Тепловые насосы Lennox серии HP 20. Инструкция по монтажу, эксплуатации и техническому обслуживанию.
Смотрите также: Основной документ →
Загружаем документ…
Текст инструкции
-
HP20 Series Units
HEAT PUMP UNITS 502 ,394M 10/89 Supersedes 502,311M Litho U.S.A RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE LENNOX tndustet0s inc
-
TABLE OF CONTENTS
Unit Dimensions.. Installation Electrical CONM@CTIONS чении тяни нии нии EEA DERE OnE EE en enn сни вузу лик Page 3 Plumbing Refrigeration Start-Up and Adjustments Operation Maintenance UNIT DIMENSIONS DISCHARGE АЯ INLET AIR [teeninarenrnsome В B FAN GUARD MANE { INLET AIR SUCTION cauce | И ПИ lim A…
-
|-SHIPPING AND PACKING LIST
Package 1 of 1 contains: 1-Assembled heat pump unit Check unit for shipping damage. Consult last carrier immediately if damage is found. These instructions are intended as a general guide and do not supersede local codes in any way. Authorities having jurisdiction should be consulted before…
-
ROOFTOP APPLICATION
WIND BARRIER CONSTRUCTION PREVAILING WINTER WINDS Vv WIND BARRIER INLET AIR INLET АА INLET АВ INLET AIR FIGURE 3 1И-ЕСЕСТЕСАЕ CONNECTIONS (Figure 4) Wiring must conform with the National Electric Code (NEC) and local codes. An application diagram is included in this instruction and in indoor unit…
-
IV-PLUMBING
Field refrigerant piping consists of liquid and vapor lines from the outdoor unit (sweat connections). Use Lennox [10 series line sets as shown in table 1 or use field-fabricated refrigerant lines. Refer to the piping section of the Lennox Unit Information Service manual for proper size, type and…
-
TABLE 2
Line Set Dla. Ozs. per ft. (ml per mm) adjust Vapor | Liquid from 25 ft. (7620 mm) line set* 5/8 ш. | 5/16 In. 1/2 ounce (16mm) | (8mm) (145ml) 5/8 т. | 3/8 In. 1 ounce (16mm) | (10mm) (30ml) 3/4 т. | 3/8 In. 1 ounce (19mm) | (10mm) (30ml) 7/8 т. | 3/8 In. 1 ounce {22mm} | (10mm) (30ml) 1-1/8 ш.|…
-
HP20 COOLING CYCLE (SHOWING GAUGE MANIFOLD CONNECTIONS)
DEFROST PRESSURE + SWITCH KN ” DEFROST THERMOSTAT EXPANSION VALVE FILTER / DRIER OUTDOOR COIL WITH INTERNAL CHECK VALVE + STRAINER 4 > | REVERSING VALVE HIGH LIQUID SUGIION PRESSURE . име 9 ICE COMPRESSO! PORT | ¥ vee Qi« {issuer MANIFOLD | SUCTION [3 INDOOR aa" e SERVICE UNIT. PORT VAPOR то LINE…
-
B-Charging
The following charging procedure is intended as a general guide. It is intended for use on expansion valve systems only. For best results, indoor temperature should be between 70°F and 80°F. Be sure to monitor system pressures while charging. Charging should be done in cooling mode. If the system is…
-
А subcooling temperature less than the value given in table 5 indicates an undercharge. Add геfrigerant slowly and continue to watch liquid line temperature until subcooling temperature approximates the value given in table 5. A subcooling temperature greater than the value given in table 5…
-
VIN-MAINTENANCE
At the beginning of each heating or cooling season, the system should be cleaned as follows: A-Heat Pump Unit 1- 2- Clean and inspect condenser coil (may be flushed with a water hose). Condenser fan motor is prelubricated and sealed. Always relubricate motor according to the instructions on the…