Технический каталог Ebara 2022 - Насосные станции GP 2CDX
Технический каталог Ebara 2022 - Насосные станции GP 2CDX 50Hz
Загружаем документ…
Текст каталога
-
GP 2CDX
Data Book 50Hz
-
CONTENTS
Page INDEX 2 DEFINITION AND USE OF PRESSURISATION UNITS 101 TYPICAL APPLICATIONS 101 OPERATING CONDITIONS 101 TESTS AND TRIALS 101 MECHANICAL AND HYDRAULIC TESTS 101 ELECTRICAL TESTS 102 PRINCIPLE OF OPERATION OF GP PRESSURISATION UNITS 102 Principle of Operation of GPE Pressurisation UNITS with…
-
CONTENTS
2GP(.) 2CDX 200/50 414 2GP CONSTRUCTION 601 EXTERNAL VIEW 2GP 2CDX 601 OVERALL DIMENSIONS 2GP BOOSTER SET 602 2GP 2CDX 602 PACKING 603 CONTROL PANEL FIXED SPEED 801 2EP-E SPECIFICATION 801 CONTROL PANEL VARIABLE SPEED 803 E-SPD+ SPECIFICATION 803 SP (EFC and MFC) SPECIFICATION 804 PROTECTION PANEL…
-
INTRODUCTION
1 In situations in which a municipal water mains is lacking or insufficient for the proper operation of the services, one must install a pressurization unit to provide acceptable pressure and flow rates to even in the most unfavourable services. Pressurisation units are used wherever there is a need…
-
INTRODUCTION
1 • Earthing system continuity • Applied voltage (dielectric rigidity) • Insulation resistance PRINCIPLE OF OPERATION OF GP PRESSURISATION UNITS When water is demanded, it is first drawn from the autoclave tank (if present). This demand for water, with the pumps stopped, lowers the pressure until…
-
INTRODUCTION
Principle of Operation of GPE Pressurisation UNITS with an MFC control panel MFC multiple pump control panels power each pump with an INVERTER to modulate system performance in relation to the reference signal. MFC controllers differ from EFC controller from the point of view of their construction…
-
INTRODUCTION
1 INTRODUCTION Fig. 1 - TWO PUMP UNIT WITH CONSTANT PRESSURE REGULATION GP PRESSURISATION UNIT WATER CIRCUIT DIAGRAM 104 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
INTRODUCTION
1 INTRODUCTION GPE PRESSURISATION UNIT WATER CIRCUIT DIAGRAM 105 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
INTRODUCTION
1 TYPE KEY 2 GPE space 2CDX 70/10 M space EFC Control type Null = Fixed speed EP-E up to 7,5kW fixed speed EP from 11kW and above EFC = Single Inverter SP-EFC MFC = Multi Inverter SP-EFC ESPM = E-SPD+ MT (Inlet voltage 230V single phase) ESPT = E-SPD+ TT (Inlet voltage 400V three phase) Phase…
-
TECHNICAL DATA
2 PRODUCT SPECIFICATIONS BOOSTER SET 2CDX Version Nominal flow rate ( m3/h ) Operating range Single pump 4.8 9.0 12.6 2GP 9.6 18.0 25.2 Maximum working pressure 8 bar Liquid temperature range 0÷+60°C [1] Ambient operating temperature (no higher than 1000 m above sea level) Hydraulic components…
-
TECHNICAL DATA
2 ELECTRIC PANEL Version Operating range Control panel Nominal flow rate ( m3/h ) Single pump 4.8 9.0 12.6 2GP 9.6 18.0 25.2 Principal Electric panel TECHNICAL DATA BOOSTER SET 2CDX EP-E fixed speed TECHNICAL PUMP DATA PUMP 2CDX Version Operating range Liquid handled Maximum working pressure 0.8 Mpa…
-
TECHNICAL DATA
2 TECHNICAL MOTOR DATA Frequency Phase Power source TECHNICAL DATA MOTOR 2CDX 50 Hz Single-phase Rotation speed Three-phase 2800 min-1 0.75 ÷ 1.5 kW 0.75 ÷ 3.7 kW 1 ÷ 2 HP 1 ÷ 5 HP 230 ± 10% V 230/400 ± 10% Power rating Voltage Type Efficiency level Type Electric - TEFC IE3 from 0.75 kW up to 3.7 kW…
-
CURVE SPECIFICATION
4 PERFORMANCE RANGE RESEAU BOOSTER SET 2GP(.) 2CDX CURVE SPECIFICATION GP-GPE 401 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
SELECTION CHART
4 CURVE SPECIFICATION 2GP(.) Tolerances according to ISO 9906:2012 – Grade 3B. The curves refer to effective speed of asynchronous motors at 50 Hz 2 poles Measurements were carried out with clean water at 20°C of temperature and with a kinematic viscosity of = 1 mm2/s (1 cSt). The NPSH curve is an…
-
SELECTION CHART
4 SELECTION CHART 2GP(.) 2CDX SELECTION CHART GP-GPE 403 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
PERFORMANCE CURVE 2GP(.) 2GP(.) 2CDX 70/10 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 404 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) 2CDX 70/12 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 405 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) 2CDX 70/15 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 406 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) 2CDX 70/20 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 407 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) 2CDX 120/15 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 408 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) 2CDX 120/20 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 409 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) 2CDX 120/30 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 410 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) 2CDX 120/40 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 411 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) 2CDX 200/30 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 412 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) 2CDX 200/40 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 413 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) 2CDX 200/50 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 414 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
CONSTRUCTION
6 2GP CONSTRUCTION CONSTRUCTION EXTERNAL VIEW 2GP 2CDX N° PART NAME Principal pump Electric motor Baseplate Baseplate foot Suction manifold Union ball valve Check valve Threaded female cap Nipple for air feeders Discharge manifold Union ball valve Threaded female cap Control panel Control panel…
-
DIMENSIONS AND WEIGHT
-
DIMENSIONS AND WEIGHT
7 DIMENSIONS AND WEIGHT PACKING 2GP Booster type 2GP 2CDX 70/10(M) 2GP 2CDX 70/12(M) 2GP 2CDX 70/15(M) 2GP 2CDX 70/20(M) 2GP 2CDX 120/15(M) 2GP 2CDX 120/20(M) 2GP 2CDX 120/30 2GP 2CDX 120/40 2GP 2CDX 200/30 2GP 2CDX 200/40 2GP 2CDX 200/50 Overall dimensions packing X Y Z 1230 830 1365…
-
CONTROL PANEL
8 CONTROL PANEL FIXED SPEED 2EP-E SPECIFICATION Electrical panel (protection and control) for two electropumps. Manual or automatic operation through pressure transmitter or/and pressure switches. The panel is configured to start the two pumps alternately in stand-by to pressure transmitter or/and…
-
таблицы и схемы — в просмотре
-
CONTROL PANEL
8 CONTROL PANEL VARIABLE SPEED E-SPD+ SPECIFICATION CONTROL PANEL On boad electronic device for controlling electropumps, employing inverter technology. Starts and stops the pump and modulates the speed of the motor in relation to the water demand on the system, to maintain the operating pressure…
-
CONTROL PANEL
8 SP (EFC and MFC) SPECIFICATION The control panels SP EFC/MFC series inverters modulate the operation of electropumps in response to control by the pressure transmitter (transducer measuring flow or other external signal 4-20 mA), regulating the speed of the electropumps to keep system demand…
-
таблицы и схемы — в просмотре
-
CONTROL PANEL
8 PROTECTION PANEL SPECIFICATION Connection box for inverter : - Connects the inverters with the power supply point. - Equipped with circuit breakers on individual lines Frequency Phase Single-phase Three-phase Voltage 230 V ± 10% 400 V ± 10% Power 0.37 ÷ 3 kW 0.37 ÷ 15 kW Protection degree Others…
-
EBARA Corporation
11-1, Haneda Asahi-cho, Ota-ku, Tokyo 144-8510 Japan Tel. +81 3 6275 7598 Fax +81 3 5736 3193 www.ebara.com I contenuti della presente pubblicazione non devono essere considerati impegnativi. EBARA Pumps Europe S.p.A. si riserva il diritto di apportare senza preavviso le modifiche che riterrà più…
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.