G PAIII series Energy-saving Pipeline Canned Motor Pump Installation and Operation Manual HEFEL XINHU CANNED MOTOR PUMP CO.,LTD.
-
Notes
1. The installation manual should be read carefully before installation and use. impellers. 10. It is prohibited to start pump when there is pumping liquid. 2. Any failure to comply with the content marked by safety warning marks may causepersonal injury, pump damage and other property loss, for…
-
on the pump inlet end and cut off the pump power, besides, immediately
contact your local dealer or service center. 18. If the pump failure can not be cleared in accordance with the description in the instructions, immediately turn off the valve on the pump inlet end and cut off the pump power, besides, immediately contact your local dealer or service center 19. The…
-
2. Overview
2 . 1 . G PA III series circulating pump(also called in abbreviation of “pump”) is mainly used for the water circulation in home heating and domestic hot water system. 2.2. Advantages of installation of the pump Easy installation and start-up · The pump has autoadaptation mode AUTO (factory…
-
3. Service conditions
3.1. Ambient Temperature Ambient temperature: 0 ℃~ +70 ℃ 3.2. Relative humidity(RH): Max. humidity: 95% 3.3. Media (conveying liquid) temperature Temperature of liquid conveying +2 ℃~ 110 ℃ . To prevent the control box and stator from appearing condensate water, the temperature of pump conveying…
-
4. Installation
4.1Installation ·Install the pump, arrows on the pump housing indicate the direction of liquid flowing through the pump body. ·When the pump is installed on the pipeline, its inlet and outlet must be installed with two leather packings provided. ·During installation, the pump shaft must be in the…
-
4.2Position of Junction Box
4.3 Position of junction box The junction box can rotate in 90°.To change the position of junction box, follow the operating steps below: 1. Switch the valves of inlet and outlet and conduct decompression; 2. Loosen and remove the four socket head cap screws that fix the pump body; 3. Rotate the…
-
Warning
Pumping liquid may be of high temperature and pressure, therefore, liquid in the system should be drained off or valves on both sides of the pump must be switched off before removing socket head cap screws. Catution Change the position of junction box, the pump should not be started until the system…
-
СРАШ
-
Electrical connection and protection should be
carried out in accordance with local regulations. Warning The pump must be connected to earth wire The pump must be connected with an external power switch; the minimum gap Between all the electrodes is 3mm. · The pump does not need external motor protection. · Check whether the voltage of power…
-
6. Control Panel
6.1 Controls on Control Panel NO. Explanation 1 The pump I,II,III gear display 2 The pump automatic gearshift display (AUTO) 3 The pump PWM gear display 4 The pump gear shifting button Special Note: 1. If I and II display at the same time, means BL1. If I and III display at the same time, means BL2.…
-
6.3 Light area displaying the settings of the pump
The pump has 9 kinds of settings, which can be selected by buttons. The setting of the pump is indicated by the light lit of 10 locations: Key position 4 Number of times of key Fixed light area Explanation 0 AUTO Auto adaptation BL1/BL2/BL3 Proportional pressure curve HD1/HD2/ HD 3 Constant pressure…
-
Position
A B C Settings of the pump System Type Optimal settings Or other optional settings HS3 Floor heating system AUTO BL3 Dual pipeline heating system AUTO Single pipeline heating system HS3 AUTO · AUTO (auto adaptation) mode shall adjust the pump performance automatically according to the actual heat…
-
8.PWM Signal Control Mode
8.1Control and Signal 1) Control Principle The pump is controlled by modulated LV PWM (Pulse Width Modulation) digital signal, which means that the variance of velocity depends on the external input signal. The variance of velocity is one of the functions of input control. 2) Digital LV PWM (Pulse…
-
8.3 PWM Input Signal
·In area of high duty-cycle PWM signal, when the input signal fluctuates in the critical point, there will be a delay area to prevent frequent stop and start of the pump. · In area of low duty-cycle PWM signal, the pump runs at high velocity for the sake of system safety. For instance, when the…
-
8.4 PWM Feedback Signal
PWM feedback signal can provide operation status of the pump, such as power loss or all kinds of alarm/warning modes. PWM feedback signal will feed back exclusive alarming information. If the power voltage detects under voltage signal values, its output signal will be set to 75%. Provided sundries…
-
9.A bypass valve system is fitted between
the inlet pipeline and return pipeline 9.1 Use of bypass valve Bypass valve The role of bypass valve is: when all the valves in the floor heating circuit or the temperature control valve of radiator are closed, it can be ensured that the heat from the boiler will be assigned. Elements in the system…
-
The pump settings depend on the type of bypass valve it equipped with,
i.e. manually-operated bypass valve or temperature-controlled bypass valve. 9.2 Manually- operated bypass valve Follow the following steps: 1. When adjusting the bypass valve, the pump should be in setting HS1 ( constant speed gear I mode) . The minimum flow of system ( Q min) must always be…
-
10.3 Gas-exhausting of heating system
11.Settings and performance of pump 11.1Relationship between pump settings and its performance 18
-
Setting
AUTO (factory settings) Pump Characteristics Curve Functions "Autoadaptation" function will automatically control the pump performance within the specified range. Highest to Lowest ·Adjust the performance of the pump according to the size of system; Proportional · Adjust the performance of the pump…
-
·GPAXX-4 III Performance curve
·GPAXX-5 III Performance curve ·GPAXX-6 III Performance curve 20
-
·GPAXX-7 III Performance curve
·GPAXX-7.5 III Performance curve 13.Characteristics 13.1 Description of nameplate 21
-
No
Explanation Maximum mode maximum power Minimum mode minimum power Maximum mode maximum current Current Minimum mode minimum current Maximum pressure-bearing of system (Mpa) Product No. Motor steering Voltage (V) Insulation class Protection Lever Certification mark Frequency (Hz) Temperature grade…
-
14.Technical Parameters and Installation
Dimensions 14.1 Technical data Supply Voltage 220~240V, 50/60Hz Motor Protection Pump does not need external protection Protection Level IP44 Insulation Class H Relative Humidity(RH) Max95% System Load Bearing 1.0 MPa Liquid Temperature Minimum Inlet Pressure ≤+75℃ 0.005 Mpa Suction Inlet Pressure…
-
14.2 Installation Dimensions
-
15.Fault checklist
Warning Before carrying out any maintenance and repair to the electric pump, make sure the power is disconnected and will not be accidentally switched on. Symptom Control Panel Cause Equipment fuse burned Indication lamp “ Off ” Corrective Action Replace the fuse The circuit breaker of current…
-
Product warranty book of Hefei Xinhu
Hefei Xinhu Canned Motor Pump Co., Ltd offers 12 months of quality warranty for its products since the date of sales, and is responsible for product malfunctions or damaged due to manufacturing and material defects. This warranty is valid only when the product is installed strictly in accordance…
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.