PORTABLE AIR CONDITIONER ELECTRONIC / REMOTE CONTROL ELECTRO MECHANICAL CONTROL INSTALLATION AND OPERATING INSTRUCTIONS
-
9 INTRODUCTION
This portable air conditioner is designed for versatile applications: . Cooling . Dehumidification . Heating (for electronic models only) . Ventilation . Air filtration ELECTRONIC MODELS ONLY This air conditioner is equipped with an electronic microprocessor control system, giving the user the…
-
О DESCRIPTION
be a / Electronic model Electro-Mechanical model Figure 1: Units components (front) . Control buttons (for electromechanical model) . Indicators (leds) . Adjusting air supply grille . Carrying handle . Water tank door Castors . Air filter . Air filter handle 9. Electric Power cord 10. Drain tube…
-
OINSTALLATION
INSTALLATION FOR COOLING FIXED INSTALLATION OPTION (See fig. 4 and fig. 5) For fixed installation, a sleeve (see 1, fig.4) should be installed through the wall, partition or window (see fig.5). Prepare a 110 mm diameter outlet hole. Apply a waterproof sealant to the sleeve flange and install it in…
-
PROVISIONAL INSTALLATION (See figure 6)
This method of installation does not require a permanent opening in the room. The exhaust hose is inserted through an opening in a doorway or a slightly opened window. This allows the unit to be easily moved from room to room and re-installed within minutes. Fit the window nozzle (4, fig. 3) to the…
-
INSTALLATION FOR HEATING -— For Electronic Models Only (see figures 3, 7)
The exhaust hose is not required for heating operations. Remove the hose and store it. Use the Sleeve Cover (2,Fig. 3) to close the wall opening. Close also the air exhaust opening with the Air Exhaust Cover. (See fig. 7). INSTALLATION FOR «DRY» OPERATION - For Electronic Models Only In DRY…
-
О OPERATION - (With remote control)
In order to obtain maximum comfort and economical operation, please make sure: . To follow the instructions for Installation For Cooling on page 4. . That the air outlet and inlet openings on the unit are unobstructed. ° To shade the room from direct sunrays and avoid excessive sources of heat in…
-
VERTICAL AIR SWING (OPTIONAL)
Automatic swing of air supply in a vertical direction. The flaps automatically move in upward and downward directions to disperse the conditioned air evenly throughout the room. FILTER AND WATER OVERFLOW INDICATION (see indicator C on figure 10) Filter indicator on the indoor unit display is turned…
-
USE OF WIRELESS REMOTE CONTROL
PRIOR TO OPERATION Prior to operating your air conditioner, make sure that: e The unit is properly connected to the power supply. . The red tab protecting the remote control battery has been removed. . For clock settings, see page 15. REMOTE CONTROL BATTERY CHANGE ® Remove the batteries from the…
-
ON-UNIT INDICATORS AND CONTROLS (see Figure 10)
A. TIMER INDICATOR и (Е) Lights up during TIMER and SLEEP operation. и Na B. OPERATION INDICATOR Lights up during operation. Blinks to confirm that the remote control infrared signal has been received and stored. C. FILTER AND WATER OVERFLOW INDICATOR Lights up when air filter requires cleaning.…
-
REMOTE CONTROL (see Figure 11)
Figure 11 English 11 @9eo po GBGoododooddeods START/STOP button Operation MODE selection button FAN SPEED and AUTO FAN button Temperature set UP button (+) Temperature set DOWN button (-) SLEEP button Automatic vertical air swing TIMER select button TIMER set up button (+) TIMER set down button (-)…
-
OPERATION PROCEDURE (see Figs. 10 & 11)
TURNING ON THE AIR CONDITIONER Press START/STOP button (1) to turn on the air conditioner. Operation Indicator (B) on the air conditioner will light up, indicating that the unit is in operation. Note that the LCD operation display (11) will always show the last mode of operation and the previous…
-
AUTOMATIC VERTICAL AIR SWING
Press button (7) to activate the auto air swing. Press the button again to deactivate this function. HEATING OPERATION * Select the HEATING mode by pressing MODE button (2). Switch to the desired Fan Speed or to AUTO FAN by pressing the Fan button (3). Select the suitable temperature setting. (see…
-
DRY OPERATION
Select DRY mode by pressing MODE button (2). Select the suitable temperature setting. While in DRY mode, the air conditioner will operate at low fan speed, regardless of the fan setting on the LCD operation display. The fan might stop operating from time to time to prevent over-cooling. NOTE: In…
-
CURRENT CLOCK TIME SET
Clock setting is performed when batteries are inserted. The remote control displays the setting, and the clock display will blink " 00:00" or" 12:00" until a new time is set. For clock settings, use buttons (9) (10) in order to set the hours and minutes, respectively, and then press timer SET button…
-
TIMER OPERATING MODES
1. TIMER ON This mode enables you to set a time for starting its operation. Press the TIMER button (8) until the ON sign blinks. Starting time can be adjusted using the up and down buttons (9) and (10), respectively. Press SET button (13) to activate the timer. Example: Operation is restored at…
-
О OPERATION - (Electro - Mechanical Model)
The air conditioner has the following features: e On-unit operation control . Indicator control leds . Warning light ° Thermostat ON UNIT CONTROL AND DISPLAY PANEL (see figure 13) In order to obtain maximum comfort and economical operation, please make sure: ° To follow the instructions for…
-
OPERATING PROCEDURE
Plug the unit into a power supply, and the operation indicator (C2) lights up. This indicates that the unit is ready for operation. @ a TURNING ON THE AIR CONDITIONER Turn the selector switch knob (A) from OFF to any desired position. FAN OPERATION (VENTILATING) Turn the selector switch knob (A) to…
-
О CARE AND MAINTENANCE
Figure 15 Figure 17 Figure 16 Figure 18 WARNING Before performing any maintenance procedure, make sure to disconnect the air conditioner from the power supply. One of the functions of the air conditioner is to filter the supplied air by collecting dust and dirt particles from the air. Your air…
-
AT THE BEGINNING OF THE SEASON
° Make sure there are no obstacles blocking the flow of inlet or outlet air. . Make sure the power supply is_ properly connected. WATER TANK REMOVAL AND DRAINING NOTE: To avoid water leakage on to the floor of the room, wait for at least 5 minutes after the unit has stopped cooling before removing…
-
IMPORTANT NOTICES
This air conditioner has been manufactured for domestic environments and should not be used for any other purpose. Do not obstruct the air conditioner’s air discharge and inlet. If repair is needed, contact only the nearest authorized service center; unqualified servicing is dangerous. This air…
-
С BEFORE CALLING FOR SERVICE
Before calling for service, please check the following malfunctions and correct as needed. Should this fail to remedy the malfunction, contact your nearest authorized service center for qualified assistance. is too low. PROBLEM CAUSE SOLUTION e Unit does not operate. Power failure. Q Check main…
-
PROBLEM
CAUSE SOLUTION e Unit does not respond properly to remote control command. IR signal does not reach unit. Distance between remote control and unit is too great or remote control unit is aimed at improper angle. IR receiver on unit is exposed to strong light source. Check for obstruction between unit…