AmaCan D NEMA Installation/Operating Manual Mat. No.: 05157010
-
Legal information/Copyright
Installation/Operating Manual AmaCan D Original operating manual All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without the…
-
Glossary
Glossary Certificate of decontamination If a product is to be returned to the manufacturer, the customer declares in a certificate of decontamination that the product has been properly drained to eliminate any environmental and health hazards arising from components in contact with the fluid…
-
1 General
1 General 1.1 Principles This operating manual is valid for the type series and variants indicated on the front cover. The manual describes the proper and safe use of this equipment in all phases of operation. The name plate indicates the type series and size, the main operating data, the order…
-
1 General
1.6 Key to safety symbols/markings Table 3: Definition of safety symbols/markings Symbol Description ! DANGER DANGER This signal word indicates a high-risk hazard which, if not avoided, will result in death or serious injury. ! WARNING WARNING This signal word indicates a medium-risk hazard which…
-
DANGER All the information contained in this section refers to hazardous situations. In addition to the present general safety information the action-related safety information given in the other sections must be observed. 2.1 General ▪ This operating manual contains general installation, operating…
-
2.4 Consequences and risks caused by non-compliance with these operating
instructions ▪ Non-compliance with these operating instructions will lead to forfeiture of warranty cover and of any and all rights to claims for damages. ▪ Non-compliance can, for example, have the following consequences: – Hazards to persons due to electrical, thermal, mechanical and chemical…
-
▪ When taking the pump set out of service always adhere to the procedure
described in the manual. (ð Section 6.3, Page 52) ▪ Decontaminate pumps which handle fluids posing a health hazard. (ð Section 7.3.2, Page 61) ▪ As soon as the work has been completed, re-install and re-activate any safetyrelevant devices and protective devices. Before returning the product to…
-
3.1 Checking the condition upon delivery
1. On transfer of goods, check each packaging unit for damage. 2. In the event of in-transit damage, assess the exact damage, document it and notify KSB or the distributor and the insurance company about the damage in writing immediately. 3.2 Transport DANGER Improper transport Danger to life from…
-
Placing the pump set on unsecured and uneven surfaces
Personal injury and damage to property! ▷ Always place the pump set on a solid and level surface with the pump set in a vertical position and the motor on top. ▷ Only place the pump set on a surface of sufficient load-carrying capacity. ▷ Use appropriate means to secure the pump set against tilting…
-
Fig. 2: Pulling the pump set upright with one crane
Fig. 3: Pulling the pump set upright with two cranes ü Suitable lifting equipment (e.g. crane) has been selected. 1. a) If using one piece of lifting equipment: Attach the crane hook to the bail of the pump set. b) If using two pieces of lifting equipment: Attach the crane hook of one crane to the…
-
Incorrect handling of the electric cable
Personal injury and damage to property! ▷ Secure electric cables against falling down. ▷ Avoid electric cables being laid on surfaces without fastening. ▷ When moving the pump set keep at a safe distance to the electric cables. WARNING Improper lifting/moving of heavy assemblies or components…
-
Pump set tilting
Risk of squashing hands and feet! ▷ Suspend or support the pump set. CAUTION Improper storage Damage to the electric cables! ▷ Support the electric cables at the cable entry to prevent permanent deformation. ▷ Only remove the protective caps from the electric cables at the time of installation.…
-
4. Always complete and enclose a certificate of decontamination when returning
the pump. Indicate any safety measures and decontamination measures taken. (ð Section 10, Page 174) NOTE If required, a blank certificate of decontamination can be downloaded from the KSB web site at: www.ksb.com/certificate_of_decontamination 3.5 Disposal WARNING Fluids handled, consumables and…
-
4.1 General description
▪ Submersible pump in discharge tube Pump set for handling river water and stormwater, pre-screened domestic and industrial waste water as well as activated sludge 4.2 Designation Example: AmaCan DB3 600-420 / 130 4 UTG1 IE3 Table 5: Designation key Code Description AmaCan Type series D Impeller…
-
4.3 Name plate
b) a) KSB SE & Co. KGaA KSB SE & Co. KGaA Johann-Klein-Straße 9 67227 Frankenthal Johann-Klein-Straße 9 67227 Frankenthal Germany TYPE Amacan DB3 600-420 / 130 4 UT G1 IE3 No. 9971xxxx43/000100 MADE IN GERMANY Q 7820 US.gpm H 16 ft 2023 TEMP. MAX. 104°F 3430 lbs 12345678910-ABCDE MOTOR IP 68 SUBM.…
-
Bearings
▪ Grease-packed rolling element bearings Monitoring equipment Various sensor packages are available for pump/pump set monitoring: ▪ Basic – Motor temperature monitoring (PTC thermistor) – Leakage sensor in the motor space – Mechanical seal leakage sensor (float switch) – Bearing temperature…
-
Overflow design with open intake
chamber Design with underfloor discharge line Design with above floor disfor installation in open intake chamber charge nozzle for installation in open intake chamber BG5) discharge tube CG5) discharge tube DG5) discharge tube Overflow design for installation in cov- Design with underfloor discharge…
-
Design The pump is designed with an axial fluid inlet and an axial outlet. The hydraulic
system sits on the extended motor shaft. The shaft runs in common bearings. Function The fluid enters the pump axially via a suction nozzle (bellmouth) (1) and is accelerated in a rotating flow by the rotating impeller (2). The required energy is transmitted from the electric motor (4) to the…
-
5.1 Safety regulations
DANGER Improper installation in potentially explosive atmospheres Damage to the pump set! ▷ Comply with the applicable local explosion protection regulations. ▷ Observe the information given in the data sheet and on the pump/motor name plates. DANGER Improper transport Danger to life from falling…
-
When such materials are used in potentially explosive atmospheres, a systematic
electrostatic charging mechanism has to be ruled out. If the system design and its inherent boundary conditions are such that a foreseeable electrostatic charging mechanism is created, using lifting ropes and/or plastic components with low electrical conductivity is impermissible in potentially…
-
Table 7: Key to the symbols
Symbol FD Key Always apply a liquid sealant (e.g. Hylomar SQ32M) to sealing surfaces marked with this symbol. 1. Place the pump set down in a horizontal position. Secure it against rolling away. (ð Section 3.2.2, Page 12) 2. When placing it down, make sure that screw plug 903.04 is on top. ð Screw…
-
Hands and/or foreign objects in the pump casing
Risk of injuries, damage to the pump! ▷ Never insert your hands or any other objects into the pump. ▷ Check that the inside of the pump is free from any foreign objects. ▷ Verify that the transport lock has been removed. ▷ Take suitable precautions (e.g. wear safety goggles). CAUTION Pump set…
-
5.3 Lowering the pump set into the discharge tube
DANGER Improper transport Danger to life from falling parts! Damage to the pump set! ▷ Use the attachment point provided for attaching the lifting accessory. ▷ Never lift the pump set by the electric cables. ▷ Use the lifting chain/rope included in the scope of supply exclusively for lowering or…
-
5.3.1 Information for correct installation
The flow-straightening vane is indispensable for the inlet conditions of the pump set. It prevents the development of a submerged vortex (floor vortex) which could cause a drop in performance, for example. For optimum inlet conditions observe the following information: 1. 1 Observe the structural…
-
Refer to and comply with the general arrangement drawing/outline drawing when
installing the pump set. 412.05 112 Fig. 10: Inserting the O-ring 1. If not already fitted, insert the supplied O-ring 412.05 into pump bowl 112. 2. Attach the crane hook to the bail of the pump set. 3. Center the pump set above the discharge tube. Slowly lower the pump set into the discharge tube…
-
Pump set drops during the installation or removal process
Personal injury and damage to property! ▷ Never use the turnbuckle, shackle or discharge tube cover to lift the pump set. ▷ Always use lifting lug 59-47. NOTE Prior to fitting the turnbuckle, check that the corresponding split pin has not been cracked and/or chipped. If damaged, always use a new…
-
7. Lower the pump set into the discharge tube until the bail is in an accessible
position, protruding from the discharge tube, and the pump set is suspended from the lifting rope (1). 8. Securely cover the discharge tube except for a gap which allows work to continue. 9. Unclip the crane hook (3) of the lifting equipment from the bail. Move the lifting equipment up higher. Fig.…
-
Fig. 18: Installation information for the cable clamps
15. Attach the crane hook (1) to the lifting lug (6) suspended from the lifting rope. 16. Attach the lifting rope to the next lifting lug. 17. Progressively lower the pump set into the discharge tube. ð Secure the cable bundle with evenly spaced sheathed cable clamps until the pump set is suspended…
-
Fig. 20: Shackle/turnbuckle
23. Tighten the turnbuckle until the cable bundle is tight but does not lift the pump set off its seat. 24. Secure the turnbuckle against loosening with two locknuts. 25. Unclip the crane hook of the lifting equipment from the lifting lug. Free the power cables from the manila rope and route them to…
-
NOTE
Prior to fitting the turnbuckle, check that the corresponding split pin has not been cracked and/or chipped. If damaged, always use a new split pin. ü One piece of suitably sized lifting equipment with at least two fastening points or two suitably sized pieces of lifting equipment are available. ü…
-
7 8 Fig. 24: Securing the power cable and sensor cable 10. Secure the sensor cable (7) and power cables (8) to the crane hook (3) of the lifting equipment with a manila rope (9). 11. Trim the spacer (a) to fit between the two ferrules. ð If a support is used in this section, adjust the spacer (a)…
-
Fig. 27: Installation information for the cable clamps
X 59-7 733.05 719.05 X 81-51 (185, 81-39) 59-4 733.05 719.05 Fig. 28: Support rope with support Table 8: Key to the symbols Symbol L 243 Key Always secure screwed connections marked with this symbol with Loctite 243. 15. Undo the screwed connection at clamping element 81-51. 16. Place clamp 81-39 of…
-
Fig. 29: Spacer at support
19. Guide the power cables and sensor cable along the support to the next cable clamp. Pull them taut and secure them with the clamp. ð If several supports are fitted, arrange the supports offset from each other by 90°. 20. Attach the crane hook (1) to the lifting lug (6) suspended from the lifting…
-
26. Attach the support rope with shackle and turnbuckle to a suspension loop
(provided in the discharge tube or structure). 27. Secure the turnbuckle with a split pin. ð Insert the split pin. Bend back the two legs of the split pin in opposite directions. ð Attach the shackle of the turnbuckle to the upper thimble of the support rope. Do not attach the turnbuckle to the…
-
After start-up of the pump, a soft starter must always be bypassed
5.4.1.2 Setting the overload protection device 1. Protect the pump set against overloading by a thermal time-lag overload protection device in accordance with IEC 60947 and local regulations. 2. Set the overload protection device to the rated current specified on the name plate. (ð Section 4.3, Page…
-
Setting Observe the following instructions for setting a frequency inverter
▪ Set the current limit to max. 1.2 times the rated current. The rated current is indicated on the name plate. Start-up Observe the following instructions for starting up a frequency inverter: ▪ Ensure short start ramps (maximum 5 seconds). ▪ Only start speed-controlled operation after 2 minutes at…
-
Fig. 32: Sensor positions Table 9: Overview of sensors Position Sensor Basic Basic+ 1 Leakage sensor in the motor space ✘ ✘ 2 Bearing temperature monitoring, motor end (Pt100) - ✘ 3 Mechanical seal leakage sensor (float switch) ✘ ✘ 4 Motor temperature monitoring (PTC thermistor) ✘ ✘ 5 Bearing…
-
CAUTION
Temperature monitoring equipment not properly connected Winding damage! ▷ Never use the Pt100 resistance thermometers as a sole means of monitoring the motor temperature. 5.4.1.5.1.2 Leakage inside the motor DANGER Incorrect monitoring of leakage electrode Explosion hazard! Danger of death from…
-
5.4.1.5.1.3 Mechanical seal leakage
The chamber for mechanical seal leakage is equipped with a float switch (core identification 3 and 4). The contact (maximum 250 V~/2 A) opens when leakage is detected in the leakage chamber. Opening of the contact shall trigger an alarm signal. 5.4.1.5.1.4 Bearing temperature Fig. 35: Float switch…
-
Fig. 36: Sensor positions Table 10: Overview of sensors (pump set with sensor system) Pos. Sensor Sensor type for motor size Up to 215 4, 205 6, 160 8 From 275 4, 250 6, Leakage sensor in the motor space Conductive Conductive 2 Bearing temperature monitoring, motor end 1 × Pt100 1 × Pt100 3 Leakage…
-
Table 11: Overview, warning values and trip values for AmaCan D
Sensor Warning Tripping Temperature 1 (Pt100 temperature sensor, bearing) 266 °F [130 °C] 302 °F [150 °C] Temperature 3 (Pt100 temperature sensor, motor) None None Motor temperature PTC - Not parameterizable Leakage 1 (leakage sensor in the motor) - < 60 kΩ Leakage 2 (mechanical seal leakage sensor…
-
Operating an incompletely connected pump set
Damage to the pump set! ▷ Never start up a pump set with incompletely connected power cables or nonoperational monitoring devices. DANGER Using damaged power cables Danger of death from electric shock! ▷ Never connect damaged power cables. ▷ Visually inspect the power cable before connecting it. ▷…
-
Touching the pump set during operation
Electric shock! 1581.86/03-EN-US ▷ Make sure that the pump set cannot be touched during operation. AmaCan D 47 of 176
-
6.1 Commissioning/start-up
6.1.1 Prerequisites for commissioning/start-up DANGER Operating the pump set without protective equipment Electric shock! Risk of injury! Danger of death from drowning! ▷ Never start up the pump set without special protective equipment when there are persons in the tank. ▷ If persons come into…
-
6.1.2 Start-up
DANGER Operating the pump set without protective equipment Electric shock! Risk of injury! Danger of death from drowning! ▷ Never start up the pump set without special protective equipment when there are persons in the tank. ▷ If persons come into contact with the fluid handled during pump operation…
-
The maximum permissible deviation in supply voltage is ±10 % of the rated voltage
The voltage difference between the individual phases must not exceed 1 %. 6.2.2 Frequency of starts CAUTION Excessive frequency of starts Damage to the motor! ▷ Never exceed the specified frequency of starts. To prevent high temperature increases in the motor and excessive loads on the motor…
-
6.2.4.2 Density of the fluid handled
CAUTION Impermissibly high density of fluid handled Motor overload! ▷ Observe the information on fluid density in the data sheet. ▷ Make sure the motor has sufficient power reserves. The power input of the pump set changes in proportion to the density of the fluid handled. 6.2.4.3 Minimum level of…
-
6.3 Shutdown/storage/preservation
6.3.1 Shutdown CAUTION Uncontrolled backflow of the fluid from the riser Damage to the pump set! ▷ Prevent any uncontrolled backflow of the fluid handled with suitable means. ▷ Control the fluid backflow, e.g. by throttling the gate valve in the discharge line. 6.3.2 Measures to be taken for…
-
The pump (set) is removed from the pipe and stored
ü All safety regulations are observed. 1. Clean the pump set. 2. Preserve the pump set. 6.4 Returning to service WARNING Failure to re-install or re-activate protective equipment/devices Risk of personal injury from moving parts or escaping fluid! ▷ As soon as the work is completed, re-install…
-
7.1 Safety regulations
The operator ensures that all maintenance, all inspections and all installation work is performed by authorized, qualified specialist personnel who are thoroughly familiar with the manual. DANGER Sparks produced during maintenance work Explosion hazard! ▷ Observe the safety regulations in force at…
-
Risk of falling when working at great heights
Danger to life by falling from great heights! ▷ Do not step onto the pump (set) during installation work or dismantling work. ▷ Pay attention to safety equipment, such as railings, covers, barriers, etc. ▷ Observe the applicable local occupational safety regulations and accident prevention…
-
Insufficient stability
Risk of crushing hands and feet! ▷ During assembly/dismantling, secure the pump (set)/pump parts against tilting or tipping over. WARNING Corrosion on the pump set Risk of injury from solid matter in the fluid handled! ▷ If persons come into contact with the fluid handled during pump operation (e.g.…
-
Maintenance interval
Maintenance work ▪ Every 24,000 h For a pump set in material variant G3 replace (ð Section 7.8, Page 90) the sacrificial anode if this has not already been done as part of a previous inspection. ▪ At least every 5 years For details see General overhaul 7.2.1 Inspection work 7.2.1.1 Measuring the…
-
Temperature sensors in the Table 13: Resistance measurement
motor winding Measurement between terminals Resistance [Ω] 10 and 11 200 - 1000 7) 100 - 120 33 and 34 7) 100 - 120 7) 100 - 120 31 and 32 35 and 36 If the specified tolerances are exceeded, disconnect the connection cable at the pump set and repeat the check inside the motor. If the tolerances are…
-
Temperature sensors at the Table 17: Resistance measurement of the temperature sensors at the motor winding motor winding Display at AmaControl Check with ohmmeter Resistance Sensor Measurement between cores [Ω] Motor temperature - PTC 10 and 11 100 to 1000 Temperature 3 - Pt100 31 and 32 100 to 120…
-
Incorrect handling of the electric cable
Personal injury and damage to property! ▷ Secure electric cables against falling down. ▷ Avoid electric cables being laid on surfaces without fastening. ▷ When moving the pump set keep at a safe distance to the electric cables. WARNING People falling into the unsecured discharge tube Risk of…
-
Pump set tilting
Risk of squashing hands and feet! ▷ Suspend or support the pump set. CAUTION Improper storage Damage to the power cables! ▷ Support the power cables at the cable entry to prevent permanent deformation. ▷ Protect the core ends against humidity. 12. Do not disconnect the pump set from the hook of the…
-
7.3.5 Checking the ground conductor
1. Measure the resistance between ground conductor and housing. The resistance must be lower than 1 Ω. 2. Replace any damaged components by original spare parts. DANGER Defective ground conductor Electric shock! ▷ Never switch on a pump set with a defective ground conductor. 7.3.6 Checking the…
-
ü The pump set is positioned horizontally on a level surface and is protected
against rolling away. 1. Place the container underneath screw plug 903.02. 2. Remove screw plug 903.02 and joint ring 411.02. 3. Screw in a sufficiently long tube (1) with G 1/2 thread. 4. Carefully rotate the pump set until the opening of the leakage chamber points downwards. ð If there is no…
-
Contamination of fluid handled by lubricant
Hazard to persons and the environment! ▷ Using machine oil is only permitted if the oil is disposed of properly. 7.4.1.3 Lubricant quantity Table 23: Lubricant quantity Pump size 600 - 390 Motor size Lubricant quantity [quart] [l] 1,6 1,5 1,5 1,4 1,6 1,5 1,5 1,4 47 6 ...120 6 1,5 1,4 2,3 2,2…
-
Improper handling when placing the pump set in a vertical/horizontal position
Personal injury and damage to property! ▷ Select suitable lifting equipment for the size of the pump. ▷ Use appropriate means to secure the pump set against tilting, tipping over or rolling off. ▷ Maintain a safe distance during lifting operations (load may swing when being lifted). ▷ Use additional…
-
7.4.1.4.2 Filling in the lubricant
903.04 903.01 411.01 FD Fig. 41: Filling in the lubricant Table 25: Key to the symbols Symbol FD Key Always apply a liquid sealant (e.g. Hylomar SQ32M) to sealing surfaces marked with this symbol. ü Screw plug 903.06 has been screwed in with joint ring 411.06. ü The pump set has been placed in a…
-
7.4.2.2 Grease quality
CAUTION Mix of different grease types Damage to the pump set! ▷ Make sure to use the right type of grease. ▷ Never mix different types of grease. The following greases can be used to lubricate the rolling element bearings: Table 26: Lubricant characteristics Base oil Ester oil Type A Thickener NLGI…
-
7.5 Dismantling the pump set
7.5.1 General information/Safety regulations DANGER Improper transport Danger to life from falling parts! Damage to the pump set! ▷ Use the attachment point provided (eyebolt, lifting lug or bail) for attaching lifting accessories. ▷ Never suspend the pump set by its power cable. ▷ Never use the…
-
Components with sharp edges
Risk of cutting or shearing injuries! ▷ Always use appropriate caution for installation and dismantling work. ▷ Wear work gloves. WARNING Pump set tilting or rolling off Risk of personal injury! ▷ Make sure the pump set is secured against tilting during the entire dismantling process. ▷ For…
-
3. Place the pump set down in a horizontal position on wooden supports. Secure it
against rolling away. 4. Remove nuts 920.10 from studs 902.10. Store them carefully. 7.5.4 Removing the impeller 7.5.4.1 Overview of impeller design For removing/fitting the impeller a difference is made between impeller with tapered fit and impeller with cylindrical fit. Table 28: Combinations Pump…
-
7.5.4.2 Removing an impeller with tapered fit
904.59* 230 914.10 930.10 210 Fig. 43: Removing the impeller with tapered fit * Does not apply to sizes 600-390, 700-390, 600-420 and 700-420. ü The pump set has been placed in a horizontal position on wooden supports. It has been secured against rolling away. ü The lubricant and any leakage have…
-
2. Undo hexagon socket head cap screw 914.10. Remove it together with lock
washer 930.10. 3. Pull impeller 230 off shaft 210. 4. Remove key 940.02 from shaft 210. Store it carefully. 7.5.5 Removing the mechanical seal 7.5.5.1 Impeller-end mechanical seal 433.02 550.44 932.44 210 Fig. 45: Removing the impeller-end mechanical seal ü The pump set has been placed in a…
-
433.01 112 932.03 350 914.02 818 80-1 571 210 Fig. 46: Removing the drive-end mechanical seal Table 29: Key to the symbols Symbol L 243 Key Always secure screwed connections marked with this symbol with Loctite 243. ü The impeller-end mechanical seal has been removed. 1. Attach the pump set to bail…
-
7.5.6.1 Removing the motor housing cover
Pump set with standard sensors 571 914.01 A-A 81-2 A A 903.51 812 Fig. 47: Removing the motor housing cover, pump set with standard sensors ü Suitable lifting equipment is available. ü The pump set has been disconnected from the power supply. It has been securely placed on a level/even surface in a…
-
Pump set with sensor system
571 914.01 A-A 81-17 A A 903.51 835 812 Fig. 48: Removing the motor housing cover, pump set with sensor system ü Suitable lifting equipment is available. ü The pump set has been disconnected from the power supply. It has been securely placed on a level/even surface in a vertical position. 1. Attach…
-
7.5.6.2 Dismantling the cable gland with connection cable
571 68-3.02 (82-11) 81-18.03 A-A 914.05 834.01 A 901.20 932.20 A 812 834.02 914.04 Fig. 49: Removing the cables and cable gland Removing the power cable 81-29.03 ü The motor housing cover has been removed, placed down and secured against rolling away. 1. Remove cover plate 82-11 or 68-3.02 from bail…
-
Improper lifting/moving/transporting of heavy assemblies or components
Danger to life from falling parts! Damage to the pump set! ▷ Never rotate the rotor in the motor housing during dismantling/reassembly. ▷ Place the motor (unit) including rotor and bearing housing on a wooden support and protect it against rolling off. WARNING Improper lifting/moving of heavy…
-
NOTE
Before reassembling the motor section, check that all joints relevant to explosion protection (flamepaths) are undamaged. Components with damaged flamepaths must be replaced. Only use original spare parts made by KSB for explosion-proof submersible mixer drives. The flamepaths are shown in the…
-
4. Insert cable gland 834.02 with the sensor cable and O-ring 412.08 into the
opening provided. 5. Fasten cable gland 834.02 with hexagon socket head cap screws 914.05 and secure the screwed connection with Loctite 243. Pump set with sensor system ü The motor housing cover has been removed, placed down and protected against rolling away. 1. Adjust the lengths of the cable…
-
ð Lower motor housing cover 812 down onto motor housing 811 or motor unit
80-1 until only a gap remains which allows work to continue. ð Watch the alignment grooves in motor housing cover 812 and motor housing 811. The alignment grooves must be properly aligned. 2. Connect plug 81-2 of the sensor cable to the corresponding connector. 3. Connect the cores of the power…
-
ð Watch the alignment grooves in motor housing cover 812 and motor housing
811. The alignment grooves must be properly aligned. 6. Fasten motor housing cover 812 to motor housing 811 or motor unit 80-1 with socket head cap screws 914.01. Secure with Loctite 243. Observe the tightening torque. 7. Cover the jacking threads with caps 903.51. 8. Perform a leak test on the…
-
Table 33: Key to the symbols
Symbol L 243 Key Always secure screwed connections marked with this symbol with Loctite 243. ü The pump set has been positioned horizontally on suitable wooden supports and is secured against rolling away. 1. Use an assembling sleeve of a suitable diameter to insert the mating ring of mechanical…
-
2. Carefully guide on the bellows part of the mechanical seal until it rests against
the mating ring. 3. Slide disc 550.44 and circlip 932.44 onto the shaft. Press the circlip in with an assembly sleeve until the circlip is axially fastened in the shaft groove. ð If, unlike in the illustration, a HJ97G mechanical seal has been fitted, also tighten the grub screws at the mechanical…
-
7.6.5.2 Fitting the impeller with tapered fit
904.59* 230 914.10 930.10 210 Fig. 55: Fitting the impeller with tapered fit * Does not apply to sizes 600-390, 700-390, 600-420 and 700-420. Table 35: Key to the symbols Symbol L 243 Key Always secure screwed connections marked with this symbol with Loctite 243. ü The pump set has been placed in a…
-
7.6.5.3 Fitting the impeller with cylindrical fit
904.59* 230 940.02 914.10 930.10 210 Fig. 56: Fitting the impeller with cylindrical fit * Does not apply to sizes 600-390, 700-390, 600-420 and 700-420. Table 36: Key to the symbols Symbol L 243 Key Always secure screwed connections marked with this symbol with Loctite 243. ü The pump set has been…
-
ð As an alignment aid, one or several studs can be screwed into the tapped
blind holes of pump bowl 112. 4. Fully lower the pump set onto casing wear ring 502. 5. Screw in all socket head cap screws 914.12. Only tighten them lightly. 6. Lift the pump set off bellmouth 138. Place it down in a horizontal position on suitable wooden supports. Secure it against rolling away.…
-
ð If clearance A is too large, loosen all hexagon socket head cap screws 914.24
evenly and, at the same time, tighten hexagon socket head cap screws 914.12 evenly. 4. Measure clearance A between impeller vane and casing wear ring at the vane trailing edge of the impeller with a feeler gage. The remaining clearance should not be smaller than 0.15 mm in any place. 5. When…
-
ü Bellmouth 138 has been positioned on wooden supports on a level/even and
solid surface. ü Suitable lifting equipment is available. ü The pump set has been completely pre-assembled. 1. Attach the pump set to bail 571 and pull it upright. 2. Center the pump set above bellmouth 138. ð Verify that the alignment grooves are properly aligned. 3. Slowly lower the pump set. ð…
-
411.31 L 243 FD Fig. 60: Leak testing the motor Table 40: Key to the symbols Symbol Key L 243 Always secure screwed connections marked with this symbol with Loctite 243. FD Always apply a liquid sealant (e.g. Hylomar SQ32M) to sealing surfaces marked with this symbol. 1. Undo and remove screw plug…
-
7.8 Replacing the sacrificial anode
7.8.1 Interval On pump sets with sacrificial anodes (material variant G3), the sacrificial anodes must initially be checked after 6 months. If necessary, the sacrificial anodes must be replaced. ▪ If the sacrificial anodes show little wear, the maintenance interval can be extended to 12 months. ▪…
-
7.8.3 Replacing the sacrificial anodes at the bellmouth
99-16.02 Pos. Y 99-16.01 Pos. X Fig. 62: Sacrificial anodes at the bellmouth ▪ Information on position X: Distribute the number of sacrificial anodes on both sides of the vanes. The stays for welding on may be shortened. ▪ Information on position Y: Evenly distribute the number of sacrificial anodes…
-
7.8.4 Replacing the sacrificial anodes at the pump bowl
A B 99-16.05 Pos. Y A-A 99-16.04 Pos. Z B 99-16.04 Pos. X A Fig. 63: Sacrificial anodes at the pump bowl ▪ Information on position X: Distribute the number of sacrificial anodes on both sides of the vanes. The stays for welding on may be shortened. ▪ Information on position Y: Evenly distribute the…
-
Steel grade
- A2, A4 A2, A4 C3 Property class 8.8 -50 -70 -80 Thread Minimum Rated value Minimum Rated value Minimum Rated value Minimum 1.4410 1.4462 Rp0,2 ≥ 530 N/mm2 Rp0,2 ≥ 450 N/mm2 Rated value Minimum Rated value Minimum Rated value M27 M30 1035 1150 1035 1150 M33 1393 1547 1088 1393 1547 1153 1281 977…
-
Also supply the following data
▪ Part No. and description ▪ Quantity of spare parts ▪ Shipping address ▪ Mode of dispatch (freight, mail, express freight, air freight) 7.10.2 Recommended spare parts stock for 2 years' operation to DIN 24296 Table 46: Quantity of spare parts for recommended spare parts stock Part No. Description…
-
8 Trouble-shooting
8 Trouble-shooting WARNING Improper remedial work Risk of personal injury! ▷ For any work performed in order to remedy faults observe the relevant information given in this operating manual and/or the product literature provided by the accessories manufacturers. If problems occur that are not…
-
8 Trouble-shooting
A B C D E Possible cause Remedy11) - - - - Mechanical seal monitor has tripped. Have cause determined and eliminated by qualified and trained personnel. ✘ - - - - Bearing temperature monitor has tripped. Have cause determined and eliminated by qualified and trained personnel. 1581.86/03-EN-US ✘ 96…
-
9.1 General assembly drawing with list of components
-
Table 48: Key to the symbols
Symbol Key FD Always apply a liquid sealant (e.g. Hylomar SQ32M) to sealing surfaces marked with this symbol. L 243 Always secure screwed connections marked with this symbol with Loctite 243. Table 49: List of components Description Part No. Description 112 Pump bowl 502 Casing wear ring 138…
-
9.2.2 Bearing temperature sensors
Bearing temperature sensor, motor end, sensor package Basic+ or Premium 69-6.01 520.01 Fig. 67: Bearing temperature sensor, motor end Table 54: List of components Part No. Description Part No. Description 520.01 Sleeve 69-6.01 Temperature sensor Bearing temperature sensor, pump end 69-6.02 520.02…
-
Table 58: List of components
Description Part No. Description 320 Rolling element bearing 500.02 Ring 321 Radial ball bearing 504.02 Spacer ring 412.57 O-ring 932.02 Circlip 421.02 Lip seal 950.02 Spring 484.02 Spring plate 1581.86/03-EN-US Part No. AmaCan D 103 of 176
-
9.2.4 Sensors, bearing housing
81-2.02 900.26 932.26 69-14.02 a 99-17.02 Fig. 72: Sensors, bearing housing a = alignment groove Table 59: List of components Description Part No. Description 69-14.02 Leakage sensor 900.26 Bolt/screw 81-2.02 Plug 932.26 Circlip 99-17.02 Desiccant 1581.86/03-EN-US Part No. 104 of 176 AmaCan D
-
9.2.9 Impeller fastening elements, tapered connection
930.10 914.10 Fig. 81: Impeller fastening elements, tapered connection Table 74: Key to the symbols Symbol L 243 Key Always secure screwed connections marked with this symbol with Loctite 243. Table 75: List of components Part No. Description Part No. 914.10 Hexagon socket head cap screw 930.10…
-
9.2.11 Grub screw in the impeller
904.59 Fig. 83: Grub screw 904.59 13) in the impeller Table 78: Key to the symbols Symbol L 243 Key Always secure screwed connections marked with this symbol with Loctite 243. Table 79: List of components Part No. Description Part No. Description 904.59 Grub screw - - 9.2.12 Mechanical seal with…
-
9.2.13 Float switch
81-45 411.26 Fig. 85: Float switch Table 82: Key to the symbols Symbol L 243 Key Always secure screwed connections marked with this symbol with Loctite 243. Table 83: List of components Part No. Description Part No. Description 411.26 Joint ring 81-45 Float switch 9.2.14 Lubricant inlet 903.04…
-
9.2.15 Lubricant drain / leakage chamber
903.06 411.06 903.02 411.02 903.03 Fig. 87: Lubricant drain / leakage chamber Table 86: Key to the symbols Symbol FD Key Always apply a liquid sealant (e.g. Hylomar SQ32M) to sealing surfaces marked with this symbol. Table 87: List of components Part No. Description Part No. Description 411.02/.06…
-
9.2.17 Model with adapter
L 243 80-1 914.06 412.06 82-5 914.02 L 243 112 Fig. 89: Model with adapter Table 89: Key to the symbols Symbol L 243 Key Always secure screwed connections marked with this symbol with Loctite 243. Table 90: List of components Description Part No. Description 112 Pump bowl 82-5 Adapter 412.06 O-ring…
-
9.3 Cable bundle
-
A-A
733.05 d 720 59-24 719.05 c Fig. 91: Section A - A, position of power cable, control cable and rope c Power cable d Control cable Table 92: List of components of the cable bundle Description Part number Description 59-7 Support 59-47 Lifting lug 59-8 Turnbuckle 719.05 Flexible tube 59-17.01/.02…
-
9.4 Wiring diagrams
9.4.1 Wiring diagram: power cable 1581.86/03-EN-US UG1417433 Fig. 92: Wiring diagram: power cable 1) Up to 3 parallel cable pairs possible * Shielded cable option AmaCan D 117 of 176
-
9.4.2 Wiring diagrams: sensors
9.4.2.1 Pump set with standard sensors Motor sizes: UG1415401 Fig. 93: Wiring diagram: pump set with standard sensors Shielded cable option Ⓐ Motor temperature (PTC) Ⓑ Mechanical seal leakage Ⓒ Bearing temperature (pump-end bearing) Ⓓ Bearing temperature (motor-end bearing) optional Ⓕ Leakage inside…
-
9.4.2.2 Pump set with sensor system
Motor sizes: UG2048584 Fig. 94: Wiring diagram: pump set with sensor system with one sensor unit Motor temperature (PTC) Ⓑ Mechanical seal leakage Ⓒ Bearing temperature, pump-end bearing (Pt100) Ⓓ Bearing temperature, motor-end bearing (Pt100) Ⓕ Leakage inside the motor Ⓗ Motor temperature (Pt100)…
-
Motor sizes
from 275 4 from 250 6 from 205 8 UG2048618 120 of 176 Ⓐ Motor temperature (PTC) Ⓑ Mechanical seal leakage Ⓒ Bearing temperature, pump-end bearing (Pt100) Ⓓ Bearing temperature, motor-end bearing (Pt100) Ⓕ Leakage inside the motor Ⓗ Motor temperature (Pt100) Ⓙ Activation of sensor unit 2 (PTC) AmaCan…
-
9.5 Flamepaths on explosion-proof motors
-
ков ©
-
9.6 Dimensions
-
Mo- Numtor ber
-
таблицы и схемы — в просмотре
-
Motor size Number
of poles d1 d2 d3 d4 d5 h1 h2 h3 h4 l1 l2 [kg]15) 600-390 2279 2239 517 1588 600-390 2479 2439 517 1788 722 80 1070 600-390 2479 2439 517 1788 722 80 1110 600-390 2479 2439 517 1788 722 80 1150 600-390 2279 2239 517 1588 600-390 2279 2239 517 1588 600-390 2279 2239 517 1588 600-390 2479 2439 517…
-
таблицы и схемы — в просмотре
-
9.7 General arrangement drawings
-
D
-
Illustration of the
overflow head hü Loss diagram Calculation formulas: H = Hgeo + ∆ Hv ∆ Hv ▪ Overflow head hü (see diagram) ▪ Loss in the riser (pipe friction) ▪ Outlet loss v2 / 2g (v refers to DA) Overflow head hü depends on Q and the discharge design ∅ DA. The characteristic curve values only apply to unimpeded…
-
9.7.1.2 Installation type BG
-
Table 98: Dimensions [inch]
Size ha h7 lmin. m p1 p2 s1 t322) t4 min.23) t9 600-390 3/8 27 5/9 31 1/2 21 1/4 2/7 11 98 3/7 14 3/4 600-420 4 18 8/9 49 1/5 27 5/9 31 1/2 21 1/4 2/7 10 5/8 96 1/2 18 1/2 700-390 3/8 31 1/2 35 3/7 25 1/5 1/3 11 110 1/4 14 3/4 700-420 4 18 8/9 49 1/5 31 1/2 35 3/7 25 1/5 1/3 10 5/8 110 1/4 18 1/2…
-
9.7.1.3 Installation types CU/CUS
-
DN2
-
Calculation formulas
H = Hgeo + ∆ Hv ∆ Hv ▪ Loss in the riser (pipe friction) ▪ Hv ges. (see diagram) Hv ges. comprises: ▪ Elbow ▪ Discharge pipe length = 5 x DN2 ▪ Swing check valve ▪ Outlet losses v2/2g Minimum water level diagrams t 1 [inches] 1&2 Q [1000*US.gpm] 1581.86/03-EN-US Fig. 103: Open intake chamber, design…
-
9.7.1.4 Installation type CG
-
Table 102: Dimensions [inch]
-
9.7.1.5 Installation types DU/DUS
-
DN2 min
-
Loss diagram
-
9.7.1.6 Installation type DG
-
Table 106: Dimensions [inch]
-
9.7.1.7 Dimensions of the flow-straightening vane
Design of the intake chamber wall surfaces (to prevent vortex formation) The flow-straightening vane is indispensable for the inlet conditions of the pump set. It prevents the development of a submerged vortex (floor vortex) which could cause a drop in performance, for example. In addition, the…
-
A
Bolted to the floor of the intake chamber B Flow-straightening vane centered beneath the discharge tube C Discharge tube D Intake chamber Installation types BU/BUS, CU/CUS, DU/DUS Table 107: Dimensions [inch] Size hR s1 s2 (e1) lR48) Suction umbrella Suction umbrella sR ✘ ✓ ✘ ✓ d8 d9 d8 d9 600-390 6…
-
9.7.2 General arrangement drawings [mm]
-
D
-
∆ Hv
▪ Overflow head hü (see diagram) ▪ Loss in the riser (pipe friction) ▪ Outlet loss v2 / 2 g (v refers to DA) Overflow head hü depends on Q and the discharge design ∅ DA. The characteristic curve values only apply to unimpeded outlet in all directions; otherwise they are approximate values only.…
-
9.7.2.2 Installation type BG
-
Table 112: Dimensions [mm]
-
9.7.2.3 Installation types CU/CUS
-
DN2
-
Calculation formulas
H = Hgeo + ∆ Hv ∆ Hv - Loss in the riser (pipe friction) - Hv ges. (see diagram) Hv ges. comprises: ▪ Elbow ▪ Discharge pipe length = 5 x DN2 ▪ Swing check valve ▪ Outlet losses v2/2g Minimum water level diagrams t1 [mm] 4000 3600 3200 1 2 2800 3 2400 4 2000 5 1600 1200 6 3 1000 1&2 0,1 0,2 0,3 0,4…
-
9.7.2.4 Installation type CG
-
Table 116: Dimensions [mm]
-
9.7.2.5 Installation types DU/DUS
-
DN2 min
-
Loss diagram
-
9.7.2.6 Installation type DG
-
Table 120: Dimensions [mm]
-
9.7.2.7 Dimensions of the flow-straightening vane
Design of the intake chamber wall surfaces (to prevent vortex formation) The flow-straightening vane is indispensable for the inlet conditions of the pump set. It prevents the development of a submerged vortex (floor vortex) which could cause a drop in performance, for example. In addition, the…
-
A
-
10 Certificate of Decontamination
10 Certificate of Decontamination Type: Order number/ Order item number82): Delivery date: Field of application: 82) Fluid handled : Please check where applicable82): ⃞ ⃞ ⃞ ⃞ ⃞ Corrosive Oxidizing Flammable Explosive Hazardous to health R ⃞ ⃞ ⃞ ⃞ ⃞ Seriously hazardous to health Toxic Radioactive…
-
Johann-Klein-Straße 9 • 67227 Frankenthal (Germany) Tel. +49 6233 86-0 www.ksb.com KSB SE & Co. KGaA Turmstraße 92 • 06110 Halle (Germany) Tel. +49 345 4826-0 www.ksb.com 1581.86/03-EN-US KSB SE & Co. KGaA