Технический каталог Sinclair 2025 - Коммерческие системы – Кондиционеры SDV, Чиллеры, Фанкойлы
Загружаем документ…
Текст каталога
-
V025-EN-01
TECHNICAL CATALOGUE COMMERCIAL SYSTEMS 2025 · OUTDOOR UNITS SDV6 · OUTDOOR UNITS SDV5 · OUTDOOR UNITS SDV5-3P · SDB SDV5-3P · INDOOR UNITS SDV6 · HIGH STATIC PRESSURE DUCT SERIES · CONTROLLERS · BMS SYSTEMS · MINI CHILLERS · MODULAR CHILLERS · FAN COIL UNITS AIR CONDITIONING
-
CONTAIN SMALL INDIVIDUAL SIDE DISCHARGE AIR OUTDOOR UNITS SDV6 R32 2 SMALL INDIVIDUAL SIDE DISCHARGE AIR OUTDOOR UNITS SDV6 R410A 5 INDIVIDUAL SIDE DISCHARGE AIR OUTDOOR UNITS SDV5 8 INDIVIDUAL SIDE DISCHARGE AIR OUTDOOR UNITS SDV6 10 TOP AIR DISCHARGE INDIVIDUAL OUTDOOR UNITS SDV6 12 TOP AIR…
-
MODEL
Horse power (HP) Power SDV6-E80BS SDV6-E100BS SDV6-E120BS SDV6-E140BS - 2,5 3,5 4,4 5 SDV6-E160BS 6 phase / Hz / V 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 Cooling capacity kW 7,2 9 12,3 14 15,5 Cooling input power kW 1,95 2,77 3,73 4,67 5,34 EER…
-
MODEL
Horse power (HP) Power SDV6-E180BS SDV6-E120BS-3 SDV6-E140BS-3 SDV6-E160BS-3 - 6,4 4,4 5 6 SDV6-E180BS-3 6,4 phase / Hz / V 1 ~ / 50 / 220-240 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 17,5 Cooling capacity kW 17,5 12,3 14 15,5 Cooling input power kW 6,46 3,37 4,67…
-
Model SDV6-E80-180BS/BS-3 A (mm) 1038 B (mm) 1073 C (mm) 454 D (mm) 409 E (mm) 191 F (mm) 656 G (mm) 864 H (mm) 463 I (mm) 523 ALLOWED LENGHT AND DROP HEIGHT OF CONNECTION (See installation manual) Additional refrigerant: Calculate the added refrigerant according to the diameter and the length of…
-
MODEL
Horse power (HP) Power SDV6-E80AS SDV6-E100AS SDV6-E120AS - 2,5 3,5 4,4 SDV6-E140AS 5 phase / Hz / V 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 Cooling capacity kW 7,2 9 12,3 14 Cooling input power kW 2,21 2,9 3,97 5,19 EER - 3,26 3,10 3,10 2,70 5,40 5,40 7,20 7,00…
-
MODEL
Horse power (HP) Power SDV6-E160AS SDV6-E120AS-3 SDV6-E140AS-3 - 6 4,4 5 SDV6-E160AS-3 6 phase / Hz / V 1 ~ / 50 / 220-240 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 Cooling capacity kW 15,5 12,3 14 15,5 Cooling input power kW 5,96 3,97 5,19 5,96 EER - 2,60 3,10 2,70 2,60 6,80 7,20…
-
SDV5 INDIVIDUAL SIDE DISCHARGE
SDV5-200EAS SDV5-224EAS SDV5-260EAS SDV5-280EAS - phase / Hz / V 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 MODEL Horse power (HP) Power SDV5-335EAS Cooling capacity kW 20 22,4 26 28 33,5 Cooling input power kW 5,28 6,77 10,04 12,02 15,30 EER…
-
SDV5 INDIVIDUAL SIDE DISCHARGE
1558 2 Installation space (Unit:mm) SDV5-200EAS/224EAS/260EAS/280EAS/335EAS 1120 Fig.3-1 ALLOWED LENGHT AND DROP HEIGHT OF CONNECTION (See installation manual) Additional refrigerant: Calculate the added refrigerant according to the diameter and the length of the liquid side pipe of the outdoor…
-
SDV6 INDIVIDUAL SIDE DISCHARGE
MODEL Horse power (HP) Power SDV6-E400ASI SDV6-E450ASI SDV6-E500ASI SDV6-E560ASI - SDV6-E615ASI 22 phase / Hz / V 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 Cooling capacity kW 61,5 Cooling input power kW 15,7 16 19,5 22,9 30,8 EER - 2,55 2,81 2,56…
-
SDV6 INDIVIDUAL SIDE DISCHARGE
SDV6-E400ASI SDV6-E450/500/560/615ASI ALLOWED LENGHT AND DROP HEIGHT OF CONNECTION (See installation manual) Additional refrigerant: Calculate the added refrigerant according to the diameter and the length of the liquid side pipe of the outdoor unit/indoor unit connection. When the outdoor unit…
-
MODEL
SDV6-E252ATI / SDV6-E252ATM Horse power (HP) Power SDV6-E280ATI / SDV6-E280ATM SDV6-E335ATI / SDV6-E335ATM SDV6-E400ATI / SDV6-E400ATM SDV6-E450ATI / SDV6-E450ATM - phase / Hz / V 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 Cooling capacity kW 25,2…
-
MODEL
SDV6-E500ATI / SDV6-E500ATM Horse power (HP) Power SDV6-E560ATI / SDV6-E560ATM SDV6-E615ATI / SDV6-E615ATM SDV6-E670ATI / SDV6-E670ATM SDV6-E730ATI / SDV6-E730ATM - phase / Hz / V 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 Cooling capacity kW 50,0…
-
MODEL
SDV6-E785ATI / SDV6-E785ATM Horse power (HP) Power SDV6-E850ATI / SDV6-E850ATM SDV6-E900ATI / SDV6-E900ATM - phase / Hz / V 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 Cooling capacity kW 78,5 85,0 90,0 Cooling input power kW 32,44 37,78 43,90 EER - 2,42 2,25 2,05 Heating capacity kW…
-
EXPANSION BOLT POSITIONING
CONNECTION PIPPING DIMENSIONS SDV6 TOP AIR DISCHARGE INDIVIDUAL / SDV6 TOP AIR DISCHARGE MODULAR ALLOWED LENGHT AND DROP HEIGHT OF CONNECTION See installation manual MODULAR OUTDOOR UNIT CONNECTION ONLY SDV6-ExxxATM series Additional refrigerant: Calculate the added refrigerant according to the…
-
MODEL
SDV5-252EA3P SDV5-280EA3P SDV5-335EA3P SDV5-400EA3P - phase / Hz / V 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 Cooling capacity kW 22,4 28,0 33,5 40,0 45,0 Cooling input power kW 6,55 9,79 11,88 13,2 17,44 Horse power (HP) Power SDV5-450EA3P EER…
-
MODEL
SDV5-500EA3P Horse power (HP) Power - 18 phase / Hz / V 3 ~ / 50 / 380-415 APPEARANCE AND DIMENSIONS OF OUTDOOR UNIT 8, 10, 12 HP Cooling capacity kW 50,0 Cooling input power kW 22,03 EER - 2,27 Heating capacity kW 50,0 Heating input power kW 13,48 COP - 3,71 Combination of indoor units - 50-200 %…
-
31.8 31.8 31.8 38.1 APPEARANCE AND DIMENSIONS OF OUTDOOR UNIT POSITION ILLUSTRATION OF SCREW BOLT SDV5-3P HEAT RECOVERY MODULAR Expansion bolt positioning (Unit: mm) B 8-12 HP D A C 25.4 15×23 U-shaped hole Fig.4-12 14-18 HP Table.4-3 HP SIZE ALLOWED LENGHT AND DROP HEIGHT OF CONNECTION (See…
-
Example for power wire connection Power(380-415V 3Na50/60Hz) L1 L2 L3 N $ % & 1 Branch Box Outdoor unit(master unit) Outdoor unit(slave unit) Outdoor unit(slave unit) $ $ $ % & 1 Branch Box ( % & 1 + + ( 3 4 ( % & 1 + + ( 3 4 ( Signal wire between outdoor units SDB / + + ( 3 4 ( 3 4 ( Signal wire…
-
DISTRIBUTION BOXES
-
ELECTRICAL WIRING AND PIPING LINES
-
SDV6 COMPACT FOUR WAY CASSETTE
MODEL Capacity cooling/heating Power supply SDV6-CC15 SDV6-CC22 SDV6-CC28 kW 1,5/1,8 2,2/2,4 2,8/3,2 SDV6-CC36 3,6/4,0 phase / Hz / V 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 Power input W Air flow of ID m3/h 450/425/400/370/ 345/320/295 450/425/400/370/…
-
SDV6 COMPACT FOUR WAY CASSETTE
MODEL Capacity cooling/heating Power supply SDV6-CC45 SDV6-CC56 kW 4,5/5,0 5,6/6,3 SDV6-CC63 6,3/7,1 phase / Hz / V 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 Power input W Air flow of ID m3/h 640/605/570/530/ 495/460/425 810/765/720/670/ 625/580/535 905/855/805/755/ 705/655/605 Sound…
-
SDV6 FOUR WAY CASSETTE
MODEL Capacity cooling/heating Power supply SDV6-C71 SDV6-C80 SDV6-C90 SDV6-C100 kW 7,1/8,0 8,0/9,0 9,0/10,0 10,0/11,0 SDV6-C112 11,2/12,5 phase / Hz / V 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 54 61 Power input W Air flow of ID m3/h…
-
SDV6 FOUR WAY CASSETTE
MODEL SDV6-C140 Capacity cooling/heating Power supply kW 14,0/16,0 phase / Hz / V 1 ~ / 50 / 220-240 Power input W 89 Air flow of ID SH/MH/H/M/L/ ML/SL m3/h 1600/1497/1393/1290/1186/1083/979 dB(A) 43/42/40/39/37/36/34 dB(A) - Net dimensions of ID wxhxd mm 840x288x840 Net dimensions of panel wxhxd mm…
-
SDV6 ONE WAY CASSETTE
MODEL Capacity cooling/heating Power supply Power input Air flow of ID SH/MH/H/M/L/ML/SL SDV6-1C18 SDV6-1C22 SDV6-1C28 SDV6-1C36 kW 1,8/2,2 2,2/2,6 2,8/3,2 3,6/4,0 SDV6-1C45 4,5/5,0 phase / Hz / V 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 W m3/h…
-
SDV6 ONE WAY CASSETTE
SDV6-1C56 MODEL Capacity cooling/heating Power supply SDV6-1C71 kW 5,6/6,3 7,1/8,0 phase / Hz / V 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 W 48 60 m3/h 792/763/728/688/6 43/589/549 933/873/815/749/ 689/637/592 Sound pressure level at 1,4m dB(A) 41/39/38/37/36/35/33 43/41/40/39/37/36/35 Sound power…
-
SDV6 WALL-MOUNTED
MODEL Capacity cooling/heating Power supply SDV6-H(F)15(S) SDV6-H(F)22(S) SDV6-H(F)28(S) kW 1,5/1,8 2,2/2,4 2,8/3,2 SDV6-H(F)36(S) 3,6/4,0 phase / Hz / V 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 Power input W Air flow of ID m3/h 460/440/420/400/ 380/360/340…
-
SDV6 WALL-MOUNTED
MODEL Capacity cooling/heating Power supply SDV6-H(F)45(S) SDV6-H(F)56(S) SDV6-H71(S) kW 4,5/5,0 5,6/6,3 7,1/8,0 SDV6-H80(S) 8,0/9,0 phase / Hz / V 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 Power input W Air flow of ID m3/h 720/670/620/560/ 510/460/410…
-
MODEL
Capacity cooling/heating Power supply SDV6-DM15 SDV6-DM22 SDV6-DM28 SDV6-DM36 kW 1,5/1,8 2,2/2,6 2,8/3,2 3,6/4,0 SDV6-DM45 4,5/5,0 phase / Hz / V 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 Power input W Air flow of ID m3/h 470/438/407/375/…
-
MODEL
Capacity cooling/heating Power supply SDV6-DM56 SDV6-DM71 SDV6-DM80 SDV6-DM90 kW 5,6/6,3 7,1/8,0 8,0/9,0 9,0/10,0 SDV6-DM112 11,2/12,5 phase / Hz / V 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 Power input W Air flow of ID m3/h 970/904/838/773/…
-
MODEL
Capacity cooling/heating Power supply SDV6-DM125 SDV6-DM140 kW 12,5/14,0 14,0/16,0 SDV6-DM160 16,0/18,0 phase / Hz / V 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 Power input W Air flow of ID m3/h 2105/1971/1837/1703/ 1568/1434/1300 2105/1971/1837/1703/ 1568/1434/1300…
-
таблицы и схемы — в просмотре
-
SDV6-DH56
SDV6-DH71 SDV6-DH80 kW 5,6/6,3 7,1/8,0 8,0/9,0 9,0/10,0 phase / Hz / V 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 MODEL Capacity cooling/heating Power supply Power input Air flow of ID W SH/MH/H/M/L/ ML/SL m3/h 1360/1281/1201/1122/104 1360/1281/1201/1122/104…
-
SDV6-DH112
SDV6-DH125 SDV6-DH140 kW 11,2/12,5 12,5/14,0 14,0/16,0 16,0/17,0 phase / Hz / V 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 MODEL Capacity cooling/heating Power supply SDV6-DH160 W m3/h 2140/2015/1890/1766/ 1641/1516/1391 2150/2025/1899/1774/ 1649/1523/1398…
-
MODEL
Capacity cooling/heating Power supply Power input Air flow of ID SDV6-DH200 SDV6-DH224 SDV6-DH252 kW 20,0/22,5 22,4/25,0 25,2/26,0 28,0/31,5 phase / Hz / V 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 W SH/MH/H/M/L/ ML/SL m3/h SDV6-DH280 4700/4387/4073/3760/344…
-
MODEL
Capacity cooling/heating kW Power supply SDV6-DH335 SDV6-DH400 SDV6-DH450 33,5/38,0 40,0/45,0 45,0/50,0 56,0/63,0 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 phase / Hz / V Power input SDV6-DH560 W 810 1850 1850 2030 m3/h 4700/4387/4073/3760/344 7/3133/2820 7500/7000/6500/…
-
2 Dimensions
-
SDV6-DH200
-
/ SDV6-DH450
-
SDV6 FRESH AIR DUCT
MODEL Capacity cooling 1) / heating 2) Power supply SDV6-DF90 SDV6-DF140 kW 9,0/8,1 14,0/12,5 SDV6-DF160 16,0/14,0 phase / Hz / V 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 Power input W Air flow of ID m3/h 690/633/575/518/ 460/403/345 1100/1008/917/825/ 733/642/550 1230/1128/1025/923/…
-
SDV6 FRESH AIR DUCT
1060 850 850 1060 1060 1060 1095 1095 1095 I (liquid side) Φ25 (Outer External threadside) diameter) I (liquid side) I (liquid Φ25 (Outer Φ25 (Outer I (liquid side) Φ25 (Outer of connector External External thread thread diameter)diameter) External thread diameter) of connector of connector of…
-
SDV6 FLOOR/CEILING
MODEL Capacity cooling/heating Power supply SDV6-F36 SDV6-F45 SDV6-F56 SDV6-F71 kW 3,6/4,0 4,5/5,0 5,6/6,3 7,1/8,0 SDV6-F80 8,0/9,0 phase / Hz / V 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 Power input W Air flow of ID m3/h 564/539/514/492/…
-
SDV6 FLOOR/CEILING
MODEL Capacity cooling/heating Power supply SDV6-F90 SDV6-F100 SDV6-F112 SDV6-F125 kW 9,0/10,0 10,0/11,2 11,2/12,5 12,5/14,0 SDV6-F140 14,0/16,0 phase / Hz / V 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 Power input W Air flow of ID m3/h…
-
AHU KIT
COMPATIBLE WITH OD SDV5, SDV5-3P, SDV6 R410A, SDV6 R32 MODEL Capacity Power supply SAHK-00 SAHK-01 SAHK-02 SAHK-03 kW 1,8-9 9-20 20-36 36-56 SAHK-04 56-168 phase / Hz / V 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 Net dimensions wxdxh mm…
-
Wiring signal wires Terminal block for signal wires Controller selection ● SW4-1 is 0: return air temperature control (factory default) ● SW4-1 is 1: outlet air temperature control ● SW4-2 indicates high bit (ON indicates + 16) ● SW4-3 and SW4-4 are 00: factory controller mode (factory default) ●…
-
EXTERNAL CONTROL OF AHU KIT
The definition of signal between the third party controller and AHU control box Signals from the third party controller to AHU control box Controller type Temperature control type Factory supplied Return air temperature control Cool, Dry, Heat, Fan Supported running mode controller Supply air…
-
ANALOG VOLTAGE CONTROL
Based on supply air temperature TA Third party controller - outlet air temperature control setting Normal Voltage Range Cooling Set Temperature (⁰C) Heating Set Temperature (⁰C) 0.75 Non settable Non settable 1.15 10 10 1.25 1.55 11 11 1.8 1.65 1.95 12 12 2.2 2.05 2.35 13 13 2.6 2.45 2.75 2.85 3.15…
-
MODEL
Horse power (HP) Power SODH-200AI SODH-224AI SODH-280AI - SODH-335AI 12 phase / Hz / V 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 Cooling capacity kW 20 22,4 28 33,5 Cooling input power kW 5,28 6,77 12,02 15,30 EER - 3,79 3,31 2,33 2,19 Heating capacity kW 20 22,4 28…
-
SODH-200/224/280/335AI
ALLOWED LENGHT AND DROP HEIGHT OF CONNECTION (See installation manual) Additional refrigerant: Calculate the added refrigerant according to the diameter and the length of the liquid side pipe of the outdoor unit/indoor unit connection. When the outdoor unit connects 1 meter. ADDITIONAL REFRIGERANT…
-
MODEL
Horse power (HP) Power SODH-400AI SODH-450AI - 14 16 SODH-560AI 20 phase / Hz / V 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 3 ~ / 50 / 380-415 Cooling capacity kW Cooling input power kW 15,7 16 22,9 EER - 2,55 2,81 2,45 Heating capacity kW Heating input power kW 11,7 12,2 15,5 COP - 3,42 3,69 3,61 SEER…
-
SODH-400AI
SODH-450/500/560AI ALLOWED LENGHT AND DROP HEIGHT OF CONNECTION (See installation manual) Additional refrigerant: Calculate the added refrigerant according to the diameter and the length of the liquid side pipe of the outdoor unit/indoor unit connection. When the outdoor unit connects 1 meter.…
-
MODEL
Capacity cooling/heating Power supply Power input Air flow of ID SIDH-200AI SIDH-224AI SIDH-280AI kW 20,0/22,5 22,4/25,0 28,0/31,5 33,5/38,0 phase / Hz / V 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 W SH/MH/H/M/L/ ML/SL m3/h SIDH-335AI 4700/4387/4073/3760/344…
-
SIDH-400AI
SIDH-450AI kW 40,0/45,0 45,0/50,0 56,0/63,0 phase / Hz / V 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 1 ~ / 50 / 220-240 MODEL Capacity cooling/heating Power supply SIDH-560AI W 1850 1850 2030 m3/h 7500/7000/6500/ 5500/5000/4500 7500/7000/6500/ 5500/5000/4500 8400/7840/7280/6720/ 6160/5600/5040 Sound…
-
SDV6-DH200
-
/ SDV6-DH450DUCT
-
R E M O T E A N D W I R E D C O N T R O L L E R S C O M P AT I B L E W I T H I D S D V 6 A N D S I D H MODEL RM05B SRC-61 SWC-86ED SWC-61 SWC-120G SWC-62 SWC-63 On/Off yes yes yes yes yes yes yes Mode selection yes yes yes yes yes yes yes Temperature setting yes yes yes yes yes yes yes 7-speed fan…
-
MODEL SDV6-CLOUD CCM-180A CCM-270A Max. number of ID Max. number of OD - Max. number of ref. systems Touch screen inch SCC-61 - - 6,2 10,1 10,1 On/Off yes yes yes yes Mode selection yes yes yes yes yes (0,5 steps) yes (0,5 steps) yes (0,5 steps) yes (0,5 steps) 7-speed fan control Temperature…
-
COMMUNICATION WIRING BETWEEN THE INDOOR UNIT AND SDV6 OUTDOOR UNIT
-
P Q communication wiring configuration – IDUs uniform power s
-
COMMUNICATION WIRING BETWEEN THE INDOOR UNIT AND SDV6 OUTDOOR UNIT
SDV6 MODULAR SERIES: CENTRAL CONTROLLER, BMS AND DIGITAL ENERGY METER CONNECTION COMMUNICATION P, Q, E PROTOCOL SDV5 Centralized controller X Y Slave ODU Master ODU E X Y E P Q E H1 H1 H2 Refrigerant system 1# PQ P Q E 3-(n-2)# IDU E IDU 1# P Q E H1 PQ IDU 2# E E IDU n# Resister Slave ODU H2 H1 H2 P…
-
COMMERCIAL AIR CONDITIONING
GENERAL OVERVIEW OF ERROR CODES AND OPERATING STATUS CODES APPLIES TO SDV6 OUTDOOR UNITS 1b01 Electronic expansion valve (EEVA) error A01 Emergency stop 2b01 Electronic expansion valve (EEVB) error AAx No.x Inverter driver board does not match the main control board 3b01 Electronic expansion valve…
-
COMMERCIAL AIR CONDITIONING
GENERAL OVERVIEW OF ERROR CODES AND OPERATING STATUS CODES d17 Air inlet temperature of the indoor unit is too high in cooling mode d81 Alarm for exceeding temperature and humidity range dE1 Sensor control board fault dE2 PM2.5 sensor fault dE3 CO2 sensor fault dE4 Formaldehyde sensor fault dE5…
-
MODEL
SCV-50EB Power supply Heating A7W35 SCV-70EB V/Ph/Hz SCV-100EB SCV-120EB SCV-140EB 220-240/1/50 Capacity W 6500 8400 10000 12200 14100 Rated input W 1226 1663 2128 2490 3000 EER - 5,30 5,05 4,70 4,90 4,70 Capacity W 5600 7100 8200 12300 13000 Rated input W 1333 1797 2158 3417 3714 EER - 4,20 3,95…
-
MODEL
SCV-160EB Power supply Heating A7W35 V/Ph/Hz 220-240/1/50 SCV-120EB-3 SCV-140EB-3 SCV-160EB-3 380-415/ 3/50 Capacity W 16000 12200 14100 16000 Rated input W 3556 2490 3000 3556 EER - 4,50 4,90 4,70 4,50 Capacity W 14500 12300 13000 14500 Rated input W 4462 3417 3714 4462 EER - 3,25 3,60 3,50 3,25…
-
SCV-50/70/100/120/140/160EB/EB-3
-
KOMUNIKAČNÍ ZAPOJENÍ DO KASKÁDY
ELECTRICKÉ SCHÉMA ZAPOJENÍDO KASKÁDY KOMUNIKAČNÍ ZAPOJENÍ MINI CHILLERS SW9 SW9 OFF Slave unit OFF Slave unit ON Master unit ON Master unit X/HAY/HB Please use the shielded wire, and the shield layer must be grounded. X/HAY/HB Please use the shielded wire, and the shield layer must be grounded.…
-
MODEL
SCV-750EB Power supply Cooling1 Heating2 Water side heat exchanger Refrigerant SCV-900EBH SCV-1400EB kW 70 69.7 Input kW 26,8 27,3 27,8 28,3 50,5 EER - 2,61 2,55 2,95 2,90 2,57 SEER - 4,30 4,22 4,50 4,44 4,40 Capacity kW 75 75,4 Input kW 23,7 24,3 28,1 29 44,5 COP - 3,16 3,10 3,2 3,10 3,10 SCOP…
-
MODEL
SCV-1400EBH Power supply Cooling1 Heating2 kW 129,5 164 163 Input kW 51,4 56 57,7 2,82 EER - 2,52 2,93 SEER - 4,32 4,41 4,35 Capacity kW 138,6 180 181,2 Input kW 45,6 57 59,1 COP - 3,04 3,16 3,07 SCOP - 3,73 3,80 3,65 A DC inverter rotary DC inverter rotary DC inverter rotary Type Quantity Air side…
-
SCV-750EB/750EBH
SCV-1800EB/EBH 71
-
A D
-
COOLING OPERATING RANGE
MODULAR CHILLERS SCV-750EB, SCV-900EB, SCV-1400EB, SCV-1800EB SCV-750EBH, SCV900EBH, SCV-1400EBH, SCV-1800EBH ① Normal mode ② Low leaving water temperature mode More information in documentation HEATING OPERATING RANGE SCV-750EB, SCV-750EBH SCV-900EB, SCV900EBH SCV-1400EB, SCV-1400EBH SCV-1800EB…
-
EXPANSION BOLT POSITIONING
MODULAR CHILLERS SCV-750EB/750EBH SCV-1800EB/1800EBH SCV-900EB/900EBH, SCV-1400EB/1400EBH DETAIL OF PIPE CONNECTIONS SCV-750EB/750EBH SCV-900EB/900EBH SCV-1400EB/1400EBH SCV-1800EB/1800EBH Model Pipe connection methods Spec. of water pipe Spec. of screw thread SCV-750EB/EBH Hoop DN50 - SCV-900EB/EBH…
-
FCU COMPACT FOUR-WAY CASSETTE, 2 PIPES
MODEL SF-300C2M SF-400C2M SF-500C2M Power supply V/Ph/Hz Air flow (H/M/L) m³/h 535/429/322 610/477/381 CFM 314/252/189 359/281/224 459/359/290 Capacity (H/M/L) kW 2,98/2,53/2 3,96/3,26/2,76 4,2/3,48/3,01 Cooling 220-240/1/50 781/611/494 Water flow rate m³/h 0,53/0,45/0,35 0,7/0,58/0,51…
-
FCU SF2 FOUR-WAY CASSETTE, 2 PIPES
-
FCU SF2 FOUR-WAY CASSETTE, 2 PIPES
>1000 950 (Panel) Air out >1000 >1000 >1000 840 (Body) 785 (Hook-location) Tubing side 785 (Hook-location) (Unit: mm) 840 (Body) 950 (Panel) Outlet E Panel Outlet D Inlet Panel Ground 880mm (ceiling hole) Water pipe joint Ground B F E D C A Outlet 880mm (ceiling hole) B >330 4000~2500(mm) Ceiling…
-
FCU COMPACT FOUR-WAY CASSETTE, 4 PIPES
MODEL SF-300C4M SF-400C4M SF-500C4M Power supply V/Ph/Hz Air flow (H/M/L) m³/h 493/395/295 669/523/415 CFM 290/232/173 393/307/244 395/309/250 Capacity (H/M/L) kW 2,16/1,86/1,49 2,78/2,38/2,05 2,77/2,38/2,07 Water flow rate m³/h 0,42/0,37/0,3 0,53/0,46/0,4 0,56/0,49/0,43 Water pressure drop kPa…
-
FCU SF2 FOUR-WAY CASSETTE, 4 PIPES
-
FCU SF2 FOUR-WAY CASSETTE, 4 PIPES
>1000 950 (Panel) Air out >1000 >1000 >1000 840 (Body) 785 (Hook-location) Tubing side 785 (Hook-location) (Unit: mm) 840 (Body) 950 (Panel) Outlet E Panel Outlet D Inlet Panel Ground 880mm (ceiling hole) Water pipe joint Ground B F E D C A Outlet 880mm (ceiling hole) B >330 4000~2500(mm) Ceiling…
-
FCU WALL-MOUNTED
MODEL SF-250HM2 SF-400HM2 SF-600HM2 Power supply V/Ph/Hz Air flow (H/M/L) m³/h 492/454/400 825/689/590 CFM 289/267/235 485/405/347 575/499/421 Capacity (H/M/L) kW 2,7/2,59/2,39 3,81/3,3/2,88 4,87/4,26/3,79 Water flow rate m³/h 0,48/0,46/0,42 0,67/0,57/0,51 0,85/0,72/0,65 Water pressure drop kPa…
-
таблицы и схемы — в просмотре
-
SF2-200D3(T)
MODEL SF2-300D3(T) V/Ph/Hz Air flow (H/M/L) m3/h 377/301/226 542/424/305 CFM 222/177/133 319/249/179 Standard external static pressure Cooling Heating Fan motor Fan Coil SF2-500D3(T) SF2-600D3(T) 735/602/446 789/635/475 1042/815/576 432/354/262 464/374/279 613/479/339 12Pa (default); 30/50Pa can be…
-
MODEL
-
B (Air return port)
Intlet Outlet Air exhaust valve Condensation water draining port 4-10*16 Hoisting hole 85
-
FCU DUCT 4 PIPES
-
таблицы и схемы — в просмотре
-
FCU FLOOR CEILING 2 PIPES
-
таблицы и схемы — в просмотре
-
GENERAL All dimensions on pictures are in mimimeters (mm) in this catalogue. CONDITIONS UNDER WHICH HAS BEEN PERFORMED MEASUREMENTS OF TECHNICAL PARAMETERS: OUTDOOR UNITS SDV6, SDV5 and SODH 1) Capacities are based on the following conditions: Cooling: Indoor temperature 27°C DB / 19°C WB; Outdoor…
-
AIR CONDITIONING
sinclair-world.com | sinclair-solutions.com
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.