installation — operation — maintenance
instructions HP18 SERIES UNITS 1-1/2 through 5 ton HEAT PUMP 501,823M 7/85 Supersedes 7/84 LEi "АИ, NM OX industries Inc. Litho U.S.A. UNIT DIMENSIONS MODEL NO. A c D G HP18-211 HP18-261 НР18-311 НР18-410 28-3/4 т. {730тт} 22-1/4 in. (565mm) 3-5/8 in. (92mm) 7-1/2 in. (191mm) 3-5/8 in. {92mm) 15 in.…
-
INSTALLATION
PACKAGE 1 OF 1 CONTAINS 1 - Assembled Unit Check unit for shipping damage. Consult last carrier immediately if damage is found. These instructions are intended as a general guide and do not supersede local codes. Authorities having jurisdiction should be consulted before installation. INSTALLATION…
-
ELECTRICAL
Wiring must conform to the National Electric Code (NEC) and local codes. Application diagrams are included in this instruction and in indoor unit instructions. Refer to unit rating plate for minimum circuit ampacity and max- imum fuse size. 1 - Provide line voltage power supply to unit from а…
-
REFRIGERATION
PROCESSING PROCEDURE The unit is factory charged with the amount of R-22 refrigerant indicated on the unit rating plate. This charge is based on a matching indoor coil and outdoor coil with a 25 ft. (7620mm) line set. For varying lengths of line set, refer to table for refrigerant charge adjustment.…
-
REFRIGERATION
5 OPENING CAP If weighing facilities are not available or if unit is just low on charge, use the following procedure: 1 - Connect gauge manifold as shown on Page 6 “Gauge Manifold Connections.’’ Connect an upright R-22 drum to center port of gauge manifold. 2 - Set room thermostat to 74°F (23°C) in…
-
Use gauge ports on vapor tine valve and liquid valve
for evacuating refrigerant lines and indoor coil. EXPANSION VALVE ( \ HIGH SUCTION PRESSURE В — > GAUGE MANIFOLD + ee HIGH PRESS. y OUTDOOR COIL OUTDOOR COIL =z SWITCH WITH INTERNAL VALVE CHECK VALVE FILTER DRIER + $ REVERSING DRUM DISCHARGE MUFFLER | J par REFRIGERANT J) 7) COMPRESSOR . . INDOOR…
-
OPERATION
HIGH PRESSURE SWITCH All units are equipped with a high pressure switch (manual reset type) mounted on the compressor discharge line. This switch has a “cut-out” point of 410 psig (2827 kPa) and must be manually reset when discharge pressure drops below 180 psig (1241 kPa). CRANKCASE HEATER…