Rooftop - Cooling Only or Heat Pump
-
Technical Features
General The RT4D is a pre-assembled weatherproof single package, designed to save energy with long life durability. The RT4D is an air to air double flow heat-pump combined with 2 blowers and 4 dampers. The quantities of return-, exhaust- and outdoor air are managed by the 4 dampers to provide…
-
The outdoor coil (BCO) is divided in two vertical coils, V-formed,
when the RT4Ds has two circuits. This unique feature eases the defrost of one circuit without disturbing the heating of the other circuit. There is one drain pan under both outdoor coils. The drain pan is equipped with an electric heater (RE) to melt the ice during the defrost cycle in winter. …
-
Speed Defrost
In heating mode, particular attention has been given to shorten the time of defrost and reduce the un-comfort in the building and improve the overall efficiency. With two circuits, the RT4D allows one circuit at a time to defrost. The unique design of the outdoor coil split in two vertical coils…
-
ROOM
Legend : Return air D1 Exhaust air damper (air leaving the building) D2 Return air damper (air recirculated to the building) Bag filter Indoor coil IC Return air damper Exhaust air damper D2 OC Outdoor coils D1 EF Supply fan centrifugal Outdoor air damper (fresh air for ventilation of occupants and…
-
Optional Features
Hot Water Heat Hot water heat is an option, factory mounted down-stream of the indoor coil. The coil covers the entire surface of the indoor coil with low air velocity to reduce the blower energy consumption and the noise level. The coil is protected by a freeze stat. A factory fitted 3-way…
-
Automation and Controls
The RT4D is assembled and wired at the factory with all the necessary automation and control devices. It is fully tested at the factory and shipped READY-TO-START to ease the start-up and commissioning on site. The electrical and control board is mounted in weatherproof cabinet with hinged door…
-
Physical Data
RT4D SIZE Cooling capacity (1) kW Sensible heat factor 16.2 29.2 33.4 50.4 58.4 83.9 103.9 150.7 167.5 207.8 0.65 0.6 0.61 0.61 0.63 0.64 0.64 0.64 0.64 0.64 12.2 17.5 20.9 30.6 37 57.6 61.2 80.8 Total power input kW 5.3 9.81 Compressor power input kW 3.85 6.91 7.8 11.6 14 19.7 24.1 35.8 39.4 49…
-
Electrical Data
Unit without electric heater RT4D models Supply voltage Total running current Maximum starting current A A 14.5 45.7 30.2 84 48.0 151 65.4 170 82.4 10.5 10.5 V / 3 Ph / 50 Hz 56.2 81.1 152.2 285 162.2 298 205.2 V / 3 Ph / 50 Hz 98.1 130.0 157.9 215.1 348 235.6 371 289.0 Unit with electric heater…
-
Units Performance Data - RT4D 20
Summer performances Size : RT4D 20 Outdoor air percentage = 0% Indoor conditions (Dry bulb °C / Wet bulb °C) 14.7 14.3 14.1 13.7 13.4 13.1 Compressors power input (kW) 3.3 3.7 3.8 4.1 4.3 4.5 Cooling capacity (kW) 15.5 15 14.8 14.4 14 13.7 Cooling capacity (kW) 24 °C / 18 °C 26 °C / 19.5 °C 29 °C /…
-
Units Performance Data - RT4D 20 (continued)
Summer performances Size : RT4D 20 Outdoor air percentage = 40% Indoor conditions (Dry bulb °C / Wet bulb °C) 24 °C / 18 °C 26 °C / 19.5 °C 29 °C / 22 °C 31 °C / 24 °C Outdoor temperature (dry bulb °C) Cooling capacity (kW) 16.5 16.1 15.9 15.4 15.1 14.7 Compressors power input (kW) 3.10 3.47 3.57…
-
Units Performance Data - RT4D 40
Summer performances Size : RT4D 40 Outdoor air percentage = 0% Indoor conditions (Dry bulb °C / Wet bulb °C) Cooling capacity (kW) 24 °C / 18 °C 26 °C / 19.5 °C 29 °C / 22 °C 31 °C / 24 °C Outdoor temperature (dry bulb °C) 26.2 25.4 25.1 24.5 24 23.6 Compressors power input (kW) 5.4 6.1 6.4 7.2 7.4…
-
Units Performance Data - RT4D 40 (continued)
Summer performances Size : RT4D 40 Outdoor air percentage = 40% Indoor conditions (Dry bulb °C / Wet bulb °C) 24 °C / 18 °C 26 °C / 19.5 °C 29 °C / 22 °C 31 °C / 24 °C Outdoor temperature (dry bulb °C) Cooling capacity (kW) 29.5 28.6 28.3 27.6 27.0 26.6 Compressors power input (kW) 5.25 5.93 6.23…
-
Units Performance Data - RT4D 60
Summer performances Size : RT4D 60 Outdoor air percentage = 0% Indoor conditions (Dry bulb °C / Wet bulb °C) 30.4 29.4 29 28.4 27.7 27.3 Compressors power input (kW) 6.1 6.9 7.2 7.7 8.3 8.7 Cooling capacity (kW) 32.1 31 30.6 29.9 29.2 28.8 Cooling capacity (kW) 24 °C / 18 °C 26 °C / 19.5 °C 29 °C /…
-
Units Performance Data - RT4D 60 (continued)
Summer performances Size : RT4D 60 Outdoor air percentage = 40% Indoor conditions (Dry bulb °C / Wet bulb °C) 24 °C / 18 °C 26 °C / 19.5 °C 29 °C / 22 °C 31 °C / 24 °C Outdoor temperature (dry bulb °C) Cooling capacity (kW) 34.0 32.8 32.4 31.7 30.9 30.5 Compressors power input (kW) 5.99 6.77 7.07…
-
Units Performance Data - RT4D 80
Summer performances Size : RT4D 80 Outdoor air percentage = 0% Indoor conditions (Dry bulb °C / Wet bulb °C) 24 °C / 18 °C 26 °C / 19.5 °C 29 °C / 22 °C 31 °C / 24 °C Outdoor temperature (dry bulb °C) Cooling capacity (kW) 45.4 44.1 43.6 42.7 41.8 41.2 Compressors power input (kW) 10.1 11.3 11.7…
-
Units Performance Data - RT4D 80 (continued)
Summer performances Size : RT4D 80 Outdoor air percentage = 40% Indoor conditions (Dry bulb °C / Wet bulb °C) 24 °C / 18 °C 26 °C / 19.5 °C 29 °C / 22 °C 31 °C / 24 °C Outdoor temperature (dry bulb °C) Cooling capacity (kW) 50.7 49.3 48.7 47.7 46.7 46.0 Compressors power input (kW) 9.23 10.32 10.69…
-
Units Performance Data - RT4D 100
Summer performances Size : RT4D 100 Outdoor air percentage = 0% Indoor conditions (Dry bulb °C / Wet bulb °C) 24 °C / 18 °C 26 °C / 19.5 °C 29 °C / 22 °C 31 °C / 24 °C Outdoor temperature (dry bulb °C) Cooling capacity (kW) 52.8 51 50.3 49.1 47.9 47 Compressors power input (kW) 11.37 12.83 13.45…
-
Units Performance Data - RT4D 100 (continued)
Summer performances Size : RT4D 100 Outdoor air percentage = 40% Indoor conditions (Dry bulb °C / Wet bulb °C) 24 °C / 18 °C 26 °C / 19.5 °C 29 °C / 22 °C 31 °C / 24 °C Outdoor temperature (dry bulb °C) Cooling capacity (kW) 59.9 57.8 57.0 55.7 54.3 53.3 Compressors power input (kW) 10.99 12.40…
-
Units Performance Data - RT4D 140
Summer performances Size : RT4D 140 Outdoor air percentage = 0% Indoor conditions (Dry bulb °C / Wet bulb °C) 24 °C / 18 °C 26 °C / 19.5 °C 29 °C / 22 °C 31 °C / 24 °C Outdoor temperature (dry bulb °C) Cooling capacity (kW) 75.1 72.7 71.7 70.2 68.4 67.1 Compressors power input (kW) 16.3 18.3 19.2…
-
Units Performance Data - RT4D 140 (continued)
Summer performances Size : RT4D 140 Outdoor air percentage = 40% Indoor conditions (Dry bulb °C / Wet bulb °C) 24 °C / 18 °C 26 °C / 19.5 °C 29 °C / 22 °C 31 °C / 24 °C Outdoor temperature (dry bulb °C) Cooling capacity (kW) 85.5 82.7 81.6 79.9 77.8 76.4 Compressors power input (kW) 15.44 17.33…
-
Units Performance Data - RT4D 180
Summer performances Size : RT4D 180 Outdoor air percentage = 0% Indoor conditions (Dry bulb °C / Wet bulb °C) 24 °C / 18 °C 26 °C / 19.5 °C 29 °C / 22 °C 31 °C / 24 °C Outdoor temperature (dry bulb °C) Cooling capacity (kW) 92.8 90 88.7 86.7 84.7 83.4 Compressors power input (kW) 21.2 23.5 24.5 26.2…
-
Units Performance Data - RT4D 180 (continued)
Summer performances Size : RT4D 180 Outdoor air percentage = 40% Indoor conditions (Dry bulb °C / Wet bulb °C) 24 °C / 18 °C 26 °C / 19.5 °C 29 °C / 22 °C 31 °C / 24 °C Outdoor temperature (dry bulb °C) Cooling capacity (kW) 105.6 102.4 100.9 98.7 96.4 94.9 Compressors power input (kW) 19.29 21.38…
-
Units Performance Data - RT4D 240
Summer performances Size : RT4D 240 Outdoor air percentage = 0% Indoor conditions (Dry bulb °C / Wet bulb °C) 24 °C / 18 °C 26 °C / 19.5 °C 29 °C / 22 °C 31 °C / 24 °C Outdoor temperature (dry bulb °C) Cooling capacity (kW) 135.80 131.4 129.5 126.3 122.9 120.9 Compressors power input (kW) 29.2 32.8…
-
Units Performance Data - RT4D 240 (continued)
Summer performances Size : RT4D 240 Outdoor air percentage = 40% Indoor conditions (Dry bulb °C / Wet bulb °C) 24 °C / 18 °C 26 °C / 19.5 °C 29 °C / 22 °C 31 °C / 24 °C Outdoor temperature (dry bulb °C) Cooling capacity (kW) 153.9 148.9 146.7 143.1 139.2 137.0 Compressors power input (kW) 28.24…
-
Units Performance Data - RT4D 280
Summer performances Size : RT4D 280 Outdoor air percentage = 0% Indoor conditions (Dry bulb °C / Wet bulb °C) Cooling capacity (kW) 24 °C / 18 °C 26 °C / 19.5 °C 29 °C / 22 °C 31 °C / 24 °C Outdoor temperature (dry bulb °C) 148.60 143.9 142 138.9 135.7 133.5 Compressors power input (kW) 31.3 35.2…
-
Units Performance Data - RT4D 280 (continued)
Summer performances Size : RT4D 280 Outdoor air percentage = 40% Indoor conditions (Dry bulb °C / Wet bulb °C) 24 °C / 18 °C 26 °C / 19.5 °C 29 °C / 22 °C 31 °C / 24 °C Outdoor temperature (dry bulb °C) Cooling capacity (kW) 170.3 164.9 162.7 159.2 155.5 153.0 Compressors power input (kW) 30.84…
-
Units Performance Data - RT4D 380
Summer performances Size : RT4D 380 Outdoor air percentage = 0% Indoor conditions (Dry bulb °C / Wet bulb °C) Cooling capacity (kW) 24 °C / 18 °C 26 °C / 19.5 °C 29 °C / 22 °C 31 °C / 24 °C Outdoor temperature (dry bulb °C) 182.70 177.8 175.7 172.4 168.9 166.5 Compressors power input (kW) 40 44.5…
-
Units Performance Data - RT4D 380 (continued)
Summer performances Size : RT4D 380 Outdoor air percentage = 40% Indoor conditions (Dry bulb °C / Wet bulb °C) 24 °C / 18 °C 26 °C / 19.5 °C 29 °C / 22 °C 31 °C / 24 °C Outdoor temperature (dry bulb °C) Cooling capacity (kW) 208.8 203.2 200.8 197.1 193.1 190.3 Compressors power input (kW) 39.22…
-
Hot Water Coils Performance Data (Option)
Number of rows : 2 RT4D 20 Nominal air flow = 2 000 m3/h Water temperature in-out = 70 °C - 60 °C Outdoor Outdoor air Supply temp. °C % volume temp. °C 7 3 -3 -7 40% 43.3 41.1 37.8 35.4 Heating capacity kW 17.7 19.2 21.5 23 RT4D 80 Nominal air flow = 8 000 m3/h Water temperature in-out = 70 °C - 60…
-
Number of rows : 2
RT4D 180 Nominal air flow = 18 000 m3/h Water temperature in-out = 70 °C - 60 °C Outdoor Outdoor air Supply temp. °C % volume temp. °C 7 3 -3 -7 40% 37.6 35 31.1 28.4 Heating capacity kW RT4D 280 Nominal air flow = 28 000 m3/h Water temperature in-out = 70 °C - 60 °C Water flow Water rate pressure…
-
Number of rows : 3
RT4D 20 Nominal air flow = 2 000 m3/h Water temperature in-out = 70 °C - 60 °C Outdoor Outdoor air Supply temp. °C % volume temp. °C 7 3 -3 -7 40% 51.1 49.4 46.8 44.9 Heating capacity kW 22.9 24.9 27.8 29.8 RT4D 80 Nominal air flow = 8 000 m3/h Water temperature in-out = 70 °C - 60 °C Water flow…
-
Number of rows : 3
RT4D 180 Nominal air flow = 18 000 m3/h Water temperature in-out = 70 °C - 60 °C Outdoor Outdoor air Supply temp. °C % volume temp. °C 7 3 -3 -7 40% 44.2 42 38.7 36.4 Heating capacity kW RT4D 280 Nominal air flow = 28 000 m3/h Water temperature in-out = 70 °C - 60 °C Water flow Water rate pressure…
-
Supply Fan Curves
-
RT4D 60
RT4D 80 Page 35
-
RT4D 100
RT4D 140 Page 36
-
RT4D 180
RT4D 240 Page 37
-
Outdoor Fan Curves
-
Outdoor Fan Curves (continued)
-
таблицы и схемы — в просмотре
-
Component Air Pressure Drops
-
Component Air Pressure Drops (continued)
-
таблицы и схемы — в просмотре
-
Dimensions - RT4D 60 & 80
-
Dimensions - RT4D 100 & 140
-
Dimensions - RT4D 180 & 240
-
Dimensions - RT4D 280 & 380
-
GENERAL SCOPE REFRIGERATION SECTION The ROOFTOP shall be RT4D type, factory assembled with weatherproof construction. It will be a single package unit including wired electrical Automation and Controls, with charged refrigerant system, air handling and heating section tested on the factory. The…
-
BLOWER AND DRIVE SECTION
THE SUPPLY BLOWER SECTION The blower(s) shall be belt driven, (direct driven) centrifugal with two inlets, vibration isolated, mounted in a reinforced frame and attached to the cabinet with a flexible connection. The blower shall have backward curved blades. The motor shall be mounted on an…
-
The ignition and the control of the flame shall be automatic
The wiring shall comply with CE standards and EN 60204-1. The burner shall be for two stages heat. All cables and wires shall be individually identified. The burner shall be modulating. The unit shall be equipped with one single power inlet connection, sized to the total current draw of…
-
Technical Data
Nominal cooling capacity kW Hot water Summer outdoor temperature °C Entering water temperature Summer indoor temperature dry bulb °C Summer indoor temperature wet bulb Leaving water temperature °C S/T ratio m /h Water pressure drop bar 3 Electric heat kW Number of stages Heat-pump winter outdoor °C…
-
As part of our ongoing product improvement programme, our products are subject to change without prior notice. Non contractual photos. ACE Industrie - Route de Verneuil - 27570 Tillières-sur-Avre - France - : +33 (0)2 - : +33 (0)2