL No. 1 Indoor Unit SPW-XR483GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating 14.0 47,800 16.0 54,600 Capacity kW BTU / h Air circulation (Hi / Me / Lo) m3/h Moisture removal (High) Liters/h 1,920 / 1,680 / 1,320 7.4 — ELECTRICAL RATINGS Voltage rating V 220 - 230…
-
2-2. Major component specifications
Indoor unit (A) MODEL No. SPW-XR123GH56 Source 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y Fan (Number…diameter) CR-X253GH (Microprocessor) mm Turbo (1 … ø 490) W SFG6X-41A5P … 40 W 1 Fan motor Model…Nominal output Source No. of pole…r.p.m. (230 V, High) Coil resistance (Ambient…
-
Indoor unit (B)
MODEL No. SPW-XR183GH56 Source 1 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y Fan (Number…diameter) CR-X253GH (Microprocessor) mm Turbo (1 … ø 490) W SFG6X-41A5P … 40 W Fan motor Model…Nominal output Source No. of pole…r.p.m. (230 V, High) Coil resistance (Ambient temperature 20°C) 220…
-
Indoor unit (C)
MODEL No. SPW-XR253GH56 Source 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y Fan (Number…diameter) CR-X253GH (Microprocessor) mm Turbo (1 … ø 490) W SFG6X-41A5P … 40 W 1 Fan motor Model…Nominal output Source No. of pole…r.p.m. (230 V, High) Coil resistance (Ambient temperature 20°C) 220…
-
Indoor unit (D)
MODEL No. SPW-XR363GH56 Source 1 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y Fan (Number…diameter) CR-X253GH (Microprocessor) mm Turbo (1 … ø 490) W SFG6X-61A3P…60 W Fan motor Model…Nominal output Source No. of pole…r.p.m. (230 V, High) Coil resistance (Ambient temperature 20°C) 220…
-
Indoor unit (E)
MODEL No. SPW-XR483GH56 Source 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y Fan (Number…diameter) CR-X253GH (Microprocessor) mm Turbo (1 … ø 490) W SFG6X-61A3P…60 W 1 Fan motor Model…Nominal output Source No. of pole…r.p.m. (230 V, High) Coil resistance (Ambient temperature 20°C) 220…
-
2-3. Other component specifications
-
2-4. Dimensional data
Indoor unit : 12, 18, 25 Type X-view (Ceiling opening) 590 (Suspention bolt pitch) (Suspention bolt pitch) 820 (Ceiling opening) 9 Panel center Air intake grille Air outlet Refrigerant liquid line [ø 9.52 (In case of 25 type, use the tube connector.)] Refrigerant gas line ø 12.7: 12 type, ø 15.88…
-
Indoor unit : 36, 48 Type
X-view (Ceiling opening) (Suspention bolt pitch) 15 1150 790 12 1050 Panel center 1020 (Suspention bolt pitch) 1110 (Ceiling opening) Air intake grille Air outlet Refrigerant liquid line (ø9.52) Refrigerant gas line (ø19.05) Drain connection Power supply entry For discharge duct Humidifier (option)…
-
2-5. Noise criterion curves
MODEL : SPW-XR123GH56 , XR183GH56 MODEL : SPW-XR253GH56 SOUND LEVEL : HIGH 37 dB(A), NC 30 SOUND LEVEL : HIGH 37 dB(A), NC 30 LOW 30 dB(A), NC 22 LOW CONDITION : Center, Under the unit 1.5 m SOURCE : 220 - 230 - 240 V, 1 Phase, 50 Hz NC 22 CONDITION : Center, Under the unit 1.5 m SOURCE : 220 - 230…
-
2-6. Air throw distance chart
Model: 12, 18, 25 Type HORIZONTAL DISTANCE (m) AXIS AIR VELOCITY (m/s) VERTICAL DISTANCE (m) 0 AXIS AIR VELOCITY 0276_X_I Model: 36, 48 Type HORIZONTAL DISTANCE (m) AXIS AIR VELOCITY (m/s) VERTICAL DISTANCE (m) 1 1 AXIS AIR VELOCITY 0277_X_I : LOUVER ANGLE 20˚ in Cooling mode : LOUVER ANGLE 60˚ in…
-
3-1. Specifications
Unit specifications (A) MODEL No. Indoor Unit SPW-SR93GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating 2.8 9,600 3.2 11,000 Capacity kW BTU / h 3 Air circulation (Hi / Me / Lo) m /h Moisture removal (High) Liters/h 1 540 / 485 / 410 1.0 — ELECTRICAL RATINGS Voltage…
-
Unit specifications (B)
MODEL No. 1 Indoor Unit SPW-SR123GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating 3.6 12,000 4.2 14,000 Capacity kW BTU / h Air circulation (Hi / Me / Lo) m3/h Moisture removal (High) Liters/h 570 / 510 / 430 1.6 — ELECTRICAL RATINGS Voltage rating V 220 - 230 - 240…
-
Unit specifications (C)
MODEL No. Indoor Unit SPW-SR183GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating 5.6 19,000 6.3 21,000 Capacity kW BTU / h 3 Air circulation (Hi / Me / Lo) m /h Moisture removal (High) Liters/h 1 960 / 860 / 720 2.4 — ELECTRICAL RATINGS Voltage rating V 220 / 230 / 240…
-
Unit specifications (D)
MODEL No. 1 Indoor Unit SPW-SR253GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating 7.3 25,000 8.0 27,000 Capacity kW BTU / h Air circulation (Hi / Me / Lo) m3/h Moisture removal (High) Liters/h 1,140 / 1,030 / 860 3.5 — ELECTRICAL RATINGS Voltage rating V 220 - 230…
-
3-2. Major component specifications
Indoor unit (A) MODEL No. SPW-SR93GH56 Source 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) mm Centrifugal (1 … ø 190) W UF4X-31B3P 30 W 1 Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of pole…r.p.m. (230…
-
Indoor unit (B)
MODEL No. SPW-SR123GH56 Source 1 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y Fan (Number…diameter) CR-X253GH (Microprocessor) mm Centrifugal (1…ø 190) W UF4X-31B3P 30 W Fan motor Model…Nominal output Source No. of pole…r.p.m. (230 V, High) Coil resistance (Ambient temperature 20 °C)…
-
Indoor unit (C)
MODEL No. SPW-SR183GH56 Source 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) mm Centrifugal (2 ø190) W KFG4X-51E3P 50 W 1 Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of pole…r.p.m. (230 V, High) rpm. Ω…
-
Indoor unit (D)
MODEL No. SPW-SR253GH56 Source 1 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y Fan (Number…diameter) CR-X253GH (Microprocessor) mm Centrifugal (2 … ø 190) W KFG4X-51E3P 50 W Fan motor Model…Nominal output Source No. of pole…r.p.m. (230 V, High) Coil resistance (Ambient temperature 20…
-
3-3. Other component specifications
-
3-4. Dimensional data
Indoor unit : 9, 12 Type FOR FRESH AIR INTAKE (ø125 HOLE) 140 1110 1110 1070 PANEL CENTER 510 330 FOR DISCHARGE DUCT (1–ø150 SLIT HOLE) 616 INSPECTION PANEL FOR DRAIN PUMP 640 SUSPENSION HOLES 680 CEILING OPENING (1070 × 640) INSPECTION PANEL FOR ECV, DRAIN PAN Refrigerant liquid line (ø 9.52)…
-
Indoor unit : 18, 25 Type
1 680 1390 INSPECTION PANEL FOR DRAIN PUMP 1390 1350 32 590 1176 PANEL CENTER 650 330 FOR DISCHARGE DUCT (2–ø150 SLIT HOLES) 616 CEILING OPENING (1350 × 640) 640 SUSPENSION HOLES 680 FOR FRESH AIR INTAKE (ø125 HOLE) Refrigerant gas line (ø 15.88) Drain connection (25 A. O.D.32 mm) Power supply entry…
-
3-5. Noise criterion curves
MODEL MODEL SOUND LEVEL : HIGH 32 dB(A), NC 29 LOW 25 dB(A), NC 21 CONDITION : Center, SOURCE : 220 - 230 - 240 V, LOW Under the unit 1.5 m 1 Phase, 50 Hz SOURCE : 220 - 230 - 240 V, 1 Phase, 80 80 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 APPROXIMATE THRESHOLD OF 20 NC-20 HEARING FOR CONTINUOUS…
-
MODEL
: SPW-SR183GH56 MODEL SOUND LEVEL : HIGH 34 dB(A), NC 29 LOW 27 dB(A), NC 24 : Center, SOURCE : 220 - 230 - 240 V, SOUND LEVEL : HIGH 37 dB(A), LOW Under the unit 1.5 m 1 Phase, 50 Hz SOURCE : 220 - 230 - 240 V, 1 Phase, NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 APPROXIMATE THRESHOLD OF 20 NC-20…
-
3-6. Air throw distance chart
Model: 9, 12 Type HORIZONTAL DISTANCE (m) AXIS AIR VELOCITY 0282_S_I Model: 18 Type HORIZONTAL DISTANCE (m) AXIS AIR VELOCITY (m/s) VERTICAL DISTANCE (m) 0 6 AXIS AIR VELOCITY 0283_S_I Model: 25 Type HORIZONTAL DISTANCE (m) AXIS AIR VELOCITY AXIS AIR VELOCITY (m/s) VERTICAL DISTANCE (m) 1 AXIS AIR…
-
4-1. Specifications
Unit specifications (A) MODEL No. Indoor Unit SPW-ASR93GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Capacity kW BTU / h Heating 2.8 9,600 3 Air circulation (Hi / Me / Lo) m /h Moisture removal (High) Liters / h 1 3.2 11,000 480 / 420 / 360 1.1 — ELECTRICAL RATINGS Voltage…
-
Unit specifications (B)
MODEL No. 1 Indoor Unit SPW-ASR123GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Capacity kW BTU / h Air circulation (Hi / Me / Lo) m3 / h Moisture removal (High) Liters / h Heating 3.6 12,000 4.2 14,000 580 / 520 / 450 1.7 — ELECTRICAL RATINGS Voltage rating V 220 - 230…
-
4-2. Major component specifications
Indoor unit (A) MODEL No. SPW-ASR93GH56 Source 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) mm Centrifugal (1 … ø 190) W UE6Q-21B3P … 20 W 1 Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of pole…r.p.m.…
-
Indoor unit (B)
MODEL No. SPW-ASR123GH56 Source 1 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) mm Centrifugal (1 … ø 190) W UE6Q-21B3P … 20 W Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of pole…r.p.m. (230 V, High) rpm.…
-
4-3. Other component specifications
-
4-4. Dimensional data
Indoor unit : 9, 12 Type 65 15 Z * : Suspension bolt pitch : For ceiling opening 590** 620 4 - 12 × 652* Z View 780** 60 287 483* 70 20 Refrigerant liquid line (ø 9.52) Refrigerant gas line (ø 12.7) Drain connection (25 A, O.D.32 mm) Power supply entry Suspension holes (4-15 × 30) For discharge duct…
-
4-5. Noise criterion curves
MODEL : SPW-ASR93GH56 MODEL SOUND LEVEL : HIGH 34 dB(A), NC 25 LOW 30 dB(A), NC 22 CONDITION : Center, SOURCE : 220 - 230 - 240 V, SOUND LEVEL : HIGH 38 dB(A), LOW Under the unit 1.5 m 1 Phase, 50 Hz 31 dB(A), NC 32 NC 25 CONDITION : Center, SOURCE : 220 - 230 - 240 V, 1 Phase, Under the unit 1.5 m…
-
4-6. Air throw distance chart
Model: 9 Type HORIZONTAL DISTANCE (m) AXIS AIR VELOCITY 0287_AS_I Model: 12 Type HORIZONTAL DISTANCE (m) AXIS AIR VELOCITY (m/s) VERTICAL DISTANCE (m) 1 AXIS AIR VELOCITY (m/s) VERTICAL DISTANCE (m) AXIS AIR VELOCITY 0288_AS_I 1: LOUVER ANGLE 10˚ in cooling mode 2: LOUVER ANGLE 20˚ in cooling mode…
-
5-1. Specifications
Unit specifications (A) MODEL No. Indoor Unit SPW-KR93GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Capacity kW BTU / h Heating 2.8 9,600 3 Air circulation (Hi / Me / Lo) m /h Moisture removal (High) Liters / h 1 3.2 11,000 450 / 390 / 340 1.3 — ELECTRICAL RATINGS Voltage…
-
Unit specifications (B)
MODEL No. 1 Indoor Unit SPW-KR123GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Capacity kW BTU / h Heating 3.6 12,000 4.2 14,000 m3 / h Air circulation (Hi / Me / Lo) Moisture removal (High) 630 / 490 / 430 Liters / h 1.6 — ELECTRICAL RATINGS Voltage rating V 220 - 230…
-
Unit specifications (C)
MODEL No. Indoor Unit SPW-KR183GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating 5.0 17,000 6.0 20,000 Capacity kW BTU / h 3 Air circulation (Hi / Me / Lo) m /h Moisture removal (High) Liters / h 1 800 / 660 / 520 2.5 — ELECTRICAL RATINGS Voltage rating V 220 - 230…
-
5-2. Major component specifications
-
Indoor unit (B)
-
Indoor unit (C)
-
5-3. Other component specifications
-
5-4. Dimensional data
Indoor unit : 9, 12, 18 Type A VIEW A 1000 0289_K_I TYPE OF COPPER TUBE TUBE OUTER DIAMETER NARROW 9.52 mm (3 / 8 inch) 9, 12, 18 type WIDE NOTES 12.7 mm (1 / 2 inch) 9, 12 type 15.88 mm (5 / 8 inch) 18 type I - 66 SM830063
-
5-5. Noise criterion curves
MODEL : SPW-KR93GH56 MODEL SOUND LEVEL : HIGH 38 dB(A), NC 33 LOW 30 dB(A), NC 25 SOUND LEVEL : HIGH 40 dB(A), LOW : Distance 1 m, SOURCE : 220 - 230 - 240 V, 1 Phase, 50 Hz Under the unit 1 m SOURCE : 220 - 230 - 240 V, 1 Phase, 50 Hz NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 10 NC-20 THRESHOLD OF…
-
5-6. Air throw distance chart
Model: 9 Type HORIZONTAL DISTANCE (m) AXIS AIR VELOCITY 0293_K_I Model: 12 Type HORIZONTAL DISTANCE (m) AXIS AIR VELOCITY (m/s) VERTICAL DISTANCE (m) 0294_K_I Model: 18 Type HORIZONTAL DISTANCE (m) AXIS AIR VELOCITY (m/s) VERTICAL DISTANCE (m) 1 AXIS AIR VELOCITY (m/s) VERTICAL DISTANCE (m) 0295_K_I…
-
6-1. Specifications
Unit specifications (A) MODEL No. Indoor Unit SPW-TR183GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating 5.6 19,000 6.3 21,000 Capacity kW BTU / h 3 Air circulation (Hi / Me / Lo) m /h Moisture removal (High) Liters / h 1 780 / 660 / 540 2.8 — ELECTRICAL RATINGS…
-
Unit specifications (B)
MODEL No. 1 Indoor Unit SPW-TR253GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Capacity kW BTU / h 7.3 25,000 m3 / h Air circulation (Hi / Me / Lo) Moisture removal (High) Heating 8.0 27,000 1,080 / 960 / 840 Liters / h 3.5 — ELECTRICAL RATINGS Voltage rating V 220 - 230…
-
Unit specifications (C)
MODEL No. Indoor Unit SPW-TR363GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating 10.6 36,000 11.4 39,000 Capacity kW BTU / h Air circulation (Hi / Me / Lo) m3 / h Moisture removal (High) Liters / h 1 1,680 / 1,410 / 1,200 4.7 — ELECTRICAL RATINGS Voltage rating V 220…
-
Unit specifications (D)
MODEL No. 1 Indoor Unit SPW-TR483GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Capacity kW BTU / h 14.0 47,800 m3 / h Air circulation (Hi / Me / Lo) Moisture removal (High) Heating 16.0 54,600 1,920 / 1,680 / 1,320 Liters / h 7.0 — ELECTRICAL RATINGS Voltage rating V 220…
-
6-2. Major component specifications
Indoor unit (A) MODEL No. SPW-TR183GH56 Source 220 - 230 - 240 V / 1 phase / 50 Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) mm Centrifugal (3 … ø 130) W SR4X-31A3P … 30 W 1 Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of pole…r.p.m.…
-
Indoor unit (B)
MODEL No. SPW-TR253GH56 Source 1 220 - 230 - 240 V / 1 phase / 50 Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) mm Centrifugal (4 … ø 130) W SR4X-51A6P … 50 W Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of pole…r.p.m. (230 V, High) rpm.…
-
Indoor unit (C)
MODEL No. SPW-TR363GH56 Source 220 - 230 - 240 V / 1 phase / 50 Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) mm Centrifugal (4 … ø 150) W KFG4X-101C6P…100 W 1 Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of pole…r.p.m. (230 V, High)…
-
Indoor unit (D)
MODEL No. SPW-TR483GH56 Source 1 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y Fan (Number…diameter) CR-X253GH (Microprocessor) mm Centrifugal (4…ø150) W KFG4X-101C6P…100 W Fan motor Model…Nominal output Source No. of pole…r.p.m. (230 V, High) Coil resistance (Ambient temperature 20°C)…
-
6-3. Other component specifications
-
6-4. Dimensional data
Indoor unit : 18, 25, 36, 48 Type I Hole for wall-through piping (View from front) C (Suspension bolt hole pitch) 35 500 or more 251 Air intake 250 Air outlet or more (Service space) A 250 or more Front (Service space) 89 N 670 L B M (Suspension bolt hole pitch) 141 J Holes in the rear unit (View…
-
6-5. Noise criterion curves
-
6-6. Air throw distance chart
Model: 18 Type HORIZONTAL DISTANCE (m) 1 2 AXIS AIR VELOCITY (m/s) VERTICAL DISTANCE (m) AXIS AIR VELOCITY 1224_T_I HORIZONTAL DISTANCE (m) AXIS AIR VELOCITY 1225_T_I Model: 36 Type HORIZONTAL DISTANCE (m) 0 AXIS AIR VELOCITY (m/s) VERTICAL DISTANCE (m) 3 0 Model: 25 Type AXIS AIR VELOCITY 1226_T_I…
-
7-1. Specifications
Unit specifications (A) MODEL No. Indoor Unit SPW-UR93GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating kW 2.8 3.2 BTU / h 9,600 11,000 Capacity Air circulation (Hi / Me / Lo) m3 / h Moisture removal (High) Liters / h 1 480 / 440 / 330 1.3 External static pressure…
-
Unit specifications (B)
MODEL No. 1 Indoor Unit SPW-UR123GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Capacity kW BTU / h Heating 3.6 12,000 4.2 14,000 m3 / h Air circulation (Hi / Me / Lo) External static pressure (High) 600 / 490 / 400 mmAq (Pa) Moisture removal (High) 5 (49): at shipment, 10…
-
Unit specifications (C)
MODEL No. Indoor Unit SPW-UR183GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating 5.6 19,000 6.3 21,000 Capacity kW BTU / h 3 Air circulation (Hi / Me / Lo) m /h External static pressure (High) 840 / 680 / 540 mmAq (Pa) Moisture removal (High) 1 5 (49): at shipment, 10…
-
Unit specifications (D)
MODEL No. 1 Indoor Unit SPW-UR253GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Capacity kW BTU / h 7.3 25,000 m3 / h Air circulation (Hi / Me / Lo) External static pressure (High) 8.0 27,000 1,260 / 1,080 / 780 mmAq (Pa) Moisture removal (High) Heating 5 (49): at shipment…
-
Unit specifications (E)
MODEL No. Indoor Unit SPW-UR363GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating 10.6 36,000 11.4 39,000 Capacity kW BTU / h 3 Air circulation (Hi / Me / Lo) m /h External static pressure (High) mmAq (Pa) Moisture removal (High) 1 1,920 / 1,440 / 1,200 7 (69): at…
-
Unit specifications (F)
MODEL No. 1 Indoor Unit SPW-UR483GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Capacity kW BTU / h 14.0 47,800 m3 / h Air circulation (Hi / Me / Lo) External static pressure (High) mmAq (Pa) Moisture removal (High) Heating 16.0 54,600 1,920 / 1,440 / 1,200 7 (69): at…
-
7-2. Major component specifications
Indoor unit (A) MODEL No. SPW-UR93GH56 Source 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) mm Centrifugal (1 … ø 190) W KFG4X-31A3P … 30 W 1 Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of pole…r.p.m.…
-
Indoor unit (B)
MODEL No. SPW-UR123GH56 Source 1 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y Fan (Number…diameter) CR-X253GH (Microprocessor) mm Centrifugal (1 … ø 190) W KFG4X-71A5P … 70 W Fan motor Model…Nominal output Source No. of pole…r.p.m. (230 V, High) Coil resistance (Ambient temperature…
-
Indoor unit (C)
MODEL No. SPW-UR183GH56 Source 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) mm Centrifugal (1 … ø 190) W KFG4X-101B5P … 100 W 1 Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of pole…r.p.m. (230 V, High)…
-
Indoor unit (D)
MODEL No. SPW-UR253GH56 Source 1 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y Fan (Number…diameter) CR-X253GH (Microprocessor) mm Centrifugal (2 … ø 190) W KFC4X-101B5P … 100 W Fan motor Model…Nominal output Source No. of pole…r.p.m. (230 V, High) Coil resistance (Ambient temperature…
-
Indoor unit (E)
MODEL No. SPW-UR363GH56 Source 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) 1 mm Centrifugal (3 … ø 190) W KFG4X-101B5PA…100 W / KFC4X-161B5P…160 W Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of…
-
Indoor unit (F)
MODEL No. SPW-UR483GH56 Source 1 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) mm Centrifugal (3 … ø 190) W KFG4X-101B5PA … 100 W / KFC4X-161B5P … 160 W Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of…
-
7-3. Other component specifications
-
7-4. Dimensional data
2-ø3.3 (Hole) Indoor unit : 9, 12, 18 Type (Suspension bolt pitch) up 4-ø3.1 (Hole) 25 35 8-ø3.1 (Hole) 5–ø3.3 (Hole ) (Suspension bolt pitch) (O.D) 256 (O.D) 665 Refrigerant liquid line (ø 9.52) Refrigerant gas line (9,12: ø 12.7, 18: ø 15.88) Drain connection (25 A, O.D.32 mm) Electrical junction…
-
2-ø3.3 (Hole) Indoor unit: 25 Type (Suspension bolt pitch) 1130 (Suspension bolt pitch) 1050 290 120 10-ø3.1 (Hole) up 9 4-ø3.1 (Hole) 175 Refrigerant liquid line (Narrow tube – ø 9.52) (In case of 25 type, use the tube connector) Refrigerant gas line (Wide tube – ø 15.88) Drain connection (25 A…
-
2-ø3.3 (Hole) Indoor unit: 36, 48 Type 117 Refrigerant liquid line (Narrow tube – ø 9.52) Refrigerant gas line (Wide tube – ø19.05) Drain connection (25 A OD.32 mm) Electrical junction box Power supply entry Mounting for suspension Duct connection for discharge (ø200) Duct connection for suction 9…
-
7-5. Noise criterion curves
-
MODEL
: SPW-UR363GH56, UR483GH56 SOUND LEVEL : HIGH 42 dB(A), NC 37 / LOW 30 dB(A), NC 23 (HIGH 46 dB(A), NC 41 / LOW 38 dB(A), NC 32) ( CONDITION : Under the unit 1.5 m SOURCE : 220 - 230 - 240 V, 1 Phase, 50 Hz 90 80 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar) 1 ) : when Booster cable…
-
7-6. Increasing the Fan Speed
Electrical component box If external static pressure is too great (due to long extension of ducts, for example), the air flow volume may drop too low at each air outlet. This problem may be solved by increasing the fan speed using the following procedure: Booster cable Fan motor socket (At shipment)…
-
8-1. Specification
Unit specifications (A) MODEL No. 1 Indoor Unit SPW-DR253GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Capacity kW BTU / h 7.3 25,000 m3 / h Air circulation (Hi / Me / Lo) External static pressure (High) Heating 8.0 27,000 1,380 / 1,320 / 1,260 mmAq (Pa) Moisture removal…
-
Unit specifications (B)
MODEL No. Indoor Unit SPW-DR363GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Capacity kW BTU / h 10.6 36,000 3 Air circulation (Hi / Me / Lo) m /h External static pressure (High) Heating 1,800 / 1,680 / 1,500 mmAq (Pa) Moisture removal (High) 1 11.4 39,000 18 (176) Liters…
-
Unit specifications (C)
MODEL No. 1 Indoor Unit SPW-DR483GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Capacity kW BTU / h 14.0 47,800 m3 / h Air circulation (Hi / Me / Lo) External static pressure (High) Heating 16.0 54,600 2,160 / 2,100 / 1,980 mmAq (Pa) Moisture removal (High) 17 (167) Liters…
-
8-2. Major component specifications
Indoor unit (A) MODEL No. SPW-DR253GH56 Source 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) mm Centrifugal (1 … ø 220) W KFC4X-201B5P … 200 W 1 Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of pole…r.p.m.…
-
Indoor unit (B)
MODEL No. SPW-DR363GH56 Source 1 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) mm Centrifugal (1 … ø 220) W KFC4X-201B5P … 200 W Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of pole…r.p.m. (230 V, High)…
-
Indoor unit (C)
MODEL No. SPW-DR483GH56 Source 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) mm Centrifugal (1 … ø 250) W KFC4Q-401A5P … 400 W 1 Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of pole…r.p.m. (230 V, High)…
-
8-3. Other component specifications
-
8-4. Dimensional data
Indoor unit : 25, 36, 48 Type A A B C 25, 36 type type Refrigerant liquid line [ø 9.52 (In case of 25 type, use the tube connector.)] Drain pan × 100 = 700 22 - ø3.2 55 (Hole for full circumference) - ø3.2 (Hole for full circumference) × 100 = (Suspension bolt pitch) 90 60 1010 100 4-ø20 Hole for…
-
8-5. Noise criterion curves
MODEL MODEL : SPW-DR253GH56 : SPW-DR363GH56 SOUND LEVEL : HIGH 44 dB(A), NC 38 SOUND LEVEL : HIGH 45 dB(A), NC 39 CONDITION : Under the unit 1.5 m CONDITION : Under the unit 1.5 m SOURCE : 220 - 230 - 240 V, 1 Phase, 50 Hz SOURCE : 220 - 230 - 240 V, 1 Phase, 50 Hz NC-70 60 NC-60 50 NC-50 40 NC-40…
-
8-6. Indoor fan performance
How to Read the Diagram The vertical axis is the EXTERNAL STATIC PRESSURE (mmAq) while the horizontal axis represents the AIR FLOW (m3/minute). The characteristic curve for the “H”, “Med”, and “Lo” fan speed control. The name plate values are shown based on the “H” air flow. Therefore in the case of…
-
9-1. Specifications
Unit specifications (A) MODEL No. 1 Indoor Unit SPW-FR93GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating kW 2.8 3.2 BTU / h 9,600 11,000 Capacity 3 Air circulation (Hi / Me / Lo) m /h Moisture removal (High) Liters / h 420 / 360 / 300 1.3 — ELECTRICAL RATINGS Voltage…
-
Unit specifications (B)
MODEL No. Indoor Unit SPW-FR123GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating 3.6 4.2 12,000 14,000 Capacity kW BTU / h Air circulation (Hi / Me / Lo) m3 / h Moisture removal (High) Liters / h 1 540 / 420 / 360 1.7 — ELECTRICAL RATINGS Voltage rating V 220 - 230…
-
Unit specifications (C)
MODEL No. 1 Indoor Unit SPW-FR183GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating 5.6 6.3 19,000 21,000 Capacity kW BTU / h 3 Air circulation (Hi / Me / Lo) m /h Moisture removal (High) 900 / 780 / 660 Liters / h 2.5 — ELECTRICAL RATINGS Voltage rating V 220 - 230…
-
Unit specifications (D)
MODEL No. Indoor Unit SPW-FR253GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating 7.1 8 24,000 27,000 Capacity kW BTU / h m3 / h Air circulation (Hi / Me / Lo) Moisture removal (High) 1 1,020 / 840 / 720 Liters / h 3.5 — ELECTRICAL RATINGS Voltage rating V 220 - 230…
-
9-2. Major component specifications
Indoor unit (A) MODEL No. SPW-FR93GH56 Source 1 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) mm Centrifugal (1 … ø 153) W KFT6Q-11A3P … 15 W Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of pole…r.p.m.…
-
Indoor unit (B)
MODEL No. SPW-FR123GH56 Source 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) mm Centrifugal (1 … ø 153) W KFT4Q-21B3P … 20 W 1 Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of pole…r.p.m. (230 V, High) rpm.…
-
Indoor unit (C)
MODEL No. SPW-FR183GH56 Source 1 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) mm Centrifugal (2 … ø 153) W KFG4Q-61C3P … 60 W Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of pole…r.p.m. (230 V, High) rpm.…
-
Indoor unit (D)
MODEL No. SPW-FR253GH56 Source 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) mm Centrifugal (2 … ø 153) W KFG4Q-61C3P … 60 W 1 Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of pole…r.p.m. (230 V, High) rpm.…
-
9-3. Other component specifications
-
9-4. Dimensional data
Indoor unit : 9, 12, 18, 25 Type Size A B C Narrow tube Wide tube 9, 12 1065 665 632 9.52 12.7 18,25 1380 980 947 9.52 15.88 Type Side panel Refrigerant tubing space for downward tubing C B A 156 67 Air outlet R Air inlet 54 Rear-tube outlet 0755_M _I 4-Ø12 hole (For fastening the indoor unit to the…
-
9-5. Noise criterion curves
-
9-6. Air throw distance chart
9 Type Model: 12 Type HEATING 4.0 2.0 3.0 COOLING 3.0 2.0 4.0 1.0 5.0 0.0 0 1.0 2.0 3.0 4.0 5.0 6.0 HEATING 1.0 4.0 2.0 3.0 COOLING 3.0 2.0 4.0 1.0 5.0 0.0 FLOOR CEILING 5.0 HORIZONTAL DISTANCE (m) 0 1.0 2.0 3.0 4.0 5.0 0839_V_I Model: 18 Type Model: 25 Type CEILING 6.0 AIR OUTLET HEATING 0.0…
-
10. Conceal Floor-Standing Type (FM Type)
10-1.Specifications Unit specifications (A) MODEL No. 1 Indoor Unit SPW-FMR93GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating kW 2.8 3.2 BTU / h 9,600 11,000 Capacity 3 Air circulation (Hi / Me / Lo) m /h Moisture removal (High) Liters / h 420 / 360 / 300 1.3…
-
Unit specifications (B)
MODEL No. Indoor Unit SPW-FMR123GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating 3.6 4.2 12,000 14,000 Capacity kW BTU / h Air circulation (Hi / Me / Lo) m3 / h Moisture removal (High) Liters / h 1 540 / 420 / 360 1.7 — ELECTRICAL RATINGS Voltage rating V 220 - 230…
-
Unit specifications (C)
MODEL No. 1 Indoor Unit SPW-FMR183GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating 5.6 6.3 19,000 21,000 Capacity kW BTU / h 3 Air circulation (Hi / Me / Lo) m /h Moisture removal (High) 900 / 780 / 660 Liters / h 2.5 — ELECTRICAL RATINGS Voltage rating V 220 - 230…
-
Unit specifications (D)
MODEL No. Indoor Unit SPW-FMR253GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating 7.1 8 24,000 27,000 Capacity kW BTU / h m3 / h Air circulation (Hi / Me / Lo) Moisture removal (High) 1 1,020 / 840 / 720 Liters / h 3.5 — ELECTRICAL RATINGS Voltage rating V 220 - 230…
-
10-2. Major component specifications
Indoor unit (A) MODEL No. SPW-FMR93GH56 Source 1 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) mm Centrifugal (1 … ø 153) W KFT6Q-11A3P … 15 W Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of pole…r.p.m.…
-
Indoor unit (B)
MODEL No. SPW-FMR123GH56 Source 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) mm Centrifugal (1 … ø 153) W KFT4Q-21B3P … 30 W 1 Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of pole…r.p.m. (230 V, High)…
-
Indoor unit (C)
MODEL No. SPW-FMR183GH56 Source 1 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) mm Centrifugal (2 … ø 153) W KFG4Q-61C3P … 60 W Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of pole…r.p.m. (230 V, High)…
-
Indoor unit (D)
MODEL No. SPW-FMR253GH56 Source 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) mm Centrifugal (2 … ø 153) W KFG4Q-61C3P … 60 W 1 Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of pole…r.p.m. (230 V, High)…
-
10-3. Other component specifications
-
10-4. Dimensional data
Indoor unit : 9, 12, 18, 25 Type Size A B C D Narrow tube 9, 9.52 12.7 18,25 1173 1007 1002 980 9.52 15.88 Type Wide tube D A 166 Air outlet 229 B C (Internal dimension) Air inlet 0756_M_I 4-Ø12 hole (For fastening the indoor unit to the floor by screws.) Air filter Refrigerant connection outlet…
-
10-5. Noise criterion curves
-
10-6. Air throw distance chart
9 Type Model: 12 Type HEATING 4.0 2.0 3.0 COOLING 3.0 2.0 4.0 1.0 5.0 0.0 0 1.0 2.0 3.0 4.0 5.0 6.0 HEATING 1.0 4.0 2.0 3.0 COOLING 3.0 2.0 4.0 1.0 5.0 0.0 FLOOR CEILING 5.0 HORIZONTAL DISTANCE (m) 0 1.0 2.0 3.0 4.0 5.0 0839_V_I Model: 18 Type Model: 25 Type CEILING 6.0 AIR OUTLET HEATING 0.0…
-
10-7. Indoor fan performance
How to Read the Diagram it l Lim it l Lim 10 1 M 5 20 ine 2 L M 0 3 H H 10 1 (Pa) 20 External Static Pressure (mmAq) 2 ine (Pa) 12 Type 3 L External Static Pressure (mmAq) 9 Type Air Flow (m3/minute) Air Flow (m3/minute) 0843_V_I 0842_V_I 18 Type e t lin imi H L M 10 1 L (Pa) External Static…
-
11-1. Specifications
Unit specifications (A) MODEL No. Indoor Unit SPW-SLR93GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating 2.8 9,600 3.2 11,000 Capacity kW BTU / h 3 Air circulation (Hi / Me / Lo) m /h Moisture removal (High) Liters/h 1 840 (750)* / 630 / 540 0.6 — ELECTRICAL RATINGS…
-
Unit specifications (B)
MODEL No. 1 Indoor Unit SPW-SLR123GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating 3.6 12,000 4.2 14,000 Capacity kW BTU / h Air circulation (Hi / Me / Lo) m3/h Moisture removal (High) Liters/h 870 (780)* / 660 / 570 1.3 — ELECTRICAL RATINGS Voltage rating V Available…
-
Unit specifications (C)
MODEL No. Indoor Unit SPW-SLR183GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating 5.6 19,000 6.3 21,000 Capacity kW BTU / h 3 Air circulation (Hi / Me / Lo) m /h Moisture removal (High) Liters/h 1 900 (810)* / 690 / 600 2.5 — ELECTRICAL RATINGS Voltage rating V…
-
Unit specifications (D)
MODEL No. 1 Indoor Unit SPW-SLR253GH56 POWER SOURCE 220 - 230 - 240 V / 1 phase / 50Hz PERFORMANCE Cooling Heating 7.3 25,000 8.0 27,000 Capacity kW BTU / h Air circulation (Hi / Me / Lo) m3/h Moisture removal (High) Liters/h 1200 (1110)* / 990 / 780 3.3 — ELECTRICAL RATINGS Voltage rating V…
-
11-2. Major component specifications
Indoor unit (A) MODEL No. SPW-SLR93GH56 Source 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) mm Centrifugal (3) W SR4X - 31A3P... 30 W 1 Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of pole…r.p.m. (230 V…
-
Indoor unit (B)
MODEL No. SPW-SLR123GH56 Source 1 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) mm Centrifugal (3) W SR4X - 31A3P... 30 W Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of pole…r.p.m. (230 V, High) rpm. Ω…
-
Indoor unit (C)
MODEL No. SPW-SLR183GH56 Source 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y Fan (Number…diameter) CR-X253GH (Microprocessor) mm Centrifugal (3) W SR4X - 31A3P... 30 W 1 Fan motor Model…Nominal output Source No. of pole…r.p.m. (230 V, High) Coil resistance (Ambient temperature 20 °C)…
-
Indoor unit (D)
MODEL No. SPW-SLR253GH56 Source 1 220 - 230 - 240 V / 1 phase / 50Hz Controller P.C.B. Ass’y CR-X253GH (Microprocessor) Fan (Number…diameter) mm Centrifugal (4) W SFG4X - 51B5P... 30 W Fan motor Model…Nominal output Source 220 - 230 - 240 V / 1 phase / 50 Hz No. of pole…r.p.m. (230 V, High) rpm. Ω…
-
11-3. Other component specifications
-
11-4. Dimensional data
Indoor unit : 9, 12, 18, 25 Type B C D E 9, 12, 18 Type 1233 1193 1089 1003 660 25 Type 1430 1390 1286 1200 A 28 D *: Suspension bolt pitch **: For ceiling opening 5 ø12 610 88 ø137 Air intake grille Air outlet Refrigerant liquid line (ø 9.52) Refrigerant gas line (ø 12.7: 9, 12 type, ø 15.88: 18…
-
11-5. Noise criterion curves
-
11-6. Air throw distance chart
SPW-SLR93GH56 HORIZONTAL DISTANCE (m) AXIS AIR VELOCITY 1489_K_I SPW-SLR183GH56 HORIZONTAL DISTANCE (m) AXIS AIR VELOCITY (m/s) VERTICAL DISTANCE (m) 2 AXIS AIR VELOCITY 1490_K_I SPW-SLR253GH56 HORIZONTAL DISTANCE (m) AXIS AIR VELOCITY (m/s) VERTICAL DISTANCE (m) 1 AXIS AIR VELOCITY (m/s) VERTICAL…
-
2. Processes and Functions
1. Compressor Control II - 2 1-1. Compressor capacity control II - 2 1-2. Protection control II - 4 2. Reverse Cycle Defrosting II - 6 2-1. Frost detection II - 6 2-2. Defrost execution condition II - 6 2-3. Defrost end conditions II - 6 3. Reverse Cycle Starting Control II - 7 4. Outdoor Fan…
-
1-1. Compressor capacity control
-
(4) Special control of compressor
¶ Operation of the P/C compressor When current capacity is not 0, the compressor does not stop. ¶ AC compressor start delay (for outdoor units) When two compressors are to be started, the AC compressor is started 15 seconds after the P/C compressor. (22.4 kw, 28 kw outdoor units) ¶ For compressors…
-
1-2. Protection control
(1) Main principles If the current capacity decreases, it does not increase again for 3 minutes. (2) Evaporation temperature control (Freeze prevention) 1 Of the E1 and E2 indoor coil temperature of all the thermo-on indoor unit operating in cooling mode. The lowest is taken as the minimum…
-
Note 1 : When heating, if outdoor fan ≠ H , “current capacity increase allowed” is treated as “current capacity increase inhibited”. Note 2 : If the compressor maximum discharge temperature ] 100 ˚C (Liquid valve is ON), the “current capacity increase allowed” is treated as “current capacity…
-
2. Reverse Cycle Defrosting
¶ Defrost is accomplished through a reverse-cycle operation. ¶ During defrost operation, the outdoor fan is stopped and the indoor fan is either stopped or run at L or LL. 2-1. Frost detection (1) Frost is not monitored for the first 1 minutes of operation. (2) The frost detection conditions are…
-
3. Reverse Cycle Starting Control
At the start of heating operation, the cooling cycle operates for 50 seconds. During this time, the outdoor and indoor fans are stopped. Reverse-Cycle start conditions: (1) When starting heating operation after 60 minutes of stop operation (2) When starting heating operation for the first time after…
-
7. Outdoor Electronic Control Valve
(1) When the outdoor unit stops in cooling mode: 480 pulses When the outdoor unit stops in heating mode: 0 pulses (2) In cooling operation mode: 480 pulses In heating operation mode: control of degree of superheating (∆T = gas temperature - liquid temperature) of the heat exchanger ¶ ∆T should be 2…
-
9. Room Temperature Control
The thermostat is switched on/off by ∆T as follows. ∆T = (Room temperature) – (Set temperature) Remote control sensor Room temperature = remote control sensor detection temperature Body sensor Room temperature = (Body sensor detection temperature) – (Air-intake shift temperature*) * Shift…
-
10. Auto. Mode for Automatic Heating/Cooling Switching
A COOLING SELECTION TEMP. +2.5 deg SHIFT SET TEMP. +2 deg REMOTE CONTROLLED SET TEMP. B SHIFT SET TEMP. –2 deg HEATING SELECTION TEMP. –3 deg C 2 HEATING COOLING HEATING 0440_M_S Chart summary and Explanations ¶ This control is effective only for one indoor unit or group control. (1) This chart…
-
11. Heating Preparations
(1) After thermo.-on, until the set fan speed is reached, cool air is output (emanates) from this beginning heating operation and the indoor fan speed is controlled as shown below to prevent cold draft. ¶ When the fan speed is LL or off, “STAND BY” is displayed at the remote controller. • Room…
-
12. Dehumidifying Control
A: Normal cooling operation Room temperature (°C) +1 A B: Thermo-on • • • • • L : Low fan speed Thermo-off • • • • • LL : Very low fan speed Remote control temperature setting B 1268_M_I 13. Automatic Fan Speed Control 2 (1) When automatic fan speed is selected with the remote controller, the indoor…
-
14. Auto-flap Control
14-1. X, S, T Type The auto-flap controls the air flow to one of the five vertical levels. X type (4-way), S type (2-way) T type Auto-flap F1 20° F2 60° F3 F1 40° F4 F4 Cooling F1~F3 Heating F1~F5 F2 F5 F3 F5 1267_M_I Operation mode Cooling / drying Fan Heating Heating preparation Flap position…
-
(1) Drain pump control turns ON when the compressor is activated in cooling operation. (2) When the compressor turns OFF due to freeze prevention control, drain pump turns ON for 20 minutes. (3) Drain pump control turns ON when the floating switch is activated. If the operation is performed for 5…
-
17. Discharge Temperature Control (Only for U, D Type)
¶ If the range shown below is continuously detected for 6 minutes, the unit will thermo-off operation is initiated. Room temp. (deg) A +2 A: Thermo-off range in heating B: Thermo-off range in cooling (drying) Discharge Set temp. -2 B 1248_M_I *1. The discharge temperature was factory set as follows…
-
3. Service Procedures
1. Troubleshooting III - 2 1-1. Check before and after troubleshooting III - 3 1-2. General troubleshooting flow chart: diagnosis and remedy III - 6 1-3. Explanation of alarm messages III - 8 1-4. Alarm messages on the outdoor PCB III - 10 1-5. Symptoms and parts to inspect III - 11 1-6. Procedures…
-
This section explains
❏ What the LED codes mean ❏ What the remote controller display (screen) messages mean ❏ How to use the flow charts to find and solve problems ❏ How to use the self-diagnostic tests to find parts which don’t work right 3 This unit is made to be trouble free, and not need much service. However, with…
-
1-1. Check before and after troubleshooting
Many problems may happen because of wiring or power supply problems, so you should check these areas first. Problems here can cause false results in some of the following tests, and so should be corrected first. ¶ Since the check of interior of outdoor unit is very hazardous, always cut off its…
-
Wiring system diagram
Indoor unit (No. 1) L Power supply 220-240V 50Hz N 2 3 Ground Remote controller RED 1 WHT 2 BLK 3 Outdoor unit (No. 1) 1 B C D Ground A L1 L2 L3 N Power supply 380-415V-3N 50Hz Ground 2 Ground 3 C Indoor unit (No. 2) L Power supply 220-240V 50Hz N 1 R.C. Address : 1 (S002, BLK) Ground C Ground…
-
CAUTION
(3) Don’t install the inter-unit control wiring such as star branch wiring. Star branch wiring causes mis-address setting. Outdoor unit NG Outdoor unit NG Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit Branch point 0824_M_I (4) If branching the inter-unit control…
-
1-2. General troubleshooting flow chart: diagnosis and remedy
When you have found a major problem, such as refrigerant not flowing in the system or reduced air circulation, come to this section and find the box listing the problem. Connected to the box are the main causes of the problem and their remedies. To find out which malfunction is happening in your…
-
(B) Heating
b. Heating Poor heating Is setting temp. suitable ? Change the setting temp. Is heating load too large ? Review heating load estimate. 4-way valve is defective. Replace the valve. Refrigerant shortage Charge with refrigerant. Electronic refrigerant control valve is defective. Replace the valve.…
-
1-3. Explanation of Alarm Messages
Possible Cause of Malfunction • Serial communication errors • Mis-setting Remote controller is detecting error signal from indoor unit. Error in receiving serial communications signal. Error in transmitting serial communications signal. Alarm message E1 E2 • Indoor unit is detecting error signal…
-
Alarm
message Possible Cause of Malfunction Thermistor failure Indoor thermistor is either open or damaged. Outdoor thermistor is either open or damaged. Indoor coil temp. (E1=TH1) cannot be detected. F1 Indoor coil temp. (E2 = TH2) cannot be detected. F2 Indoor coil temp. (E3 = TH3) cannot be detected.…
-
1-4. Alarm Messages on the Outdoor PCB
(In ordinary use, the outdoor alarm LED (yellow) is off and the LED (red), which indicates the number of connected indoor units, is turned on.) Alarm messages indicated by the LED (red) on the outdoor PCB. ● When the outdoor alarm LED (yellow) is OFF, the LED (red) lamps blink display on the remote…
-
1-5. Symptoms and parts to inspect
(1) Symptom: LCD on the remote controller does not display and remote controller does not operate. Start Is the LED (D80) on Yes the indoor unit PCB lit? No Is there 12 V DC Yes between R2 and R3 on the 8P terminal plate of the indoor unit? No Miswiring of power supply wires and indoor/outdoor…
-
(2) Symptom: LCD on the remote controller displays “CHECK E01”. (Unusual communication between remote controller and indoor unit, or R.C. address, indoor unit address, or group address in indoor unit nonvolatile memory are not set. 1 For only 1 system (outdoor unit system address 0) ¶ The first time…
-
(3) Symptom: LCD on the remote controller displays “CHECK E02”. (Unusual communication between remote controller and indoor unit) Start Is the No. 1 line wire (red) for the remote controller connected to another line (2 or 3) or are No. 1 and No. 3 (black) wired reversed? Yes Repair the wiring. No…
-
(4) Symptom: LCD on the remote controller is displaying “CHECK E04”. (Unusual communication between the indoor and outdoor units or inappropriate combination of indoor and outdoor units) 1 The outdoor unit cannot communicate with the indoor unit. Or the power supply to the outdoor unit is off. 2…
-
(6) Symptom: LCD on the remote controller is displaying “CHECK E06”. (Unusual communication between the indoor and outdoor units) 1 This message is displayed when the power was switched on for the indoor and outdoor units, the combination of indoor and outdoor units matches, but afterwards a problem…
-
(9) Symptom: LCD on the remote controller is displaying “CHECK E15” or “CHECK E16”. (Inappropriate indoor combination) 1 When the outdoor unit judges a mismatch between the number of connected indoor units and the mumber of indoor units set at the outdoor unit (S004) after automatic address setting…
-
(12) Symptom: LCD on the remote controller displays “CHECK P02”. (Compressor / outdoor fan protection thermostat) Start Is the power supply to the outdoor No unit normal? (Voltage defective phase?) Check the power breaker etc. and repair. Yes Yes Is there 220-240 V AC between CN52-2 and CN40-3 of…
-
(13) Symptoms: LCD on the remote controller displays “CHECK P03”
(Alarm for unusual PC comp, discharge temp.) The remote controller LCD displays “CHECK P17”. (Alarm for unusual PC comp, discharge temp.) Start Yes Unusual discharge gas temperature • Gas shortage • Clogged refrigerant circuit • Electronic refrigerant control valve defect (indoor unit) •…
-
(15) Symptom: LCD on the remote controller displays “CHECK P05”. (Reversed phase detection)
Start Is the power supply to the outdoor unit normal? (Voltage defective phase?) No Check the power breaker etc. and repair Yes Are two of the phases of the power for the outdoor unit reversed? (Reverse phase detected alarm) Yes No problem No Is there a contact defect in the 3P connector (CN40…
-
(17) Symptom: LCD on the remote controller displays “CHECK H11, H12, H13”. (AC compressor current detection) Start “CHECK H11” display “CHECK H12” display “CHECK H13” display Compressor overload detection Compressor lock detection Compressor current detection circuit defect • Insufficient voltage •…
-
1-6. Procedures when a specific component does not work at all
(1) Check the indoor unit (When the alarm of transmission failure is not activated) ¶ In case that the unit is controlled by Flexible Combination, an electronic control valve failure has occurred or one of the units cannot be controlled due to electronic control valve circuit failure, and other…
-
(3) Outdoor fan is not running at all
Are auxiliary relays (1Y, 2Y) No Replace the relays. normal ? Yes Is fan motor capacitor normal ? No Replace the capacitor. Yes Is there voltage output of No Replace P.C.B. Ass’y P.C.B. Ass’y for fan motor ? in the outdoor unit. Yes Check resistance of fan motor winding. NG 3 Replace the fan motor.…
-
1-7. Service functions of remote controller
From the remote controller you can control both the operation and settings of the unit as well as perform several useful service checks. This section explains how to use the remote controller on the following items from (A) to (J). (A) Set service check switches. (B) Use the test run procedure. (C)…
-
The purpose of the test run function is to let you control the operation of the unit directly without turning the unit on or off by thermostat. As indicated in the following procedure, be sure to stop test run operation when you finish the procedure, or the air conditioner may be damaged because it…
-
(C)
Check the sensor temperature readings The air conditioner has thermo sensors which are used to control the unit. ❏ Each sensor has an address which is made up of the indoor unit address, and the sensor address. The indoor unit address is used only when several units are hooked up to one remote…
-
Refer to the table below for the relationship between the sensor address and the location of the sensor. Relationship between the sensor address and the location of sensor Sensor Address (CODE No.) Indoor Unit Location of Sensor (Themistor) Outdoor Unit 0A 0B 0C 0D 0E 0F ( TH1 TH2 TH3 TH4 — Indoor…
-
This picture shows the service check display
UNIT No. UNIT No. 1–1 R.C. No. Refrigerant Circuit No. No. CODE No. CODE No. CHECK Alarm message SERVICE 0358_M_I c. A maximum of 4 alarm messages can be accessed by pressing either SET TEMP button or as follows. MODE NOTE Pressing CL (Clear) button will clear all the service history. Past SET TEMP.…
-
Important
Never press CL (clear) button unless you want to erase the accessed data in memory. Follow the procedure below only when erasing is necessary. ❏ To erase accessed data, press the CL button. ❏ When erasing is finished,“----” mark appears on the controller’s display. CAUTION After checking the alarm…
-
(F)
Execute the auto. address operation ❏ Auto. address operation is executed by pressing the A. ADD button of outdoor unit’s PCB usually (See “Test Run” V-2 ~). For your convenient it can be executed by remote controller also. a Press the TEST / CHK and b Set CODE No. A1 with ( , ) buttons at the same…
-
(G) Confirm and change the indoor unit address
❏ a The purpose of the above function is to let you confirm the indoor unit address after the auto. address operation, and change the indoor unit address if it is needed. Press the TEST / CHK and ( AIR FLOW UNIT FLAP ) buttons at the same time for more than 4 seconds. MODE R.C. CODE No. SET TEMP.…
-
e
Set the required new indoor unit’s No. by pressing the AIR FLOW UNIT FLAP , ( ) button. MODE R.C. Ex: UNIT No. 3-6: currently registered indoor unit address No. CODE No. SET TEMP. TIMER SET FAN SPEED SETTING SET DATA SET Required new indoor No.8: SET DATA CL * In this case, UNIT No. 3 ≠– 6 (current)…
-
(H) Change the shift temperature in heating mode
a ❏ If the indoor unit is installed at high location (ex. ceiling level), the thermostat tends to turn off at heating mode because of the hot air temperature around ceiling level. In order to solve the problem, the shift temp. (valid while heating only) is set when shipped from factory. ❏ If the…
-
(I)
Set the indoor unit address ❏ This function is usable if the auto. address operation is not available. Indoor unit address can be set one by one by remote controller in such case. NOTE 1) In case of group control, branch wiring for group control should be removed temporarily. 2) In case of remote…
-
d
Set the No. of R. C. which you want to set with AIR FLOW UNIT FLAP , ( ) button. Ex. No. of R. C. will be set 2. MODE UNIT No. R.C. No. CODE No. SET TEMP. TIMER SET FAN SPEED SETTING SET DATA SET CL ON • OFF • TEST / CHK 0369_M_I e Press the SET button. UNIT No., CODE No. 12, SETTING and SET DATA…
-
i
Select the code No. 14 to set group setting with the j Set the No. of group setting as shown below with the AIR FLOW UNIT FLAP (SET TEMP) button. , ( ) button. Nos. of group setting. MODE UNIT No. R.C. 0 : Standard system (except group control) No. CODE No. SET TEMP. 1 : Main indoor unit in case of…
-
(J)
Change the period of the filter timer ❏ a If the period of filter timer is not suitable (for example in case of dirty environment), the period can be shortened to half as follows: Press the TEST / CHK button for more than 4 seconds. AIR FLOW UNIT FLAP MODE UNIT No. R.C. No. SET TEMP. CODE No. TIMER…
-
2-1. Outdoor unit
7 SPW-CR363GVH8, SPW-CR363GV8 7 SPW-CR483GVH8, SPW-CR483GV8 High Pressure Valve L1 INJ. Valve (LIV) Low Pressure Valve (LPV1) Save Valve (SAVE) Low Pressure Valve (LPV2) Low Pressure Valve (LPV3) Four Way Valve (20S) Motor Operated Valve* Coil GAS Secsor (TH2)* 3 Air Suction TEMP (TH4) Compressor…
-
7 SPW-CR703GVH8, SPW-CR903GVH8
-
2-2. Indoor unit
-
7 SPW-KR93GH56
-
7 SPW-TR183GH56
-
7 SPW-DR253GH56
-
7 SPW-SLR93GH56, SPW-SLR123GH56
-
3. Thermistor Characteristic Curve
-
4-1. PCB Setting & Test Run
¶ Setting of outdoor PCB (A) Set the number of indoor units which are connected to the outdoor unit in S004. a For example in the case of 13, set “D” in S004. b If the number of indoor units and the number of set switches are identical, the LED: 1 to 8 (9~16) light up matching the number of indoor…
-
● Test run procedure
Start Multiple remote control? Yes Turn on RCU. ADR switch of sub-remote controller No S004 S002 & S003 CN031(open*) : For link system Setting of outdoor control PCB NOTE *One of CN031 of all linked outdoor units should be short. Check the confirmation items before the test run Press the S001(A.ADD)…
-
4-2. Main Alarm Messages which Indicate Mis-Wiring & Mis-Setting
Remote controller display Cause Group Control • Individual Remote Control Multiple Remote Control Nothing • Remote controller not properly connected. displayed • Power supply not ON. E1 • Remote controller not properly connected. E4 • Wiring connection fault of indoor/outdoor units • Wiring…
-
CN79 (RED) : HU1 CN77 (GRN) : LM CN85 (BLU) : DPH CN74 (WHT) : RN2 CN76 (BLK) : OP1 CN73 (BLK) : RN1 CN78 (BLU) : DP CN84 (WHT) : RN3 F1 : Fuse 250V / 5A CN81 (GRY) : T20 CN80 (RED) : 26H D80 (RED) : Power lamp CN75 (WHT) : VCC CN83 (WHT) : FM JP1 (Jumper wire) : For sellecting the signal of T10.…
-
7 Outdoor unit control PCB (CR-CR483GVH)
-
7 Outdoor unit control PCB (CR-CR703GVH)
-
6. Check of Density Limit
NOTE Important The room in which the air conditioner is to be installed requires a design that in the event of refrigerant gas leaking out, its density will not exceed a set limit. The refrigerant R-407C which is used in the air conditioner is safe, without the toxicity or combustibility of ammonia…
-
7. Cautions for New Refrigerant R407C
1 Care regarding piping 1-1. There is no need to change piping and tube wall thickness. Use refrigerant pipes of the same wall thickness as R22. Type 0 Outer diameter Copper tube ø6.35 ø9.52 1/2 H, H ø12.7 ø15.88 ø19.05 ø22.2 ø25.4 ø28.58 Wall thickness 0.8 0.8 0.8 1.0 1.0 1.2 1.0 * C1220 type with…
-
7. Cautions for New Refrigerant R407C
New refrigerant R407C cannot be used for existing models. 1. Compressor specs are different. When refilling the R22 compressor with R407C, durability will significantly decresae since some of the materials used for compressor parts are different. 2. Existing piping cannot be used. Completely…
-
8. Compressor Failure
8-1. Trouble shooting and method for checking the compressor Generally, compressor failures are classified into the following items. (1) Mechanical trouble 1 Locking (dust, scoring, etc.) 2 Pressure shortage (damaged parts such as valves, tools, spare rings, etc.) 3 Abnormal sound (damaged parts…
-
9. Operation Procedure for Replacing the Compressor
9-1. Preperation Compressor cover ceiling plate Fan guard Operate correctly according to the procedure below. Front cover (1) Turn off the indoor and outdoor unit switches. Turn on the indoor switch again, and after 1 minute, turn off. (This is to completely open the electronic refrigerant control…
-
9. Operation Procedure for Replacing the Compressor
9-3. Installation (1) Be sure to avoid air and moisture in the refrigerant system. Remove the rubber plug and suction pipe cap from the new compressor. Pipe holding Fixtures A 1243_C_I (2) Install the crank case heater on the compressor. (3) Put the compressor rubber cushion on the prescribed…
-
10. Malfunction due to Noise
Since communication control is performed by pulse signals, the unit is susceptible to external noise. The circuitry has been designed in consideration of external noise and troubles should not occur in ordinary use. However, depending on the installation conditions, there may be trouble caused by…
-
12. Check Pins
12-1. Indoor PCB (Printed Circuit Board) If the check pins on the indoor PCB (Printed Circuit Board) are short-circuited, output operation for each unit can be performed independently. ● If the FORCED OPR pins (CN5, white) are short-circuited, the indoor unit enters the operation mode listed in the…
-
4. Electrical Data
-
GRN/YEL
B 52C R RED T 31 T 49C V W 32 S CM S U RED BLU BLU R GRY A WHT WHT RED CT GRY To Indoor Unit Terminal Plate (2P) CH P 1 2 Connector S 1 2 2P(RED) ORG GRY BLU WHT RED GRN/YEL BLK BLK BRN Terminal Plate (6P) YEL BRN L1 L2 L3 N GRN/YEL GRN/YEL FMO1 49FO1 3P(WHT) CTPC 1 3 3P(RED) 52C 1 3 6P(WHT) CN59…
-
(1) SPW-CR363GVH8, SPW-CR483GVH8
-
GRN/YEL
B 52C R T 31 T 49C V W 32 S CM S U R BLU RED RED BLU CT GRY A WHT WHT RED GRY 1 2 To Indoor Unit Terminal Plate (2P) CH P 1 2 Connector S 1 2 2P(RED) ORG GRY BLU WHT RED GRN/YEL BLK BLK BRN Terminal Plate (6P) YEL BRN L1 L2 L3 N GRN/YEL GRN/YEL FMO1 49FO1 3P(WHT) CTPC 1 3 3P(RED) 52C 1 3 6P(WHT)…
-
(A2)
52C 1 U R R T CM1 S V W S T WHT WHT A (A1) RED RED BLU BLU 49C1 GRN/YEL 32 31 CT1 6 GRN/YEL YEL BRN B (A2) BRN A (A1) PNK 52C 2 WHT ORG BRN BLK BLK BLU WHT RED U R R T CM2 S V W S T 32 31 49C2 WHT PNK RED BLK BLK BLK GRY CT2 RED 1 CN10 CN11 3 (WHT) (GRN) 1 3 CN122 CN124 BRN 2 2 BRN 1 1 P S Connector…
-
52C1
-
(A2)
-
52C1
-
L
2 N To Remote Control Switch 3 U1 U2 R1 R2 R3 Unit Control Line E FS DP MOV T6 (WHT) 1 3 DP (BLU) VCC(WHT) 1 3 R N RN2(WHT) SG 12V G RC(BLU) FS (RED) 1 2 SG1 SG2 OC(BLU) 1 3 R N RN1(BLK) TR1 AC 230V GRN/YEL BLK BLK RC1 FMI 49FI GRN/YEL 1 4 S Connector P 9P(WHT) T20(GRY) Controller (CR-X253GH) LL L H…
-
N
To Remote Control Switch 3 U1 U2 R1 R2 R3 E Connector 2P(BLK) 1 3 P 1 2 S 1 2 FS DP (BLU) DP TR1 AC 230V GRN/YEL SG 12V G RC(BLU) FS (RED) 1 2 SG1 SG2 OC(BLU) 1 3 R N RN1(BLK) PNK BLU 1 Terminal Plate(8P) GRN/YEL BLK BLK BLK BLK RED WHT BLK L RED BRN Unit Control Line GRN/YEL P S Connector 3P(WHT)…
-
E FS DP 1 3 RED RED BRN BRN Connector S 6P(WHT) P DP (BLU) 1 3 TR1 AC 230V GRN/YEL SG 12V G RC(BLU) FS (RED) 1 2 SG1 SG2 OC(BLU) 1 3 R N RN1(BLK) PNK BLU N WHT WHT VCC(WHT) 1 3 R N RN2(WHT) WHT WHT L RC1 FMI 49FI GRN/YEL 1 4 S Connector P 8P(WHT) T20(GRY) TH1 TH2 TH4 W 854-2-5268-411-00-2 (AS) TH3…
-
(3) SPW-ASR93GH56, SPW-ASR123GH56
-
E AC 230V TR1 GRN/YEL Terminal Plate(3P) 1 3 R N RN2(WHT) SG 12V G RC(BLU) FS (RED) 1 2 SG1 SG2 OC(BLU) PNK BLU R N RN1(BLK) NF 1 RED WHT BLK N RED RED BRN BRN VCC(WHT) RC1 S 1 P FMI Connector 8P(WHT) 49FI GRN/YEL T20(GRY) P 1 S LM TH1 TH2 TH4 W 854-2-5268-410-00-3 (K) TH3 (BRN) Coil E3 LM (GRN) 1 3…
-
E 1 2 OC(BLU) 1 3 PNK BLU RN1(BLU) RC(BLU) RED WHT BLK 1 TR1 AC 230V GRN/YEL 1 3 RC1 FMI 49FI GRN/YEL S Connector P 9P(WHT) LSW Connector P 1 2 2P(WHT) TH1 TH2 TH4 W 854-2-5268-665-00-0 (TR) TH3 (BRN) Coil E3 (YEL) Room Temp (BLK) Coil E2 T6 (WHT) DP (BLU) P Connector S 4P(WHT) LM 1 3 FS (RED) (RED)…
-
N
3 U1 U2 R1 R2 R3 E Connector 2P(BLK) 1 3 P 1 2 S 1 2 FS DP (BLU) DP GRN/YEL T6 (WHT) VCC(WHT) 1 3 R N RN2(WHT) Connector 2P(WHT) 1 2 P 1 2 S TR1 AC 230V GRN/YEL SG 12V G RC(BLU) FS (RED) 1 2 SG1 SG2 OC(BLU) 1 3 R N RN1(BLK) PNK BLU L To Remote Control Switch MOV RC1 FMI 1 4 P S Connector 9P(WHT)…
-
L
2 N 3 U1 U2 R1 R2 R3 To Remote Control Switch E Connector 2P(BLK) 1 3 FS (RED) 1 2 SG1 SG2 OC(BLU) 1 3 R N RN1(BLK) P 1 2 S 1 2 FS DP (BLU) SG 12V G R N RC(BLU) RN2(WHT) TR1 AC 230V GRN/YEL WHT WHT Unit Control Line DP GRN/YEL Connector 2P(WHT) 1 2 P 1 2 S RC0 FMI 1 49FI1 GRN/YEL S Connector P…
-
E 1 3 Connector P 1 2 2P(BLK) S 1 2 FS AC 230V TR1 P 1 2 Connector S 1 2 2P(BLK) BLK RC1 FMI 49FI P 1 2 Connector 2P(WHT) S P Connector 5P(WHT) MOV TH1 TH2 TH4 W 854-2-5268-693-00-0 (DR) TH3 (BRN) Coil E3 1 2 (BLK) Coil E2 1 2 (RED) Coil E1 (YEL) Room Temp PNL (GRN) 1 2 Discharge Air (GRN) T6 (WHT)…
-
(7)-1 SPW-DR253GH56
-
E 1 3 Connector P 1 2 2P(BLK) S 1 2 FS AC 230V TR1 1 3 R N RN2(WHT) SG 12V G RC(BLU) P 1 2 Connector S 1 2 2P(BLK) BLK FS (RED) 1 2 SG1 SG2 OC(BLU) 1 3 PNK BLU R N RN1(BLK) RED WHT BLK 1 GRN/YEL FMI P 1 2 Connector 2P(WHT) S P Connector 5P(WHT) MOV TH1 TH2 TH4 W 854-2-5268-694-00-0 (DR) TH3 (BRN)…
-
(7)-2 SPW-DR363GH56
-
E 1 3 Connector P 1 2 2P(BLK) S 1 2 FS RED TR1 AC 230V F0 1 3 R N RN2(WHT) SG 12V G RC(BLU) P 1 2 Connector S 1 2 2P(BLK) BLK FS (RED) 1 2 SG1 SG2 OC(BLU) 1 3 GRN/YEL R N RN1(BLK) Terminal Plate(8P) PNK BLU PNK BRN P 1 2 Connector 2P(WHT) MOV TH1 TH2 TH3 2 2 TH5 W 854-2-5268-695-00-0 (DR) TH4…
-
(7)-3 SPW-DR483GH56
-
E T6 (WHT) 1 3 FS (RED) MOV RC1 S 1 P LL L H HH R N RN3(WHT) FM (WHT) 1 4 FMI PNL (GRN) TH1 TH2 TH3 TH4 1 3 (BRN) Coil E3 1 2 (BLK) Coil E2 DPH (BLU) 1 2 (RED) Coil E1 S 1 P (YEL) Room Temp T20(GRY) DPH W 854-2-5268-558-00-0 (FR93GH56, FR123GH56, FR183GH56, FR253GH56) S P Connector 5P(WHT) Connector…
-
E T6 (WHT) 1 3 FS (RED) S 1 P LL L H HH R N RN3(WHT) FM (WHT) 1 4 FMI S P Connector 5P(WHT) Connector 8P(WHT) 49FI 1 3 TH1 TH2 TH3 TH4 (BRN) Coil E3 1 2 (BLK) Coil E2 (RED) Coil E1 (YEL) Room Temp PNL(GRN) T20(GRY) W 854-2-5268-559-00-0 (FMR93GH56, FMR123GH56, FMR183GH56, FMR253GH56) MOV RC1 GRN/YEL…
-
(9) SPW-FMR93GH56, SPW-FMR123GH56, SPW-FMR183GH56, SPW-FMR253GH56
-
N
To Remote Control Switch 3 U1 U2 R1 R2 R3 E DP Connector P 1 2 2P(WHT) S 1 2 GRN/YEL DP (BLU) VCC(WHT) 1 3 R N RN2(WHT) Connector P 1 2 2P(BLK) S 1 2 FS TR1 AC 230V GRN/YEL RED RED BRN BRN SG 12V G RC(BLU) FS (RED) 1 2 SG1 SG2 OC(BLU) 1 3 R N RN1(BLK) PNK BLU L Unit Control Line RC1 FMI T6 (WHT) MOV…
-
(10) SPW-SLR93GH56, SPW-SLR123GH56, SPW-SLR183GH56, SPW-SLR253GH56
-
• The specifications, designs, and information in this brochure are subject to change without notice. SANYO Electric Co., Ltd. Osaka, Japan G1299 G 500 Printed in Japan
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.