Инструкция на Газовые напольные котлы Roca серии G 100
Газовые напольные котлы Roca серии G 100. Инструкция по монтажу и эксплуатации.
Загружаем документ…
Текст инструкции
-
Válvula de seguridad Sicherheitsventil Valvola di sicurezza Safety valve Soupape de sécurité Válvula de segurança 2 18 Ida / Flow / Départ Vorlauf / Mandata / Ida 19 Embudo descarga Discharge funnel Entonnoir de décharge Entlastungstrichter Imbuto di scarico Funil descarga 1 11 Conducir la tubería…
-
Válvula de gas / Gas valve Vanne de gaz / Gasventil Valvola del gas / Válvula de gás 230 V Transductor presión Pressure transducer Transducteur de pression Drucksensor Trasduttore di pressione Transdutor de pressão Termostato de seguridad Limit thermostat Thermostat de sécurité Sicherheitsthermostat…
-
Válvula de gas / Gas valve Vanne de gaz / Gasventil Valvola del gas / Válvula de gás 230 V Circulador A.C.S. / DHW pump Circulateur d’E.C.S. Umwälzpumpe Trinkwarmwasser Pompa di circolazione dell’A.C.S. Circulador de A.Q.S. Termostato de seguridad Limit thermostat Thermostat de sécurité…
-
Características principales / Main features / Principales caractéristiques
Hauptmerkmale / Caratteristiche principali / Características principais Características eléctricas / Electrical data / Caractéristiques électriques / Elektrische Merkmale Caratteristiche elettriche / Características eléctricas 220/230V ~ 50 Hz Potencia útil nominal Nominal Output Puissance nominale…
-
Consumo / Gas Input Rate / Consommation / Verbrauch / Consumo in / Consumo
m3 (st)/h 15 °C – 1013 mbar G 20 G 31 G 30 G 100/30 IE-XIE 3,83 1,47 1,12 G 100/40 IE-XIE 5,20 1,99 1,52 G 100/50 IE-XIE 6,55 2,51 1,91 G 100/30 IE-XIE/GTA 3,83 1,47 1,12 G 100/40 IE-XIE/GTA 5,20 1,99 1,52 Presión máxima de trabajo circuito calefacción: 4 bar. Presión máxima de trabajo circuito…
-
Dimensiones / Dimensions / Dimensions / Abmessungen / Dimensioni / Dimensões
G 100 GTA CONFORT 550 (a) 122 (b) 225 51 (d) 7 77 (e) 1260 1500 (c) 651 47 A (h) Caldera / Boiler Chaudière / Heizkessel Caldaia / Caldeira 8 Cotas / Dim. / Cotes Maße / Quota / Cotas “A” G 100/30 GTA CONFORT 916 G 100/40 GTA CONFORT 1025 – (a): Ida Caldera 1” ext. Boiler flow 1” (m) Départ…
-
GB
Transport and Delivery VERY IMPORTANT: During handling operations and transport of G100 IE-XIE/GTA boilers, the boiler/cylinder assembly must necessarily be in a vertical position. The G100 IE-XIE Confort and G100 IE-XIE/GTA Confort boilers are supplied in a single package, fully factory-assembled…
-
Location of Electrical Connections
and Sensors Figures 10 (G100) and 11 (G100/GTA). Checking Limit Thermostat Operation It is advisable to carry out this check in order to prevent future serious malfunction. This can only be done if no lockout condition exists, that is, under fault code 00 (see “Fault Code” section in the…
-
* One French degree is equivalent to 1 gram of calcium
carbonate per 100 litres of water. – Should it become necessary to add water to the system, wait until the boiler is completely cold before doing so. These boilers are fitted with a safety system that operates based on the improper removal of flue gases, thus causing the gas valve to close. Once the…
-
2-6960-1-0605-CE
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.