Owner's Manual
-
To Users
Thank you for selecting Cooper&Hunter’s product. Please read this instruction manual carefully before installing and using the product, so as to master and correctly use the product. In order to guide you to correctly install and use our product and achieve expected operating effect, we hereby…
-
necessary revision to the product from time to time due to the reason of
sales or production, and reserve the right to revise the contents without further notice. (7) Indoor unit must not be installed in a laundry. (8) If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. (9)…
-
1 Safety Notices (Please be sure to abide)
SPECIAL WARNING: (1) Do not pierce or burn. (2) Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. (3) Be aware that refrigerants may not contain an odor. PROHIBITED: This sign indicates that the operation must be prohibited. Improper…
-
PROHIBITED
(1) The air conditioner should be grounded to avoid electric shock. Do not connect the ground wire to gas pipe, water pipe, lightning arrester or telephone wire. (2) The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.…
-
Please install the air conditioner in a secure place that can withstand the weight of air conditioner. Insecure installation may cause the air conditioner falling down and lead to injury. (10) Be sure to adopt independent power circuit. If the power cord is damaged, it must be repaired by the…
-
(24) Do not make the air conditioner wet or electric shock may be lead; Ensure that
the air conditioner will not be cleaned by water rinsing under any circumstance. NOTICE (1) Do not put a finger or other objects into the air inlet or air return grill. (2) Please adopt safety protection measures before touching the refrigerant pipe; otherwise your hands may be hurt. (3) Please…
-
OBSERVED
(1) If wired control is to be used, it should be connected first before powering up the unit, otherwise the wired control may not be able to use. (2) When installing the indoor unit, keep it away from television, wireless waves, and fluorescent. (3) Only use soft dry cloth or slightly wet cloth with…
-
2 Product Introduction
2.1 Overall Layout NOTICE: The connection pipe, drain pipe, power cord, for this unit should be prepared by the user. 6
-
2.2 Product Operating Range
Cooling Heating Outdoor temperature DB(°C) -15~48 -20~24 Indoor temperature DB/WB(°C) (Maximum) 32/23 27/- 2.3 Standard Accessories Indoor Unit Accessories No. Name 1 Drain Hose 1 2 Bolt with Washer 4 3 Washer Appearance Installation Paperboard Gasket Mounting Board Q'ty Usage To connect with the…
-
Indoor Unit Accessories
No. Name Appearance Q'ty 16 Flannelette 1 17 Bolt Assembly 4 Usage To prevent the communication wire from reaching out the electric raceway(only 35/50) Connect the panel and body(only 35/50) Outdoor Unit Accessories No Name 1 Drain Plug 2 Drainage Connector Appearance Q'ty Usage 1or3 To plug the…
-
Selection of Installation Location for Indoor Unit (Select a location
pursuant to the following condition). (1) Air inlet and outlet of the indoor unit should be away from obstacles to make sure the unit’s air flow can reach the entire room. Do not install the unit in a kitchen or a laundry. (2) Select a location that can withstand 4 times the unit weight without…
-
fan and lead to insufficient air flow volume and thus affecting the unit’s
performance. (7) Install the outdoor unit at a place that is convenient for it to be connected to the indoor unit. (8) Away from any object that may get the air conditioner generating noise. (9) Install the outdoor unit at a place where condensate can be easily drained. 3.1.2 Unit Dimension WARNING…
-
NOTICE
-
3.1.3 Diagram of Unit Installation Space and Location
-
2) When two or more outdoor units are to be installed side by side
-
3) When outdoor units are installed in rows
-
4) When outdoor units are installed one above another
Unit: mm 400 500 2000 (2) Diagram of installation location and space for indoor unit (Notice: for the best performance of indoor unit, make sure its installation space conforms to the following installation dimensions). H 20mm or above Wall 1500mm or above 2500mm or above Wall 1500mm or above Wall…
-
Model
CH-IC035NK CH-IC050NK CH-IC071NK CH-IC100NK CH-IC125NK CH-IC140NK CH-IC160NK H(mm) 3.2 Unit Installation 3.2.1 Indoor Unit Installation In order to make the front panel cover 20mm of the ceiling, the distance between the ceiling and the unit should be 35mm or less. If the distance between the…
-
(2) Installing the Main Body Unit
1) Install the hoisting stand on the hoisting screw by using nuts and gaskets at both the upper and lower sides of the hoisting stand. To prevent the gasket from breaking off, a gasket anchor board can be helpful. 2) Install the paper template on the unit, and fix the drain pipe at the outlet vent.…
-
3.2.1.2 Leveling
The water level test must be done after installing the indoor unit to make the unit is horizontal, as shown below. Horizontal tester 3.2.2 Outdoor Unit Installation (1) If the outdoor unit is installed on a solid ground such as concrete, use M10 screw bolts and nuts to secure the unit and make sure…
-
3.2.3 Connection Pipe Requirement
3.2.3.1 Installation Notice and Requirement on Connection Pipe Installation method: Connect the connection pipes first to the indoor unit and then to the outdoor unit. When bending a connection pipe, be careful not to damage the pipe. Do not over-tighten the screw nut, otherwise leakage will occur.…
-
The requirement on the adding of oil return bend is as below
(1) Outdoor unit is beneath the indoor unit. There’s no need to add non-return bend at the lowest or highest position of the vertical pipe, as shown below: Indoor unit System gas pipe Oil return bend Install an oil return bend every 6m Outdoor unit (2) Outdoor unit is above the indoor unit. It’s…
-
Dimensions for the making of oil return bend are as follows
B C A A B(mm) C(mm) 3/8 ≥20 ≤150 Ф12 1/2 ≥26 ≤150 Ф16 5/8 ≥33 ≤150 mm in. Ф9 3.2.3.2 Pipe Flaring (1) Cut the connection pipe with a pipe cutter. (2) The mouth of connection pipe should face downward. Remove burrs with the cut surface so that the chips do not enter the pipe. (3) Take out the flare…
-
(2) Do not bend the pipes in an angle more than 90°
(3) If the pipe is repeatedly bent or extended, it will become hard and difficult to be bent or extended. So do not bend or extend the pipe for more than 3 times. (4) When bending the pipe, do not bend it excessively, otherwise it will get broken. As shown beside, use a sharp cutter to cut the Pipe…
-
Pipe Diameter(In)
Tightening Torque(N·m) 1/4" 15-30 3/8" 35-40 1/2" 45-50 5/8" 60-65 3/4" 70-75 7/8" 80-85 Screw on the flare nut of the flaring connecting pipe on the outdoor unit valve. The method of screwing the flare nut is the same with that for indoor unit. Gas pipe Liquid pipe Pipe coupling or or 3-way valve…
-
3.2.4 Connection Pipe Vacuum Pumping
NOTICE Make sure the outlet of vacuum pump is away from fire source and is wellventilated. (1) Remove the caps of the liquid valve, gas valve and also the service port. (2) Connect the hose at the low pressure side of the manifold valve assembly to the service port of the unit’s gas valve, and…
-
gauge manifold
Pressure gauge (Low-pressure) Pressure gauge (Hi-pressure) Switch (Low-pressure) Switch (Hi-pressure) Connection pipe Connection pipe (to indoor unit) Cap Liquid valve Service pipe Gas valve Cap Hose Service port Hose with the valve pin Cap Vacuum pump NOTICE: For large-size units, there are…
-
(2) It is not allowed to connect the condensate drain pipe into rain pipe to
prevent rain water from pouring in and cause property loss or personal injury. (3) Condensate drain pipe should be connected into special drain system for air conditioner. 3.2.6.1 Indoor Side Drainage Pipe (1) Keep pipe size equal to or greater than that of the connecting pipe. (2) Install the drain…
-
A 3 During the installation, distance from soft drain pipe to the gasket is A mm when the bolt is tightened. It is not allowed to apply PVC or other related glue in the joints of two ends of drain pipe. ① Metal clamp (accessory) ② Insulation sponge (accessory) Insulate the pipe clamp and the drain…
-
(2) If the outdoor unit is above the indoor unit, arrange the pipeline according
to the following diagram. 1) Wind the insulating tape from bottom to top. 2) The whole pipeline should be wound together to avoid water returning to the room. 3) Use saddles to fix the whole pipeline onto the wall. 29
-
3.2.6.3 Notice on Drain Lift Pipe
(1) The drain lift pipe should be 1000mm or less away from ground, as shown below. (2) If multiple drain pipes are to be converged, please install according to the following process. Make sure the main drain pipe is laid downward at a certain angle. 100mm T-joint converging drain pipes 0~1000mm…
-
3) Install horizontal pipe as shown in the right figure
3-way connection of Drainage pipe joint Connection of drain elbow Connection of horizontal pipe 3.2.6.4 Check Drainage After the pipeline work is finished, check whether the drainage can go smoothly. (1) Add slowly about 1L of water into the water tray. After the electric circuit is completed, check…
-
3.2.7 Installing the Front Panel
As shown below, take off the 4 corner covers from the front panel and loose the hexagon screw bolts on the 4 fasteners to the maximum. The position marked with “PIPING SIDE” on the front panel will direct right at the pipe mouth of the indoor unit. (1) Temporarily hang the 4 fasteners on the…
-
Notice
(1) Improper screw looseness will lead to the following problem. Gas leakage Gas leakage of ceiling Condensate Water drops (2) After the screws are tightened, if there is still a gap between the ceiling and the decorative front panel, adjust the height of the unit again (as shown below). If the…
-
Match the corresponding slots
WARNING After installing the panel, the insulated protective cover with the thickness of 1mm shall be used to wrap the wiring terminal, Tighten the insulated glue cover on both sides with bonding tie to fix it. (5) After connecting the communication wire, attach the flannelette on the foam to…
-
3.3 Electrical Installation
3.3.1 Requirement and Notice on Electrical Installation WARNING: The electrical installation for the air conditioner should observe the following requirements: ① The electrical installation must be conducted by professionals in compliance with local laws and regulations and the instructions in this…
-
cables, please contact Cooper&Hunter’s local service center
⑩ Wiring terminals should be connected firmly to the terminal board. Loose connection is forbidden. ⑪ After the electrical installation is finished, please use wire clamps to secure the power cord, connection wire of indoor and outdoor units and the communication cords. Make sure the wires are not…
-
plugged or unplugged
③ Circuit breaker and power cord specifications listed in the above table are determined based on the maximum power input of the units. ④ Supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible cord (code designation 60245 IEC 57). ⑤…
-
10mm of the insulation layer
2) Use a screwdriver to unscrew the terminal screw on the terminal board. 3) Use a round terminal fastener or clamp to fix the round terminal firmly on the peeled wire end. 4) Locate the round terminal conduit. Use a screwdriver to replace it and tighten up the terminal screw (as shown below). A…
-
(1) Before working, please check whether the indoor and outdoor units are powered
on. (2) Match the terminal numbers and wire colors with the colors indicated in the indoor unit. (3) Wrong wire connection may burn the electrical components. (4) Connect the wires firmly to the wiring box. Incomplete installation may lead to fire hazard. (5) Please use wire clamps to secure the…
-
CH-IC140NK+CH-IU140NM CH-IC160NK+CH-IU160NM ① Power cord 5×1.5mm2 ② Power cord 3×1.0mm2 ③ Communication Cords 2×0.75mm2 ④ Communication Cords 2×0.75mm2 (5) Electrical wiring of indoor unit. WARNING (1) High and low voltage wires should be led through different rubber rings of the electric box cover.…
-
1) Indoor side
Take off the electric box cover from the sub-assembly of electric box. Then connect the wires. Connect the connection wires of indoor unit according to the corresponding marks. 2) Outdoor side Remove the big handle/front panel of the outdoor unit and insert one end of the communication cord and the…
-
b) Wire routing of unified power supply
-
b) Wire routing of unified power supply for single phase
-
b) Wire routing of unified power supply for three-phase
Power cord should be secured along with the right side plate and fixed to the hook with a wire clamp so as to avoid contacting the pipeline. The communication line between indoor and outdoor units should also be laid along with the right side plate but away from the power cord. 3.4 Check after…
-
3.5 Test Running
Preparation before connecting the power (1) Power must not be connected if the installation work is not completed. (2) Control circuit is correct and all the wires are firmly connected. (3) Cut-off valves of the gas pipe and liquid pipe are open. (4) The inside of the unit should be clean. Take…
-
5 Maintenance
5.1 Failures Not Caused by Faults of the AC (1) If your air conditioner fails to function normally, please first check the following items before maintenance: Problem The air conditioner can't run. Cause Corrective measure If you turn off the unit and then immediately turn it on, in order to protect…
-
(2) The following situations are not operation failures
Problem Mist comes from the air conditioner. Mist comes from the air conditioner. Time of occurrence During operation. System switches to heating mode after defrosting. The air conditioner is buzzing at the beginning of operation. When the unit is turned on, it purrs. Dust comes from the air…
-
NOTICE: Check the above items and adopt the corresponding corrective
measures. If the air conditioner continues to function poorly, please stop the air conditioner immediately and contact Cooper&Hunter’s authorized local service center. Ask our professional service staff to check and repair the unit. 5.2 Error Code WARNING (1) If abnormal things (for example, awful…
-
Number
Error code Error 16 PF Electric box sensor error 17 H3 Compressor overload protection 18 H4 Overload 19 H5 IPM protection 20 H6 DC fan error 21 H7 Driver out-of-step protection 22 HC Pfc protection 23 Lc Startup failure 24 Ld Compressor phase-sequence protection 25 LF Power protection 26 Lp IDU and…
-
NOTICE: When the unit is connected with the wired controller, the error code
will be simultaneously shown on it. Instructions to the Error Indicating Lamps on the Panel of the Cassette Type Unit. Power and ON/OFF Indicating Lamp: It goes red when the unit is powered on while it goes white when the unit is started. Timer Indicating Lamp: It goes on when the timer is set and…
-
(5) If you need to replace a component, please ask a professional to repair with a
component supplied by the original manufacturer so as to ensure the unit’s quality. (6) Improper operation may get the unit broken, hit by electric shock or cause fire. (7) Do not make the air conditioner wet or electric shock may be lead; ensure that the air conditioner will not be cleaned by water…
-
How to clean the air filter
(4) Fix the 3 cleaners on the filter and then re-install the filter by fitting it into the protruding parts on top of the air intake grill. Pull the handle at the back of the air intake grill to secure the filter. - (5) Close the air intake grill. Push the clasps outward and then match the air…
-
(3) Check if the exhausted batteries of the wireless controller have been
replaced. (4) Check if the air filter had been installed well by professional. Keep the power switch “On” 8 hours before the startup of the unit which has not been used for a long period. 5.3.5 Maintenance at the End of the Using Season (1) Cut off the main power of air conditioner. (2) Clean the…