1 DESCRIPTION OF THE BOILER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pag. 62 2 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .…
-
FUNCTIONAL DIAGRAM IT ES KEY 1 Fan 3 Primary exchanger 4 C.H. sensor (SM) 5 Gas valve 6 D.H.W. exchanger 7 Heating water filter 8 Diverter valve 9 Safety thermostat 10 Circulator with air release vent 11 D.H.W. flow meter 12 Water inlet filter 13 System loading 14 3 BAR safety valve 15 Water…
-
MAIN COMPONENTS FORMAT DGT HE 25-30-35 KEY 1 Control panel 2 Fan 3 Mixer 4 Ignition electrode 5 C.H. sensor (SM) 6 Primary exchanger 7 Smoke chamber 8 Fumes sensor 9 Safety thermostat 10 Condensate collection tray 11 Diverter valve 12 Automatic vent 13 Circulator FORMAT DGT HE 12-20 T Fig. 3 66
-
INSTALLATION The boiler must be installed in a fixed location and only by specialized and qualified firms in compliance with all instructions contained in this manual. Furthermore, the installation must be in accordance with current standards and regulations. 2.1 INSTALLATION – Boilers can be…
-
and act on the boiler drain (5 fig. 6)
NB: In “T” vers. loading is achieved by the appropriate connection (10 fig. 6). separate the exhaust fumes pipes from the air suction pipes (fig. 9): - for ø 80 pipes, divider code 8093050 is provided upon request. 2.7 - for ø 60 pipes, divider code 8093060 is provided upon request. INSTALLATION OF…
-
ES
2 PT 3 1 GB KEY 1 Divider with vent 2 Elbow product discharge 3 Air intake bend CA Inlet CS Outlet Fig. 9 TABLE 1 - ACCESSORIES ø 80 Accessories ø 80 12 Inlet 20 Outlet Inlet Total head loss (mm H2O) 25 Outlet Inlet Outlet Air/smoke divider – – – – – 90° elbow MF 0.05 0.10 0.15 0.20 0.20 45° elbow…
-
C43 C33 C53 IMPORTANT: In type C53 the outlet and inlet flues must not come out on opposite walls. max 0,5 m 3 C83 1 LIST OF ø 80 ACCESSORIES 1 2 3a 3b Air/smoke divider code 8089912 Additional 90° MF curve code 8077450 (6 pz.) Extension L. 1000 code 8077351 (6 pz.) Extension L. 500 code 8077350 (6…
-
FORCED EXHAUST (Type B23P-53P) IT Cod. 8089501 ES This type of exhaust pipe is installed using air/smoke divider, code 8093050/60. For kit assembly instructions, refer to point 2.8. Protect the intake with the optional accessory, code 8089501 (fig. 10/a). The maximum overall length, resulting from…
-
fused main switch, with at least 3 mm spacing between contacts. Respect the L and N polarities and the earth connection. NOTE: SIME declines all responsibility for injury or damage to persons, animals or things, resulting from the failure to provide for proper earthing of the appliance. 2.11.1…
-
BASIC SYSTEM MULTI-ZONE SYSTEM WITH VALVE, ROOM THERMOSTATS, REMOTE CONTROL (Code 8092219), KIT EXPANSION REMOTE CONTROL (Code 8092240) AND EXTERNAL SENSOR (Code 8094101) CR EXP M SE TA2 TA1 R VZ VZ1 VZ2 PARAMETERS SETTINGS Set the opening time of the VZ zone valve: PAR 17 = SYSTEM PUMP ACTIVATION…
-
BOILER ELECTRICAL “12-20 T” PA (24 VDC) EXP (24 VDC) SE (3,3 VDC) SB (3,3 VDC) SF (3,3 VDC) TA (24 VDC) TS (3,3 VDC) SM (3,3 VDC) SL (24 VDC) KEY F TRA PI V EA EV1-2 VD SL SM SB TS SF PA Fuse (1.6 AT) Ignition transformer System pump Fan Ignition electrode Gas valve coil Deviator valve Level…
-
BOILER ELECTRICAL “25-30-35” IT ES PT GB PA (24 VDC) EXP (24 VDC) SE (3,3 VDC) S.AUX (3,3 VDC) TA (24 VDC) FLM (12 VDC) SF (3,3 VDC) SM (3,3 VDC) TS (3,3 VDC) SL (24 VDC) KEY F TRA PI V EA EV1-2 VD SL SM TS FLM SF PA Fuse (1.6 AT) Ignition transformer System pump Fan Ignition electrode Gas valve…
-
CHARACTERISTICS 3.1 CONTROL PANEL - DESCRIPTION OF DISPLAY ICONS SUMMER MODE ICON WINTER MODE ICON D.H.W. MODE ICON 2 - DESCRIPTION OF CONTROLS OPERATING MODE/RESET By pressing the key in succession, pass to the summer and winter function (stand-by function if permane on the key more than two…
-
ACCESS TO INSTALLER'S PARAMETERS For access to the installer's parameters, press simultaneously the keys of boiler panel ( and ) for 5 seconds. The red LED flashes and the display shows: 01 Combustion configuration 09 Fan rpm Step ignition D.H.W. - HEATING PAR DESCRIPTION RANGE 02 Hydraulic…
-
EXTERNAL SENSOR If there is an external sensor, the heating settings SET can be taken from the climatic curves (PAR 12) according to the external temperature and, in any case, limited to with the range values described in point 3.2 (parameters PAR 13 and PAR 14). The climatic curve to be set can be…
-
in the boiler (< 0,6 bar)
To restore burner functioning, to bring back the pressure of the boiler at values comprise between 1 - 1,2 bar. 3.8 HEAD AVAILABLE TO SYSTEM Residual head for the heating system is shown as a function of rate of flow in the graph in fig. 15. To obtain the maximum head available to the system, turn…
-
USE AND MAINTENANCE 4.1 GAS VALVE (fig. 17) The boiler is supplied as standard with a gas valve, model SIT 848 SIGMA. KEY 1 Upstream pressure intake 2 Intermediate pressure intake 3 Air signal inlet (VENT) 4 Downstream pressure intake 5 Capacity step 6 OFF-SET Fig. 17 4.3 GAS CONVERSION (fig. 18)…
-
ES
PT GB 1 Codice/Code 8108100 Modello/Model FORMAT DGT HE 25 Matricola/Serial n. 9999999999 PAR 1 = 02 (METANO)/ 06 (GPL) PAR 2 = 01 2 4x Fig. 19 and usage conditions. In any case, it should be inspected at least once a year by a qualified technician. During maintenance operations, it is important to…
-
system flow/return shut-off taps, turn control board power off, remove the casing
and empty the boiler through the relevant drain. Place a collecting vessel under the filter. Use pliers to remove the filter from the relevant inserted tongue and clean it removing impurities and lime scale deposits. that the seal of the heating circuit is intact (check that there are no leaks).…
-
– FUMES PROBE ANOMALY “AL 14”
When the fumes probe is opened or short-circuited, the boiler stops and the displays shows anomaly AL 14. IT ES – FAN ANOMALY “AL 15” Fan revolutions are not within the preestablished speed range. If the anomaly activation condition lasts for over two minutes, the boiler will forcedly stop for…
-
USER INSTRUCTIONS
WARNINGS – In case of fault and/or incorrect equipment operation, deactivate it, without making any repairs or taking any direct action. Apply only to qualified technical personnel. – Boiler installation and any other assistance and/or maintenance activity must be carried out by qualified personnel…
-
REGULATION OF THE WATER
TEMPERATURE FOR HEATING (fig. 26) IT To set the temperature of the water for heating, press the key of the controls . The display will be as shown in the figure. Change the values with the key ( and ). Standard visualisation will return to the display by pressing the key again, or after 60 seconds…
-
ANOMALIES AND SOLUTIONS
When there is a functioning anomaly, the display controls shows and red led switch on. Descriptions of the anomalies with the relative alarms and solutions are given below: – AL 01 (fig. 29) Press the key of the controls to restart the boiler. If the anomaly persists, request the intervention of…
-
TAGLIARE LUNGO LA LINEA TRATTEGGIATA
DICHIARAZIONE DI CONFORMITA’ CALDAIE MURALI A GAS La FONDERIE SIME S.p.A., con riferimento all’art. 5 DPR n°447 del 6/12/1991 “Regolamento di attuazione della legge 5 marzo 1990 n°46” ed in conformità alla legge 6 dicembre 1971 n° 1083 “Norme per la sicurezza dell’impiego del gas combustibile”…
-
Rendimenti caldaie murali a gas
-
Cod. 6274278 - 09/09 - Documentation Dpt
Fonderie Sime S.p.A - Via Garbo, 27 - 37045 Legnago (Vr) Tel. + 39 0442 631111 - Fax +39 0442 631292 - www.sime.it
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.
Другие файлы документа
- Газовый конденсационный котел с закрытой камерой сгорания Format DGT HE 12 T. Запчасти.PDF · 49.72 Kb
- Газовый конденсационный котел с закрытой камерой сгорания Format DGT HE 20 T. Запчасти.PDF · 49.83 Kb
- Газовый конденсационный котел с закрытой камерой сгорания Format DGT HE 25. Запчасти.PDF · 75.67 Kb
- Газовый конденсационный котел с закрытой камерой сгорания Format DGT HE 30. Запчасти.PDF · 75.60 Kb
- Газовый конденсационный котел с закрытой камерой сгорания Format DGT HE 35. Запчасти.PDF · 75.63 Kb
- БуклетPDF · 6.69 Mb