CENTRAL HEATING
-
INTRODUCTION
1 COMPONENTS FOR CENTRAL HEATING SYSTEM 2 HYDRAULIC SEPARATORS, DISTRIBUTION MANIFOLDS AND PUMPING STATIONS FOR CENTRAL HEATING 3 DIRT SEPARATOR FILTERS AND AIR VENT VALVE 4 ADJUSTMENT AND MANAGEMENT DEVICES 5 BALANCING DEVICES 6 COMPONENTS FOR PLUMBING SYSTEMS 7 ANTI-POLLUTION DEVICES 8 “TIEMME…
-
DISCOVER THE
TIEMME RANGE AND DOWNLOAD THE TECHNICAL DOCUMENTATION
-
“Everyone, with their skills and experience, has always been essential to our company
It is something precious that paves the way to a better understanding of all Customers’ need, be them in Italy or abroad, through targeted and innovative services and products”. The President Giuliano Gnutti
-
The Gnuti Cirillo Group has been a leading entrepreneurial business from the 50s, with a well-rooted activity all over the territory. A cluster of companies leaders in the technical-production chain, turning raw material into a fine product. A perfect union between tradition, professionalism…
-
TIEMME Raccorderie was founded 80s as a manufacturer and distributor of fittings, brass valves
and pipes. In the 1994 it joined the Gnutti Group, when the company was facing a radical change. The 2000s represent a phase of further growth and evolution for the company through the development of integrated systems in the HVAC industry. In 2012, “Tiemme Lab” was founded in Castagneto an…
-
The company is based in Castegnato (Brescia) and operates in two adjacent plants, one of approximately 7.000 m2 covered, where the production department with transfer machines and offices are located, the other with an area of 15.000 m2 where the warehouses and the PEX department for the production…
-
ROMANIA
Branch office Bucharest SPAIN Branch office Valencia ITALY TIEMME RACCORDERIE SPA GREECE Branch office Athens
-
TIEMME,
QUALITÀ CERTIFICATA TIEMME,CERTIFIED CERTIFIED QUALITY TIEMME, QUALITY ITALY BELGIUM ITALY UKRAINE RINA REGISTRO NAVALE ITALIANO POLITECNICO DI MILANO FONDAZIONE LABORATORIO PROVE MATERIE PLASTICHE ITALY ISTITUTO GIORDANO ITALY ICIM ITALY ISTITUTO NAZIONALE ASSICURAZIONE INFORTUNI SUL LAVORO…
-
NEW
3154 TM-MAG EVO Under-boiler magnetic dirt separator filter with by-pass PAGE 60 3155 TM-MAG EVO Proportional dispenser of polyphosphates in crystals with shut-off valve and integrated filter supplied with recharge PAGE 64 3157KIT 2 pieces kit: Under-boiler magnetic dirt separator filter TM-MAG EVO…
-
INTRODUCTION
A Life-changing design choices 2 B The heating system 3 C The technical team 4 D Tiemme Technical Service 5 E Tiemme LAB 6 F Tiemme BIM 7
-
A LIFE-CHANGING DESIGN CHOICES
80% of the annual energy we consume in our homes is linked to the production of hot water for heating and domestic use and energy spent for cooling rooms in the summer season. This percentage may increase or decrease according to the climate zone of the user and their personal choices, which…
-
B THE HEATING SYSTEM
DEFINITION ENERGY SYSTEMS The heating system is a technological system used to heat or cool the environment. Heating systems shall include: • All plants for the environmental heating, for the environmental heating plus the production of domestic hot water or also for the production of domestic hot…
-
C THE TECHNICAL TEAM
Tiemme strongly believes that the a support service for the design phase is critical for installers and professionals. The company also includes a department solely devoted to the design and quote of radiant systems, metering systems, and thermal center. Highly qualified and experienced operators in…
-
D TIEMME TECHNICAL SERVICE
Tiemme Technical Service (TTS), is a service guaranteed by Tiemme and provided thanks to many professional partners collaborating with us to create a competent and available support network. TTS can satisfy any request concerning Tiemme’s sector of operations, from single product installation to…
-
E TIEMME LAB
WE SHARE EXPERIENCE TO GROW TOGETHER The training center Tiemme LAB, is Tiemme's pride and joy. This important driver of innovation opened in 2012 and unveils for professionals operating in the sector Tiemme's wide range of solutions and an up-to-date selection of new products and technology.…
-
F TIEMME BIM
BUILDING INFORMATION MODELING WHAT IS BIM? BIM stands for “Building Information Modeling”, a digital process that takes place over the entire life span of the building (from design to maintenance). It allows to interact with other agents involved in the production chain through a smart digital…
-
COMPONENTS FOR CENTRAL HEATING SYSTEM 01A Safety and control components Safety valves 10 Safety unit 14 Thermometer and manometer 14 Pressure relief valves 15 Fuel shut-off valve 16 Temperature relief valve 17 INAIL instrument manifold 18 Pressure switches and safety thermostats 20 Safety valves for…
-
When the set pressure is reached the safety valves allow
to open and thus drain the water from the system so as to prevent the pressure from reaching dangerous limits for the heat generator and for the components. Tiemme safety valves comply with Directive 97/23/EC (PED - Pressure Equipment Directive) and are used for pressure control on heat generators…
-
1927 1917-1927 - Safety valve female connections Safety valve female connections TECHNICAL SPECIFICATIONS • Min operating temperature: -5°C • Max operating temperature: 120°C • Nominal pressure: PN10 • Body material: Brass CW617N • Opening overpressure: 10% • Connection threads: ISO 228 female Code…
-
1917M
1927M 1917MAN 1927MAN Safety valve female connections with increased outlet TECHNICAL SPECIFICATIONS • Min operating temperature: -5°C • Max operating temperature: 120°C • Nominal pressure: PN10 • Body material: Brass CW617N • Opening overpressure: 10% • Connection threads: ISO 7 female TECHNICAL…
-
1918MAN
1928MAN 1916 Temperature and pressure safety valve male/copper pipe outlet connection Safety valve male-female connections with 1/4” pressure gauge connection TECHNICAL SPECIFICATIONS • Min operating temperature: -5°C • Max operating temperature: 120°C • Nominal pressure: PN10 • Body material: Brass…
-
SAFETY UNIT
3175CT 3175ISOL Safety unit with insulation for wood-fired boilers Code Type 319 0010 319 0009 Price € Safety unit with insulation for wood-fired boilers Unit/Box Code Type Price € Unit/Box 1” - 1,5 bar 1/5 319 0003 1” - 1,5 bar 1/5 1” - 3 bar 1/5 319 0001 1” - 3 bar 1/5 VIDEO TUTORIALS Safety unit…
-
PRESSURE RELIEF VALVES
Tiemme pressure relief valves are self-regulating valves allowing the system pressure to be kept constant within specified limits by discharging the amount of fluid set by adjusting the shutter position. The force is applied directly by means of a spring (direct action). Once the pressure reference…
-
FUEL SHUT-OFF VALVE
The fuel shut-off valve, used in heating systems (central heating), intercepts the fuel flow to the burner to prevent the water temperature in the system delivery circuit from reaching the sensor calibration value. • INAIL approved and calibrated (ex ISPESL) • Complies with PED Directive 2014/68/EU…
-
TEMPERATURE RELIEF VALVE
The temperature relief valve, used in heating systems (central heating), allows the water to be drained when the set temperature is reached, preventing overheating. • INAIL approved and calibrated (ex ISPESL) • Complies with PED Directive 2014/68/EU, identification number CE1115. • Compliant with “R…
-
INAIL INSTRUMENT MANIFOLD
The instrument manifold compactly combines all INAIL components and accessories listed in the “R Collection” as mandatory instruments for the safety, protection and control of central heating systems above 35kW. The devices the manifold is made of are PED certified or INAIL compliant. INSTALLATION…
-
INAIL INSTRUMENT MANIFOLD
1923 7169 Pressure gauge cock, malefemale connector with stuffing box and bleeder bore. Thermoplastic handle INAIL instrument manifold TECHNICAL SPECIFICATIONS • Manifold body: S195T painted steel • Main connections: threaded with 1”1/4, 1”1/2, 2” unions and flanged (PN 16) DN50, DN65 and DN80 •…
-
PRESSURE SWITCHES AND SAFETY THERMOSTATS
2074MIN 2076 Manual reset minimum pressure switch, IP44 Code Type 075 0069 0.5 ÷ 2.5 Bar Price € Unit/Box 1/20 2074MAX Manual reset maximum pressure switch, IP44 Code Type 075 0068 2 ÷ 5.5 Bar Price € Adjustable immersion thermostat TECHNICAL SPECIFICATIONS • Includes sheath with 1/2” thread •…
-
SAFETY VALVES FOR WATER HEATER
1919 1929 Safety valves for water heater TECHNICAL SPECIFICATIONS • Max operating temperature: 120°C • Nominal pressure: PN10 • Body material: Brass CW617N • Connecting threads: ISO 228 male-female Code Type Calibration 193 0002 1/2" 8.5 bar 01A Safety valves with handle for water heater TECHNICAL…
-
3160K
Tiemme automatic filling unit art. 3160K is a device consisting of a pressure reducing valve with a compensated seat (1), inlet filter (2), shut-off cock (3), and a check valve (4), which is installed on the water supply pipe in heating systems, it has the main function to keep the system pressure…
-
3170 Automatic filling unit with double shut-off and non-return valve for closed circuit heating systems TECHNICAL SPECIFICATIONS • Adjustment range: 1-6 bar (Factory setting 1.5 bar) • Max. Inlet pressure: 16 bar • Max operating temperature: 65°C • Body material: Brass CW617N • Pressure gauge: 1/4”…
-
WITH DISCONNECTOR
The filling unit art. 3163 is used to automatically fill and refill water in the closed-circuit heating system, allowing the pressure in the circuit to be regulated. COMPONENT DESCRIPTION A filling unit is particularly useful for compensating the pressure drops due to the release of air from the…
-
WATER TREATMENT
The water filling and treatment unit art. 3164 is used to automatically fill and refill the water in the closed-circuit heating system, allowing the regulation of the pressure in the circuit, as well as the water treatment of the system. COMPONENT DESCRIPTION Installed on the water supply pipe, it…
-
WATER TREATMENT
3164 3164RA Compact automatic water filling and treatment unit with BA-type disconnector and insulation TECHNICAL SPECIFICATIONS • Adjustment range: 1.5 - 5.5 bar (Factory setting 1.5 bar) • Max. Inlet pressure: 10 bar • Max operating temperature: 30 (inlet) °C/ 65 (outlet) °C • Body material…
-
WITH DISCONNECTOR AND WATER TREATMENT - ACCESSORIES AND SPARE PARTS
3163CA Disconnector unit cartridge Code Type 317 0026 for art. 3163 - 3164 Price € Unit/Box 1/1 3163CC Wrench for cartridge removal disconnector unit Code Type 317 0022 for art. 3163 - 3164 Price € Unit/Box 1/50 3163CR Wrench for pressure reducing valve removal and disconnector unit cover cap Code…
-
HYDRAULIC SEPARATOS, DISTRIBUTION MANIFOLDS AND PUMPING STATIONS FOR CENTRAL HEATING SYSTEM 02A Introduction Hydraulic units for central heating system 30 02B Hydraulic separators Hydraulic separators - introduction 31 Steel hydraulic separators 32 Brass hydraulic separators 35 02C Manifolds for…
-
02A
HYDRAULIC UNITS FOR CENTRAL HEATING SYSTEM A good solution to control and distribute fluid in the system is to use specific hydraulic mixing units for boiler rooms, also called central heating system, with distribution manifolds. This chapter describes a full range of solutions for fluid management…
-
HYDRAULIC SEPARATORS - INTRODUCTION
The hydraulic separator is used to make the primary circuit (heat generator) totally independent from the secondary circuit (utilities), thus compensating for possible differences in the flow rate or for required pressure drop, and preventing installed series of circulating pumps to affect each…
-
3167ISOL
ADVANTAGES / STRENGTHS • • • • • Separating function; Dirt separating function; Available with or without insulation shell; Professional deaerator (art. 1896); Can be turned in a magnetic version with 3144MAG accessory (art. 3165 - art. 3165ISOL). 3165 Threaded hydraulic separator TECHNICAL…
-
MAGNETIC PRODUCTS
ADVANTAGES / STRENGTHS • • • • • ACCESSORIES AND SPARE PARTS Separating function Dirt separating function Magnetic function Available with or without insulation shell Professional deaerator (art. 1896); 3144MAG Well kit with magnet 3144 Threaded magnetic hydraulic separator Code Type 316 0105 1/2”…
-
DESCRIPTION OF COMPONENTS
-
BRASS HYDRAULIC SEPARATORS
ADVANTAGES / STRENGTHS 7166 109 DIMENSIONS • Extremely compact; • Can be complemented with Tiemme central system brass manifolds; • Comes with insulation shell; • Available with integrated shut-off valve (art. 7167). 95 02B 7166 Hydraulic separators with insulation shell 7167 109 DIMENSIONS Section…
-
таблицы и схемы — в просмотре
-
STEEL MANIFOLDS
In order to meet any system need, Tiemme offers a series of steel compact manifolds to complement different pumping stations. Used in cooling and/or heating systems, they enable different thermal configurations in different environments, with only one heat generator or chiller, thus offering a…
-
Tiemme modular brass manifolds for central system are
the result of a company's project aiming to create a unique and adaptable component that could be offered to their customers. Central system manifolds are used in climate control systems that require different heating and cooling operations in different environments. The heat generator (boiler…
-
ADVANTAGES / STRENGTHS
Tiemme brass manifolds 5538G and 5540G are designed to offer a number of advantages, including: Easy installation Installation occurs with specific wall fixing brackets (included) on which the manifold is screwed Ball valve Specifically made to optimize manifold installation and maintenance…
-
5538G2M3
5538G3M4 Modular brass manifold for central heating system with ball valves, insulation shell and fixing brackets. 125 mm spacing, fittings with flat seat and 1”1/2 loose nut No. circuits Flow rate Price € Unit/Box 557 0368 2”1/2 2 2.2 (m3/h) 1/1 557 0483 2” 1/2 2 2.2 (m3/h) 1/1 Code Section…
-
5538G4M6
5540G2M4 Modular brass manifold for central heating system with ball valves, insulation shell and fixing brackets. 125mm spacing, fittings with flat seat and 1”1/2 loose nut Code Section Modular brass manifold for central heating system with ball valves, insulation shell and fixing brackets. 125 mm…
-
5540G3M6
5540G4M8 Modular brass manifold for central heating system with ball valves, insulation shell and fixing brackets. 125 mm spacing, fittings with flat seat and 1”1/2 loose nut Code Section No. circuits Flow rate Price € Unit/Box Modular brass manifold for central heating system with ball valves…
-
5540G5M10
5540G6M12 Modular brass manifold for central heating system with ball valves, insulation shell and fixing brackets. 125 mm spacing, fittings with flat seat and 1”1/2 loose nut Code Section No. circuits Flow rate Price € Unit/Box Modular brass manifold for central heating system with ball valves…
-
5540G7M14
Modular brass manifold for central heating system with ball valves, insulation shell and fixing brackets. 125 mm spacing, fittings with flat seat and 1”1/2 loose nut Code Section No. circuits Flow rate Price € Unit/Box 557 0472 2”1/2 7 6.5 (m3/h) 1/1 557 0511 2”1/2 7 6.5 (m3/h) 1/1 557 0512 2”1/2 7…
-
5538G - 5540G
5538G - 5540G GUIDE TO FITTINGS INSTALLATION 125 G 1” Ø26,5 Wall installation is quick and easy, thanks to the specific adjustable brackets that can be screw-fixed onto the wall and to the manifold. Screw slots can be found directly on the manifold. With the ball valve installed on the manifold, it…
-
ACCESSORIES
1602 1552FD Female straight fitting for multilayer pipe Code Type Price € Male threaded nipple with flat seat Unit/Box Code Type 471 0086 1”1/2 x 1”1/2 160 0112 25 x 2.5 - 1" 5/50 160 0029 26 x 3.0 - 1" 5/100 160 0039 32 x 3.0 - 1" 5/50 Price € Unit/Box 2/30 1881 M/F reduction with O-ring for…
-
02DA
DN25 HYDRAULIC POWER UNITS DIRECT PUMPING STATION FOR HEATING SYSTEMS DN25 pumping station, art. 5535G, feeds high temperature circuits of heating systems, directly from manifold's connections, without changing the temperature of the incoming fluid. Two thermometers make it possible to check…
-
FIXED POINT MIXING UNIT FOR HEATING SYSTEMS
DN25 pumping station, art. 5535GPF, feeds high temperature circuits of heating systems, directly from manifold's connections, without changing the temperature of the incoming fluid. Two thermometers make it possible to check instantaneous flow and return temperature. A check valve is located on the…
-
MODULATING MIXING UNIT FOR HEATING SYSTEMS
DN25 pumping station, art. 5535G3P, feeds high temperature circuits of heating systems, directly from manifold's connections, without changing the temperature of the incoming fluid. Two thermometers make it possible to check instantaneous flow and return temperature. A check valve is located on the…
-
DIRECT PUMPING STATION FOR HEATING/COOLING SYSTEMS
DN25 pumping station, art. 5536G, is a model of 5535G series designed to create cooling systems. To this purpose, the station has an EPP insulation shell that can reduce the creation of steam on metal surfaces. The station feeds circuits of heating/cooling systems from a manifold connections…
-
MODULATING MIXING UNIT FOR HEATING/COOLING SYSTEMS
DN25 pumping station, art. 5536GS, is a model of 5535G3P series designed to create cooling systems. To this purpose, the unit has an EPP insulation shell that can reduce the creation of steam on metal surfaces. The unit feeds heating/cooling system circuits, directly from manifold connections…
-
DN32 HYDRAULIC POWER UNITS
DIRECT PUMPING STATION FOR HEATING/COOLING SYSTEMS DN32 pumping station, art. 5534G, feeds high temperature circuits of heating systems, directly from manifold's connections, without changing the temperature of the incoming fluid. Two thermometers make it possible to check instantaneous flow and…
-
DN32 HYDRAULIC POWER UNITS
MODULATING MIXING UNIT FOR HEATING/COOLING SYSTEMS DN32 pumping station, art. 5534G3P, feeds high temperature circuits of heating systems, directly from manifold's connections, without changing the temperature of the incoming fluid (function guaranteed by the mixing valve controlled by a servomotor…
-
ACCESSORIES FOR PUMPING STATIONS
5535DIFF 3880GSM Differential by-pass with 50-400 mbar settings. M25x1.5 fitting. (Can be used with any hydraulic power unit) Code Type 316 0029 50-400 mbar Price € Unit/Box 1/50 Mixing valve for servomotor controller (not included) To be complemented with servomotor 9562SERV Code Type 316 0031…
-
ACCESSORIES FOR PUMPING STATIONS
1665 3890PV Straight fitting with swivel nut and flat-sealing for multilayer pipe Price € Unit/Box Grundfos UPSM3 HYBRID 25/70 high efficiency pump with 130 mm spacing. 1”1/2 fitting on cast iron body HIGH-EFFICIENCY PUMP Code Type 165 0240 32 x 3.0 - 1"1/2 1/50 Code Type 165 0239 40 x 3.5 - 1”1/2…
-
HYDRAULIC UNITS FOR CENTRAL HEATING SYSTEMS
INSTALLATION EXAMPLES SINGLE-FAMILY SYSTEM Single-family radiant heating/cooling system with boiler and heat pump. Tiemme brass manifold, art. 5538G2M4, with Tiemme hydraulic separator, art. 7166. 40 60 °C 80 TERMOMETRO 20 100 conf e norme ISPESL recisione ±2°C °C 80 TERMOMETRO 20 100 conf e norme…
-
DIRT SEPARATOR FILTERS AND AIR VENTS 03A Magnetic dirt separator filters The reason behind filtration treatment in plants 58 Magnetic dirt separator filters 59 03B Polyphosphates proportional dispenser 64 03C Acid condensate neutralizer filters 65 03D Air vent valves New section Air in the systems…
-
THE REASON BEHIND FILTRATION TREATMENT IN PLANTS
The water circulating in heating and cooling systems is commonly subject to the presence of impurities (sand grains, residues resulting from installation and maintenance operations, rust flakes caused by oxidation and corrosion phenomena, etc.…). These impurities, if not properly removed, may cause…
-
“TM-MAG MINI” COMPACT FILTER FOR UNDER-BOILER INSTALLATION
The magnetic filter for under-boiler installation TM-MAG MINI ensures effective removal of impurities in heating circuits, thanks to the combined double action: • The neodymium magnet attracts ferrous particles by the action of the magnetic field; • The filter cartridge mechanically filters the…
-
“TM-MAG EVO” UNDER-BOILER FILTER
TM-MAG EVO filters out impurities in air conditioning systems thanks to the combined action of magnets, a filtering net, a large sediment chamber: • The fluid is directed towards the powerful neodymium magnets that attracts and stops metallic impurities. • It then goes through the 800 μm stainless…
-
“TM-MAG ” UNDER-BOILER FILTER
The magnetic dirt separator filter for under-boiler installation TM-MAG ensures effective removal of impurities in heating circuits, thanks to the combined double action: • The neodymium magnet attracts ferrous particles by the action of the magnetic field; • The filter cartridge mechanically…
-
LINEAR FILTERS
The linear magnetic dirt separator filter ensures effective removal of impurities in heating circuits, thanks to the combined double action: • The neodymium magnet attracts ferrous particles by the action of the magnetic field; • The filter cartridge mechanically filters the impurities with a…
-
SWIVEL FILTER “TM-MAG PLUS”
The TM-MAG PLUS swivel magnetic filter combines effective debris separation by cyclonic action with a dual filtration step, first magnetic and then mechanical. The special inner insert, patented, is designed to direct the flow into a real vortex, so as to favor a first important purification…
-
03B
POLYPHOSPHATES PROPORTIONAL DISPENSER TIEMME ULISSE polyphosphates dispenser prevents the formation of scale in the sanitary system and/or in the devices connected to it. The dispenser must be installed on the supply pipe of the boiler or other equipment (water heater, washing machine, dishwasher)…
-
03C
ACID CONDENSATE NEUTRALIZER FILTERS TM-NEUTRIX is the TIEMME acid condensate neutralizer for condensation boilers. Condensation boilers are widely used for their simple installation, combined with high efficiency largely resulting from the recovering the energy contained in the combustion fumes…
-
AIR IN THE SYSTEMS: COMMON ISSUES
The presence of air in the systems is a common occurrence that requires particular measures in order to ensure a correct operation. The air that is not properly removed may cause different problems: NOISE IN PIPES, TERMINALS AND VALVES: The noise in the pipes occurs especially during the starting…
-
HIGH PERFORMANCE
This series of valves is characterized by their high air vent capacity and is equipped with a protective cap against sudden hot fluid spills. PRODUCT RANGE 1896 Nickel-plated automatic air vent valves The air in the system reduces the water level in the vent valve, which lowers the float and opens…
-
COMPACT HIGH PERFORMANCE
This series of valves is characterized by their compact size and by being fitted with a closure cap for the air ejection device. The gas expulsion device guarantees excellent performance and has been designed in such a way as to prevent any impurities present in the water from dirtying the sealing…
-
COMPACT
This series of valves is characterized by their compact size and by being fitted with a closure cap for the air ejection device. The air in the system reduces the water level in the vent valve, which lowers the float and opens the gas ejection device. Otherwise, if there is no air in the system, the…
-
AUTOMATIC AIR VENT
VALVES DEAERATORS COMPACT - SMALL DIAMETER Air vent valves with a small diameter art. 1900N34 and 1900G34 find their application in riser columns with narrow center distance (distance between pipes min. 34 mm), where other valves would not be used due to the larger overall dimensions. PRODUCT RANGE…
-
AIR VENT VALVES
FOR RADIATORS ACCESSORIES 3350 1901 Air vent valve for radiators Code Type 198 0021 198 0020 Price € Cut-off valve with o-ring sealing and brass shutter Unit/Box Code Type Price € Unit/Box 1/8” 10/500 198 0012 3/8” 10/300 1/4” 10/500 198 0009 1/2” 10/100 198 0015 3/8” 10/500 198 0023 M 1/2”- F 3/8”…
-
ADJUSTMENT AND MANAGEMENT DEVICES 04A Hydronic units Hydronic unit for HP - DHW management 74 Hydronic unit for double source management 75 04B Motorized ball valves 2/3-way ball valves 76 6-way ball valves 78 04C Thermostatic diverter/mixing valve 79 04D Anti-condensation valve 84 04E 86…
-
04A
HYDRONIC UNIT FOR HP - DHW MANAGEMENT The Hydronic unit art. 5532PDC is used in systems where the heat pump (HP) is the only generator available for heating/ cooling of rooms and for the production of domestic hot water (DHW). The 3-way valve diverts flow according to system demand. The presence of…
-
04A
HYDRONIC UNIT FOR DOUBLE SOURCE MANAGEMENT The hydronic unit art. 5532HYBRID is used in systems with at least two distinct generators, typically hybrid systems with heat pump (HP) and boiler. Regarding the automatic switching from one generator to another, the 3-way valve allows the carrier fluid to…
-
2/3-WAY BALL VALVES
2139 2134 2-way motorized ball valve, full port, female/female, for actuators with ISO5211 Price € Unit/Box 3-way diverter motorized ball valve - 3-union connections with servomotor. Also available with a 24Vac power supply Code Type 213 0104 1/2” 15/60 Code Type Power 213 0107 3/4” 10/40 213 0009…
-
2/3-WAY BALL VALVES
9536 Servomotor for by-pass zonevalve (art. 2136-2137); 90° bidirectional rotation, supplied with protection fuse. Case with protection rating IP44 Code Voltage Time Price € 213 0030 230 Vac 40 sec 1/8 213 0037 24 Vac 40 sec 1/8 2138 - 2133 TECHNICAL SPECIFICATIONS Unit/Box VIDEO TUTORIALS • 230 Vac…
-
6-WAY BALL VALVE
The 6-way ball valve art. 2130SM allows to manage in a synchronized way the 4 tubes of two different sources of the system (heating and cooling). It finds application in 4-tube systems for heating/cooling management, with a single terminal (fan coil, radiant ceilings). ACCESSORIES AND SPARE PARTS…
-
Tiemme 3-way valve art. 38.90VD for mixing/diverting flow
rates in heating and cooling systems. It carries out a constant proportional adjustment needing no electrical connections, thanks to the use of thermostatic heads with contact or immersion probe. Double function as diverter or mixer. INSTALLATION EXAMPLES PLANT SOLUTION 1: DIVERTER FUNCTION 3890VD…
-
3890VD
THERMOSTATIC DIVERTER/MIXING VALVE PLANT SOLUTION 3: MIXER FUNCTION 3890VD PLANT SOLUTION 5: DIVERTER / MIXER 3890VD 3890VD 1521CPKIT 3890TTVD 1570 3890TTVD Art. 1521CP Art. 1521CP 3890VD Boiler 1570 Fireplace stove 1570 1521CPKIT 3890TTVD Control of the return temperature in circuits with heating…
-
3890TTVD
PRODUCT RANGE Thermostatic head with remote probe for diverter/mixing valve 3890VD 3-way thermostatic diverter/ mixing valve for heating and cooling systems management. According to the direction, it works either as diverter or mixing valve. TECHNICAL SPECIFICATIONS • Max operating temperature: 100…
-
THERMOREGULATION
T_EXT RC _SA - CLIMATE CONTROL 5530E Temperature and humidity external probe Used in Climav 2.0 Building Management thermoregulation system to compensate in climate regulation. 5530M5 5530M6 RC_SA climate control allows to control fluid medium temperature in heating and climate regulation systems…
-
THERMOREGULATION
T_G T_P 5530E2 5530I9 Wall installation temperature environmental probe TECHNICAL SPECIFICATIONS • Size (LxHxP): 120 x 80 x 20 mm To be placed in each room and connected to Climav 2.0 Building Management system. Code Color Price € In-built temperature environmental probe. To be placed in 503 box.…
-
04D
AB A ANTI-CONDENSATION VALVE B AB Anti-condensation valve art. 4732 is used to protect the generator from the temperature of the return heat transfer fluid which is too low, thus preventing the appearance of condensation of the vapor contained in the fumes. The Tiemme valve independently regulates…
-
04D
ANTI-CONDENSATION VALVE PRODUCT RANGE 4732 Anti-condensation valve Other calibrations available as an option Code Type Price € Unit/Box 324 0017 1" 60°C 1/8 324 0018 1"1/4 60°C 1/8 324 0019 1"1/2 60°C 1/8 ACCESSORIES AND SPARE PARTS 1521CPKIT Union kit The kit includes: 3 tails, 3 nuts and 3 gaskets…
-
04E
DIFFERENTIAL BY-PASS VALVE ΔP The differential by-pass valves art. 6534G are generally used in systems subject to significant flow rate variations to allow the system circulator pump to work as close as possible to its nominal pressure head value and in this way ensure correct system functioning.…
-
BALANCING DEVICES 05A System balancing - Introduction 88 05B Static balancing valves (SBV) 90 05C Dynamic balancing valves (PICV) 94 valves with 05D Balancing differential pressure control (DPCV) 112 05E Balancing valves with differential pressure control (PIBCV) 117 05F Accessories for balancing…
-
05A
SYSTEM BALANCING - INTRODUCTION The correct operation of a thermal installation is closely linked to the balance of the distribution network. In fact, the design flow rate must be available to all delivery units, even those most at a disadvantage. A properly balanced system ensures: • ENERGY SAVING…
-
05A
SYSTEM BALANCING - INTRODUCTION PRODUCT RANGE 1) MANUAL STATIC FLOW RATE BALANCING Model 6535G page 93 6535DN page 93 Range 1/2" ÷ 2” DN65 ÷ DN200 Fittings Threaded Flanged Adjustment Calibration knob with “memory stop” function. Calibration when the system is running. Calibration knob with “memory…
-
WHAT ARE STATIC BALANCING VALVES FOR?
WHAT IS THE AUTHORITY OF A VALVE? Static balancing valves are valves in which the valve stem position can be adjusted to create a load loss in the system and stabilize the flow rate occurring on a given branch. They are therefore comparable to lockshield valves. The flow rate is set during…
-
FLOW RATE CALCULATION
To calculate the flow rate, balancing valves use the Venturi principle. This principle demonstrates how the pressure of a fluid Aug stream increases as the speed Capdecreases. Therefore, if there is a section decrease (as shown in the figure), there will be rubber a certain speed and Seal a certain…
-
INSTALLATION EXAMPLES
Diagram 1: Balancing individual autonomous zones and risers CALDAIA BURNER Diagram 2: Primary and secondary side system balancing Dp kW.. 7 TO USERS Q 012.31MWh 012.31MWh MID 004 MID °C TERMOMETRO conf e norme ISPESL recisione ±2°C °C TERMOMETRO MID conf e norme ISPESL recisione ±2°C 120 60 °C…
-
ADVANTAGES / STRENGTHS
CALIBRATION • • • • The balancing valve can be adjusted from 0.0 (valve fully closed) to a value that varies according to valve diameter. The number before the decimal point represents the number of full revolutions that the knob performs, the number after the decimal point is a micrometric value…
-
The Tiemme PICV (Pressure Independent Control Valves)
dynamic balancing valves keep the design flow rate constant as the operating conditions of the hydraulic circuit vary. The desired flow rate value is set by means of an adjustable flow cartridge. Designed to ensure the flow rate to individual utilities and on risers, Tiemme dynamic balancing valves…
-
INSTALLATION
Tiemme dynamic balancing valves are typically installed on the return branch of the hydraulic circuit. Placing a suitable filter before the valve is recommended to protect the balancing device from any dirt that may impair its proper operation. Tiemme dynamic balancing valves can be installed on…
-
TIEMME-BASIC
6541CC TIEMME-BASIC flow rate stabilizers with internally-adjustable cartridge and fittings for pressure plugs (optional) Accessories: 6542PP - 6535ET For codes see page 119 Code Cartridge size Range ΔP Cartridge colour Flow rate l/h Price € Unit/Box 651 0753 20 - 130 kPa Grey 29 - 155 1/10 651 0754…
-
TIEMME-BASIC
GUIDE TO CHOOSING CARTRIDGE WITH INTERNAL ADJUSTMENT FLOW RATE ADJUSTMENT Cartridge adjustment using 6 mm Allen key. The calibration operations must be carried out at installation before filling the system l/sec l/h 0.0081 29.2 0.0133 47.9 0.0175 0.0222 DN20 cartridges for Tiemme-Basic valves…
-
TIEMME-EASY
6542CC TIEMME-EASY flow rate stabilizers with externally-adjustable cartridge, with pressure plugs Accessories: 6543CH - 6535ET Spare parts: 6542PP For codes see page 119 Code Range ΔP Cartridge colour Flow rate l/h 651 0786 17 - 210 kPa Black 100 - 412 1/10 651 0787 17 - 210 kPa Green 157 - 609…
-
GUIDE TO SELECTING EXTERNALLY-ADJUSTABLE CARTRIDGES FLOW RATE ADJUSTMENT Cartridge adjustment using Tiemme key art. 6543CH. Setting l/h 0.0278 100 1.0 0.0876 315 0.0299 108 1.1 0.0884 318 3.8 0.0321 116 1.2 0.0906 326 3.9 0.0343 123 1.3 0.0907 327 0.0364 131 1.4 0.0928 334 0.0386 139 1.5 0.0938 338…
-
GUIDE TO SELECTING EXTERNALLY-ADJUSTABLE CARTRIDGES FLOW RATE ADJUSTMENT Cartridge adjustment using Tiemme key art. 6543CH. 100 l/sec l/h 0.0383 138 0.0416 150 0.0449 0.0483 Setting Setting l/sec l/h 1.0 0.128 460 1.1 0.130 468 162 1.2 0.131 472 3.8 174 1.3 0.134 484 3.9 0.0516 186 1.4 0.135 485…
-
GUIDE TO SELECTING EXTERNALLY-ADJUSTABLE CARTRIDGES FLOW RATE ADJUSTMENT Cartridge adjustment using Tiemme key art. 6543CH. DN20 cartridge for Tiemme-Easy valves DN15-DN20-DN25 Small Pressure range ΔP: 17-200 kPa l/sec Setting l/sec l/h Setting 0.0767 276 1.0 0.113 406 1.0 0.0813 293 1.1 0.119 427…
-
GUIDE TO SELECTING EXTERNALLY-ADJUSTABLE CARTRIDGES FLOW RATE ADJUSTMENT Cartridge adjustment using Tiemme key art. 6543CH. 102 l/sec l/h DN50 cartridge for Tiemme-Easy valves DN40-DN50 Pressure range ΔP: 20-400 kPa Setting l/sec l/h Setting 0,149 535 1.0 0.883 3180 1.0 0.220 793 1.1 1.14 4100 1.1…
-
TIMME-AUTO
6542CCS TIEMME-AUTO flow rate stabilizer configured for servomotor or actuator connection, with pressure plugs Accessories: 6543CH (For Green 0, Green 1, Green 2) - 6545CH (For Green 3) - 6542SERV (For Green 0, Green 1)- 6542SERV2 (Green 3)- 6542ATT (For Green 0, Green 1, Green 2) - 6535ET Spare…
-
GUIDE TO SELECTING EXTERNALLY-ADJUSTABLE CARTRIDGES FLOW RATE ADJUSTMENT Cartridge adjustment using Tiemme key art. 6543CH. DN20 cartridge for Tiemme-Auto valves DN15-DN20-DN25 Small Pressure Range ΔP: 16-200 kPa 104 l/h Setting l/sec Green 0 l/h Setting Green 1 - - 1.0 0.0178 64 1.0 0.0103 37 1.1…
-
GUIDE TO SELECTING EXTERNALLY-ADJUSTABLE CARTRIDGES VALVE DN25 LARGE-DN32 FLOW RATE ADJUSTMENT Cartridge adjustment using Tiemme key art. 6543CH. DN40 cartridge for Tiemme-Auto valves DN25 LARGE-DN32 Pressure range ΔP: 16-800 kPa l/sec Setting Green 2 l/sec l/h Setting Green 3 0.240 865 1.0 0.528…
-
TIEMME-EASY HIGH FLOW RATE
-
TIEMME-EASY HIGH FLOW RATE (DN65 - DN80)
FLOW RATE SELECTION GUIDE FLOW RATE ADJUSTMENT Cartridge adjustment using Tiemme key art. 6543CH. Calibration accuracy ±5% of controlled flow rate or ±2% of maximum flow. Valves DN65-DN80 Cartridge SH. 3.0 Pressure range ΔP: 30-600 kPa Valves DN65-DN80 Cartridge SH. 3.1 Pressure range ΔP: 30-600 kPa…
-
TIMME-EASY HIGH FLOW RATE (DN80 - DN100)
FLOW RATE SELECTION GUIDE FLOW RATE ADJUSTMENT Cartridge adjustment using Tiemme key art. 6543CH. Calibration accuracy ±5% of controlled flow rate or ±2% of maximum flow. 108 Valves DN80-DN100 Cartridge SH. 4.1 Pressure range ΔP: 30-600 kPa Valves DN80-DN100 Cartridge SH. 4.2 Pressure range ΔP…
-
TIMME-EASY HIGH FLOW RATE (DN125 - DN150)
FLOW RATE SELECTION GUIDE FLOW RATE ADJUSTMENT Cartridge adjustment using Tiemme key art. 6543CH. Calibration accuracy ±5% of controlled flow rate or ±2% of maximum flow. Valves DN125-DN150 Cartridge SH. 5.1 Pressure range ΔP: 30-600 kPa Valves DN125-DN150 Cartridge SH. 5.2 Pressure range ΔP: 35-600…
-
TIMME-EASY HIGH FLOW RATE (DN200 - DN250)
FLOW RATE SELECTION GUIDE FLOW RATE ADJUSTMENT Cartridge adjustment using Tiemme key art. 6543CH. Calibration accuracy ±5% of controlled flow rate or ±2% of maximum flow. 110 Valves DN200-DN250 Cartridge SH. 6.2 Pressure range ΔP: 35-600 kPa l/sec l/h Setting l/sec l/h Setting 9.21 9.69 10.2 10.8…
-
TIEMME-AUTO HIGH FLOW RATE
OPERATING CURVES 100 90 Self-calibrating actuators; Keeps the flow rate accurately constant; Applicable on risers; Potential for an analogue 0-10 V or 4/20 mA or digital 2position 3-point adjustment; • Supplied with servomotor. Meal % ADVANTAGES / STRENGTHS • • • • Signal proving (V) SM linear flow…
-
DIFFERENTIAL PRESSURE CONTROL (DPCV)
Balancing valves with Tiemme differential pressure control art. 6538 are compact valves designed for differential pressure control at various points in the system. Thanks to the combined action of diaphragm and spring, they are able to react to the pressure variations generated within the system…
-
DIFFERENTIAL PRESSURE CONTROL (DPCV)
Diagram 1: Riser balancing function Diagram 2: Manifold balancing function RADIANTE BT 6538 6538 6538 6539 6539 PRODUCT RANGE 6538 Balancing valve with differential pressure control Accessories: 6543CH - 6539 - 6535ET Spare parts: 6542PP For codes see page 119 Code Valve body Cartridge size Range ΔP…
-
DIFFERENTIAL PRESSURE CONTROL (DPCV)
(DN15-DN20-DN25 SMALL) FLOW RATE SELECTION GUIDE DN20 cartridge - for valve DN15-DN20-DN25 Small - Pressure range ΔP: 5-50 kPa 1.2 1.4 1.6 1.8 2 2.2 2.8 3 3.5 1030 1150 1270 1390 1690 1970 1100 1220 1340 1640 1920 930 1050 1170 1290 1590 1870 770 880 1000 1120 1240 1540 1820 1070 1190 1490 1770 1020…
-
DIFFERENTIAL PRESSURE CONTROL (DPCV)
(DN25 LARGE - DN32) FLOW RATE SELECTION GUIDE DN40 cartridge - for DN25 large-DN32 Valve - Pressure Range ΔP: 5-60 kPa ΔP (kPa) 1.2 1.4 1.6 1.8 2 1720 1400 1090 1720 1400 1090 1720 1430 1290 1150 1020 2010 1870 1730 1590 1450 1310 1170 1030 2480 2340 2190 2050 1910 1760 1620 1480 1330 1190 1040 2970…
-
DIFFERENTIAL PRESSURE CONTROL (DPCV)
(DN40 - DN50) FLOW RATE SELECTION GUIDE DN50 cartridge - for DN40-DN50 valve - Pressure range ΔP: 5-100 kPa 1 1.2 1.4 1.6 1.8 2 2.2 ΔP (kPa) 2.8 3 3.5 4 4.5 5 5 3670 3670 3670 3670 3900 5550 7130 8920 11000 10 1670 1670 1670 1720 2830 4300 5800 7490 9400 11700 1350 2400 3800 5270 6930 8800 11000…
-
05E
BALANCING VALVES WITH DIFFERENTIAL PRESSURE CONTROL (PIBCV) The Tiemme differential pressure control valves art. 6540, are compact valves designed for differential pressure control at different points of the system, in particular for flow control on multi-zone radiant system manifolds, thermostatic…
-
05E
BALANCING VALVES WITH DIFFERENTIAL PRESSURE CONTROL (PIBCV) PRODUCT RANGE 6540 Balancing valve with differential pressure control and on/off actuator Accessories: 6543CH - 6542ATT - 6535ET Spare parts: 6542PP For codes see page 119 Code Type Range ΔP Flow rate l/h Price € Unit/Box 651 0920 1/2” 3…
-
05F
ACCESSORIES FOR BALANCING VALVES 6535ISOL 6535PP Foam PEX insulation for balancing valve 6535G For valve 6535G Code Type 651 0229 Pair of red and blue pressure plugs For valves 6535G - 6535DN - 6539 Price € Unit/Box Code Type 1/2” 1/10 651 0235 1/4” 651 0230 3/4” 1/10 651 0231 1” 1/10 651 0232 1”1/4…
-
05F
ACCESSORIES FOR BALANCING VALVES 6542ATT 6536 Electrothermal actuator for TIEMME-AUTO balancing valve. Fitting M30x1.5 For 6542CCS valve (Green 0 - Green 1 - Green 2) - 6540 Code Type Price € Unit/Box 651 0814 NC; on/off (230 VAC) 1/1 651 0815 NC; on/off (24 VAC) 1/1 651 0816 NC; 0÷10V (24 VAC) 1/1…
-
05G
MULTIFUNCTION KIT FOR AIR TERMINAL UNITS The multifunction kit art. 3162 allows adjustment, commissioning and flushing/servicing of terminal units (fan convectors, fan coils etc) within a heating, ventilation and air-conditioning system. OPERATION/CONFIGURATIONS The kit should be installed upstream…
-
COMPONENTS FOR PLUMBING SYSTEMS 06A Filters Why filtration is so relevant 124 Self-cleaning filters 125 Strainers 128 06B Pressure reducing valves 129 06C Thermostatic mixing valves 133 06D Multifunction thermostatic regulator 135 06E Anti-scald thermostatic kit with recirculation 136 06F DHW…
-
WHY FILTRATION IS SO RELEVANT
Regardless of its origin, the water contains foreign bodies such as sand grains and other solid impurities, which inside hydraulic systems may cause different problems, in particular: • Corrosion phenomena caused by the deposition of impurities on the walls of the pipes (corrosion by differential…
-
Once the water has been introduced into the self-cleaning
filter, it flows through the filter element, releasing particles with a diameter greater than 100 μm on the outer surface of the element. The filtered water is then sent out to the filter. The cylinder head, made of brass, is complete with union connections that facilitate installation. A cup is…
-
3135N
3136N Self-cleaning filter with M/M union connections TECHNICAL SPECIFICATIONS • Degree of filtration: 100 μm • Collection cup material: transparent polycarbonate • Body material: Brass CW617N nickel-plated • Max operating pressure: 16 bar • Max operating temperature: 65°C • Connection threads: ISO…
-
3120N
Self-cleaning filter with F/F connections ACCESSORIES AND SPARE PARTS 3145 Unions kit for self-cleaning filters 3131-3136 TECHNICAL SPECIFICATIONS • Degree of filtration: 100 μm • Collection cup material: Brass CW617N • Body material: Brass CW617N nickel-plated • Max operating pressure: 16 bar • Max…
-
STRAINERS
The shape of the strainers allows the deposit of impurities on the bottom of the cartridge holder seat and simple and fast maintenance thanks to the possibility of unscrewing the closure cap and extracting the filter mesh. PRODUCT RANGE 3670 Y strainer The Tiemme strainer is characterized by its…
-
Pressure reducing valves are mainly used in the domestic
water circuits, in order to reduce and maintain the pressure of the water coming from the public water distribution system at a constant value. This prevents pressure variations that could potentially damage components or lead to improper water distribution. The compensated seat ensures that the set…
-
USEFUL TIPS - DETERMINING THE CORRECT
PRESSURE REDUCTION RATIO CAVITATION DIAGRAM 25 22.5 20 DANGER OF CAVITATION UPSTREAM PRESSURE (bar) 17.5 15 OPTIMAL ZONE 12.5 10 5 NON-FUNCTIONING ZONE DANGER OF CAVITATION OPTIMAL NON-FUNCTIONING 5 12.5 When the ratio between the upstream pressure and the downstream pressure exceeds 3:1, the…
-
3100N
3108N TECHNICAL SPECIFICATIONS • Adjustment range: 1-4 bar (Factory setting 3 bar) • Max inlet pressure: 15 bar • Max operating temperature: 80°C • Body material: Brass CW617N nickel-plated • Connection threads: ISO 228 female • Pressure gauge connection: 1/4” TECHNICAL SPECIFICATIONS • Adjustment…
-
Pressure reducing valve, with diaphragm, F-F unions ACCESSORIES AND SPARE PARTS 2080 Manometer radial connection Ø50 TECHNICAL SPECIFICATIONS • Adjustment range: 1-6 bar (Factory setting 3 bar) • Max inlet pressure: 16 bar • Max operating temperature: 65°C • Body material: Brass CW617N nickel-plated…
-
06C
THERMOSTATIC MIXING VALVES The thermostatic mixing valve for domestic installations allows the instantaneous mixing of the inlet fluids, thus ensuring stability on the set value of the temperature of the outlet fluid, both when the flow rate taken by the different users varies, and when the pressure…
-
06C
THERMOSTATIC MIXING VALVES 4737 4738KIT Chrome-plated female thermostatic adjustable mixing valve for DHW TECHNICAL SPECIFICATIONS • Compliance with: UNI EN 1111 • Temperature range: 30÷55°C • Max operating pressure: 10 bar • Max inlet temperature: 90°C • Body material: Brass CW617N • Handle…
-
06D
MULTIFUNCTION THERMOSTATIC REGULATOR The multifunction thermostatic regulator is used to automatically balance the recirculation circuits of DHW distribution systems, so as to ensure that all sections of the mains reach the set temperature value. It is also equipped with a by-pass device, which…
-
06 E
ANTI-SCALD THERMOSTATIC KIT WITH RECIRCULATION The anti-scald thermostatic kit with recirculation art. 4738KR provides an easy connection between the DHW distribution system, the accumulation storage and the recirculation system. Complete with 3 shut-off valves and 3 check valves, it allows simple…
-
5,7°C 10°C
06F DHW TEMPERATURE MANAGEMENT AND DISINFECTION ANTI-LEGIONELLA THERMAL DEVICE WHAT IS LEGIONELLA? Legionella is a bacterium naturally present in water (rivers, lakes, wells..). It can be found inside water mains and is able to survive the normal water potabilization treatments. Its presence is not…
-
06 F
DHW TEMPERATURE MANAGEMENT AND DISINFECTION ANTI-LEGIONELLA THERMAL DEVICE LEGIO-TIEMME is a device used for the management of the DHW temperature controlled by the control unit that acts on the servo-control mounted on board. In addition to the management of the outlet temperature for the user, the…
-
06 F
DHW TEMPERATURE MANAGEMENT AND DISINFECTION ANTI-LEGIONELLA THERMAL DEVICE 4723CENTR LEGIO-TIEMME control unit for the management of the domestic installation and antiLegionella treatment TECHNICAL SPECIFICATIONS • Power supply: 85-230 Vac • Absorption: < 5 W • Protection fuse: 1A • Graphic display…
-
06 G
WATER HAMMER ARRESTOR In water systems where ball valves, mixing valves, solenoid valves or other devices for rapid interception of the fluid are present, it is frequent to incur the phenomenon of “water hammer” caused by a sudden deceleration and/or acceleration of the fluid which generates…
-
ANTI-POLLUTION DEVICES 07A Anti-pollution devices - introduction 142 07B Check valves 143 07C Backflow preventers 145
-
07A
ANTI-POLUTION DEVICES - INTRODUCTION SCOPE REGULATORY REFERENCE Check valves and backflow preventers are devices designed to prevent pollution from the water supply due to the accidental return of contaminated fluid from the downstream system (USERS), due to pressure variations in the distribution…
-
07B
CHECK VALVES UNCONTROLLABLE 3500 3600 Check valve YACHT female/ female ISO 228 with polyamide shutter Code Type 350 0003 350 0004 Price € Check valve YACHT female ISO 228 with polyamide shutter and stainless steel filter Unit/Box Code Type 1/2” 15/60 350 0053 1/2” 8/80 3/4” 12/48 350 0037 3/4” 8/48…
-
07B
CHECK VALVES CHECK VALVES ACCESSORIES CONTROLLABLE (EA TYPE) 3510 Stainless steel filter for check valve Code Type 350 0054 1/2” 1/100 350 0044 3/4” 1/50 350 0029 1” 1/25 350 0038 1”1/4 1/20 350 0056 1”1/2 1/10 350 0052 2” 1/5 350 0064 2”1/2 1/4 350 0063 3” 1/3 350 0046 4” 1/2 07B Price € Unit/Box…
-
07C
BACKFLOW PREVENTERS The BA-type preventers are characterized by a controllable low pressure zone connected to a drain located between the two check valves located upstream and downstream of the device. The two check valves delimit three different pressure zones each with a pressure plug. FLOW FAULT…
-
07C
BACKFLOW PREVENTERS 3501 Controllable BA-type low pressure backflow preventer TECHNICAL SPECIFICATIONS: • ISO 228 threads • Body material: Brass CW 602N (1/2’ – 3/4’’); Bronze (> 1’’) • BA-type according to EN 1717 • Against the risk of contamination with water up to category 4 Code Type 350 0296…
-
“TIEMME BOX” FLUSH-MOUNTED MODULES FOR ONE RADIANT AREA ADJUSTMENT 08A TIEMME BOX 148
-
The TIEMME BOX modules ensure the connection and
regulation of the temperature of a single zone of the heating system on floor or wall without the aid of mixing valves or pumping stations, even in centralized systems. Being able to adjust and regulate with precision the single user has as final result not only in the comfort of the rooms, but also…
-
FOR HEATING ADJUSTMENT BASED ON ROOM TEMPERATURE
PRODUCT RANGE OPERATION The room temperature is adjusted by a thermostatic valve with continuous proportional regulation (art. 9553) included in the box. As the room temperature increases or decreases, the shut-off valve inside the TIEMME BOX opens or closes respectively. Once the desired room…
-
TO LIMIT THE RETURN TEMPERATURE OF THE CIRCUIT
PRODUCT RANGE OPERATION The room temperature is adjusted by limiting the temperature of the heating system return fluid using a special proportional thermostatic valve (RTL) in contact with the fluid (thermal conduction). Once the desired temperature has been set, the fluid flow will be closed every…
-
FOR HEATING ADJUSTMENT BASED ON ROOM TEMPERATURE AND LIMITING THE
CIRCUIT RETURN TEMPERATURE PRODUCT RANGE OPERATION The room temperature is adjusted by a thermostatic valve with continuous proportional regulation (art. 9553) included in the box. As the room temperature increases or decreases, the shut-off valve inside the TIEMME BOX opens or closes respectively.…
-
COMPONENTS FOR SOLAR HEATING SYSTEMS 09A Hydraulic power units for solar heating systems 154 09B Accessories for hydraulic power units 155 09C Components for solar heating systems 157 09D Quick-coupling fittings “COBRASUN” 164 09E Quick-coupling fittings “EASYSOLAR” 167 09F Fittings for copper pipe…
-
09A
HYDRAULIC POWER UNITS FOR SOLAR HEATING SYSTEMS 4745 4745R Double hydraulic power unit for solar heating systems with insulation included. Version with deaerator, ball valve with integrated thermometer, 6 bar safety unit and mechanical flowmeter TECHNICAL SPECIFICATIONS • Size: DN 25-1” •…
-
09B
ACCESSORIES FOR HYDRAULIC POWER UNITS 4736SONDA 4735E PT1000 temperature probe, two-metre silicone cable, steel probe 6x25mm Programmable electronic temperature controller for solar systems, large LCD display Code Input Output Sensor 470 0516 0517 0518 6 3 Price € Unit/Box Code Size 2 1/4 470 0027…
-
09B
ACCESSORIES FOR HYDRAULIC POWER UNITS 6531G 3890PG4 Balancing valve with flow meter Price € Unit/Box GRUNDFOS Solar UPM3 PM 15/75 high efficiency pump with PWM control and 130 mm interaxle HIGH EFFICIENCY PUMP Code Type 651 0002 1” - 4÷15 l/min 1/25 Code Type 651 0003 1” - 8÷30 l/min 1/25 470 0407…
-
2330SUN
2991SUN Ball valve female/female connections with orange plastic flat handle Maximum temperature 180°C Code Type 472 0012 472 0008 472 0015 Price € Ball cock fill/drain for high temperatures. 1/2” fitting with pre-seal Unit/Box Code Type 1/2” 25/100 472 0019 1/2” 3/4” 15/60 1” 10/40 Price € Unit/Box…
-
1917SUN
1927SUN Safety valve for solar heating systems. Max temperature max 160°C. Nominal pressure 10 bar Female connecting thread ISO7 Code Type Calibration Price € 472 0089 1/2” x 1/2” 2,5 bar 1/40 472 0080 1/2” x 3/4” 2,5 bar 1/40 472 0011 1/2” 3/4” 3 bar 1/40 472 0006 1/2” 3/4” 6 bar 1/40 3177XSUN…
-
4737SUN
4738KIT Chrome-plated thermostatic mixing valve F for solar heating systems TECHNICAL SPECIFICATIONS • Compliance with: UNI EN 1111 • Temperature range: 30÷55°C • Max operating pressure: 10 bar • Max inlet temperature: 100°C • Body material: brass CW617N • Handle material: PA • Flow rate at 3 bar…
-
DIVERTER/THERMOSTATIC MIXING VALVE CONNECTION KIT
SOLAR STORE-BOILER Diverter/thermostatic mixing valve connection kit for solar store-heater art. 475KIT is a strong option for integrating the domestic hot water production of a solar panel system with an instant water boiler or with a store. Allows better management of thermal energy contained in a…
-
DIVERTER/THERMOSTATIC MIXING VALVE CONNECTION KIT
SOLAR STORE-BOILER PRODUCT RANGE ACCESSORIES AND SPARE PARTS 475KITISOL 475KIT Insulation shell for 5-way solar kit with diverter and thermostatic mixing valve Diverter/thermostatic mixing valve connection kit for solar store-heater. MANUFACTURING SPECIFICATIONS • Body: Chrome plated brass CW617N •…
-
THERMOSTATIC DIVERTER VALVE
Thermostatic diverter valve for solar heating systems art. 3894VDSUN carries out the function of diverting the fluid in two possible directions - on the basis of the inlet water temperature and the set temperature value. The function of the diverter is incurred by the thermostatic element which in…
-
2134SUN
4731ANTIG 3-way motorized ball diverter valve - 3 union fitting Code Type Supply 472 0009 3/4” 472 0013 1” Price € Anti-freeze for mixing for solar systems Unit/Box Code Litres 230 VAC 1/4 470 0026 10 230 Vac 1/4 Price € Unit/Box 1/1 4730V Preset 3 bar expansion vessel Code Capacity Price € Unit/Box…
-
09 D
-
09 D
QUICK-COUPLING “COBRASUN” FITTINGS FOR STAINLESS STEEL CORRUGATED PIPE 3004X 3015 Elbow fitting male Olive PATENTED PATENTED Code Type 071 0129 DN16 x 3/4” M Price € Unit/Box Code Type 4/40 071 0104 DN12 50/1000 071 0105 DN16 50/1000 071 0106 DN20 50/1000 071 0107 DN25 50/1000 071 0155 DN32 50/1000…
-
09D
QUICK-COUPLING “COBRASUN” FITTINGS FOR STAINLESS STEEL CORRUGATED PIPE INSTALLATION GUIDE 1 Set the edge in the groove perpendicular to the pipe. Cut should be neat, without rough edges 2 5 Manually loosen nut approx. 1/2 turn, if not already loosened 6 «CLACK» «CLACK«»CLACK» «CLACK» Push the pipe…
-
09 E
-
09E
QUICK-COUPLING FITTINGS “EASYSOLAR” 3203KB Double elbow fitting stainless steel/copper Code Type 071 0032 DN16 x 22 (Cu) Price € COMPATIBILITY TABLE CORRUGATED STAINLESS STEEL PIPE A Unit/Box 5/75 RECOMMENDED PIPE SIZE DN* A 16 21.4 ± 0.2 20 26.4 ± 0.2 25 31.7 ± 0.25 *For different diameters please…
-
FITTINGS FOR COPPER PIPE AND STAINLESS STEEL CORRUGATED PIPE
CONNECTION KIT FOR CORRUGATED STAINLESS STEEL PIPE ON FITTINGS WITH MALE THREAD FLAT SEAT DESCRIPTION Connection kits art. 1552SET and 8930SET mean quick and easy connection of corrugated steel pipe on fittings with male thread flat seat. See range of compatible fittings (tagged FLAT SEAT) listed in…
-
FITTINGS FOR COPPER PIPE AND STAINLESS STEEL CORRUGATED PIPE
1100FD 1552FD Straight fitting, nut and olive for copper pipe, male connecting thread with flat seat for corrugated steel pipe and flat washer FLAT SEAT Nipple male thread with flat seat for corrugated steel pipe and flat washer FLAT SEAT Code Type 471 0023 Price € Unit/Box Code Type 15 x 1/2”…
-
1581FD
1005 1105 Reducer male/female with flat seat Bend fitting, nut and olive for copper pipe, female thread Code Type 100 0016 15 x 1/2" 10/100 100 0067 15 x 3/4" 5/75 25/100 FLAT SEAT Price € Unit/Box 471 0050 Type A B 1/2" x 3/8" 110 0138 16 x 1/2" 10/100 471 0022 3/4" x 1/2" 10/100 110 0018 18 x 3/4"…
-
1564FD
-
1147 Male end cap Code Type 150 0273 150 0040 Price € Bushing adapter Unit/Box Code Type 3/8” 25/200 113 0062 15 x 10 25/900 1/2” 25/300 113 0026 15 x 12 25/900 150 0019 3/4” 10/150 113 0079 18 x 12 25/750 150 0077 1” 10/100 110 0243 18 x 14 25/750 150 0222 1” 1/4 5/100 113 0018 18 x 15 25/750 150…
-
1039S
1113KB Tee union with probe holder well (probe Ø6 mm), nut and olive for copper pipe Type Probe length 471 0064 15 x 15 471 0034 18 x 18 471 0073 18 x 18 164 mm 2/10 471 0024 22 x 22 123 mm 2/10 Code Cross fitting with nut and olive for copper pipe, COBRASUN quick-coupling with probe holder well…
-
1119FD
3353G Cross fitting with male flat seat connecting threads for corrugated steel pipe and flat washer FLAT SEAT Code Type 471 0045 3/4” x 3/4" Price € Unit/Box Air vent valve with copper gasket Code Type 472 0003 1/2” Price € Unit/Box 10/500 5/50 1900KITSUN Automatic air vent valve with ball valve…
-
09G
CORRUGATED STAINLESS STEEL PIPE AND ACCESSORIES 0700X 0705COL Pair of insulated corrugated stainless pipes with electrical cable for connecting to electronically-controlled temperature probe Code Type 070 0002 070 0001 Price €/m 4 oval collar set for wall mounting pair of insulated corrugated steel…
-
DIRECT METERING UTILITY MODULES 10A Direct metering - introduction 178 10B SHORTY metering system SHORTY metering system 180 SHORTY DYNAMIC metering system 186 10C BASIC metering system BASIC metering system 192 BASIC HT metering system 195 10D MULTI-MODUL metering system 199 10E VARIO metering…
-
10A
DIRECT METERING - INTRODUCTION In recent years, the ever greater focus on energy saving and the reduction of polluting emissions has steered the building industry toward the installation of centralized systems and heat metering systems able to determine the calories/frigories used for ambient…
-
10A
THE TIEMME DIRECT METERING SYSTEM Tiemme metering modules are right at home within buildings with centralized systems and in systems with district heating, allowing the completely autonomous management by each individual unit as prescribed by the regulations in force. TIEMME has pre-assembled…
-
INTRODUCTION
Metering module for heating/cooling and domestic water circuits, featuring reduced dimensions. Ideal system solution where space is limited and for flow rates up to 2.5 m3/h. Available in different versions and configurations to meet various installation needs: • Available with 3 domestic water…
-
INSTALLATION COMPONENTS
6502C01 6502C01-3C Pre-installation metal housing for “SHORTY STATIC” system. Setup stubs included. Pre-installation metal housing for “STATIC SHORTY AND THREE DOMESTIC WATER LINES” system. Pre-set stubs included. DESCRIPTION • Galvanized steel housing complete with painted frame and cover white RAL…
-
INSTALLATION COMPONENTS
6502C01DUO 6502C01DUO-3C Pre-installation metal housing for “SHORTY DUO STATIC” system. Pre-set stubs included. DESCRIPTION • Galvanized steel housing complete with painted frame and cover white RAL 9010 - Dimensions (WxHxD) 500 x 800 x 120 ÷ 170 mm • Shut-off ball valves for heating/cooling circuit…
-
INSTALLATION COMPONENTS
6502KP 6502G03 ”SHORTY” System wall mount pre-installation kit. Pre-set stubs included. “SHORTY” compact heat meter metering module, 3-way motorized zone valve for heating/cooling systems. Wireless 00569.79 TURBINE DESCRIPTION • Shut-off ball valves for heating/cooling circuit with 3/4” M and 1” F…
-
ACCESSORIES
6561C 6561CR 6561HR Single jet meter for hot or cold water with local or remote M-Bus reading. Single jet meter for hot or cold water with local or wireless remote reading 00569.79 00569.79 Wireless OPTIONAL TURBINE TECHNICAL SPECIFICATIONS • Brass casing with direct reading on 8 numbered rollers: 5…
-
ACCESSORIES
6502K 6502I Fixing kit components for "SHORTY" and "SHORTY DYNAMIC" metering modules DESCRIPTION • Shut-off ball valves for heating/cooling circuit with 3/4" M and 1" F fittings with idle nut • Shut-off ball valves for domestic hot/cold water line with 3/4" M and 3/4" F fittings with idle nut (with…
-
INTRODUCTION
Metering module for heating/cooling and domestic water circuits, featuring reduced proportions. Ideal system solution where space is limited and for flow rates up to 2.5 m3/h. Fitted with a dynamic balancing PICV (Pressure Independent Control Valves), the system-side flow rate can be adjusted from a…
-
INSTALLATION COMPONENTS
6502C01DYN 6502C01DYN-3C Pre-installation metal housing for “SHORTY DYNAMIC” system. Setup stubs included. Pre-installation metal housing for “SHORTY DYNAMIC AND THREE DOMESTIC WATER LINES” system. Setup stubs included. DESCRIPTION • Galvanized steel housing complete with painted frame and cover in…
-
INSTALLATION COMPONENTS
6502C01DUODYN 6502C01DUODYN-3C DESCRIPTION • Galvanized steel housing complete with painted frame and cover in white RAL 9010 - Dimensions (WxHxD) 500 x 800 x 120 ÷ 170 mm • Shut-off ball valves for heating/cooling circuit with 3/4” M and 1” F fittings with idle nut • Shut-off ball valves for…
-
INSTALLATION COMPONENTS
6502KPDYN 6502G03DYN ”SHORTY” system wall mounting pre-installation kit. Setup stubs included. “SHORTY DYNAMIC” metering module consisting of compact calorie counter, 3-way motorized zone valve for heating/cooling systems, PICV dynamic balancing valve. Wireless 00569.79 TURBINE DESCRIPTION •…
-
ACCESSORIES
6561C 6561CR 6561HR Single jet meter for hot or cold water with local or remote M-Bus reading. Single jet meter for hot or cold water with local or wireless remote reading 00569.79 00569.79 Wireless OPTIONAL TURBINE TECHNICAL SPECIFICATIONS • Brass casing with direct reading on 8 numbered rollers: 5…
-
ACCESSORIES
6502K 6502IDYN Fixing kit components for "SHORTY" and "SHORTY DYNAMIC" metering modules DESCRIPTION • Shut-off ball valves for heating/cooling circuit with 3/4" M and 1" F fittings with idle nut • Shut-off ball valves for domestic hot/cold water line with 3/4" M and 3/4" F fittings with idle nut…
-
INTRODUCTION
Metering modules for heating/cooling or domestic water circuits, featuring extremely compact dimensions. Equipped with wall brackets. They are the ideal solution for systems where space is limited and for capacities up to 2.5 m3/h for heating/cooling and up to 4 m3/h for domestic water. HEATING/…
-
INSTALLATION COMPONENTS
-
INSTALLATION COMPONENTS
ACCESSORIES 6510P01 6561E Single bracket domestic water module Pulse emitter cable. 1/10 pulse/ litre. TECHNICAL SPECIFICATIONS • Cable length: 1 m Code Type Price € 651 0085 For 6561C Unit/Box 1/10 00569.79 Wireless OPTIONAL TURBINE 6575C DESCRIPTION • Shut-off ball valves with 3/4” M and 3/4" F…
-
INTRODUCTION
Metering module for heating/cooling circuits, mounted on brackets for wall mounting. It is the ideal solution for metering the consumption of large-scale apartments. Suitable for flow rates up to 3.5 m3/h (for DN25 measurement) and 6 m3/h (for DN32 measurement). Available with 2 or 3-way zone valve…
-
INSTALLATION COMPONENTS
6500G02DN25 6500G03DN25 Pre-installation module for “BASIC DN25” system with 2-way zone valve, for housing art. 1940. Setup stubs included. Pre-installation module for “BASIC DN25” system with 3-way zone valve, for housing art. 1940. Setup stubs included. DESCRIPTION • Shut-off ball valves with 1” F…
-
INSTALLATION COMPONENTS
6500G02DN32 6500G03DN32 Pre-installation module for “BASIC DN32” system with 2-way zone valve, for housing art. 1940. Setup stubs included. Pre-installation module for “BASIC DN32” system with 3-way zone valve, for housing art. 1940. Setup stubs included. DESCRIPTION • Shut-off ball valves with…
-
ACCESSORIES
6565SB 6562T PT500 temperature probe pair (EN 60751) for wells art. 3670PS (“wet” mount). Multiple-jet, super dry, magnetic transmission meter, pulse outlet 1/10 imp/l. 00569.79 TURBINE OPTIONAL Wireless OPTIONAL TECHNICAL SPECIFICATIONS • Brass casing • Protective metal cap • Rotatable totalizer…
-
INTRODUCTION
Multi-utility metering module for heating/cooling or domestic water circuits. Suitable for flow rates up to 2.5 m3/h. The module can be installed directly within the shaft or in a metal housing (optional) that accommodates up to 5 measurement units. The DN40 mounting on which the various modules are…
-
INSTALLATION COMPONENTS
6509MN 6509RT Flow rate metering module with 2-way motorized zone valve for “MULTI-MODUL” heating/cooling system DESCRIPTION • Manifold 1”1/2 with 3/4” F shunt connection • Shut-off ball valve • "Y" fitting probe holder with M10x1 socket for supply temperature reading • Motorized 2-way zone valve…
-
INSTALLATION COMPONENTS
6509SNC 6509SNF Metering module for domestic hot water with pre-installation stub for “MULTI-MODUL” system DESCRIPTION • Manifold 1”1/2 with 3/4” F shunt connection • Shut-off ball valves (with or without built-in non-return valve) • “Pre-installation" stub for testing and/or flushing system and…
-
ACCESSORIES
6509K 6509IMN Pair of clamps. Price € Thermoformed thermal insulation for metering module 6509MN. Code Type Unit/Box 651 0351 L = 20 mm 1/10 651 0352 L = 65 mm 1/10 TECHNICAL SPECIFICATIONS • Insulating shell material: PEX closed cell foam Code Type 650 0411 by art. 1882 Type 195 0041 1”1/2 Price €…
-
ACCESSORIES
2121CP 6560CUW 6568C ISO 228 male/female ball valve with aluminium handle for manifolds and Flat washer Code Type Price € Compact ultrasonic calorie/ frigory meter for local reading, M-Bus remote reading and wireless reading. 00569.79 Unit/Box Wireless ULTRASOUNDS 212 0122 red handle 1"1/2 3/12 212…
-
ACCESSORIES
6561C 6561CR 6561HR Single-jet meter for hot or cold water with local or remote M-Bus reading Single-jet meter for hot or cold water with local or wireless remote reading 00569.79 00569.79 Wireless OPTIONAL TURBINE TECHNICAL SPECIFICATIONS • Brass casing with direct reading on 8 numbered rollers: 5…
-
INTRODUCTION
Metering module for heating/cooling and domestic water circuits. It is the ideal solution for metering the consumption of large-scale apartments. Suitable for flow rates up to 3.5 m3/h (for DN25 measurement) and 6 m3/h (for DN32 measurement). Available with 2- or 3-way zone valve to meet different…
-
INSTALLATION COMPONENTS
6500C0125V2 6500C0125V3 Pre-installation metal housing for “VARIO DN25” system, with 2-way zone valve. Setup stubs included. Pre-installation metal housing for “VARIO DN25” system, with 3-way zone valve. Setup stubs included. DESCRIPTION • Galvanized steel housing complete with painted frame and…
-
INSTALLATION COMPONENTS
6500C0132V2 6500C0132V3 DESCRIPTION • Galvanized steel housing with painted frame and cover in white RAL 9010 - Dimensions (WxHxD) 750 x 750 x 140 ÷ 190 mm • Shut-off ball valves for heating/cooling circuit with 1”1/4 F fittings • Motorized 2-way zone valve (230 VAC power supply) • “Y” supply/return…
-
ACCESSORIES
6562T 6564C Multiple-jet, super dry, magnetic transmission meter, pulse outlet 1/10 imp/l. Separate electronic unit for combined heat energy meters. 00569.79 TURBINE Wireless OPTIONAL OPTIONAL TECHNICAL SPECIFICATIONS • Brass casing • Protective metal cap • Rotatable totalizer for easy reading •…
-
ACCESSORIES
6561C 6561CR 6561HR Single-jet meter for hot or cold water with local or remote M-Bus reading. Single-jet meter for hot or cold water with local or wireless remote reading 00569.79 00569.79 Wireless OPTIONAL TURBINE TECHNICAL SPECIFICATIONS • Brass casing with direct reading on 8 numbered rollers: 5…
-
INTRODUCTION
Metering module for heating/cooling and domestic water circuits with system-side connection fittings at the bottom of the housing. It is the ideal solution for horizontal distribution systems. Available with 2- or 3- way zone valve. The presence of a bypass differential valve makes it an extremely…
-
INSTALLATION COMPONENTS
6501C0120 6501G03 Pre-installation metal casing for “FLOOR DN20” system. Setup stubs included DESCRIPTION • Galvanized steel housing with painted frame and cover in white RAL 9010 - Dimensions (WxHxD) 850 x 670 x 120 ÷ 170 mm • Shut-off ball valves for heating/cooling circuit with 3/4” M and 1” F…
-
INSTALLATION COMPONENTS
6501C0120 + 6501G02 6501C0120 + 6501G03 212 DIMENSIONAL DIAGRAM FUNCTIONAL DIAGRAM Abbrev. Description CHS Central heating supply CHR Central heating return CS Consumer supply CR Consumer return DHW Domestic hot water DCW Domestic cold water For pricelist scan the QR code
-
INTRODUCTION
Metering module for heating/cooling and domestic water circuits with system-side connection fittings at the bottom of the housing. The ideal solution when metering consumption across large-footprint apartments with horizontal distribution. Suitable for flow rates up to 3.5 m3/h (DN25) and 6 m3/h…
-
INSTALLATION COMPONENTS
6501C0125V2 6501C0125V3 DESCRIPTION • Galvanized steel housing with painted frame and cover in white RAL 9010 - Dimensions (WxHxD) 1000 x 670 x 120 ÷ 170 mm • Shut-off ball valves for heating/cooling circuit and bend fittings with 1” F connections • Motorized 2-way zone valve (230 VAC power supply)…
-
INSTALLATION COMPONENTS
6501C0132V2 6501C0132V3 DESCRIPTION • Galvanized steel housing with painted frame and cover in white RAL 9010 - Dimensions (WxHxD) 1200 x 670 x 120 ÷ 170 mm • Shut-off ball valves for heating/cooling circuit and bend fittings with 1”1/4 F connections • Motorized 2-way zone valve (230 VAC power…
-
ACCESSORIES
6562T 6564C Multiple-jet, super dry, magnetic transmission meter, pulse output 1/10 imp/l. Separate electronic unit for combined heat energy meters. 00569.79 TURBINE Wireless OPTIONAL OPTIONAL TECHNICAL SPECIFICATIONS • Brass casing • Protective metal cap • Rotatable totalizer for ease of reading •…
-
ACCESSORIES
6561C 6561CR 6561HR Single-jet meter for hot or cold water with local or remote M-Bus reading. Single-jet meter for hot or cold water with local or wireless remote reading 00569.79 00569.79 Wireless OPTIONAL TURBINE TECHNICAL SPECIFICATIONS • Brass casing with direct reading on 8 numbered rollers: 5…
-
10G
HEAT METERING SYSTEM INTRODUCTION Metering module for heating-only circuits with instant DHW production via steel exchanger. The instant production of domestic hot water avoids the energy losses along the distribution lines and guarantees DHW at the correct temperature everywhere throughout the…
-
10G
HEAT METERING SYSTEM INSTALLATION COMPONENTS 6503C01 6503G03P Pre-installation metal housing for “HEAT” system. Setup stubs included. DESCRIPTION • Galvanized steel housing with painted frame and cover in white RAL 9010 - Dimensions (WxHxD) 850 x 670 x 120 ÷ 170 mm • Shut-off ball valves for…
-
INTRODUCTION
Metering module for heating circuits with instant DHW production via steel exchanger and, if equipped, fitting for recirculation. With dynamic balancing valve, pressostatic valve for domestic water priority, zone valve and insulation. It is one of the most widely used systems for metering energy…
-
INSTALLATION COMPONENTS
HEAT-EVO1 HEAT-EVO2 Metering module with outlet for low temperature heating (with mixing) for radiant systems, pump for heating system and pump for DHW recirculation Metering module with outlet for low temperature heating (with mixing) for radiant systems and pump for heating system DESCRIPTION •…
-
INSTALLATION COMPONENTS
HEAT-EVO3 HEAT-EVO4 Metering module with outlet for high temperature heating (for radiators) and DHW recirculation pump Metering module with outlet for high temperature heating (for radiators) DESCRIPTION • Plate heat exchanger 53 kW • Priority valve for domestic water circuit • Domestic water…
-
INSTALLATION COMPONENTS
HEAT-EVO1DYN Metering module with outlet for low temperature heating (with mixing) for radiant systems, pump for heating system and pump for DHW recirculation DESCRIZIONE • Plate heat exchanger 53 kW • Priority valve for domestic water circuit • Domestic water recirculation pump • Dynamic balancing…
-
ACCESSORIES
6560CW 6560C 6560CUW 6568C Compact single-jet calorie/ frigory meter for local reading, M-Bus remote reading and wireless reading. Compact ultrasonic calorie/ frigory meter for local reading, M-Bus remote reading and wireless reading. 00569.79 00569.79 Wireless TURBINE TECHNICAL SPECIFICATIONS •…
-
INTRODUCTION
Metering module for heating/cooling and domestic water circuits with hydraulic separator suitable for thermal systems where flow rates and operating temperatures are significantly different. Set-up for fixed-point or climatic adjustment. Equipped with a two or three module hydraulic separator able…
-
INSTALLATION COMPONENTS
6506C02 6506C03 Metering module with three-module separator and low and high temperature distribution. Complete with booster pump for low temperature secondary branch-off and booster pump for high temperature secondary branch-off Metering module with two-module separator and low and high temperature…
-
INSTALLATION COMPONENTS
6506C04 6506C05 Metering module with twomodule separator and low temperature distribution. With thermostatic mixing valve and secondary booster pump Metering module with two-module separator and low or high temperature distribution. Without secondary mixing. With secondary circuit pump DESCRIPTION •…
-
ACCESSORIES
6560CW 6560C 6560CUW 6568C Compact single-jet calorie/ frigory meter for local reading, M-Bus remote reading and wireless reading. Compact ultrasonic calorie/ frigory meter for local reading, M-Bus remote reading and wireless reading. 00569.79 00569.79 Wireless TURBINE TECHNICAL SPECIFICATIONS •…
-
ACCESSORIES
6561C 6561CR 6561HR Single-jet meter for hot or cold water with local or remote M-Bus reading Single-jet meter for hot or cold water with local or wireless remote reading 00569.79 00569.79 Wireless OPTIONAL TURBINE TECHNICAL SPECIFICATIONS • Brass casing with direct reading on 8 numbered rollers: 5…
-
ACCESSORIES
9561TT 6506I2M Kit for adjustable fixed point adjustment 20÷50°C. Code Type 040 0179 Fixed point Price € Unit/Box 1/1 Thermoformed thermal insulation for "TECHNO SEP” metering module with 2-module hydraulic separator DESCRIPTION • Insulating shell material: PEX closed cell foam Code Type 650 0414…
-
DIRECT METERING METERS 11A Meters - introduction 232 11B Thermal energy meters 233 11C Domestic water meters 233
-
11 A
METERS - INTRODUCTION Meters are instruments used to measure thermal energy and domestic water usage. M-Bus-enabled meters allow the transfer of tracking data to a data concentrator. The particularly wide range permits their application both in domestic-type systems and in industrial-type systems.…
-
COMPACT SINGLE-JET
MECHANICAL METER COMPACT ULTRSONIC METER 6560CW 6560C 6560CUW 6568C Compact single-jet calorie/ frigory meter for local reading, M-Bus remote reading and wireless reading. Compact ultrasonic calorie/ frigory meter for local reading, M-Bus remote reading and wireless reading. 00569.79 00569.79…
-
HIGH FLOW RATE METERS
- SEPARATE ELECTRONICS WOLTMANN FLANGED SERIES METER SEPARATE ELECTRONICS 6562T 6563CC130 Multiple-jet, super dry, magnetic transmission meter, pulse outlet 1/10 imp/l. Woltmann flanged series thermal energy meter. 00569.79 TURBINE OPTIONAL Wireless OPTIONAL TECHNICAL SPECIFICATIONS • Brass casing •…
-
ULTRASONIC HIGH FLOW RATE METERS - SEPARATE ELECTRONICS
6569CW Ultrasonic thermal energy meter with flanged fittings PN25. Suitable for industrial installation 00569.79 ULTRASOUNDS OPTIONAL Wireless OPTIONAL TECHNICAL SPECIFICATIONS • Maximum operating temperature 130 °C • Nominal pressure: PN25 • With electronics - cable length 2m • Battery powered…
-
ACCESSORIES
6565SB 6564C Temperature probe pair PT500 (EN 60751) for wells art. 3670PS (“wet” mounting). Separate electronic unit for combined heat energy meters. Wireless TECHNICAL SPECIFICATIONS • Calorie and frigory measurement • 3V replaceable lithium battery, 10 year service life • Communication…
-
LOCAL READING/M-BUS
VOLUMETRIC METER LOCAL READING/M-BUS VOLUMETRIC METER 6561C 6561CR 6561HR Single-jet meter for hot or cold water with local or remote M-Bus reading Single-jet meter for hot or cold water with local or wireless remote reading 00569.79 00569.79 Wireless OPTIONAL TURBINE TECHNICAL SPECIFICATIONS •…
-
HIGH FLOW RATE DOMESTIC COLD
WATER VOLUMETRIC METER HIGH FLOW RATE DOMESTIC COLD WATER VOLUMETRIC METER 6561D 6562D Local reading multiple-jet meter for domestic cold water for high flow rate equipped with pulse emitter 1/10 pul/l for M-Bus remote reading Local reading multiple-jet meter for domestic cold water for high flow…
-
WOLTMANN FLANGED SERIES DOMESTIC COLD WATER METER
6563CF Woltmann axial volumetric meter for domestic cold water up to 50° C flanged. ACCESSORIES AND SPARE PARTS 6583S Reed sensor for Woltmann meters. 1/100 pulse/liter. 00569.79 TURBINA OPTIONAL Wireless OPTIONAL TECHNICAL SPECIFICATIONS • Cast iron casing • Clockwork with glass disc and copper…
-
ACCESSORIES
6561E 6561RS Pulse emitter cable. 1/10 pulse/ liter. TECHNICAL SPECIFICATIONS • Cable length: 1 m Code Type 651 0085 For 6561C Price € Unit/Box Pulse emitter REED SWITCH type. 1/10 pulse/liter. Code Type 651 0531 For 6561D Price € Unit/Box 1/10 1/10 6583S Reed sensor for Woltmann meters. 1/100…
-
ACCESSORIES
6575C 1522 Pulse adapter on M-Bus for meter pairs. Code Type 651 0074 - Price € Unit/Box 1/10 6570C Electrical connections housing (only box to facilitate connections). Code Type Price € Union kit The kit includes: 2 tails, 2 nuts and 2 gaskets Code Ø Meter Ø Fitting Price € Unit/Box 150 0035 3/4” F…
-
INDIRECT METERING HEAT COST ALLOCATORS 12A Hydrothermal consumption metering Indirect metering - introduction 244 The Tiemme indirect metering system 245 12B Heat cost allocators 246 12C Thermostatically-controlled valve kit with pre-setting 247 12D Thermostatically-controlled valve kit 249 12E 251…
-
12A
INDIRECT METERING - INTRODUCTION In recent years, the ever greater focus on energy saving and the reduction of polluting emissions has steered the building industry toward the installation of centralized systems and heat metering systems able to determine the calories/frigories used for ambient…
-
12A
THE TIEMME INDIRECT METERING SYSTEM A centralized heating system, on vertical risers, allows every individual dwelling to regulate their temperature autonomous. To quantify usage and divide the expenditure in proportion to how much each actually uses (voluntary consumption), TIEMME proposes the…
-
12B
HEAT COST ALLOCATOR Heat cost allocators indirectly measure the usage of every heating body (radiators), via temperature tracking of heating body on which they are installed and the ambient temperature. Through the proportionality parameters with thermal emission in the room, once the power of the…
-
12C
THERMOSTATICALLY-CONTROLLED VALVE WITH PRE-SETTING KIT ADVANTAGES / STRENGTHS Adjustable flow rate The thermostatic valves series 331 and 332 are equipped with a fixed orifice water flow rate adjustment element which, via a sixposition selector, allows choosing the correct flow rate to get all the…
-
12C
THERMOSTATICALLY-CONTROLLED VALVE KIT WITH PRE-SETTING Thermostatically-controlled valve with pre-setting, thermostatic head and “EXCEL” lockshield valve (version with o-ring) 331HKIT 332HKIT Three-piece kit comprising: angled valve THERMOSTATICALLYCONTROLLED WITH PRESETTING, thermostatic head…
-
12D
THERMOSTATICALLY-CONTROLLED VALVE KIT Thermostatically-controlled valve, thermostatic head and “EXCEL” lockshield valve (version with o-ring) 3308KIT04R 3303KIT04R Three-piece kit comprising: THERMOSTATICALLYCONTROLLED angled valve, thermostatic head, EXCEL angled lockshield valve with fitting for…
-
12D
THERMOSTATICALLY-CONTROLLED VALVE KIT Thermostatically-controlled valve, thermostatic head and lockshield valve 3308KIT03 3303KIT03 Three-piece kit comprising: THERMOSTATICALLYCONTROLLED angled valve, thermostatic head, angled lockshield valve with fitting for iron pipe Code Type Price € 330 0133 G…
-
12 E
THERMOSTATIC CONTROLS 9553- 9553C Thermostatic controls art. 9553 - 9553C meet the requirements of the Italian Ministry of Economy and Finance Decree dated 19 February 2007 and decree law 6 Dicembre 2011 and subsequent. ADVANTAGES / STRENGTHS Quality materials The Tiemme thermostatic control is been…
-
12E
THERMOSTATIC CONTROLS 9553 9553AM2 Thermostatic head with built-in liquid sensor temperature range 6-28°C Code Type 955 0025 M30 x 1.5 Price € Vandal proof and antitampering kit for thermostatic head 9553/9553C Unit/Box Code Type 1/30 955 0033 - 9553C Type 955 0026 M30 x 1.5 Price € Unit/Box Code…
-
New section TEMPERATURE CONTROLS 13A Thermostats and chronothermostats 254 13B Wireless temperature controls 257 13C Wi-Fi temperature controls 260
-
9581 Electro-mechanical room thermostat TECHNICAL CHARACTERISTICS • Output: normally open contact 16(2,5) A/250 Vac • Temperature range: 5-30°C • Differential: ± 0,5°C Code Type 957 0002 electro-mechanical Price € Unit/Box 1/40 9573 Touchscreen electronic room thermostat TECHNICAL CHARACTERISTICS •…
-
Electrothermal actuator Code Type Price € Unit/Box 450 0026 24V 1/20 450 0012 230V 1/20 450 0045 24V 1/20 450 0006 230V 1/20 Auxiliary microswitch version 9568 Electrothermal actuator (for thermostatic valves and polyamid manifold art. 3872POL - 3871PMON) Code Type Price € Unit/Box 450 0543 24V 1/20…
-
4625D
10 channel control unit to connect the room thermostat (wire connection) and the relevant electrothermal actuators, output relay for pump 230Vac 5(2)A Code Type 957 0005 230V Price € Unit/Box 1/6 With output relay for pump 4625D HOW TO USE Room thermostat 230Vac N F Zone Sum./ Win. 9575 1 Nr. 5 2…
-
Wireless temperature controls allow ambient climate adjustment without investing in masonry work
Thanks to wireless technology the various elements communicate and control the opening or closing of devices (boiler/heat pump/ radiator valves) according to the user’s specified profile comfort profile, the whole thing running on battery power. 4601 Electronic touchscreen wireless room thermostat…
-
9556W
OPERATION ART. 4607 Load activation (air-conditioning, boiler etc) occurs via the remote receiver which is remote controlled by the thermostat/chronothermostat (ordered separately) across a radio frequency signal. This makes it possible to situate the the thermostat anywhere within your home without…
-
9556W-4601-9580W
INSTALLATION EXAMPLE 9556 W 4601 4601 9580 W 9556 W 9556 W 9556 W 4601-4612-9567 INSTALLATION EXAMPLE Room thermostat Zone Zone Zone Zone Zone Zone 4601 Pump Radio receiver 4612 F N Zone Zone Zone Zone Zone Zone 9567 Electrothermal actuator 259
-
13C
WI-FI TEMPERATURE CONTROLS TIEMME NEXT Digital electronic chronothermostats with Wi-Fi communication can remotely manage climate control with an App. Integrated Wi-Fi module allows to remotely control the chronothermostat with your smartphone. You only need to connect the device to your router and…
-
DATA COLLECTION AND READING SYSTEMS 14A Data collection and reading systems 262 14B M-Bus dataloggers 263 14C Radio dataloggers 267
-
14 A
DATA COLLECTION AND READING SYSTEMS - INTRODUCTION The ultimate goal of DIRECT and INDIRECT metering is the determination of consumption data for each individual housing unit, so as to proceed with the correct invoicing of expenditure. Tiemme proposes different devices and systems for collecting and…
-
INTRODUCTION
M-Bus dataloggers are electronic data collection devices; They acquire data relating to thermal energy and domestic water consumption from all the devices that make up the system (thermal energy meters and volumetric meters) connected to the M-Bus network. The consumption data can be read either…
-
“LOCAL M-BUS” SYSTEM
In the “Local M-Bus” system, the receiver is permanently installed in the building where it logs consumption data. The system consists of a centralized datalogger and an M-Bus network to which all the accounting devices (thermal energy meters and domestic meters) and the datalogger itself are…
-
“REMOTE M-BUS” SYSTEM
In the “remote M-Bus” system, the receiver is permanently installed in the building where it logs consumption data. The system consists of a centralized datalogger and an M-Bus network to which all the accounting devices (thermal energy meters and domestic meters) and the datalogger itself are…
-
WHAT IS THE M-BUS NETWORK
The M-Bus is a communication interface according to European standards EN 1434 and EN 13757, conceived in Germany. It has quickly become a standard for thermal energy, water, gas and electricity meter reading systems . The M-Bus network consists mainly in the laying of a double conductor cable with…
-
INTRODUCTION
Radio dataloggers are electronic data collection devices; They acquire thermal energy and domestic water consumption data from all the devices that make up the system (heat dividers, heat energy meters and volumetric meters) equipped with a 868 MHz radio communication interface compliant with…
-
“WALK-BY” SYSTEM
In the “walk-by” system the radio receiver is mobile, that is to say at the disposal of the reader who is to be near the meters requiring no access to the installation point of the latter. The walk-by reading mode allows the choice between two different devices, radio transceiver for mobile reading…
-
“FIXED RADIO SMART KIT” SYSTEM
In the “fixed Radio Smart Kit” system, the radio receiver is permanently installed in the building whose consumption data it collects. The system consists of a centralized logger and a self-setting network of allocators for collecting the information of the devices present. By connecting the…
-
“REMOTE RADIO SMART KIT” SYSTEM
In the “Remote Radio Smart Kit” system, the radio receiver is permanently installed in the building whose consumption data it collects. The system consists of a centralized datalogger and a self-setting network of allocators for collecting the information of the devices present. The data is sent to…
-
TIEMME, CERTIFIED QUALITY
FACSIMILE COPY The originals and the full text of the rules mentioned are available at the legal office of TIEMME RACCORERIE S.p.A. Via di San Giovanni - 25045 - Castegnato (Bs) PRODUCTS QUALITY TIEMME RACCORDERIE S.p.A. manufacturer of complete heating, sanitary and gas systems situated in…
-
WARRANTY CONDITIONS
The products manufactured by Tiemme Raccorderie S.p.A. (hereinafter referred to as “Company”) are guaranteed for 2 years from the date of shipment from its premises. This warranty is additional to and does not affect the buyer’s rights under the European Directive 99/44/CE and its national…
-
INTEGRATED COMPONENTS AND SYSTEMS FOR
PLUMBING PLANTS HYDRO COMPONENTS CENTRAL HEATING - METERING RADIANT SYSTEMS FAUCETS 274
-
Via Cavallera, n. 6/A - 25045 Castegnato (BS) - Italy Tel. +39 030 2142211 - Fax +39 030 2142206 info@�emme.com Customer Service Fax +39 030 2142254 customerservice@�emme.com www.�emme.com
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.