INDUSTRIAL FANS
GENERAL CATALOGUE pos
-
CONTROL
Fans designed to meet any kind of industrial application requirement. They are mostly installed in civil and industrial conditioning systems, drying plants, paint booths, boilers, furnaces, industrial burners, gas treatment, material transportation, cement plants, explosive atmospheres ATEX, Oil&Gas…
-
For many years the company invested in the development of processes and applications aimed at
manufacturing and supplying special industrial fans with extremely tight deadlines in terms of their design and production. The teamwork of our engineering department, in conjunction with universities and technological centres, and the close cooperation between the design departments of our external…
-
APPLICATIONS
Industrial Industrial boilers, drying barns, furnaces, industrial burners, gas treatment plants, transport of material, cement plants, explosive atmospheres ATEX and Oil&Gas are just some of the applications for fans of this type. Naval / Off-shore Our extract fans are known by most shipbuilders and…
-
The extract fans available on request are able to
comply with the different requirements of classification and certification organisations. Possibility of offering Design Approval Certificate from different naval entities on request. Mining / Public works The marine motors used are certified by most international naval classification entities.…
-
Standards
compliance for railway and rolling equipment Related standards: GOST 30630.0.0-99 Environment stability test methods for machines, instruments and other industrial products. GOST 28231-89 (IEC 68-2-47-82) Basic methods of testing for exposure to external factors. Part 2. Testing. Fastening of…
-
Vibrations
The table presented below shows the vibration requirements for mounted equipment in A-Class vehicle. Sodeca fans complies with GOST vibration requirements, which are the most restrictive. EN STANDARD Standard number Vibration RMS X Axis [m/s2] Vibration RMS Y Axis [m/s2] Vibration RMS Z Axis [m/s2]…
-
SMALL SERIES
MEDIUM PRESSURE 18 CMP Single inlet medium pressure centrifugal fans with sheet steel casing and impeller 28 CRL Centrifugal medium pressure single inlet fans with backward curved impeller 36 CBP Centrifugal fans of medium pressure and single inlet, equipped with backward curved impeller with…
-
MEDIUM
PRESSURE 76 CMRS Very robust single inlet, medium pressure centrifugal fans, equipped with a backward curved impeller Designed for clean or slightly dusty air 110 CAMA Extremely robust medium pressure and single inlet centrifugal fans with sheet steel casing and impeller Designed for dusty air 144…
-
ovens
308 FANS FOR BREAD AND PASTRY OVENS 310 SDECB/M Centrifugal fans especially designed for extracting hot air at a max. temperature of 80 °C and water vapour from extract hoods with a vertical air outlet Especially designed for bread and pastry ovens as well as industrial ovens 314 SDBP/M INOX…
-
Fans and their
applications Classification Application MEDIUM PRESSURE For dusty air · Paint booths · Dryers · Boilers · Preservation of cereals in years · Cooling of engines · Ventilation of warehouses · Ventilation in composting applications · Boiler systems · Drum filters · Air inlet installations · Chemical…
-
General information
Constructive variants SMALL SERIES and OVENS CENTRIFUGAL FANS FOR INDUSTRIAL APPLICATIONS Fans for OVEN STANDARD VERSION HIGH TEMPERATURE VERSION -25 °C / +120 °C -25 °C / +250 °C . Fans built for bread and pastry ovens are ready to operate with high temperatures up to +300 °C . Fans built for…
-
Constructive variants LARGE SERIES
Atex Version The ATEX version must be adopted if the fan is transporting explosive mixtures. The client must always indicate the area where the fan is used, the gas (indicating the type) or dust. High temperature version CENTRIFUGAL FANS FOR INDUSTRIAL APPLICATIONS LARGE SERIES STANDARD VERSION HIGH…
-
COMPLIANCE WITH STANDARDS
SODECA fans and extract fans comply with the following standards: COMPLIANCE ISO 9001:2015 Sistemas de gestión de la calidad. Requisitos. Quality management systems Requirements. TESTING UNE-EN ISO 5801 Ventiladores. Ensayos de comportamiento en circuitos normalizados. Fans Performance testing using…
-
VENTILATION
SOLUTIONS PRESSURISATION SYSTEMS FOR STAIRCASES SMOKE EXTRACTION FOR PARKINGS CMV MULTI-ROOM APARTMENTS ATEX EXTRACT FANS PROFESSIONAL KITCHENS HATCH VENTILATION SYSTEMS VENTILATION SYSTEMS FOR HOMES AIR CURTAINS INDUSTRIAL APPLICATIONS ROOF-MOUNTED EXTRACT FANS AXIAL SOLUTIONS www.sodeca.com 15
-
Centrifugal
fans for industrial applications SMALL SERIES MEDIUM PRESSURE SMALL SERIES 18 CMP Single inlet medium pressure centrifugal fans with sheet steel casing and impeller 36 CBP Centrifugal fans of medium pressure and single inlet, equipped with backward curved impeller with self-cleaning effect…
-
CA Single inlet, high pressure centrifugal fans with cast aluminum casing and impeller 51 CAS-S Single inlet, high pressure centrifugal fans with sheet steel casing and impeller, equipped with acoustic attenuator TRANSPORT 51 CAS Single inlet, high pressure centrifugal fans with sheet steel casing…
-
CMP
Single inlet medium pressure centrifugal fans with sheet steel casing and impeller Finishing: • Anti-corrosive finish in polyester resin, polymerised at 190 ºC, after degreasing with phosphate-free nanotechnology treatment. Fan: • Sheet steel casing. • Forward curved impeller in galvanized sheet…
-
CMP-620-4M
-
CMP-38
-
CMP-922...1231
-
2T=3000 r/min
-
4T=1500 r/min
-
6T=1000 r/min
-
CMPE
Single inlet medium pressure centrifugal fans with external rotor motor Fan: • Sheet steel casing. • Forward curved impeller. • External terminal box with cable entry with cable glands. Finishing: • Anti-corrosive finish in polyester resin, polymerised at 190 ºC, after degreasing with phosphate-free…
-
CMPE-613-2M
-
CRL
Centrifugal medium pressure single inlet fans with backward curved impeller Fan: • Sheet steel casing. • Backward curved impeller made of sheet steel. • Maximum temperature of air to be carried: -20 ºC +120 ºC. Motor: • Motors with IE3 efficiency for powers equal to or greater than 0.75kW, except…
-
CRL-822-1028
-
2T=3000 r/min
-
CMR
Very robust single inlet, medium pressure centrifugal fans, equipped with a backward curved impeller Fan: • Sheet steel casing. • Backward curved impeller in highly robust sheet steel. Finishing: • Anti-corrosive finish in polyester resin, polymerised at 190 ºC, after degreasing with phosphate-free…
-
Erp. (Energy Related Products)
-
CMR-2380
-
2T=3000 r/min
-
Orientations
-
CBP CBPC
CBP: Centrifugal fans of medium pressure and single inlet, equipped with backward curved impeller with self-cleaning effect, specially designed for painting booths CBPC: Centrifugal fans of medium pressure and single inlet, equipped with backward curved impeller with self-cleaning effect, specially…
-
Outlet nozzle
-
CMA
Single inlet medium pressure centrifugal fans with cast aluminum casing and impeller Fan: • Cast aluminium casing. • Cast aluminium impeller. • Models 324, 325 and 426 impeller in polyamide, model 531-2T-3 impeller in sheet steel. Motor: • Motors with IE3 efficiency for powers equal to or greater…
-
Erp. (Energy Related Products)
-
CMA-540...545
-
Orientations
-
CPV
Single inlet anti-corrosive centrifugal fans made of polypropylene Fan: • Polypropylene casing. • Forward curved impeller in polypropylene. Finishing: • Anti-corrosive in plastic material. On request: • Special windings for different voltages. • ATEX certified Category 3. Motor: • Motors with IE3…
-
CPV-1840...2045
-
2T=3000 r/min
-
таблицы и схемы — в просмотре
-
CA
Single inlet, high pressure centrifugal fans with cast aluminum casing and impeller Fan: • Cast aluminium casing. • Cast aluminium impeller. Motor: • Motors with IE3 efficiency for powers equal to or greater than 0.75kW, except single-phase, 2-speed and 8-pole. • Class F motors with ball bearings…
-
CA-154...172
-
Orientations
-
CAS CAS-S
CAS: Single inlet, high pressure centrifugal fans with sheet steel casing and impeller CAS-S: Single inlet, high pressure centrifugal fans with sheet steel casing and impeller, equipped with acoustic attenuator CAS Motor: • Motors with IE3 efficiency for powers equal to or greater than 0.75kW…
-
таблицы и схемы — в просмотре
-
CAS-242...971
-
CAS-790...1090
-
CAS-S-242...971
-
CAS-S-790...1090
-
SMALL SERIES
Accessories INT 58 C2V RM VSD3/A-RFT AET RPA B BIC ACE CJACUS S REG
-
таблицы и схемы — в просмотре
-
CAM
Single inlet, high pressure centrifugal fans with sheet steel casing and cast aluminum impeller Fan: • Sheet steel casing. • Cast aluminium and sheet steel impellers in models 752, 880 and 980. Finishing: • Anti-corrosive finish in polyester resin, polymerised at 190 ºC, after degreasing with…
-
CAM-540...545
-
CAM-980
-
SMALL SERIES
-
CMTS
Medium pressure single inlet centrifugal fans with casing and straight blade impeller, made of sheet steel, for transporting smoke with solid material Fan: • Sheet steel casing. • Straight blade impeller made of sheet steel. Motor: • Motors with IE3 efficiency for powers equal to or greater than…
-
Outlet nozzle
-
CMT
Medium pressure single inlet centrifugal fans with casing and straight blade impeller, made of sheet steel for conveying powder and solid material Fan: • Sheet steel casing. • Straight blade impeller made of sheet steel. Motor: • Motors with IE3 efficiency for powers equal to or greater than 0.75kW…
-
Orientations
-
CMAT
Single-inlet, medium-pressure centrifugal fans with casing and straight blade impeller made of cast aluminum, for conveying powder and solid material Fan: • Cast aluminium casing. • Straight blade impeller in cast aluminium in models 324 to 531 and in sheet steel in models 540 to 545. Finishing: •…
-
CMAT-324...528
-
Orientations
-
PORT
Extremely robust, high power portable air extractors Fan: • Portable extractor with high aspiration power. • For the extraction of dirty and dusty air in facilities where extraction is required in an intermittent and mobile way, specially designed for industrial and agricultural applications.…
-
PORT-1135-2T-3
-
Centrifugal
fans for industrial applications LARGE SERIES MEDIUM PRESSURE 76 CMRS Very robust single inlet, medium pressure centrifugal fans, equipped with a backward curved impeller Designed for clean or slightly dusty air 110 CAMA Extremely robust medium pressure and single inlet centrifugal fans with sheet…
-
HIGH
PRESSURE 190 222 CAAB Extremely robust high pressure single inlet centrifugal fans with sheet steel casing and impeller Designed for clean or dusty air 266 CAST Extremely robust open blade and single inlet centrifugal fans with sheet steel casing and impeller Designed for air that is very dusty and…
-
CMRS
Very robust single inlet, medium pressure centrifugal fans, equipped with a backward curved impeller Designed for clean or slightly dusty air 4 SYSTEM Motor: • Motors with IE3 efficiency for powers equal to or greater than 0.75kW, except single-phase, 2-speed and 8-pole. • Class F motors with ball…
-
Frame
-
6T=1000 r/min
6T=1000 r/min 6T=1000 r/min LARGE SERIES 6T=1000 r/min Accessories INT C2V Drall-Regler Válvula lamas contrapuestas RM VSD3/A-RFT VSD1/A-RFM AET RPA B BD BIC ACE S REG 79
-
CMRS-X
Belt driven fans, equipped with an electric motor, a set of pulleys, belts and protectors standardized according to ISO-13857 Designed for clean or slightly dusty air • Sizes over 1600 are supplied with split casing for easy transport. • Casing continuously welded from size 800 and up. Motor: • IE3…
-
CMRS-X 250
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics Maximum admissible Rpm Class 1 Class 2 ≤ 100ºC 5000 6300 100 200ºC 4500 5600 200 300ºC 4000 5000 81
-
CMRS-X 280
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics 82 Maximum admissible Rpm Class 1 Class 2 ≤ 100ºC 4000 5000 100...200ºC 3550 4500 200...300ºC 3150 4000
-
CMRS-X 310
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics Maximum admissible Rpm Class 1 Class 2 Class 3 ≤ 100ºC 3150 4000 5000 100...200ºC 2800 3550 4500 200...300ºC 2500 3150 4000 83
-
CMRS-X 350
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics 84 Maximum admissible Rpm Class 1 Class 2 Class 3 ≤ 100ºC 2800 3550 4500 100...200ºC 2500 3150 4000 200...300ºC 2240 2800 3550
-
CMRS-X 400
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics Maximum admissible Rpm Class 1 Class 2 Class 3 ≤ 100ºC 2500 3150 4000 100...200ºC 2240 2800 3550 200...300ºC 2000 2500 3150 85
-
CMRS-X 450
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics 86 Maximum admissible Rpm Class 1 Class 2 Class 3 ≤ 100ºC 2240 2800 3550 100...200ºC 2000 2500 3150 200...300ºC 1800 2250 2800
-
CMRS-X 500
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics Maximum admissible Rpm Class 1 Class 2 Class 3 ≤ 100ºC 2000 2500 3150 100...200ºC 1800 2240 2800 200...300ºC 1600 2000 2500 87
-
CMRS-X 560
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics 88 Maximum admissible Rpm Class 1 Class 2 Class 3 ≤ 100ºC 1800 2240 2800 100...200ºC 1600 2000 2500 200...300ºC 1400 1800 2240
-
CMRS-X 630
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics Maximum admissible Rpm Class 1 Class 2 Class 3 ≤ 100ºC 1600 2000 2500 100...200ºC 1400 1800 2240 200...300ºC 1250 1600 2000 89
-
CMRS-X 710
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics 90 Maximum admissible Rpm Class 1 Class 2 Class 3 ≤ 100ºC 1400 1800 2240 100...200ºC 1250 1600 2000 200...300ºC 1120 1400 1800
-
CMRS-X 800
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics Maximum admissible Rpm Class 1 Class 2 Class 3 ≤ 100ºC 1250 1600 2000 100...200ºC 1120 1400 1800 200...300ºC 1000 1250 1600 91
-
CMRS-X 900
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics 92 Maximum admissible Rpm Class 1 Class 2 Class 3 ≤ 100ºC 1120 1400 1800 100...200ºC 1000 1250 1600 200...300ºC 900 1120 1400
-
CMRS-X 1000
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics Maximum admissible Rpm Class 1 Class 2 Class 3 ≤ 100ºC 1000 1250 1600 100...200ºC 900 1120 1400 200...300ºC 800 1000 1250 93
-
CMRS-X 1120
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics 94 Maximum admissible Rpm Class 1 Class 2 Class 3 ≤ 100ºC 900 1120 1400 100...200ºC 800 1000 1250 200...300ºC 710 900 1120
-
CMRS-X 1250
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics Maximum admissible Rpm Class 1 Class 2 Class 3 ≤ 100ºC 800 1000 1250 100...200ºC 710 900 1120 200...300ºC 630 800 1000 95
-
CMRS-X 1400
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics 96 Maximum admissible Rpm Class 1 Class 2 Class 3 ≤ 100ºC 710 900 1120 100...200ºC 630 800 1000 200...300ºC
-
CMRS-X 1600
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics Maximum admissible Rpm Class 1 Class 2 Class 3 ≤ 100ºC 630 800 1000 100...200ºC 200...300ºC
-
CMRS-X 1800
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics 98 Maximum admissible Rpm Class 1 Class 2 Class 3 ≤ 100ºC 100...200ºC 200...300ºC
-
CMRS-X 2000
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics Maximum admissible Rpm Class 1 Class 2 Class 3 ≤ 100ºC 100...200ºC 200...300ºC
-
SYSTEM
-
таблицы и схемы — в просмотре
-
SYSTEM
-
CMRS-X 250...500
-
CMRS-X 560...800
-
CMRS-X 900...2000
-
Impulsion counter-flange
nº - Ø drill holes Inlet protection mesh Arm LARGE SERIES 106 MOD. d d1 d2 nº Φ S CMRS-250 kg 1 CMRS-280 1.6 CMRS-310 1.8 CMRS-350 CMRS-400 2.2 CMRS-450 2.5 CMRS-500 2.7 CMRS-560 4.6 CMRS-630 CMRS-710 5.5 CMRS-800 CMRS-900 908 958 1008 CMRS-1000 1008 1067 1108 7.8 CMRS-1120 1130 1200 1250 13.8…
-
Inlet anti-vibration seal
nº - Ø drill holes Impulsion anti-vibration seal nº - Ø drill holes Flow regulator at the inlet nº - Ø drill holes MOD. d d1 d2 nº Φ H kg CMRS-250 2.2 CMRS-280 3.4 CMRS-310 3.8 CMRS-350 4.2 CMRS-400 4.6 CMRS-450 5.1 CMRS-500 5.6 CMRS-560 9.4 CMRS-630 10.4 CMRS-710 11.6 CMRS-800 CMRS-900 908 958 1008…
-
Opposing blades damper
-
CAMA
Extremely robust medium pressure and single inlet centrifugal fans with sheet steel casing and impeller Designed for dusty air Motor: • Motors with IE3 efficiency for powers equal to or greater than 0.75kW, except single-phase, 2-speed and 8-pole. • Class F motors with ball bearings, IP55…
-
CAMA-X
Belt driven medium pressure fans, equipped with an electric motor, a set of pulleys, belts and protectors standardized according to ISO-13857 Designed for dusty air Motor: • IE3 efficiency motors. • Class F motors with ball bearings, IP55 protection. • Three-phase 230/400 V 50 Hz (up to 4 kW) and…
-
Outlet characteristics
-
таблицы и схемы — в просмотре
-
Inlet characteristics
-
таблицы и схемы — в просмотре
-
CAMA 250
LARGE SERIES Flow margin ±5% Noise level margin +3 db Margin of kW absorbed ±3% Outlet characteristics. 116 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 5600 100 200 ⁰C 5000 200 300 ⁰C 4500 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
CAMA 280
Flow margin ±5% Noise level margin +3 db Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 5000 100 200 ⁰C 4500 200 300 ⁰C 4000 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 117
-
CAMA 310
LARGE SERIES Flow margin ±5% Noise level margin +3 db Margin of kW absorbed ±3% Outlet characteristics. 118 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 4500 100 200 ⁰C 4000 200 300 ⁰C 3550 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
CAMA 350
Flow margin ±5% Noise level margin +3 db Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 4000 100 200 ⁰C 3550 200 300 ⁰C 3150 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 119
-
CAMA 400
LARGE SERIES Flow margin ±5% Noise level margin +3 db Margin of kW absorbed ±3% Outlet characteristics. 120 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 3550 100 200 ⁰C 3150 200 300 ⁰C 2800 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
CAMA 450
Flow margin ±5% Noise level margin +3 db Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 3150 100 200 ⁰C 2800 200 300 ⁰C 2500 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 121
-
CAMA 500
LARGE SERIES Flow margin ±5% Noise level margin +3 db Margin of kW absorbed ±3% Outlet characteristics. 122 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 2800 100 200 ⁰C 2500 200 300 ⁰C 2250 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
CAMA 560
Flow margin ±5% Noise level margin +3 db Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 2500 100 200 ⁰C 2250 200 300 ⁰C 2000 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 123
-
CAMA 630
LARGE SERIES Flow margin ±5% Noise level margin +3 db Margin of kW absorbed ±3% Outlet characteristics. 124 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 2250 100 200 ⁰C 2000 200 300 ⁰C 1800 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
CAMA 710
Flow margin ±5% Noise level margin +3 db Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 2000 100 200 ⁰C 1800 200 300 ⁰C 1600 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 125
-
CAMA 800
LARGE SERIES Flow margin ±5% Noise level margin +3 db Margin of kW absorbed ±3% Outlet characteristics. 126 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 1800 100 200 ⁰C 1600 200 300 ⁰C 1400 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
CAMA 900
Flow margin ±5% Noise level margin +3 db Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 1600 100 200 ⁰C 1400 200 300 ⁰C 1250 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 127
-
CAMA 1000
LARGE SERIES Flow margin ±5% Noise level margin +3 db Margin of kW absorbed ±3% Outlet characteristics. 128 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 1400 100 200 ⁰C 1250 200 300 ⁰C 1120 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
CAMA 1120
Flow margin ±5% Noise level margin +3 db Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 1250 100 200 ⁰C 1120 200 300 ⁰C 1000 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 129
-
CAMA 1250
LARGE SERIES Flow margin ±5% Noise level margin +3 db Margin of kW absorbed ±3% Outlet characteristics. 130 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 1120 100 200 ⁰C 1000 200 300 ⁰C 900 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
CAMA 1400
Flow margin ±5% Noise level margin +3 db Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 1000 100 200 ⁰C ⁰C 800 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 131
-
CAMA 1600
LARGE SERIES Flow margin ±5% Noise level margin +3 db Margin of kW absorbed ±3% 132 Maximum admissible Rpm Class 1 ≤ 100 ⁰C ⁰C ⁰C 710
-
CAMA 1800
Flow margin ±5% Noise level margin +3 db Margin of kW absorbed ±3% Maximum admissible Rpm Class 1 ≤ 100 ⁰C ⁰C ⁰C 630 133
-
CAMA 2000
LARGE SERIES Flow margin ±5% Noise level margin +3 db Margin of kW absorbed ±3% 134 Maximum admissible Rpm Class 1 ≤ 100 ⁰C ⁰C ⁰C 560
-
SYSTEM
-
таблицы и схемы — в просмотре
-
SYSTEM
-
CAMA-X 250...500
-
CAMA-X 560...630
-
CAMA-X 710...2000
-
Impulsion counter-flange
nº - Ø drill holes Inlet protection mesh Arm MOD. d d1 d2 nº Φ S kg CAMA 0.7 CAMA 0.75 CAMA 0.8 CAMA CAMA 1.6 CAMA 1.8 CAMA CAMA 2.2 CAMA 2.5 CAMA 2.7 CAMA 4.6 CAMA CAMA 1000 5.5 CAMA 1120 6.2 CAMA 1250 908 958 1008 CAMA 1400 1008 1067 1108 7.8 CAMA 1600 1130 1200 1250 CAMA 1800 1260 1337 1380 15.5…
-
Inlet anti-vibration seal
nº - Ø drill holes Impulsion anti-vibration seal nº - Ø drill holes Flow regulator at the inlet nº - Ø drill holes LARGE SERIES 142 MOD. d d1 d2 nº Φ H kg CAMA 1.7 CAMA 1.8 CAMA CAMA 2.2 CAMA 3.4 CAMA 3.8 CAMA 4.2 CAMA 4.6 CAMA 5.1 CAMA 5.6 CAMA 9.4 CAMA 10.4 CAMA 1000 11.6 CAMA 1120 CAMA 1250 908…
-
Opposing blades damper
-
CAMC
Extremely robust medium pressure and single inlet centrifugal fans with sheet steel casing and impeller Designed for dusty air Motor: • Motors with IE3 efficiency for powers equal to or greater than 0.75kW, except single-phase, 2-speed and 8-pole. • Class F motors with ball bearings, IP55…
-
CAMC-X
Belt driven medium pressure fans, equipped with an electric motor, a set of pulleys, belts and protectors standardized according to ISO-13857 Designed for dusty air Motor: • IE3 efficiency motors. • Class F motors with ball bearings, IP55 protection. • Three-phase 230/400 V 50 Hz (up to 4 kW) and…
-
Outlet characteristics
-
CAMC 360
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 147
-
CAMC 380
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 148 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
CAMC 410
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 149
-
CAMC 440
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 150 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
CAMC 470
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 151
-
CAMC 500
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 152 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
CAMC 520
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 153
-
CAMC 550
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 154 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
CAMC 560
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 155
-
CAMC 600
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 156 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
SYSTEM
-
MOD
d d¹ d² n° Φ s kg CAMC 0.65 CAMC 0.65 CAMC 0.75 CAMC 0.75 CAMC CAMC CAMC 1.6 CAMC 1.6 CAMC 1.8 CAMC 1.8 Impulsion counter-flange MOD. a b a¹ b¹ a² b² n¹p n²p n⁰ Φ s kg CAMC - 1--90 0.4 CAMC - 1--90 0.4 CAMC - 1--90 0.45 CAMC 1--90 1--90 0.5 CAMC 1--90 2--90 0.7 CAMC 1--90 2--90 0.7 CAMC 1--90 2--90…
-
таблицы и схемы — в просмотре
-
CAMD
Extremely robust medium pressure and single inlet centrifugal fans with sheet steel casing and impeller Designed for dusty air Motor: • Motors with IE3 efficiency for powers equal to or greater than 0.75kW, except single-phase, 2-speed and 8-pole. • Class F motors with ball bearings, IP55…
-
CAMD-X
Belt driven medium pressure fans, equipped with an electric motor, a set of pulleys, belts and protectors standardized according to ISO-13857 Designed for dusty air Motor: • IE3 efficiency motors. • Class F motors with ball bearings, IP55 protection. • Three-phase 230/400 V 50 Hz (up to 4 kW) and…
-
Outlet characteristics
-
таблицы и схемы — в просмотре
-
Inlet characteristics
-
таблицы и схемы — в просмотре
-
CAMD 400
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 166 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 6000 100... 200 ⁰C 5300 200... 300 ⁰C 4750 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the…
-
CAMD 450
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 5300 100... 200 ⁰C 4750 200... 300 ⁰C 4250 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 167
-
CAMD 500
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 168 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 4750 100... 200 ⁰C 4250 200... 300 ⁰C 3750 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the…
-
CAMD 560
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 4250 100... 200 ⁰C 3750 200... 300 ⁰C 3350 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 169
-
CAMD 630
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 170 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 3750 100... 200 ⁰C 3350 200... 300 ⁰C 3000 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the…
-
CAMD 710
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 3350 100... 200 ⁰C 3000 200... 300 ⁰C 2650 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 171
-
CAMD 800
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 172 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 3000 100... 200 ⁰C 2650 200... 300 ⁰C 2360 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the…
-
CAMD 900
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 2650 100... 200 ⁰C 2360 200... 300 ⁰C 2120 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 173
-
CAMD 1000
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 174 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 2360 100... 200 ⁰C 2120 200... 300 ⁰C 1900 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the…
-
CAMD 1120
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 2120 100... 200 ⁰C 1900 200... 300 ⁰C 1700 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 175
-
CAMD 1250
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 176 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 1900 100... 200 ⁰C 1700 200... 300 ⁰C 1500 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the…
-
CAMD 1400
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 1700 100... 200 ⁰C 1500 200... 300 ⁰C 1320 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 177
-
CAMD 1600
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 178 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 1500 100... 200 ⁰C 1320 200... 300 ⁰C 1180
-
CAMD 1800
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 1320 100... 200 ⁰C 1180 200... 300 ⁰C 1060 179
-
CAMD 2000
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 180 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 1180 100... 200 ⁰C 1060 200... 300 ⁰C 930
-
SYSTEM
-
таблицы и схемы — в просмотре
-
SYSTEM
-
таблицы и схемы — в просмотре
-
CAMD-X 400...500
-
CAMD-X 560...630
-
CAMD-X 710...2000
-
Impulsion counter-flange
nº - Ø drill holes Inlet protection mesh Arm LARGE SERIES Impulsion anti-vibration seal nº - Ø drill holes 188 MOD. d d¹ d² n° Φ s CAMD kg 1 CAMD 1.6 CAMD 1.8 CAMD CAMD 2.2 CAMD 2.5 CAMD 2.7 CAMD 4.6 CAMD 1000 CAMD 1120 5.5 CAMD 1250 6.2 CAMD 1400 908 958 1008 CAMD 1600 1008 1067 1108 7.8 CAMD 1800…
-
Inlet anti-vibration seal
-
CASB
Extremely robust, high pressure, single inlet centrifugal fans with sheet steel casing and impeller Designed for dusty air 4 SYSTEM Motor: • Motors with IE3 efficiency for powers equal to or greater than 0.75kW, except single-phase, 2-speed and 8-pole. • Class F motors with ball bearings, IP55…
-
Frame
-
INT
192 C2V RM VSD3/A-RFT VSD1/A-RFM AET RPA B BD BIC ACE S REG Drall-Regler Válvula lamas contrapuestas
-
CASB-X
Belt driven medium pressure fans, equipped with an electric motor, a set of pulleys, belts and protectors standardized according to ISO-13857 Designed for dusty air • Casing continuously welded starting with size 710. Motor: • IE3 efficiency motors. • Class F motors with ball bearings, IP55…
-
CASB-X 250
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 194 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 5000 101 200 ⁰C 4500 201 300 ⁰C 4000
-
CASB-X 280
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 4750 101 200 ⁰C 4250 201 300 ⁰C 3750 195
-
CASB-X 310
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 196 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 4500 101 200 ⁰C 4000 201 300 ⁰C 3550
-
CASB-X 350
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 4250 101 200 ⁰C 3750 201 300 ⁰C 3350 197
-
CASB-X 400
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 198 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 4000 101 200 ⁰C 3550 201 300 ⁰C 3150
-
CASB-X 450
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 3750 101 200 ⁰C 3350 201 300 ⁰C 3000 199
-
CASB-X 500
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 200 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 3550 101 200 ⁰C 3150 201 300 ⁰C 2800
-
CASB-X 560
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 3350 101 200 ⁰C 3000 201 300 ⁰C 2650 201
-
CASB-X 630
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 202 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 3150 101 200 ⁰C 2800 201 300 ⁰C 2500
-
CASB-X 710
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 2800 101 200 ⁰C 2500 201 300 ⁰C 2240 203
-
CASB-X 800
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 204 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 2500 101 200 ⁰C 2240 201 300 ⁰C 2000
-
CASB-X 900
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 2240 101 200 ⁰C 2000 201 300 ⁰C 1800 205
-
CASB-X 1000
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 206 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 2000 101 200 ⁰C 1800 201 300 ⁰C 1600
-
CASB-X 1120
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 1800 101 200 ⁰C 1600 201 300 ⁰C 1400 207
-
CASB-X 1250
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 208 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 1600 101 200 ⁰C 1400 201 300 ⁰C 1250
-
CASB-X 1400
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 1400 101 200 ⁰C 1250 201 300 ⁰C 1120 209
-
CASB-X 1600
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% 210 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 1250 101 200 ⁰C 1120 201 300 ⁰C 1000
-
CASB-X 1800
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Maximum admissible Rpm Class 1 ≤ 100 ⁰C 1120 101 200 ⁰C 1000 201 300 ⁰C 900 211
-
CASB-X 2000
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% 212 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 1000 101 200 ⁰C ⁰C 800
-
SYSTEM
-
таблицы и схемы — в просмотре
-
SYSTEM
-
CASB-X 250...500
-
CASB-X 560...630
-
Impulsion counter-flange
nº - Ø drill holes Inlet protection mesh Arm MOD. d d¹ d² n° Φ s kg CASB 0.75 CASB 0.8 CASB CASB 1.6 CASB 1.8 CASB CASB 2.2 CASB 2.5 CASB 2.7 CASB 4.6 CASB CASB 5.5 CASB 1000 6.2 CASB 1120 908 958 1008 CASB 1250 1008 1067 1108 7.8 CASB 1400 1130 1200 1250 CASB 1600 1260 1337 1380 15.5 CASB 1800 1410…
-
Inlet anti-vibration seal
nº - Ø drill holes Impulsion anti-vibration seal nº - Ø drill holes Flow regulator at the inlet nº - Ø drill holes LARGE SERIES 220 MOD. d d¹ d² n° Φ H kg CASB 1.8 CASB CASB 2.2 CASB 3.4 CASB 3.8 CASB 4.2 CASB 4.6 CASB 5.1 CASB 5.6 CASB 9.4 CASB 10.4 CASB 11.6 CASB 1000 CASB 1120 908 958 1008 14.4…
-
Opposing blades damper
-
CAAB
Extremely robust high pressure single inlet centrifugal fans with sheet steel casing and impeller Designed for clean or dusty air Motor: • Motors with IE3 efficiency for powers equal to or greater than 0.75kW, except single-phase, 2-speed and 8-pole. • Class F motors with ball bearings, IP55…
-
Frame
-
INT
C2V Drall-Regler Válvula lamas contrapuestas 224 RM VSD3/A-RFT VSD1/A-RFM AET RPA B BD BIC ACE S REG
-
CAAB-X
Belt driven high pressure fans fitted with electric motors and a standardised set of pulleys, belts and protectors in accordance with standard ISO 13857 Designed for clean or dusty air Motor: • IE3 efficiency motors. • Class F motors with ball bearings, IP55 protection. • Three-phase 230/400 V 50 Hz…
-
CAAB-X 400
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 226 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 4500 101 200 ⁰C 4000 201 300 ⁰C 3550
-
CAAB-X 450
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 4250 101 200 ⁰C 3750 201 300 ⁰C 3350 227
-
CAAB-X 500
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 228 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 4000 101 200 ⁰C 3550 201 300 ⁰C 3150
-
CAAB-X 560
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 3750 101 200 ⁰C 3350 201 300 ⁰C 3000 229
-
CAAB-X 630
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 230 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 3550 101 200 ⁰C 3150 201 300 ⁰C 2800
-
CAAB-X 710
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 3350 101 200 ⁰C 3000 201 300 ⁰C 2650 231
-
CAAB-X 800
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 232 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 3150 101 200 ⁰C 2800 201 300 ⁰C 2500
-
CAAB-X 900
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Maximum admissible Rpm Class 1 ≤ 100 ⁰C 3000 101 200 ⁰C 2650 201 300 ⁰C 2360 233
-
CAAB-X 1000
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 234 Maximum admissible Rpm Class 1 ≤ 100 ⁰C 2800 101 200 ⁰C 2500 201 300 ⁰C 2240
-
SYSTEM
-
таблицы и схемы — в просмотре
-
CAAB-X 400...1000
-
MOD
-
Flow regulator at the inlet
-
CAAE
Extremely robust high pressure single inlet centrifugal fans with sheet steel casing and impeller Designed for clean or dusty air Motor: • Motors with IE3 efficiency for powers equal to or greater than 0.75kW, except single-phase, 2-speed and 8-pole. • Class F motors with ball bearings, IP55…
-
CAAE-X
Belt driven high pressure fans fitted with electric motors and a standardised set of pulleys, belts and protectors in accordance with standard ISO 13857 Designed for clean or dusty air Motor: • IE3 efficiency motors. • Class F motors with ball bearings, IP55 protection. • Three-phase 230/400 V 50 Hz…
-
Outlet characteristics
-
Inlet characteristics
-
CAAE 400
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 244 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
CAAE 500
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 245
-
CAAE 630
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 246 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
CAAE 710
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 247
-
CAAE 800
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 248 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
CAAE 900
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 249
-
SYSTEM
-
Inlet anti-vibration seal
-
CAAF
Extremely robust high pressure single inlet centrifugal fans with sheet steel casing and impeller Designed for clean or dusty air Motor: • Motors with IE3 efficiency for powers equal to or greater than 0.75kW, except single-phase, 2-speed and 8-pole. • Class F motors with ball bearings, IP55…
-
CAAF-X
Belt driven high pressure fans fitted with electric motors and a standardised set of pulleys, belts and protectors in accordance with standard ISO 13857 Designed for clean or dusty air Motor: • IE3 efficiency motors. • Class F motors with ball bearings, IP55 protection. • Three-phase 230/400 V 50 Hz…
-
Outlet characteristics
-
Inlet characteristics
-
CAAF 475
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 256 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
CAAF 560
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 257
-
CAAF 630
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 258 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
CAAF 710
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 259
-
CAAF 800
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 260 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
CAAF 900
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 261
-
SYSTEM
-
таблицы и схемы — в просмотре
-
MOD
-
таблицы и схемы — в просмотре
-
CAST
Extremely robust open blade and single inlet centrifugal fans with sheet steel casing and impeller Designed for air that is very dusty and with materials suspended in the air 4 SYSTEM Motor: • Motors with IE3 efficiency for powers equal to or greater than 0.75kW, except single-phase, 2-speed and…
-
Frame
-
CAST-X
Centrifugal, open blade, belt driven fans fitted with electric motors and a standardised set of pulleys, belts and protectors in accordance with standard ISO 13857 Designed for air that is very dusty and with materials suspended in the air Motor: • IE3 efficiency motors. • Class F motors with ball…
-
CAST-X 400
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 269
-
CAST-X 450
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 270
-
CAST-X 500
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 271
-
CAST-X 560
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 272
-
CAST-X 630
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 273
-
CAST-X 710
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 274
-
CAST-X 800
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 275
-
CAST-X 900
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 276
-
CAST-X 1000
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 277
-
SYSTEM
-
CAST-X 400...900
-
MOD
-
таблицы и схемы — в просмотре
-
CMTB
Extremely robust open blade and single inlet centrifugal fans with sheet steel casing and impeller Designed for air that is very dusty and with materials suspended in the air Motor: • Motors with IE3 efficiency for powers equal to or greater than 0.75kW, except single-phase, 2-speed and 8-pole. •…
-
CMTB-X
Centrifugal, open blade, belt driven fans fitted with electric motors and a standardized set of pulleys, belts and protectors in accordance with standard ISO 13857 Designed for air that is very dusty and with materials suspended in the air Motor: • IE3 efficiency motors. • Class F motors with ball…
-
Outlet characteristics
-
CMTB 250
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 285
-
CMTB 280
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 286 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
CMTB 310
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 287
-
CMTB 350
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 288 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
CMTB 400
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 289
-
CMTB 450
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 290 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
CMTB 470
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 291
-
SYSTEM
-
Inlet anti-vibration seal
-
CMTC
Extremely robust open blade and single inlet centrifugal fans with sheet steel casing and impeller Designed for air that is very dusty and with materials suspended in the air Motor: • Motors with IE3 efficiency for powers equal to or greater than 0.75kW, except single-phase, 2-speed and 8-pole. •…
-
CMTC-X
Centrifugal, open blade, belt driven fans fitted with electric motors and a standardized set of pulleys, belts and protectors in accordance with standard ISO 13857 Designed for air that is very dusty and with materials suspended in the air Motor: • IE3 efficiency motors. • Class F motors with ball…
-
Outlet characteristics
-
CMTC 630
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 297
-
CMTC 670
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 298 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
CMTC 700
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 299
-
CMTC 750
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 300 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
CMTC 800
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 301
-
CMTC 835
LARGE SERIES Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. 302 Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model.
-
CMTC 855
Flow margin ±5% Noise level margin + 3... 5 dB Margin of kW absorbed ±3% Outlet characteristics. Rpm Characteristics for: system 4 and 5 in direct drive motor with 2/4/6/8 poles depending on the model. 303
-
SYSTEM
-
CMTC-X 630...855
-
MOD
-
таблицы и схемы — в просмотре
-
ovens
FANS FOR BREAD AND PASTRY OVENS 310 SDECB/M Centrifugal fans especially designed for extracting hot air at a max. temperature of 80 °C and water vapour from extract hoods with a vertical air outlet. Especially designed for bread and pastry ovens as well as industrial ovens. 315 OVENS SDECB/MGC…
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.