SPLIT TYPE ROOM AIR CONDITIONER
INSTALLATION MANUAL (PART NO. 9307518027-01) For authorized service personnel only. - WAR (1) For the room air conditioner to operate satisfactory, install it as outlined in this installation manual. (2) Connect the indoor unit and outdoor unit with the air conditioner piping and cords available…
-
-SELECTING THE MOUNTING——— r INSTALLATION DIAGRAM OF
POSITION INDOOR AND OUTDOOR UNITS Decide the mounting position with the customer as follows: Fig. 2 1. INDOOR UNIT [INDOOR UNIT] (1) Install the indoor unit level on a strong wail which is not subject to у Wail hook vibration. 5 ст or over bracket 6 ст or over (2) The inlet and outlet ports should…
-
INDOOR UNIT
CUTTING THE HOLE IN THE WALL (1} Cut a 65 mm diameter hole in the wall at the position shown in (Fig. 5). {2} When cutting the wall hole at the inside of the installation frame, cut the hole within the range of the left and right center marks 40 mm below the installation frame. When cutting the wail…
-
@ For left piping and left rear piping, align the marks on the wall hook Fig. 8 fal — шт
bracket and shape the connection pipe. ig. о Ue & э <> Ц @ Bend the connection piping at a bend radius of 70 mm ог more and = = install no more than 35 mm from the wall. Connection pipe {6.35 mm dia.) @ After passing the indoor piping and drain hose through the wall hole, hang the indoor unit on the…
-
[Cooling type]
(1) Remove the cord clamp. {2} Bend the end of the connection cord as shown in the figure. Fig. 11 Right bottom of indoor unit Earth screw Cord clamp (There is a terminal block inside.) ~ 13mm 12 тт / Connection cord (Equivalent to HO7RN-F) 3G x 1.5 mm? Under cover A М Pull Be sure that the cord is…
-
OUTDOOR UNIT
г OUTDOOR UNIT INSTALLATION @ ‘Set the unitona strong stand, such as one made of concrete blocks to minimize shock and vibration. @ Do not set the unit directly on the ground because it will cause trouble. Connector cover removal @ Remove the two mounting screws. @ = Put your hand on the back side (…
-
ADDITIONAL CHARGE
Refrigerant suitable for a piping length of 5 mis charged in the outdoor unit at the factory. For the additional amount, see the table below. р | | When the piping is longer than 5 m, additional charging is necessary. | | Table 3 | | ‘ 5m 7m 10m 7 Additional | “refrigerant: | None 32g 80g Between 5…
-
(1) Match the terminal block numbers and соппесtion cord colors with those of the indoor unit
Erroneous wiring may cause burning of the electric parts. Always fasten the outside covering of the connection cord with the cord clamp. (If the insulator is chafed, electric leakage may occur.) (2) Connect the connection cords firmly to the termi- nal block. Imperfect installation may cause a fire.…