Каталог промышленных горелок CIB Unigas 2022
Технический каталог горелок для промышленного применения 2022/1-2023 (M029118CA Rel. 0): газовые, жидкотопливные и комбинированные горелки, технические характеристики, рабочие диапазоны, размеры. Документ на английском языке.
Загружаем документ…
Текст каталога
-
TECHNICAL CATALOGUE Burners for Industrial Applications 2022/1-2023 www.cibunigas.it
-
TECHNICAL CATALOGUE Burners for Industrial Applications 2022/1-2023 www.cibunigas.it
-
WE UNDERSTAND YOUR MARKET The worldwide success of CIB UNIGAS products is due to our adaptability. In fact we are able to adapt our know-how to the different market requests. As a demonstration of this ability, now the 85% of our turnover comes from exports, in particular from Russia and China. Our…
-
www.cibunigas.it
Innovation gets us there first Today the full compliance to emission standards is no longer sufficient to prevent the so called “greenhouse effect”. For this reason all our products have always granted a level of pollutant emissions well lower than those imposed by the international regulations.…
-
BURNER IDENTIFICATION FOR TYPE AND MODELS
SERIES TECNOPRESS NOVANTA CINQUECENTO MILLE DUEMILA TREMILA TYPE TP..., TLX..., TG..., TN..., TPBY…, HTP…, HTLX..., KTP…, KTPBY... M-. AB. S. GB. A. 1. 65. xx. xxx Model: FUEL M L B C G A - NATURAL GAS - L.P.G. - BIOGAS - TOWN GAS - LIGHT OIL - BIO DIESEL K - KEROSENE D - HEAVY OIL up to 400 cSt at…
-
EXAMPLE OF THE NEW RANGE CONFIGURATION
CIB UNIGAS S.P.A. Via L.Galvani, 9 35011 Campodarsego (PD) ITALIA TLX1030.1 Type Model M-.MD.S.GB.G.1.100.ES Year 2020 S. Number 2092020 El. Supply 400V 3N a.c. 50Hz El.Consump. 0,50 kW Fan Motor kW Protection IP54 Output 1550 -10700 kW Fuel NATURAL GAS Category I2H Gas pressure Max 500 mbar UNITED…
-
NATURAL GAS LOW NOx BURNERS (Class 3 EN676)
Type TLX TLX83 - TLX115 - TLX225 TLX92R - TLX92.1 TLX512R - TLX512.1 - TLX515.1 TLX520.1 - TLX525.1 TLX1030R - TLX1030.1 TLX2020 - TLX2030 - TLX2040 TLX3050 60 80 CLASS 3 Output kW Operation Page 200÷39.000 PR MD (electronic version) 28 7
-
DUAL FUEL BURNERS NATURAL GAS/LIGHT OIL LOW NOx (Classe 3 EN676)
60 80 CLASS 3 Type Output kW Operation Page HTLX HTLX83 - HTLX115 - HTLX225 HTLX92R - HTLX92.1 HTLX512R - HTLX512.1 - HTLX515.1 HTLX520.1 - HTLX525.1 HTLX1030R - HTLX1030.1 HTLX2020 - HTLX2030 - HTLX2040 HTLX3050 200÷39.000 PR MD (electronic version) 54 11
-
TECHNICAL INFORMATIONS
Page 1332 470.3 BURNERS DIMENSIONS 71 FITTINGS / OPTIONS 133 MICRO PROCESSOR CONTROLLED BURNERS WITH LMV 2... 3... MICROPROCESSOR for medium-large burners ELECTRONIC SUPERVISION AND CONTROL SYSTEM WITH LMV 5... for medium-large burners FLAME CONTROL UNITS, SIGNALS AND FUNCTIONS 135 SCOPE OF SUPPLY…
-
tecnopress novanta cinquecento
mille duemila tremila SERIES BURNERS FOR INDUSTRIAL APPLICATIONS WITH SEPARATE FAN These industrial burners have been designed for all those applications in which single block models are, for whatever reason, unsuitable. For example when the requested output requires the use of a too large built-in…
-
The burners can burn with different type of the gasses: Natural Gas, LPG, Biogas and Gas process
Options: - oxygen trim control (at the stack) with continuous system regulation; - VSD (inverter) trim control for the fan motor; - air combustion temperature up to 250°C; - modulating ratio up to 1:8, with moveable combustion head; - continuous ventilation; - remote control via bus protocol; - gas…
-
NATURAL GAS LOW NOx BURNERS
-
TLX TYPE TLX83 ... TLX3050
CLASS 3 GAS TLX3050 TLX2040 TLX2030 TLX2020 TLX1030.1 TLX1030R 2.000 3.000 4.000 5.000 6.000 7.000 8.000 9.000 10.000 11.000 12.000 13.000 14.000 15.000 16.000 17.000 18.000 19.000 20.000 21.000 22.000 23.000 24.000 25.000 26.000 27.000 28.000 29.000 30.000 31.000 Output (kW) TLX525.1 TLX520.1…
-
TLX83 ... TLX3050 TLX TYPE
-
TLX TYPE TLX83 ... TLX3050
-
TLX83 ... TLX3050 TLX TYPE
-
TLX TYPE TLX83 ... TLX3050
-
таблицы и схемы — в просмотре
-
TPBY TYPE TPBY90 ... TPBY3000
HEAVY OIL with viscosity up to 4000 cSt at 50°C (530°E at 50°C) - PNEUMATIC ATOMIZATION TPBY3000 TPBY2500 TPBY2000 TPBY1080 TPBY1050 TPBY1030 2.000 3.000 4.000 5.000 6.000 7.000 8.000 9.000 10.000 11.000 12.000 13.000 14.000 15.000 16.000 17.000 18.000 19.000 20.000 21.000 22.000 23.000 24.000…
-
TPBY90 ... TPBY3000 TPBY TYPE
-
TPBY... VS TYPE TPBY93 ... TPBY1080
HEAVY OIL with viscosity up to 4000 cSt at 50°C (530°E at 50°C) - PNEUMATIC ATOMIZATION TPBY1080 TPBY1030 1.000 2.000 3.000 4.000 5.000 6.000 7.000 8.000 9.000 10.000 11.000 12.000 13.000 14.000 15.000 16.000 17.000 18.000 19.000 9.500 10.000 10.500 Output (kW) TPBY525 TPBY515 TPBY93 500 1.000 1.500…
-
TPBY93 ... TPBY1080 TPBY... VS TYPE
-
DUAL FUEL BURNERS NATURAL GAS/LIGHT OIL LOW NOx
-
HTP TYPE HTP120A ... HTP3000
CLASS 2 GAS/LIGHT OIL HTP3000 HTP2500 HTP2000 HTP1080 HTP1050 HTP1030 2.000 3.000 4.000 5.000 6.000 7.000 8.000 9.000 10.000 11.000 12.000 13.000 14.000 15.000 16.000 17.000 18.000 19.000 20.000 21.000 22.000 23.000 24.000 25.000 26.000 27.000 28.000 29.000 30.000 31.000 39.000 Output (kW) HTP525A…
-
HTP120A ... HTP3000 HTP TYPE
-
HTP TYPE HTP120A ... HTP3000
GAS/LIGHT OIL Output (kW) Output (kW) Minimum inlet gas pressure (mbar) HTP205A PR-MD Output (kW) 48 HTP165A PR-MD Minimum inlet gas pressure (mbar) Minimum inlet gas pressure (mbar) HTP120A PR-MD
-
HTP120A ... HTP3000 HTP TYPE
-
HTP TYPE HTP120A ... HTP3000
GAS/LIGHT OIL HTP1030 PR-MD HTP1050 PR-MD 350 DN80 Minimum inlet gas pressure (mbar) Minimum inlet gas pressure (mbar) DN100 DN125 50 DN100 250 DN125 2000 300 3000 4000 5000 6000 7000 8000 0 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000 15000 16000 9000 10000 11000 12000 13000…
-
HTP90 ... HTP1080 HTP ...VS TYPE
CLASS 2 GAS/LIGHT OIL HTP1080 HTP1030 HTP525 HTP515 HTP93 HTP92 HTP91 HTP90 1.000 2.000 3.000 4.000 5.000 6.000 7.000 8.000 9.000 10.000 11.000 12.000 13.000 14.000 15.000 16.000 17.000 18.000 19.000 Output (kW) 51
-
HTP ...VS TYPE HTP90 ... HTP1080
-
HTP90 ... HTP1080 HTP ...VS TYPE
GAS/LIGHT OIL Rp 2" (50) DN65 DN80 DN100 HTP91 VS PR-MD Minimum inlet gas pressure (mbar) Minimum inlet gas pressure (mbar) HTP90 VS PR-MD Output (kW) Output (kW) HTP93 VS PR-MD Minimum inlet gas pressure (mbar) Minimum inlet gas pressure (mbar) HTP92 VS PR-MD Output (kW) Output (kW) HTP525 VS PR-MD…
-
HTLX TYPE HTLX83 ... HTLX3050
CLASS 3 GAS/LIGHT OIL HTLX3050 HTLX2040 HTLX2030 HTLX2020 HTLX1030.1 HTLX1030R 2.000 3.000 4.000 5.000 6.000 7.000 8.000 9.000 10.000 11.000 12.000 13.000 14.000 15.000 16.000 17.000 18.000 19.000 20.000 21.000 22.000 23.000 24.000 25.000 26.000 27.000 28.000 29.000 30.000 31.000 Output (kW)…
-
HTLX83 ... HTLX3050 HTLX TYPE
-
HTLX TYPE HTLX83 ... HTLX3050
-
HTLX83 ... HTLX3050 HTLX TYPE
-
HTLX TYPE HTLX83 ... HTLX3050
-
DUAL FUEL BURNERS NATURAL GAS/HEAVY OIL
-
KTP TYPE KTP90 ... KTP3000
GAS/HEAVY OIL with viscosity up to 400 cSt at 50°C (50°E at 50°C) - MECHANICAL ATOMIZATION KTP3000 KTP2500 KTP2000 KTP1080 KTP1050 KTP1030 2.000 3.000 4.000 5.000 6.000 7.000 8.000 9.000 10.000 11.000 12.000 13.000 14.000 15.000 16.000 17.000 18.000 19.000 20.000 21.000 22.000 23.000 24.000 25.000…
-
KTP90 ... KTP3000 KTP TYPE
-
KTP TYPE KTP90 ... KTP3000
-
KTP90 ... KTP3000 KTP TYPE
GAS/HEAVY OIL KTP1030 PR-MD KTP1050 PR-MD 350 Minimum inlet gas pressure (mbar) Minimum inlet gas pressure (mbar) 400 DN80 DN100 200 150 DN125 100 50 DN100 250 DN125 2000 300 3000 4000 5000 6000 7000 8000 0 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000 15000 16000 9000 10000 11000…
-
KTPBY TYPE KTPBY90 ... KTPBY3000
GAS/HEAVY OIL with viscosity up to 4000 cSt at 50°C (530°E at 50°C) - PNEUMATIC ATOMIZATION KTPBY3000 KTPBY2500 KTPBY2000 KTPBY1080 KTPBY1050 KTPBY1030 2.000 3.000 4.000 5.000 6.000 7.000 8.000 9.000 10.000 11.000 12.000 13.000 14.000 15.000 16.000 17.000 18.000 19.000 20.000 21.000 22.000 23.000…
-
KTPBY90 ... KTPBY3000 KTPBY TYPE
-
KTPBY TYPE KTPBY90 ... KTPBY3000
-
KTPBY90 ... KTPBY3000 KTPBY TYPE
GAS/HEAVY OIL KTPBY1030 PR-MD KTPBY1050 PR-MD 350 DN80 Minimum inlet gas pressure (mbar) Minimum inlet gas pressure (mbar) DN100 DN125 50 DN100 250 DN125 2000 300 3000 4000 5000 6000 7000 8000 0 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000 15000 16000 9000 10000 11000 12000 13000…
-
KTPBY... VS TYPE KTPBY93 ... KTPBY1080
GAS/HEAVY OIL with viscosity up to 4000 cSt at 50°C (530°E at 50°C) - PNEUMATIC ATOMIZATION KTPBY1080 KTPBY1030 1.000 2.000 3.000 4.000 5.000 6.000 7.000 8.000 9.000 10.000 11.000 12.000 13.000 14.000 15.000 16.000 17.000 18.000 19.000 9.500 10.000 10.500 Output (kW) KTPBY525 KTPBY515 KTPBY93 500…
-
KTPBY93 ... KTPBY1080 KTPBY... VS TYPE
-
KTPBY... VS TYPE KTPBY93 ... KTPBY1080
GAS/HEAVY OIL with viscosity up to 4000 cSt at 50°C (530°E at 50°C) - PNEUMATIC ATOMIZATION KTPBY515 VS PR-MD Minimum inlet gas pressure (mbar) Minimum inlet gas pressure (mbar) KTPBY93 VS PR-MD 1500 2500 3500 4500 1500 2500 Output (kW) 3500 Minimum inlet gas pressure (mbar) Minimum inlet gas…
-
BURNERS DIMENSIONS
-
TP3000 TP TYPE
-
TLX83 TLX115 TLX225 TLX TLX...FGR TYPE
-
TLX TLX...FGR TYPE TLX92R TLX92.1
-
TLX512R TLX512.1 TLX515.1 TLX TLX...FGR TYPE
-
TLX TLX...FGR TYPE TLX1030R TLX1030.1
-
TLX2020 TLX2030 TLX2040 TLX TLX...FGR TYPE
-
TLX TLX...FGR TYPE TLX3050
-
TG3000 TG TYPE
-
TN TYPE TN3000
-
TPBY90 TPBY91 TPBY92 TPBY93 TPBY TYPE
-
TPBY TYPE TPBY510 TPBY515 TPBY520 TPBY525
-
TPBY1030 TPBY1050 TPBY1080 TPBY TYPE
-
TPBY TYPE TPBY2000 TPBY2500
-
TPBY... VS TYPE TPBY93
-
TPBY515 TPBY525 TPBY... VS TYPE
-
OVERALL DIMENSIONS
-
HTP120A HTP165A HTP205A HTP TYPE
-
HTP TYPE HTP90A HTP91A HTP92A HTP93A
-
HTP512A HTP515A HTP520A HTP525A HTP TYPE
-
HTP TYPE HTP1030 HTP1050 HTP1080
-
HTP2000 HTP2500 HTP TYPE
-
HTP TYPE HTP3000
-
HTP90 HTP91 HTP92 HTP93 HTP... VS TYPE
-
HTP... VS TYPE HTP515 HTP525
-
HTP1030 HTP1080 HTP... VS TYPE
-
HTLX HTLX...FGR TYPE HTLX83 HTLX115 HTLX225
-
HTLX92R HTLX92.1 HTLX HTLX...FGR TYPE
-
HTLX HTLX...FGR TYPE HTLX512R HTLX512.1 HTLX515.1
-
HTLX1030R HTLX1030.1 HTLX HTLX...FGR TYPE
-
HTLX HTLX...FGR TYPE HTLX2020 HTLX2030
-
HTLX3050 HTLX HTLX...FGR TYPE
-
KTP TYPE KTP90 KTP91 KTP92 KTP93
-
KTP512 KTP515 KTP520 KTP525 KTP TYPE
-
KTP TYPE KTP1030 KTP1050 KTP1080
-
KTP2000 KTP2500 KTP TYPE
-
KTP TYPE KTP3000
-
OVERALL DIMENSIONS
-
KTPBY3000 KTPBY TYPE
-
KTPBY... VS TYPE KTPBY93
-
KTPBY515 KTPBY525 KTPBY...VS TYPE
-
KTPBY... VS TYPE KTPBY1030 KTPBY1080
-
FITTINGS / OPTIONS
-
MICRO PROCESSOR CONTROLLED BURNERS
WITH LMV 2... MICRO PROCESSOR EA Medium-large burners complete with electronic cam EB Medium-large burners complete with electronic cam and inverter EC Medium-large dual fuel burners complete with electronic cam ED Medium-large dual fuel burners complete with electronic cam and inverter WITH LMV…
-
WITH LMV 2... 3... MICROPROCESSOR
for medium-large burners CIB UNIGAS S.p.A. can provide medium size burners (up to 15.200 kW), with an electronic control system. It can be used both on single fuel burners (gas or light oil), and on dual fuel burners (gas/light oil). This system offers the following features: • Reduction of…
-
WITH LMV 2... 3... MICROPROCESSOR
for medium-large burners 138 Model Series Fuel LMV 20 EA TECNOPRESS NOVANTA CINQUECENTO gas ● EA MILLE DUEMILA gas EA TECNOPRESS NOVANTA CINQUECENTO liquid fuel EA MILLE DUEMILA liquid fuel EB TECNOPRESS NOVANTA CINQUECENTO gas ● EB MILLE DUEMILA gas ● EB TECNOPRESS NOVANTA CINQUECENTO liquid fuel ●…
-
AZL 23
SQM33 air SQM33 gas SQM33 liquid fuel ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● INVERTER 139
-
ELECTRONIC SUPERVISION
AND CONTROL SYSTEM WITH LMV 5... for medium-large burners CIB UNIGAS S.p.A has provided its burners with an electronic system of adjustment and control. This innovative system, divided into two types of devices, can be used for both civil and industrial applications (up to 39 MW), and for burners…
-
ELECTRONIC SUPERVISION
AND CONTROL SYSTEM WITH LMV 5... for medium-large burners Model ES ES ES EO EO EI EI EI EK EK EF EF EG EG EP EP ER ER Series TECNOPRESS - NOVANTA CINQUECENTO - MILLE DUEMILA - TREMILA TECNOPRESS - NOVANTA CINQUECENTO - MILLE DUEMILA - TREMILA TECNOPRESS - NOVANTA CINQUECENTO - MILLE DUEMILA…
-
AZL 5x
SQM4x air SQM4x gas ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● SQM4x liquid fuel SQM4x FGR O2 PROBE FGR PROBE INVERTER ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●* ● ● ●* ● ● ●* ● ● ● ●* ● ● 143
-
FLAME CONTROL UNITS, SIGNALS AND FUNCTIONS
Progressive burners can be controlled by a 3-points signal (high/low flame) through the appropriate terminals. However, depending on the type of application and automation of the boiler, other types of signal can also be used, both at burner input (analogue modulation), and at the output (feedback…
-
Some functions are present on standard CIB Unigas burners, others may be requested during quotation phase and will require, as a result, modifications to standard products (such as adding a signal converter at the input or output terminals). The following is a table list of available configurations…
-
SCOPE OF SUPPLY
The specifications for the standard equipment included in the burners can be found on the following pages. More detailed information can be found in the operating instruction manual. GAS BURNERS LIQUID FUEL BURNERS Pag. 147- 148 - 149 - 150 Pag. 219 - 220 - 224 - 225 - 226 - 227 Dual fuel burners…
-
GAS BURNERS
The gas and LPG burners include as standard supply: filter, ball manual valve (optional), pressure regulator, minimum gas pressure switch, butterfly valve. On customer’s request the maximum gas pressure switch and the tightness control function, pressure gauges (with ball valve), anti-vibration…
-
GAS TRAINS MB-DLE
MANUFACTURER INSTALLER Gas train with valves group MB-DLE (2 valves + gas filter + pressure governor). Gas train with valves group MB-DLE (2 valves + gas filter + pressure governor) + leakage control VPS504. Gas train with valves group MB-DLE (2 valves + gas filter + pressure governor) + leakage…
-
GAS TRAINS SIEMENS VGD
MANUFACTURER INSTALLER Gas train with valve group VGD, c/w built-in pressure governor + leakage control pressure switch. Gas train with valve group VGD, c/w built-in pressure governor + leakage control pressure switch. Pilot train with double valve and filter/governor. Pilot train with double valve…
-
GAS TRAINS DUNGS MBE
MANUFACTURER Gas train with valve group MBE, c/w built-in pressure governor + leakage control pressure switch + max pressure switch. MBE Gas train with valve group MBE, c/w built-in pressure governor + leakage control pressure switch + max pressure switch. Pilot train with double valve and…
-
PRESSURE REDUCTION GROUPS
The standard burners are equipped with a gas train, with two safety valves, governor, filter and a pressure switch. The inlet pressure limits for the standard gas trains are shown in the table at page 147. For higher pressures up to 6 bar, pressure reducing units are available. The variants are…
-
NATURAL/LPG IGNITION BURNERS
The following burner models are equipped with pilot burner: - 1000 series, single-head - 90 / 500 series oil (single-head) - Low-emission NOx burners, size 2000 and upwards The following models are equipped with ignition electrodes: - VS type burners (all) - 90 / 500 series, gas and diesel…
-
LIGHT OIL PILOT BURNERS
Upon customer’s request it is possible to supply a light oil pilot burner instead of a gas burner. In this case the supply includes the components described below. Fig. 01 Ligth oil inlet Return to the tank LEGEND Light oil pilot burner Light oil fuel hose Electrical valve Pump and motor Manometer…
-
REVERSIBLE GAS TRAIN
During the installation phase of the burner, the gas train can be installed either on the right or on the left side by simply turn the flanged connection in the desired direction. The installation can be completed with anti-vibration joint, manual ball valves and other options. All sizes (series 90…
-
BURNERS OPERATING
WITH COMBUSTION AIR HIGH TEMPERATURE Some processes or industrial applications require the use of hot combustion air, mainly for the purpose of saving fuel and improving the efficiency of the boiler plant. Burners with a separate fan and electrical panel, with appropriate modifications, can be used…
-
BURNER HEAD ORIENTATION
Burners of this type are supplied with separate fans. The delivery includes motorised air damper with actuator, and a corrugated flange connecting the burner to air duct. The duct and fan can be positioned according to the design, taking into account the specifications and limits of the location.…
-
Air inlet
C Flange to be connected into the air duct B D A The desired orientation must be specified when ordering: example HTP1030A burner with combustion air inlet from above, position C 157
-
BURNER HEAD ORIENTATION
C B D A The desired orientation must be specified when ordering: example TLX2020 burner with combustion air inlet from above, position C. 158
-
BURNER AMBIENT AIR FROM BELOW
B LEGEND 1 Boiler 2 Burner 3 Fan ventilator 4 Cold combustion air regulation damper B Ambient air 159
-
BURNER AMBIENT AIR FROM ABOVE
3 1 B B LEGEND 1 Boiler 2 Burner 160 3 Fan ventilator 4 Cold combustion air regulation damper B Ambient air
-
B BURNER HOT AIR FROM BELOW C B B C LEGEND 1 Boiler 2 Burner 3 Fan ventilator 4 Cold combustion air regulation damper 9 Economizer B Ambient air C Heated air 161
-
BURNER HOT AIR FROM ABOVE
3 9 C B C B LEGEND 1 Boiler 2 Burner 3 Fan ventilator 162 4 Cold combustion air regulation damper 9 Economizer B Ambient air C Heated air
-
BURNER AMBIENT AIR WITH FGR
A B B A LEGEND 1 Boiler 2 Burner 3 Fan ventilator 4 Cold combustion air regulation damper 5 Differential pressure switch 6 Condensate drain 7 FGR regulation damper 8 FGR temperature probe A Flue gas recirculation B Ambient air 163
-
BURNER HOT AIR FROM ABOVE WITH FGR BEFORE THE ECONOMIZER
Used when the smoke temperature is < 200 °C before economizer B C 4 9 B 3 C A 2 LEGEND 1 Boiler 2 Burner 3 Fan ventilator 164 4 Cold combustion air regulation damper 5 Differential pressure switch 6 Condensate drain 7 FGR regulation damper 8 FGR temperature probe 9 Economizer A Flue gas…
-
BURNER HOT AIR FROM ABOVE WITH FGR AFTER THE ECONOMIZER
Used when the smoke temperature is > 200 °C before economizer B A C 5 1 B 4 2 LEGEND 1 Boiler 2 Burner 3 Fan ventilator 4 Cold combustion air regulation damper 5 Differential pressure switch 6 Condensate drain 7 FGR regulation damper 8 FGR temperature probe 9 Economizer A Flue gas recirculation B…
-
FACILE SYSTEM
THE FIRST BURNER WITH SELF REGULATION The FACILE can also be applied to duo bloc burners by assembling the components as shown in the drawing. 3 4 OVERTURNING THE PERSPECTIVE IS FACILE 1 The FACILE ” project stems from the vision 2 of creating an easy commissioning burner, and, at the same time…
-
THERE IS A TECHNICIAN BUT YOU CAN’T SEE HIM
The main feature of the system is that it does not need the setting of the burner on plant, and therefore it skips the (sometimes) laborious and expensive commissioning operated by a qualified technician. The fuel curves of the burner are automatically created by the system in the initial start-up…
-
ADJUSTMENT OF THE BURNERS
When choosing the burner, the customer may select one among the following configurations. TN (single-stage) Burners with single-stage regulation operate in ON-OFF configuration: when an external switch (e.g. the boiler regulation thermostat) closes, the burner is switched on, and then operates at…
-
Control range and modulating ratio of a burner
Each burner, whether with an on-board or separate fan, is characterized by its performance curve defined by the minimum and maximum output within which it can operate. The modulating ratio is defined as the actual ratio between the minimum and maximum output of a specific thermal group burner-boiler…
-
ADJUSTMENT OF THE BURNERS
Burners with high modulating ratio A special high modulating ratio customization is available on Class 2 gas and dual fuel burners with electronic control (variants with LMV51/52 units). This configuration can guarantee a ratio 1:6 between minimum and maximum power (1:10 with inverter). This…
-
HOW TO CHOOSE A BURNER
How to choose a duo-bloc burner at sea level and at altitude To ensure a complete and safe combustion, the burner must be supplied with the correct flow of oxygen. The amount of oxygen available is proportional to the density of the combustion air, and the density depends on the environmental…
-
HOW TO CHOOSE A BURNER
Back pressure in combustion chamber [mbar] To ensure a complete and safe combustion, the burner must be supplied with the correct flow of oxygen. The amount of oxygen available is proportional to the density of the combustion air, and the density depends on the environmental conditions. 20 15…
-
This value must be adjusted according to the following
1. temperature of combustion air (standard 20 °C - table for different temperature); 2. sea level (refer to the table for correction factors); 3. air loss of the connecting pipes between burner head and ventilator (estimated to 5 %). Example at 100 mt sea level: Results will be the following for an…
-
EMISSIONS
The subject of emissions is very wide and complex. The scientific literature in this field is under continuous update and there’s no way to describe it briefly. The boiler room is a source of pollution caused by the combustion of hydrocarbons. Combustion products consist mainly of nitrogen, carbon…
-
CIB UNIGAS burners, NOx emissions
- Low NOx gas burners correspond to Class 2, Ultra Low NOx burners without FGR correspond to Class 3. - LPG burners correspond to Class 1, Low NOx LPG burners correspond to Class 3; - Oil burners have a maximum NOx emission of 250 mg/kWh (Class 1); - Heavy fuel oil burners (non-standard fuel oil)…
-
LOW NOX BURNERS - TECHNICAL NOTES
WHY DIFFERENT THERMAL GROUPS RELEASE DIFFERENT LEVELS OF NITROGEN OXIDES AT THE SAME OUTPUT? The CO, NOx and other pollutants are strongly influenced by a number of factors, not always burner related. There are factors independent from the thermal plant, such as environmental conditions (altitude…
-
WHY CHOOSE CIB UNIGAS
Relation between NOx emissions and CO CO NOx [ppm] 110 Emissions of nitrogen oxides and carbon m o n ox i d e a r e s t r o n g l y c o r r e l a te d a s both depend on the stoichiometry of the combustion. Excess of air affects both emissions and the efficiency of the generator. In a logic of…
-
INTRODUCTION
To choose any burner, the following data are mandatory: • Boiler type • Burner input • Backpressure in the combustion chamber • Dimensions of the combustion chamber included the reverse smoke chamber • NOx emissions requested, 80, 50, 30 mg/kWh The procedure is divided into three steps: • choosing…
-
Increase of NOx according to the variation of comburent air temperature
10 9 Increase [%] Reference conditions • Measurement tolerances according to EN 676 standard • Temperature: 20 °C • Dried flue gases • Barometric pressure: 1013 millibars • Relative humidity: 70 % (equivalent to 10 g H2O/kg of air) • Boiler temperature: 110 °C • Fuel: G20 (natural gas, 100 % CH4) •…
-
BURNER SELECTION FOR NOx < 50 mg/kWh and < 30 mg/kWh
With NOx < 50 mg/kWh and < 30 mg/kWh we need to have a smoke recirculation (FGR). The smoke recirculation decreases a percentage of the performance curves and increases the backpressure in the combustion chamber. This percentage depend also of the thermal load of the combustion chamber. In order to…
-
SELECTION 1: TLX525.1...FGR
SELECTION 2: TLX1030.1...FGR Burner max capacity with 50 mg/kWh Burner max capacity with 30 mg/kWh Burner max capacity with 50 mg/kWh Burner max capacity with 30 mg/kWh mg/kWh 16 50 mg/kWh Combustion chamber backpressure [mbar] Combustion chamber backpressure [mbar] mg/kWh 16 50 mg/kWh 1000 1500…
-
OUTPUT REDUCTION IN REFERENCE TO THE BURNER PERFORMANCE CURVE
TLX83 HTLX83 90 80 NOx [mg/kWh] * TLX83 FGR Power reduction in reference to the burner performance curve [%] 0,4 0,6 0,8 1,0 1,2 1,4 1,6 NOx 30 mg/kWh NOx 50 mg/kWh 5 0 0,4 1,8 0,6 0,8 Thermal load [MW/m3] TLX115 HTLX115 Power reduction in reference to the burner performance curve [%] 90 NOx…
-
OUTPUT REDUCTION IN REFERENCE TO THE BURNER PERFORMANCE CURVE
TLX92R HTLX92R 90 80 NOx [mg/kWh] * TLX92R FGR Power reduction in reference to the burner performance curve [%] 0,4 0,6 0,8 1,0 1,2 1,4 1,6 25 20 NOx 30 mg/kWh 15 10 NOx 50 mg/kWh 5 0 0,4 1,8 0,6 0,8 Thermal load [MW/m3] TLX92.1 HTLX92.1 NOx [mg/kWh] * 0,8 1,0 1,2 1,4 1,6 NOx 30 mg/kWh NOx 50 mg/kWh…
-
OUTPUT REDUCTION IN REFERENCE TO THE BURNER PERFORMANCE CURVE
TLX512.1 HTLX512.1 90 80 NOx [mg/kWh] * TLX512.1 FGR HTLX512.1 FGR Power reduction in reference to the burner performance curve [%] 0,4 0,6 0,8 1,0 1,2 1,4 1,6 30 NOx 30 mg/kWh 25 20 NOx 50 mg/kWh 0,4 1,8 0,6 0,8 Thermal load [MW/m3] 1,0 TLX515.1 HTLX515.1 90 NOx [mg/kWh] * 0,6 0,8 1,0 1,2 1,4 1,6…
-
TLX525.1
OUTPUT REDUCTION IN REFERENCE TO THE BURNER PERFORMANCE CURVE HTLX525.1 90 80 NOx [mg/kWh] * TLX525.1 FGR Power reduction in reference to the burner performance curve [%] 0,4 0,6 0,8 1,0 1,2 1,4 1,6 NOx 30 mg/kWh 25 20 NOx 50 mg/kWh 0,4 1,8 0,6 0,8 Thermal load [MW/m3] TLX1030R HTLX1030R NOx…
-
OUTPUT REDUCTION IN REFERENCE TO THE BURNER PERFORMANCE CURVE
TLX2020 TLX2030 TLX2040 TLX3050 TLX2020 FGR TLX2030 FGR TLX2040 FGR TLX3050 FGR HTLX2020 HTLX2030 HTLX2040 HTLX3050 HTLX2020 FGR HTLX2030 FGR HTLX2040 FGR HTLX3050 FGR Power reduction in reference to the burner performance curve [%] 100 90 NOx [mg/kWh] * 80 70 Contact our Sales Offices 0,4 0,6 0,8…
-
FANS AND ACOUSTIC HOODS BOX FAN COVERS
Delivery condition - Fans: packing INCLUDED - Acoustic hoods box fan covers: Packing INC. - Fan hoods in special design with orientation LG/RD 180/225: Price quotation upon request - Anti-vibration coupling at fan delivery: INCLUDED - Packaging is included in the delivery (the packages consist of…
-
TP TYPE
-
таблицы и схемы — в просмотре
-
TP...VS TYPE
-
60 80 CLASS 3 TLX - TLX...FGR TYPE 30 16 TLX83 TLX115 25 Pressure at the head (mbar) Pressure at the head (mbar) Output (kW) 1000 1100 1200 1300 Output (kW) 30 TLX225 Pressure at the head (mbar) 1000 1500 2000 2500 3000 Output (kW) 30 40 TLX92R TLX92.1 35 Pressure at the head (mbar) Pressure at the…
-
60 80 CLASS 3 TLX - TLX...FGR TYPE 80 45 TLX1030R TLX1030.1 70 35 Pressure at the head (mbar) Pressure at the head (mbar) 1000 2000 3000 4000 5000 6000 7000 8000 9000 0 10000 2000 4000 6000 Output (kW) 90 Pressure at the head (mbar) Pressure at the head (mbar) 14000 2000 4000 6000 8000 10000 12000…
-
TG TYPE
12 12 TG90 TG91 10 Pressure at the head (mbar) Pressure at the head (mbar) 1000 1500 2000 0 2500 500 1000 Output (kW) 1500 2000 2500 3000 Output (kW) 30 12 Pressure at the head (mbar) TG92 1000 1500 2000 2500 3000 0 3500 500 1000 1500 2000 2500 3000 3500 4000 4500 Output (kW) 16 16 TG510 TG515 14…
-
TG TYPE
40 50 TG1030 45 TG1050 35 Pressure at the head (mbar) Pressure at the head (mbar) 2000 4000 6000 8000 10000 12000 14000 16000 0 2000 4000 6000 8000 Output (kW) 10000 12000 14000 16000 18000 Output (kW) 50 TG1080 45 Pressure at the head (mbar) 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000…
-
TN TYPE
12 12 TN90 TN91 10 Pressure at the head (mbar) Pressure at the head (mbar) 1000 1500 2000 0 2500 500 1000 Output (kW) 1500 2000 2500 3000 Output (kW) 30 12 Pressure at the head (mbar) TN92 1000 1500 2000 2500 3000 0 3500 500 1000 1500 2000 2500 3000 3500 4000 4500 Output (kW) 16 16 TN510 TN515 14…
-
TN TYPE
40 50 TN1030 45 TN1050 35 Pressure at the head (mbar) Pressure at the head (mbar) 2000 4000 6000 8000 10000 12000 14000 16000 0 2000 4000 6000 8000 Output (kW) 10000 12000 14000 16000 18000 Output (kW) 50 TN1080 45 Pressure at the head (mbar) 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000…
-
TPBY TYPE
12 12 TPBY90 TPBY91 10 Pressure at the head (mbar) Pressure at the head (mbar) 1000 1500 2000 0 2500 500 1000 1500 Output (kW) TPBY92 TPBY93 Pressure at the head (mbar) Pressure at the head (mbar) 3000 1000 1500 2000 2500 3000 0 3500 500 1000 1500 Output (kW) 2000 2500 3000 3500 4000 4500 Output…
-
TPBY TYPE
40 50 TPBY1030 45 TPBY1050 35 Pressure at the head (mbar) Pressure at the head (mbar) 2000 4000 6000 8000 10000 12000 14000 16000 0 2000 4000 6000 8000 Output (kW) 10000 12000 14000 16000 18000 Output (kW) 50 TPBY1080 45 Pressure at the head (mbar) 2000 4000 6000 8000 10000 12000 14000 16000 18000…
-
TPBY...VS TYPE
30 TPBY93...VS Pressure at the head (mbar) 1000 1500 2000 2500 3000 3500 4000 4500 Output (kW) 16 25 TPBY515...VS TPBY525...VS 20 12 Pressure at the head (mbar) Pressure at the head (mbar) 1000 2000 3000 4000 5000 6000 0 2000 4000 6000 Output (kW) 10000 12000 50 50 TPBY1030...VS 45 TPBY1080...VS 45…
-
HTP TYPE
12 18 HTP120A HTP165A 16 Pressure at the head (mbar) Pressure at the head (mbar) 1000 1200 1400 Output (kW) 800 1000 1200 1400 1600 1800 Output (kW) 9 HTP205A 8 Pressure at the head (mbar) 1000 1500 2000 2500 Output (kW) 12 12 HTP90A HTP91A 10 Pressure at the head (mbar) Pressure at the head (mbar)…
-
HTP TYPE
16 16 HTP512A HTP515A 14 Pressure at the head (mbar) Pressure at the head (mbar) 1000 1500 2000 2500 3000 3500 4000 4500 0 5000 1000 2000 3000 Output (kW) 20 5000 6000 8000 10000 12000 25 HTP520A 18 HTP525A 20 Pressure at the head (mbar) 16 Pressure at the head (mbar) 4000 Output (kW) 1000 2000 3000…
-
HTP...VS TYPE
12 12 HTP90...VS HTP91...VS 10 Pressure at the head (mbar) Pressure at the head (mbar) 1000 1500 2000 0 2500 500 1000 1500 Output (kW) HTP92...VS HTP93...VS Pressure at the head (mbar) Pressure at the head (mbar) 3000 1000 1500 2000 2500 3000 0 3500 500 1000 1500 2000 Output (kW) 2500 3000 3500 4000…
-
60 80 CLASS 3 HLX - HTLX...FGR TYPE 30 16 HTLX83 HTLX115 25 Pressure at the head (mbar) Pressure at the head (mbar) Output (kW) 1000 1100 1200 1300 Output (kW) 20 HTLX225 18 Pressure at the head (mbar) 1000 1500 2000 2500 Output (kW) 30 40 HTLX92R HTLX92.1 35 Pressure at the head (mbar) Pressure at…
-
60 80 CLASS 3 HLX - HTLX...FGR TYPE 80 45 HTLX1030R 40 HTLX1030.1 70 Pressure at the head (mbar) Pressure at the head (mbar) 1000 2000 3000 4000 5000 6000 7000 8000 9000 0 10000 2000 4000 6000 Output (kW) 90 Pressure at the head (mbar) Pressure at the head (mbar) 14000 2000 4000 6000 8000 10000…
-
KTP TYPE
12 12 KTP90 KTP91 10 Pressure at the head (mbar) Pressure at the head (mbar) 1000 1500 2000 0 2500 500 1000 1500 Output (kW) KTP92 KTP93 Pressure at the head (mbar) Pressure at the head (mbar) 3000 1000 1500 2000 2500 3000 0 3500 500 1000 1500 Output (kW) 2000 2500 3000 3500 4000 4500 Output (kW) 16…
-
KTPY TYPE
40 50 KTP1030 45 KTP1050 35 Pressure at the head (mbar) Pressure at the head (mbar) 2000 4000 6000 8000 10000 12000 14000 16000 0 2000 4000 6000 8000 Output (kW) 10000 12000 14000 16000 18000 Output (kW) 50 KTP1080 45 Pressure at the head (mbar) 2000 4000 6000 8000 10000 12000 14000 16000 18000…
-
KTPBY TYPE
12 12 KTPBY90 KTPBY91 10 Pressure at the head (mbar) Pressure at the head (mbar) 1000 1500 2000 0 2500 500 1000 1500 Output (kW) KTPBY92 KTPBY93 Pressure at the head (mbar) Pressure at the head (mbar) 3000 1000 1500 2000 2500 3000 0 3500 500 1000 1500 Output (kW) 2000 2500 3000 3500 4000 4500 Output…
-
KTPBY TYPE
40 50 KTPBY1030 45 KTPBY1050 35 Pressure at the head (mbar) Pressure at the head (mbar) 2000 4000 6000 8000 10000 12000 14000 16000 0 2000 4000 6000 8000 Output (kW) 10000 12000 14000 16000 18000 Output (kW) 50 KTPBY1080 45 Pressure at the head (mbar) 2000 4000 6000 8000 10000 12000 14000 16000…
-
KTPBY...VS TYPE
30 KTPBY93...VS Pressure at the head (mbar) 1000 1500 2000 2500 3000 3500 4000 4500 Output (kW) 25 16 KTPBY525...VS KTPBY515...VS 14 12 Pressure at the head (mbar) Pressure at the head (mbar) 1000 2000 3000 4000 5000 0 6000 2000 4000 6000 Output (kW) 10000 12000 50 50 KTPBY1030...VS 45…
-
SULFUR OXIDES EMISSIONS
The polluting emissions of sulphur oxides (SOx) mainly include sulphur dioxide (SO2) and trioxide (SO3). These chemicals are particularly aggressive and dangerous, both for the environment and human health. However, sulphur oxides represent a separate case from CO and NO x since their production…
-
CIB UNIGAS burners can be operated with a wide range of liquid and gaseous fuels. The first two letters in the burner model indicate the type or types of fuel/s used: Type: Example TP... TLX... TG... TN... TPBY... HTP... HTLX... KTP... KTPBY... Model: M- . XX. X . XX The main fuels are: Gases…
-
GAS BURNERS
Gas burners can be operated with different gas types, burner regulation and valves. Combustion head and other components may vary depending on the selected type of fuel. When ordering, it is necessary to specify the selected fuel; check the price list for the extra charge of the required variants.…
-
In order to facilitate the selection of the optimum configuration, it is advisable to send the fuel analysis to our TECHNOLOGY INFORMATIONS. The following basic parameters require clarification: - Gas or mixture composition - Density under standard conditions - Lower heating value - Alternatively…
-
Heavy oils are used in a wide range of applications, e.g. in oil extraction and refinery plants
Heavy oil is relatively cheap compared to other refined hydrocarbons, however it requires a number of treatments before it can be pumped and burnt in traditional boiler plant. Correct operation of a burner depends entirely on the availability of the following devices and the execution of the…
-
Also, in the case of oil burners, at the ordering stage, it is recommended to provide fuel analyses to our Technical Department. This applies especially to crude oil and other heavy fuels with variable composition. The main parameters that need to be clarified are: - the composition of the liquid…
-
HEAVY OIL HEATING
The TN, KTP, TPBY and KTPBY burner series are designed for heavy oil that can be used both as the main fuel, and as a reserve fuel. The heavy oil must be supplied to the burner at a temperature sufficient for atomisation at the nozzle (example: 120÷130 °C). The higher the viscosity of the fuel, the…
-
Fig. 02 - Heavy oil preheating station (example with 3 parallel heat exchangers)
COMPRESSED AIR TEMPERATURE CONTROL HEAVY OIL SUPPLY (TO THE BURNER) STEAM INLET HEAVY OIL INPUT CONDENSATE DISCHARGE COMPONENTS ASSEMBLED ON A FREESTANDING FRAME LEGEND 1 Air regulator 7 Ball valve (steam) 2 Thermostat 8 Condensation chamber 3 Manual ball valve 9 Flow indicator 4 Filter (steam) 10…
-
HEAVY OIL HEATING
In addition to the exchangers shown on the previous pages, it is possible to provide fuel storage tanks. The heavy storage tanks can also be equipped with water coils, steam coils or electrical heaters. These tanks are designed for low pressure ring heavy oil circuits. 218
-
The light oil burners are equipped with a lance with nozzle. The nozzle operates with mechanical atomisation of fuel at high pressure (25 bar). Delivery includes filter, pump, regulator, safety valves, minimum pressure switch, pressure gauge. The pump can be driven by a fan motor or a separate…
-
Fig. 01 - Light oil unit of TG, HTP VS series (output < 3 MW)
COMPONENTS INTEGRATED INTO THE BURNER LIGHT OIL UNIT, FACTORY-ASSEMBLED ON THE FRAME Light oil return Light oil inlet Fig. 02 - Light oil unit of TG, HTP VS series (output ≥ 3 MW) COMPONENTS INTEGRATED INTO THE BURNER LIGHT OIL UNIT, FACTORY-ASSEMBLED ON THE FRAME Light oil return Light oil inlet…
-
BURNERS WITH FREE-STANDING LIGHT OIL
LIGHT OIL UNIT - Maximum dimensions of pump and fuel group B H A Burner size Pump motor A H B up to 520 < 4 kW 790 mm 600 mm 620 mm from 525 ≥ 4 kW 990 mm 700 mm 670 mm CIB Unigas light oil burners are also suitable for fuels that are not widely used, such as: arctic diesel, paraffin, gas…
-
Heavy oil burners are divided into two main categories
TN, KTP series These models are equipped with a lance and by-pass nozzle. The nozzle works with mechanical spraying at high pressure (25 bar). Delivery includes filter, pump, regulator, valves, thermostats. One or two fuel preheater tanks, fitted with electrical resistors, can be found aboard the…
-
Fig. 01 - Scheme for heavy fuel oil: example with TN, KTP series single-head burners
35 Heavy oil return Heavy oil inlet LEGEND 1 Oil filter 18 Electro-valve 2 Pump and motor 19 Minimal pressure switch 3 Heavy oil hose 20 Check valve 4 Manometer ball valve (option) 21 Flow regulator 5 Manometer (option) 22 Manometer ball valve 6 Safety valve 23 Manometer 7 Manual ball valve 24 Hose…
-
BURNERS WITH FREE-STANDING HEAVY OIL
Burners with separate heavy oil (series TPBY, KTPBY) are equipped with lance and nozzle for pneumatic atomization of fuel. Atomisation of fuel is carried out with compressed air or alternatively with steam (optional). Delivery includes valves and fuel preheating tanks integrated into the burner…
-
Fig. 02 - Heavy oil for TPBY, KTPBY VS series burners (output < 10 MW)
COMPONENTS INTEGRATED INTO THE BURNER OPTION Steam inlet Steam return Compressed air inlet Heavy oil inlet Heavy oil return Fig. 03 - Heavy oil for TPBY, KTPBY series burners, single-head burners (output ≥ 10 MW) COMPONENTS INTEGRATED INTO THE BURNER OPTION Steam inlet Steam return Compressed air…
-
BURNERS WITH FREE-STANDING HEAVY OIL
Fig. 04 - Heavy oil for TPBY, KTPBY VS series burners (output ≥ 10 MW) COMPONENTS INTEGRATED INTO THE BURNER OPTION Steam inlet Steam return Compressed air inlet Heavy oil inlet Heavy oil return LEGEND Oil filter Pump and motor Fuel oil hose Manometer holder cock Manometer Safety valve Manual cock…
-
OIL BURNERS
The standard scope of supply of oil burners include two flexible low-pressure hoses, filter, (supplied separately), pump, nozzle and combustion head, flow pressure regulator and shut-off valves. The pressure gauges and other accessories can be ordered separately upon customer’s request. This table…
-
LOW PRESSURE OIL HANDLING UNITS
WITH SERVICE TANK Very often, for a correct light and heavy oil burners operation, it is necessary to prepare an additional fuel supply line. In this case, rather than sucking the fuel from the tank through separate pipes suitable to each individual burner, a lowpressure supply circuit (normally 1 ÷…
-
FLAME CONTROL SENSORS
In order to ensure a safe ignition, the technical regulations require that all burners are provided with a flame detection sensor. The sensor sends a signal to the electronic flame control unit and if it fails, the control box immediately shutoff the valves, and stop burner operation. This is…
-
SEPARATE ELECTRICAL PANELS FOR BURNERS
Standard burners are provided with integrated electrical panels which include all electronic automation and all necessary components for a correct and reliable operation. Alternative solutions to the integrated control panel are available upon request: - Wall mounted control panel according to…
-
COMPRESSORS FOR BURNERS WITH PNEUMATIC ATOMISATION
- Consider the data on the table here below as a guide to select a suitable compressor in case air is to be used for the atomisation of heavy fuel oil. - The compressor can be supplied separately from the burner, compressors are out of our standard scope of supply. - The air parameters are taken at…
-
COMPRESSORS FOR BURNERS WITH PNEUMATIC ATOMISATION
Burner type 232 Power Air/steam flow rate Pressure [kW] [kg/h] [St l/s] [bar] KTPBY90 2.300 24,7 5,5 6÷8 KTPBY91 2.670 28,6 6,3 6÷8 KTPBY92 3.050 32,7 7,2 6÷8 KTPBY93 4.100 44,0 9,7 6÷8 KTPBY512 4.500 48,3 10,7 6÷8 KTPBY515 5.200 55,8 12,4 6÷8 KTPBY520 6.400 68,7 15,2 6÷8 KTPBY525 9.750 104,7 23,3…
-
ACCESSORIES
Accessories for gas, light oil or heavy fuel oil can be ordered together with the burners (see from pag. 236 to 244). These accessories include: - Modulation probe - Spacer parts for fitring head - Counter-flanges - Leakage control - Max. gas pressure switches - Gas pressure regulators - Regulators…
-
COUNTERFLANGE SELECTION
The length of burner firing head is selected according to the rules laid down by the boiler manufacturers. For each boiler model, the designer recommends the precise firing head length (or min/max range) to adapt it to the thickness of the front wall or geometric shape of the combustion space. In…
-
PART NUMBER 24300BL BOLTS: 6 X M12 THREAD IN THE HOLES (M10) AND WELD STUDS N. 6xØ14 THROUGH-HOLE, NOT THREADED 00 Ø 4 Ø BURNER СТОРОНА ГОРЕЛКИ SIDE 28 0 BOILER СТОРОНА SIDEКОТЛА N. 4xM10 10 233 Ø 440 PART NUMBER 24300DF 53 ° 60 THROUGH-HOLE, СКВОЗНЫЕ ОТВЕРСТИА NOT THREADED N.6xØ14 M10 THREAD…
-
COUNTERFLANGE SELECTION
PART NUMBER 24300V2 THROUGH-HOLE, NOT THREADED THREAD IN THE HOLES (M12) AND WELD STUDS BURNER SIDE BOILER SIDE PART NUMBER 24300Z6 THROUGH-HOLE, NOT THREADED THREAD IN THE HOLES (M10) AND WELD STUDS BURNER SIDE BOILER SIDE PART NUMBER 24300N7 THROUGH-HOLE, NOT THREADED THREAD IN THE HOLES (M16) AND…
-
FREQUENCY INVERTER FOR BURNERS
ELECTRONICALLY CONTROLLED Burners with electronic control and a separate fan can be supplied with a motor directly actuated or, as an alternative, indirectly actuated, i.e. via frequency inverter (Variable Speed Drive, VSD). In order to choose a burner equipped with a frequency inverter with…
-
GENERAL OPTIONS BURNERS
PROBES FOR MODULATORS Variable to be checked Temperature/Pressure scale Code Temperature -15 ÷ 50 °C 2.56.01.35 Temperature 30 ÷ 130 °C 2.56.01.C3 Temperature 0 ÷ 400 °C 2.56.01.45 Temperature 0 ÷ 1200 °C 2.56.01.42 Pressure 3 bar 2.56.01.C4 Pressure 10 bar 2.56.01.C5 Pressure 16 bar 2.56.01.C6…
-
SPACERS
-
OPTIONS GAS BURNERS
-
PRESSURE GOVERNORS WITH GAS FILTERS (threaded: Pe max 1 bar)
Gas connections Model Code ½” S.P.15 2.80.00.85 ¾” S.P.20 2.80.00.94 1” S.P.25 2.80.00.72 1”½ S.P.40 2.80.00.65 2” S.P.50 2.80.00.67 PRESSURE GOVERNORS WITH GAS FILTERS (flanged: Pe max 1bar) Gas connections Model Code DN65 S.P.65 2.80.00.69 DN80 S.P.80 2.80.00.71 DN100 S.P.100 2.80.00.74 MAXIMUM…
-
OPTIONS GAS BURNERS
GAS PRESSURE REDUCING STATIONS Gas pressure reducing stations (available for inlet pressures up to 6 bar and max flow rate corresponding to an output of 20.000 kW). Type Power (kW) Capacity (Nm3/h) Burners* Max pressure (bar) GRG30 GRG130 GRG200 3000 13000 20000 320 1370 2100 TP92A TP1030A 2 x…
-
OPTIONS LIGHT OIL BURNERS
VACUUM GAUGE Model Code Glycerine vacuum gauge -1 ÷ 0 bar (¼” connection) 2520008 FILTERS Model Code Filter 1” 0,1 big 2090018 Filter 51000/25 - 2” 2090022 MANOMETER Model Code Glycerine gauge 0 ÷ 40 bar (¼” connection) 2520003 Glycerine gauge 0 ÷ 6 bar (¼” connection) 2520006 Glycerine gauge 0 ÷ 10…
-
таблицы и схемы — в просмотре
-
OPTIONS HEAVY OIL BURNERS
HEAVY OIL FILTERS Model Code Filter 1” 0,3 micron big up to burner size 90-500 2090207 Filter 1½” 0,3 for PBY90-500 2090236 Filter 51000/05 F (flanged DN50) (1000-2000 burners series)* 2090237 Magnetic filter 1½” max 500 kg/h 2090245 * With 300 W heater VACUUM GAUGE Model Code Glycerine vacuum gauge…
-
OPTIONS HEAVY OIL BURNERS
OIL PRE-HEATING TANK (STEAM/DIATERMIC OIL) Type Capacity kg/h Tank volume liters Electrical heaters kW Max temperature °C Max pressure bar HTS5 HTS10 HTS20 HTS30 HTS40 500 1.000 2.000 3.000 4.000 500 1.500 2.000 3.000 4.000 80÷100 80÷100 80÷100 80÷100 80÷100 Vertical cylindrical tanks, provided with…
-
CRUDE AND HEAVY OIL PRESSURE REGULATOR GROUPS
-
ACOUSTIC HOODS BOX ASSEMBLED ON WHEELED FRAME
All burners in this catalogue have lower than standard noise levels. If a further reduction of the noisiness is required, the customer has at disposal a series of acoustic hoods box that can be integrated in the system. The noise reduction range varies from 5 to 15 dB(A), depending on the design…
-
CERTIFICATO
Nr. 50 100 3422 - Rev.007 Si attesta che / This is to certify that IL SISTEMA QUALITÀ DI THE QUALITY SYSTEM OF C.I.B. UNIGAS S.p.A. SEDE LEGALE E OPERATIVA: REGISTERED OFFICE AND OPERATIONAL SITE: VIA L. GALVANI 9 IT - 35011 CAMPODARSEGO (PD) SEDE OPERATIVA: OPERATIONAL SITE: VIA L. GALVANI 11 IT…
-
2022/1-2023 - M029118CA Rel. 0
To print this catalogue we have used paper certified FSC®, Forest Stewardship Council®, supplied by producers respecting the environment, the forests, and who can exhibit specific product certifications. C.I.B. UNIGAS S.p.A. Via L. Galvani, 9 - 35011 CAMPODARSEGO (PD) - Italy Tel. +39 049 9200944…
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.