Каталог продукции Aermec - Центральные кондиционеры и вентиляционные установки
Продуктовый каталог Aermec по оборудованию обработки воздуха (центральные кондиционеры и приточно-вытяжные установки NCD, NCT, NCQ и др.): описания и технические данные. Документ на английском языке.
Загружаем документ…
Текст каталога
-
We treat the air that
you breathe.
-
Breathing innovation
excellence in air treatment. AERMEC is committed to creating highly efficient solutions to meet the different needs of plant engineering solutions in terms of air treatment. Combining innovation and deep expertise, we design customised solutions for centralised systems, embracing every application…
-
Our mission is to guarantee
the most suitable air for each environment and for the activities that take place there. Thinking together about the characteristics and qualities of the air in the rooms, creating and putting together the technologies that will make the required result possible, being present for normal management…
-
The air is not
an empty space. On the contrary, it is the condition in which we are immersed and within which all our activities take place. 03
-
From the past to the forefront
Aermec’s journey with air innovation. AERMEC, founded in 1961 by Giordano Riello, started a long tradition of innovation in air treatment with the first air conditioning units. Today, with more than 800 employees working on premises covering 130,000 m², it is one of the world leaders in HVAC&R, with…
-
Part of the Giordano Riello International Group, a family
business which has evolved into an international group, Aermec benefits from the support and opportunities provided by the global network. The group, founded in the 1920s with Officine Fratelli Riello, was a pioneer in the air conditioning industry and today, with 1,800 employees in more than 150…
-
of respect and collaboration. Customer Care We put the customer at the centre of everything we do. We are committed to understanding their needs and providing customised solutions. Industrial culture We have deep roots in the industrial sector, with a deep understanding of market needs and trends.…
-
Team
We promote an inclusive and collaborative working environment; We value the power of the team and the ability to work together towards a common vision. Synergies of the Giordano Riello International Group We are able to use the synergies within the Riello Group for technological development…
-
Quality Standards and Certifications
a commitment of excellence and safety. The machines and their components are tested in adequately equipped laboratories in order to give the customer the greatest confidence in the product purchased. The Eurovent, Vision 2000 and ISO 14001 quality certifications represent a guarantee of the maximum…
-
EUROVENT - Performance certification
Aermec is a member of the Eurovent program for air handling units (AHUs). Eurovent is a European association made up of 15 national bodies. Voluntary certification programs managed by Eurovent compare the technical characteristics declared by manufacturers in documentation and selection software…
-
Selection software: to optimise the work of
professionals in the sector. Aermec offers innovative software for the selection of HVAC&R products, allowing industry professionals to quickly view, choose and configure the characteristics of the products suitable for the air conditioning system in question. An in-house support service provides…
-
Training: to meet
sustainability challenges. Aermec has been offering training programmes for professionals in the HVAC&R sector for over 30 years, with technical seminars and in-company courses. Investments in training never stop, with courses taught by qualified teachers, both in the classroom and on-line, and…
-
With increasingly advanced systems,
it is the after-sales service that makes the difference. A relationship of trust with the market has been developed, thanks to the clarity and professionalism of our approach, combined with our experience, further strengthened by the reliability and professionalism of our after-sales service. The…
-
The after-sales service includes
Qualified technical support on all products Organisation and commissioning of the installed units Spare parts warranty Inspections on construction sites to verify the installation Scheduling of visits and maintenance Warranty support and extensions Provision of technical documentation on installed…
-
If the air is Aermec,
you’ll feel the difference. We design and manufacture state-of-the-art air handling units, heat recovery units and Rooftop units, perfectly integrated into systems for offices, hotels, hospitals, data centres, theatres, swimming pools, sports facilities and the food and pharmaceutical industries.…
-
1 NCD
Air handling units The NCD air handling units are the result of consolidated experience and in-depth studies and experiments in the field of aeraulic machines. The NCD series is designed to suit all contexts, both in terms of functionality and size, allowing you to meet different air treatment needs…
-
Over 100 sizes to meet
every need. GERMICIDAL LAMPS These are generally used in sequence with extremely high efficiency filtration systems, to keep the bacterial flora and germs that are mainly formed in heat exchange batteries and condensate collection tanks under control. 3 HEAT RECOVERY UNITS Static cross-flow; static…
-
NCD AIR HANDLING UNITS
The NCD units are designed for civil, commercial and hotel contexts, with 109 sizes to cover applications in every room, whatever its dimensions. 1 The load-bearing structure uses aluminium alloy profiles, also available in an ano- dised version and with a thermal break to improve performance in…
-
SPECIAL FEATURES
IONIZER MODULES The installation of the ionizer modules keeps the unit sanitised over time. The oxidising ions generated by photocatalytic oxidation destroy bacteria, viruses, moulds, allergens and odours. HUMIDIFICATION SYSTEMS The humidification systems are chosen based on the specific use and the…
-
THE MATERIALS
Aluminium profiles are available in the following versions: - aluminium with natural finish - anodised aluminium - aluminium with natural thermal break finish - anodised aluminium with thermal break 1 The thermal and acoustic insulation of the panels can be achieved with: - polyurethane - mineral…
-
NCD HYGIENIC
AIR HANDLING UNIT AIR FLOW RATE FROM 1,000 TO 62,000 m3/h See all the features The units of the NCD VDI 6022 series are certified according to the strict requirements of the German standard VDI 6022, internationally recognised for hygiene standards in ventilation and air conditioning units. The…
-
NCD HYGIENIC
AIR HANDLING UNIT AIR FLOW RATE FROM 1,000 TO 62,000m3/h 1 The units of the NCD DIN 1946-4 series are certified according to the strict requirements of the DIN 1946-4 standard, certification of conformity referring to the hygiene requirements for ventilation in facilities and rooms of the health…
-
Air handling unit for specific applications The characteristics of places like swimming pools, wellness centres and fitness centres require specific plant engineering solutions and air treatment systems that combine top energy savings with environmental comfort needs. These systems, generally of the…
-
Dive into comfort without wasting
energy. The SPL 025/130 and SPL 160/250 units are innovative solutions designed for dehumidification and air treatment in swimming pools, combining energy efficiency, ease of use and durability. These units are the ideal choice to ensure a comfortable and safe environment in the swimming facilities.…
-
ADVANTAGES
Optimisation of energy efficiency with heat recovery and savings on pool water heating costs. Improved durability thanks to the anodised aluminium structure and corrosion-resistant panelling. Efficient operation and reduced operating costs thanks to the use of painted plug fans. Simplified…
-
SPL 025/130
AIR HANDLING UNIT FOR SPECIFIC APPLICATIONS AIR FLOW RATE FROM 2,500 TO 13,000 m3/h The units of the SPL 025/130 series are ideal for providing wellness conditions in small and medium-sized environments, such as spas, wellness centres, small swimming pools, and sports facilities. See all the…
-
Nominal airflow (supply/extract) M³/h 2500 Available pressure (supply/extract) Pa 400 Heat recovery capacity recovered (1) KW 7,90 Max heat recovery efficiency (1) % 80,80 Refrigerant circuit recovered capacity (1) KW 7,50 Total recovered capacity (1) KW 15,40 Compressor absorbed power (1) KW 1,30…
-
SPL 160/250
AIR HANDLING UNIT FOR SPECIFIC APPLICATIONS AIR FLOW RATE FROM 16,000 TO 25,000 m3/h SPL 160/250 units are the ideal solution for guaranteing well-being in medium/large-sized wellness areas such as spas, wellness centres, swimming pools, sports facilities, etc. See all the features The simplicity of…
-
SPL
Nominal air flow rate (supply / recovery) Available pressure (supply/recovery) Heat recovery capacity recovered Max heat recovery efficiency Refrigerant circuit recovered capacity Total recovered capacity Compressor absorbed power COP COP Total dehumidification capacity Supply fan power input…
-
Heat recovery units Units for the service sector Recent research shows that people spend almost 90% of their time in closed spaces. In this situation, the HVAC&R (Heating, Ventilation, Air Conditioning, and Refrigeration) system must be able to ensure comfort, energy efficiency as well as the health…
-
Air quality for quality of life
in the service sector buildings. Traditionally, comfort was the main parameter for evaluating an HVAC&R. This includes managing temperature and humidity to ensure a comfortable environment for people. With the regulatory evolution, energy efficiency has become crucial. Our systems guarantee…
-
SPECIAL FEATURES
• Focus on improving indoor air quality (IAQ) to ensure healthy and safe environments. dress emerging air quality challenges. • Over 30 years of experience in the sector. • Control of the presence of dust, pollutants and microorganisms in the air. • Flexible and customisable solutions for different…
-
RPS
HEAT RECOVERY UNITS AIR FLOW RATE 800 m3/h RPS is a cutting-edge counterflow heat recovery unit, perfectly suited for retrofitting classrooms, offices, hotels, bars, restaurants, and retail spaces. With its sleek, compact design and unmatched installation flexibility, it blends seamlessly into any…
-
RPS
Power supply Unit type Nominal/maximum fresh air rate Nominal/maximum exhaust air rate Heat recovery system type Winter thermal efficiency Heat capacity recovered in winter Summer thermal efficiency Heat capacity recovered in summer Maximum electric input power Sound power LwA 800 230V ~ 50Hz UVNR…
-
REPURO
HEAT RECOVERY UNITS AIR FLOW RATE FROM 100 TO 650 m3/h REPURO is an innovative counterflow heat recovery system, designed to ensure effective and continuous air renewal in enclosed spaces. Thanks to its high-efficiency heat exchangers, it delivers fresh air at a temperature close to the indoor…
-
таблицы и схемы — в просмотре
-
TRS
HEAT RECOVERY UNITS WITH ENTHALPY EXCHANGER AIRFLOW RATES FROM 250 TO 1.300 m3/h The unit features a high-efficiency counterflow heat exchanger made of special flat paper sheets, allowing for the recovery of both sensible and latent heat (humidity). As a result, there is no need for a condensate…
-
Fans
Nominal air flow rate Nominal useful head Maximum input power Type Speed number SFP int. Maximum input power Sound data (1) Sound pressure level (1 m) Heating performances (2) Winter thermal efficiency Enthalpy winter efficiency Cooling performances (3) Summer thermal efficiency Summer enthalpy…
-
RPLI
COUNTERFLOW HEAT RECOVERY UNITS AIRFLOW RATES FROM 300 TO 3.900 m3/h The RPLI heat recovery unit, ideal for horizontal indoor installations, is the perfect solution for those seeking year-round energy efficiency and comfort. Its counterflow heat exchanger ensures optimal thermal recovery: fresh air…
-
RPLI-L
Size Heat recovery unit Power supply 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 400V 3~50Hz Ventilation units type UVNR (Unità di Ventilazione Non Residenziale) Heat recovery system type tipo/n° Statico a flussi controcorrente / 1 Heat capacity recovered (EN308) (1) kW 1,6…
-
RTD
THERMODYNAMIC HEAT RECOVERY UNITS WITH INTEGRATED HEAT PUMP AIRFLOW RATES FROM 1100 TO 3.200 m3/h A compact and highly efficient unit for air renewal, filtration, and treatment, equipped with thermodynamic heat recovery via an integrated refrigeration circuit. Thanks to the Inverter compressor, it…
-
RTD11
RTD14 RTD17 RTD21 RTD26 RTD32 Air flow rates Nominal air flow rate m³/h 1100 1400 1700 2100 2600 3200 Minimum air flow rate m³/h 950 1200 1450 1800 2200 2700 Maximum air flow rate m³/h 1200 1550 1850 2300 2850 3500 Delivery fan Type type Plug-fan Plug-fan Plug-fan Plug-fan Plug-fan Plug-fan Fan…
-
RPF
HIGH-EFFICIENCY HEAT RECOVERY UNITS WITH COUNTERFLOW HEAT EXCHANGER AIRFLOW RATES FROM 790 TO 4.250 m3/h RPF heat recovery units are the ideal solution for commercial applications requiring the perfect balance between indoor comfort and energy efficiency. Thanks to their counterflow heat exchangers…
-
RPF008
-
URX-CF
HEAT RECOVERY UNITS WITH INTEGRATED HEAT PUMP AIRFLOW RATES FROM 750 TO 3.300m3/h The URX-CF units provide a complete and compact solution for air treatment. This all-in-one monoblock integrates ventilation, filtration, heat recovery, and a heat pump refrigeration circuit with high-efficiency…
-
Heat recovery unit
Power supply Cooling performances (1) Total cooling capacity (heat recovery + refrigerant circuit) Cooling capacity available Cooling capacity recovered Summer thermal efficiency Total input power Heating performances (2) Heating capacity total (heat recovery + refrigerant circuit) Heating capacity…
-
URHE-CF
HEAT RECOVERY UNITS WITH INTEGRATED HEAT PUMP AIRFLOW RATES FROM 1.000 TO 3.300m3/h URHE-CF units deliver maximum efficiency by combining a high-performance crossflow plate heat exchanger with a heat pump refrigeration circuit using R410A refrigerant. The high-efficiency heat exchanger significantly…
-
Heat recovery unit
Power supply Cooling performances (1) Total cooling capacity (heat recovery + refrigerant circuit) Cooling capacity available Cooling capacity recovered Summer thermal efficiency Total input power Heating performances (2) Heating capacity total (heat recovery + refrigerant circuit) Heating capacity…
-
ERSR
HEAT RECOVERY UNITS AIR FLOW RATE FROM 1,000 TO 30,000 m3/h The ERSR units are designed to offer superior performance in the management of air quality and thermo-hygrometric comfort in residential environments. See all the features Configurations ERSR Horizontal Configuration Right delivery (top…
-
Dimensions 55
-
HANDLING UNIT Applications for the Tertiary Sector Fan coil units are the ideal solution to ensure maximum indoor comfort in any setting—residential, commercial, or industrial. Designed to heat, cool, and distribute air evenly throughout the space, these units combine efficiency, quiet operation…
-
TVS
AIR HANDLING UNITS AIRFLOW RATES FROM 800 TO 5.200 m3/h High-Performance Ductable handling Unit. Designed to deliver high static pressure in small and medium-sized environments, ensuring comfort and installation flexibility. Standard-configured for 2-pipe systems, it can be easily adapted to 4-pipe…
-
TVS084
TVS154 Performance in heating mode 70 °C / 60 °C - Main coil 2-pipe system (1) Heating capacity kW 10,50 18,80 Water flow rate l/h 901 1615 Pressure drop kPa 26 25 Performance in heating mode 45 °C / 40 °C - Main coil for 2-pipe systems (2) Heating capacity kW 5,20 9,30 Water flow rate l/h 896 1600…
-
TVH
AIR HANDLING UNITS AIRFLOW RATES FROM 800 TO 5.200 m3/h High-Performance Ductable handling Unit Designed to deliver high static pressure in small to medium-sized environments, ensuring comfort and installation flexibility. Standard configuration is suitable for 2-pipe systems, but it can be easily…
-
TVH084
Performance in heating mode 70 °C / 60 °C - Main coil 2-pipe system (1) Heating capacity kW 11,60 Water flow rate l/h 994 Pressure drop kPa 31 Performance in heating mode 45 °C / 40 °C - Main coil for 2-pipe systems (2) Heating capacity kW 5,70 Water flow rate l/h 985 Pressure drop kPa 33 Heating…
-
TS
AIR HANDLING UNITS AIRFLOW RATES FROM 810 TO 4.225 m3/h Ductable handling Unit An ideal solution for small to medium-sized residential, commercial, and hotel installations. Designed for ceiling-mounted installation, it stands out for its compact design and quiet operation. A wide range of…
-
Unit designed to operate with all recirculating air or maximum 10% of external air
-
TA
-
Unit designed to operate with all recirculating air or maximum 10% of external air
-
TN
AIR HANDLING UNITS AIRFLOW RATES FROM 3.000 TO 23.000 m3/h Compact Solution Ideal for Filtration, Cooling, and/or Heating Only. Suitable for residential, commercial, industrial, and hotel applications, these units can be installed in either horizontal or vertical configurations. They feature low…
-
TN 1-8 with 4-row water coil
TN Cooling performance 7 °C / 12 °C (1) Cooling capacity kW Sensible cooling capacity kW Heating performance 70 °C / 60 °C (2) Heating capacity kW Performance in heating mode with additional coil for 4-pipe systems Heating capacity with 2 row water coil kW Heating capacity with 3 row water coil kW…
-
ROOF-TOP Applications for the service sector Designed for rooftop installation, high-efficiency Roof-top stand-alone HVAC units stand out for their compactness and ease of installation making them the ideal solution for commercial and industrial applications. Available in different configurations…
-
Efficiency and air quality
configurable with various accessories. ROOF-TOP units are characterised by energy efficiency, as well as high air quality and considerable versatility, thanks to their ability to adapt to different specific needs. Designed to be placed on the roof, these units allow you to optimise the internal…
-
A complete range
RTX Series Roof-top Unit: for medium sized applications such as shopping centres, with an external air flow rate not exceeding 50%. Available in 23 sizes, it has air flow rates from 2,000 to 48,000 m³/h and thermal power from 10 to 300 kW. All units (except the first 8 sizes) can be configured for…
-
Available configurations
-
RTX N1-N8
APPLICATIONS FOR THE SERVICE SECTOR COOLING CAPACITY FROM 13 TO 50 kW The roof-top units of the RTX range are designed for applications with medium occupancy such as shopping centres, shops, offices and production areas, as they can operate with 30% of fresh and exhaust air (MB4 version). See all…
-
таблицы и схемы — в просмотре
-
RTX N1-N8
General Technical Data Fans 78
-
RTX 09-16
APPLICATIONS FOR THE SERVICE SECTOR COOLING CAPACITY FROM 50 TO 135 kW The ROOF-TOP units of the RTX range are autonomous air units designed to completely treat the air. These units are ideal for places with an average degree of crowding such as shopping centres, shops, offices and production areas…
-
RTX 09-16
Technical data Energy Index General Technical Data Fans 82
-
таблицы и схемы — в просмотре
-
RTX 17-23
APPLICATIONS FOR THE SERVICE SECTOR COOLING CAPACITY FROM 152 TO 305 kW The roof-top units of the RTX range are autonomous air-to-air units designed to completely treat the air. The units are also characterised by their extensive operating limits (from -20° C to +48° C). These units are ideal for…
-
таблицы и схемы — в просмотре
-
RTX 17-23
General Technical Data Fans Dimensions 86
-
RTY 01-10
APPLICATIONS FOR THE SERVICE SECTOR COOLING CAPACITY FROM 30 TO 140 kW The roof-top units of the RTY range are autonomous air-to-air units designed to completely treat the air. These units are ideal for places where there is a high degree of crowding such as cinemas, conference halls, restaurants…
-
Fans
-
RTY 01-10
General Technical Data Dimensions 90
-
ROOF-TOP RTG
Efficiency and sustainability, with R32 refrigerant with low GWP The RTG range consists of Roof-Top air condensed independent air conditioning units equipped with heat pump, suitable for shopping centres, shops, offices, production areas. Operation possible with up to 50% fresh air in MB2, MB4, MBT…
-
Available configurations
MB1 Single ventilating cross-section for recovery air MB2 Single ventilating cross-section for recovery and external air SA SA OA RA RA • Recovery air only configuration where no fresh air is required. • The useful flow and recovery static pressure is provided by the flow ventilatincross-section. •…
-
APPLICATIONS FOR THE SERVICE SECTOR COOLING CAPACITY FROM 57.7 TO 165.3 kW HEAT CAPACITY FROM 58.1 TO 164.6 kW See all the features Roof-top unit with R32 refrigerant • High power modulation capability • Inverter compressors and fans • Enhanced thermodynamic heat recovery • Different configurations…
-
Accessories
Refer to the selection software for compatibility of accessories. MB1: Single fan section - Recirculation MB2: Single fan section - Recirculation + Renewal MB4: Double fan section - Recirculation Renewal + Exhaust - Thermodynamic recovery MBT: Double fan section - Recirculation + Renewal + Exhaust…
-
Technical data Unit input power: at nominal air flow rate, nominal high static pressure and standard fans MB1 Size Configuration: MB1 Cooling performances Cooling capacity Sensible cooling capacity Compressors absorbed power EER compressors Unit input power Heating performances Heating capacity…
-
MBT
Size Configuration: MBT Cooling performances Cooling capacity Sensible cooling capacity Compressors absorbed power EER compressors Unit input power Heating performances Heating capacity Compressors absorbed power Compressor COP Unit input power kW kW kW kW kW kW kW 66,00 51,50 15,50 4,25 20,5 88,80…
-
Size
Power supply Power supply Compressor Type Number Circuits Refrigerant Compressor regulation Sound data Sound power level V/Ph/Hz 400V~3 50Hz 400V~3 50Hz 400V~3 50Hz 400V~3 50Hz type no. no. type Type Scroll 2 2 R32 Inverter Scroll 2 2 R32 Inverter Scroll 2 2 R32 Inverter Scroll 2 2 R32 Inverter…
-
A
-
APPLICATIONS FOR THE SERVICE SECTOR COOLING CAPACITY FROM 57,7 TO 128,1 kW HEAT CAPACITY FROM 58,1 TO 124,6 kW See all the features Roof-top unit with R32 refrigerant • High power modulation capability • Inverter compressors and fans • Enhanced thermodynamic heat recovery • Different configurations…
-
Accessories
Refer to the selection software for compatibility of accessories. MB4: Double fan section - Recirculation Renewal + Exhaust - Thermodynamic recovery MBT: Double fan section - Recirculation + Renewal + Exhaust - Enhanced thermodynamic recovery MO: Horizontal air flow MI: Lower air flow MS: Upper air…
-
Energy Index Size Energy index SEER ηsc SCOP ηsh 6,10 241,20 4,41 173,30 6,32 249,90 3,93 154,20 6,44 254,60 3,93 154,10 400V 3~ 50Hz 400V 3~ 50Hz 400V 3~ 50Hz type no. no. type Type Scroll 2 2 R32 Inverter Scroll 2 2 R32 Inverter Scroll 2 2 R32 Inverter dB(A) 84,0 86,0 90,0 W/W % W/W % In MB1…
-
A
-
Guided tours in the company
an experience of both innovation and charm. Come and visit our company and find out how AERMEC responds to the challenges of air treatment with customised and cutting-edge solutions. During the tour, you will have the opportunity to immerse yourself in our production processes and see up close the…
-
Via Roma, 996 37040 Bevilacqua (VR) - Italy Tel. + 39 0442 633 111 www.global.aermec.com
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.