TECHNICAL DATA LEAFLET
GAS Low NOx Gulliver BS Series Low NOx One Stage Gas Burners BS1 16 ÷ 52 BS2 35 ÷ 91 kW BS3 65 ÷ 189 kW BS4 110 ÷ 246 kW www.riello.com kW
-
The Riello Gulliver BS series of one stage gas burners, is a complete range of Low NOx emission products, developed to respond to any request for home heating, conforming to the most severe standards regarding the reduction of polluting emissions. This series of burners is available in four…
-
Technical Data
MODEL Burner operation mode Modulation ratio at max. output Servomotor Heat output Working temperature FUEL/AIR DATA G20 gas net calorific value gas density gas delivery G25 gas net calorific value gas density gas delivery LPG gas net calorific value gas density gas delivery Fan Air temperature…
-
Firing Rates
-
Gas train
GAS TRAIN DESIGNATION Series: MB MBC Size: Operation: /1 stage mode opening Leak detection control: Joint type: - 0 R threaded joint F1 square flange BS1 F2 square flange BS2 F3 square flange BS3 - BS4 Electrical connection: SD Standard output pressure range: Domestic plug - without pressure…
-
GAS TRAINS
The burners are set for fuel supply from either the right or left hand sides. Depending on the fuel output and the available pressure in the supply line, you should check the correct gas train to be adapted to the system requirements. The gas train is Multibloc type, containing the main components…
-
Y
-
Pressure Drop Diagram
-
BS3 (NATURAL GAS)
-
GAS TRAIN
-
Ventilation
The different ventilation circuits always ensure low noise levels with high performance of pressure and air delivery, inspite of their compact size. The burners are fitted with an adjustable air pressure switch, conforming to EN 676 standards. Air suction Air pressure switch Combustion Head The…
-
DIMENSIONS OF THE FLAME
-
Operation
BURNER OPERATION MODE Checked Variable All these models are one stage operation. °C bar Output time ON ON OFF OFF time One stage operation Air damper adjustment All Gulliver BS series burners are fitted with a new microprocessor control panel for the supervision during intermittent operation. For…
-
Indication of operation
In normal operation, the various status are indicated in the form of colour codes according to the table. Color code table Operation status Stand-by Diagnosis of fault causes After lock-out has occurred, the red signal lamp is steady on. In this status, the visual fault diagnosis according to the…
-
The MG569 digital control box gives some other advantages
Post ignition (during safety time) The spark ignition is present during all safety time. Adjustable post purge The Post-purge is a function that maintains air ventilation even after the burner is switched off. Post-purge time can be set to a maximum of 6 minutes. This function can be activated and…
-
Emissions
The burners in the Gulliver BS series guarantee controlled combustion, reducing emissions of both CO and NOx, this combustion control is due to the recirculation of the combustion products in the chamber (thanks to different combustible air flow speeds) and to the fuel staging technique (thanks to…
-
Overall Dimensions (mm)
-
Installation Description
Installation, start up and maintenance must be carried out by qualified and skilled personnel. The burner is set in the factory on standard calibration (minimum output). If necessary adjustments can be made on the basis of the maximum output of the boiler. All operations must be performed as…
-
The 7-pole socket is incorporated in the control box, the
6-pole socket for connection to the gas train is already connected to the equipment and fixed to the outside of the burner. The 7-pin plug is also supplied for connection to the boiler. 19
-
Burner accessories
EXTENDED HEAD KIT Burners standard head can be transformed into “extended head” versions by using the special kit. Here the KITS available for the various burners are listed, showing the original and the extended lengths. BURNER BS1 STANDARD HEAD LENGTH (mm) 70 ÷ 116 EXTENDED HEAD LENGTH (mm) 70 ÷…
-
LPG KIT
For burning LPG gas, a special kit is available to be fitted to the combustion head on the burner, as shown in the following table. BURNER HEAD CODE CODE (*) BS1 3001003 3002734 BS2 3001004 3002735 BS3 3001005 3002736 BS4 3001011 3002737 (*) CE certification in progress TOWN GAS KIT For burning Town…
-
Gas train accessory
SEAL CONTROL KIT To test the valve seals on the gas train a special “seal control kit” is available. 22 GAS TRAIN CODE for 50Hz operation CODE for 60Hz operation MB/1 type 3010123 20050030
-
Specification
DESIGNATION OF SERIES A specific index guides your choice of burner from the various models available in the BS series. Below is a clear and detailed specification description of the product. Series: B Low NOx burners R Standard emission burner Fuel: S Natural Gas SP LPG G Light oil Size: Optional…
-
SPECIFICATION
STATE OF SUPPLY Burner Monoblock, gas burners, completely automatic, one stage operation, made up of: - fan with forward curve blades - cover lined with sound-proofing material - air damper, completely closed in stand by, with external adjustment, with no need to remove the cover - single phase…
-
Riello Burners a world of experience in every burner. high efficiency burner technology. With burner capacity from 5 kW to 48 MW, Riello gas, oil, dual fuel and Low Nox burners deliver unbeatable performance across the full range of residential and commercial heating applications, as well as in…