OPERATION AND INSTALLATION
Integral cylinder » HSBC 300 cool » HSBC 300 L cool
-
CONTENTS | Special information
SPECIAL INFORMATION OPERATION 1. 1.1 1.2 1.3 1.4 1.5 General information��������������������������������������� 37 Relevant documents������������������������������������������� 37 Safety instructions���������������������������������������������� 37 Other symbols in this…
-
General information
1. 1.3 Other symbols in this documentation Note General information is identified by the adjacent symbol. ff Read these texts carefully. General information The chapters "Special information" and "Operation" are intended for both users and qualified contractors. Symbol Meaning Material losses…
-
Safety
2. Safety 3. 2.1 Intended use The appliance can be operated in conjunction with the following air | water heat pumps: This appliance is intended to be used for seasonal heating and cooling of interiors (7 °C / 12 °C) and for DHW heating. The appliance is intended for domestic use. It can be used…
-
Cleaning, care and maintenance
Cleaning, care and maintenance 6. Troubleshooting ff Have the electrical safety of the appliance and the function of the safety assembly regularly checked by a qualified contractor. ff Never use abrasive or corrosive cleaning agents. A damp cloth is sufficient for cleaning the appliance. Problem…
-
Safety
7. Safety Only a qualified contractor should carry out installation, commissioning, maintenance and repair of the appliance. 7.1 General safety instructions We guarantee trouble-free function and operational reliability only if original accessories and spare parts intended for the appliance are…
-
! Transport and handling 9.2.1 Removing / fitting the front casing Material losses Store and transport the appliance at temperatures between -20 °C and +60 °C. ff Tilt the appliance and screw the 4 adjustable feet into the appliance. ff Lift the appliance off the pallet. If narrow doors or hallways…
-
9.2.2 Overview of insulation segments
D0000080535 2 1 Insulation segment 1 2 Insulation segment 2 3 Insulation material screw 4 Insulation segment 3 42 | HSBC 300 cool | HSBC 300 L cool www.stiebel-eltron.com
-
9.2.3 Separating / joining the appliance sections
Separating the appliance sections D0000080287 ENGLISH Material losses Unscrewing the fastening screws destroys the threads in the insulation segment. ff To open the 3 fixing tabs, loosen the fastening screws slightly but do not unscrew them completely. D0000083254 D0000080288 ff Pull the "heating…
-
ff
Remove the 4 hydraulic hoses. ff Remove the 2 insulation material screws. ff Remove insulation segment 3. D0000074613 D0000080293 Installation Preparation ff Pull the upper section of the appliance towards the front. ff Undo the 2 locking screws on the side profile strips. ff Lift up and unhook the…
-
Joining appliance sections
ENGLISH Material losses To prevent condensation forming, the insulation segments must fit closely against the lower section with no gaps. ff When inserting the insulation segments, ensure that the joint grooves are kept clear ff Tap the insulation segments down with your hand. Rejoin the appliance…
-
10. Installation
10.1 Positioning the appliance ff When positioning the appliance, observe minimum clearances (see chapter "Preparations / Installation site"). ff Use the adjustable feet to compensate for any unevenness in the floor. 10.2 Heating water connection and safety valve 10.2.1 Safety instructions ! !…
-
10.2.2 Fitting the pump assembly (accessory) if required
WARNING Electrocution Before starting work on the appliance, disconnect all poles from the power supply and drain the heating circuit via the drain valve on the buffer cylinder. Preparation for installation of HSBC 3-HKM ff Remove the front casing and insulation segment 1 (see chapter "Installation…
-
ff
Insert the pipe assembly. ff Insert the flat gaskets into the union nuts for the connection pipes. ff Counterhold and secure the union nuts to the adaptors. ff Check the alignment of the pipes and functional elements of the pump assembly. Retighten all fittings. ff Install the profiles for the 3-way…
-
Electrical connection HSBC 3-HKM
XD03.2 XD03.3 MKP (X2.4) BU ENGLISH 4 N BK LZ LA MISCHER (X2.14) N L 11 2 (*) BN BK BU GNYE 9 L N L M 1~ MA11 MA19 D0000085473 M 1~ N BT13 XD04 9 “-” 10 T (MK) (X1.6) “+” D0000081761 (*) Pipe assembly inserted 9 Insulation mat for 3-way mixer and heating circuit pump 11 Profiles for 3-way mixer ff…
-
10.2.3 If necessary, install an HSBC 3-HE auxiliary heating
element as an accessory WARNING Electrocution Before starting work on the appliance, disconnect all poles from the power supply and drain the DHW cylinder. D0000080386 D0000080387 1 2 0° Electrical connection HSBC 3-HE In the delivered condition, the 3 wires for connecting the auxiliary heating…
-
D0000080544
ENGLISH Installation Installation ff Connect the 3 wires to the auxiliary heating element as shown. A BK / BN B BU PE GNYE Note The auxiliary heating element standard delivery includes two identical wiring diagram labels for covering "HSBC 3-HE (accessory X2.11)" on the wiring diagram: On the back…
-
10.2.4 Hydraulic connection
10.3.2 Installing the pipe assembly (accessory) if required Note ff Observe the details specified in the chapter "Installation / Specification / Hydraulic diagrams". WARNING Electrocution Before starting work on the appliance, disconnect all poles from the power supply and drain the DHW cylinder. ff…
-
10.4 Filling the system
Heating circuit water quality 1 To avoid damage as a result of scaling, it may be necessary to soften or desalinate the fill water. The fill water limits specified in chapter "Specification / Data table" must always be observed. ff Recheck these limits 8-12 weeks after commissioning and during the…
-
11. Electrical connection
10.5 Venting the appliance 1 WARNING Electrocution Carry out all electrical connection and installation work in accordance with relevant regulations. Before any work on the appliance, disconnect all poles from the power supply. 2 1 Air vent valve 2 Vent hose 3 Hose attachment ff Detach the vent hose…
-
11.1 Control voltage
Material losses ff Only connect energy efficient circulation pumps approved by us to the pump connections. ff Route all power cables and sensor leads into the appliance through the cable entry. ff Connect the power cables and sensor leads as detailed below. Install cables with the following…
-
11.2 Safety extra low voltage
11.4 Sensor installation D0000080433 Note The temperature sensor needs to be replaced on combined appliance system HSBC 300 L cool with WPF / WPF cool. ff Use the PTC temperature sensor that was included in the standard delivery of the heat pump. Terminal, safety extra low voltage T(MK) Mixer…
-
11.4.1 Temperature sensor for cooling (accessory), if required
D0000080426 ENGLISH Cooling requires the fitting of a temperature sensor, available as an accessory. ff Remove the front casing (see chapter "Preparations / Transport and handling / Removing / fitting the front casing"). D0000080288 ff Insert the temperature sensor into the sensor well "Sensor heat…
-
Commissioning
12. Commissioning Venting Our customer support can assist with commissioning, which is a chargeable service. If the appliance is intended for commercial use, observe the rules of the relevant Health & Safety at Work Act during commissioning. For further details, check with your local authorising…
-
Appliance shutdown
12.2 Appliance handover Draining the DHW cylinder 13. Appliance shutdown ! ! Material losses Observe the temperature application limits and the minimum circulation volume on the heat consumer side (see chapter "Specification / Data table"). Material losses Drain the system when there is a risk of…
-
15. Specification
15.1 Dimensions and connections d02 e01 e02 d01 b01 771 343 c06 c01 820 1360 1590 577 10-20 1904 1848 1326 c10 93 D0000077428 b01 c01 c06 c10 d01 d02 e01 e02 Entry electrical cables Cold water inlet DHW outlet DHW circulation Heat pump flow Heat pump return Heating flow Heating return 60 | HSBC 300…
-
Other dimensions and connections
ENGLISH i18 h16 h17 i01 h08 Sensor heat pump cooling, optional Sensor DHW Sensor, DHW, optional Sensor heating Flange i18 Protective anode Diameter Diameter Diameter Diameter External diameter Torque Female thread 15.1.1 HSBC 3-HKM accessories 393 e31 c10 504 c06 771 343 c01 1035 183 999 D0000080455…
-
D0000078314
-
Temperature sensor, heat pump buffer cylinder
Temperature sensor, DHW cylinder Temperature sensor HP flow HC2 (accessories HSBC 3-HKM) Motor, pump, heating circuit Motor, pump, heating circuit 2 Motor, buffer charging pump (not for HSBC 300 L cool and TSBC 300 L plus) Motor, diverter valve, heating, DHW Motor, mixing valve heating circuit 2 LV…
-
15.3 Hydraulic diagrams
D0000080569 HSBC 300 cool D0000080570 D0000080571 HSBC 300 L cool 64 | HSBC 300 cool | HSBC 300 L cool www.stiebel-eltron.com
-
15.4 Energy consumption data
Manufacturer Designation Energy efficiency class Standby losses Cylinder capacity W l HSBC 300 cool 236686 STIEBEL ELTRON HSBC 300 cool B 61 291 HSBC 300 L cool 238826 STIEBEL ELTRON HSBC 300 L cool B 61 291 15.5 Data table Hydraulic data Nominal capacity, DHW cylinder Nominal capacity, buffer…
-
Further details
Maximum altitude for installation HSBC 300 cool 236686 2000 m HSBC 300 L cool 238826 2000 15.6 Accessories Pipe assembly RBS-SBC RBS-SBC 238827 Connections Cold water connection DHW connection DHW circulation connection Versions Suitable for mm mm mm ...SBC 300 cool / plus and 300 L cool / plus Pump…
-
GUARANTEE | ENVIRONMENT AND RECYCLING
Guarantee ENGLISH The guarantee conditions of our German companies do not apply to appliances acquired outside of Germany. In countries where our subsidiaries sell our products a guarantee can only be issued by those subsidiaries. Such guarantee is only granted if the subsidiary has issued its own…