60 Hz
-
CONTENTS
CEA-CEA(N) Series Specifications List of Models and Table of Materials CEA-CEA(N) Series Mechanical Seal CEA-CEA(N) Series Hydraulic Performance Table and Electrical Data CEA-CEA(N) Series Hydraulic Performance Range CEA-CEA(N) Series at 60 Hz Dimensions and Weights CEA-CEA(N) Series CA-CA(N) Series…
-
SingleImpeller
Centrifugal Electric Pumps CEA-CEA(N) 60 Hz Series MARKET SECTORS CIVIL, AGRICULTURAL, INDUSTRIAL. APPLICA TIONS APPLICATIONS Version made of AISI 304 • Handling of chemically and mechanically nonaggressive water and liquids (*). • Water supply. • Irrigation. • Water circulation (cold, hot…
-
IDENTIFICA
TION CODE IDENTIFICATION CEA M 120 6 / 5 N /_ - V FPM VERSION NULL OR LETTER ASSIGNED BY THE MANUFACTURER VERSION MADE OF AISI 316 IMPELLER SIZE 6 = 60 Hz NULL = 50 Hz FLOW RATE IN l/min M = SINGLE-PHASE NULL = THREE-PHASE SERIES NAME EXAMPLE : CEAM 1206/5-V CEA series electric pump, single-phase…
-
LIST OF MODELS AND T
ABLE OF MA TERIALS TABLE MATERIALS DENOMINAZIONE MODEL SERIE CEA VERSIONS CEA706/3 CEA706/4 CEA706/5 CEA1206/1 CEA1206/2 CEA1206/3 CEA1206/4 CEA1206/5 CEA2106/0 CEA2106/1 CEA2106/2 CEA2106/3 CEA2106/4 CEA3706/0 CEA3706/0A CEA3706/1 CEA3706/2 CEA3706/3 cea-ceaN-2p60-en_b_mo MATERIALI…
-
CEA-CEA(N) MECHANICAL SEAL, ACCORDING TO EN 12756
-
TABELLA DI PRESTAZIONI IDRAULICHE SERIE CEA 2 poli 60 Hz
-
MOTORS FOR CEA-CEA(N) SERIES
-
AVAILABLE V
-
ULIC PERFORMANCE RANGE A
-
CEA706 SERIES
OPERA TING CHARACTERISTIC S A T 60 Hz, 2 POLES OPERATING CHARACTERISTICS AT These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec. 13
-
CEA1206 SERIES
OPERA TING CHARACTERISTIC S A T 60 Hz, 2 POLES OPERATING CHARACTERISTICS AT These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec. 14
-
CEA2106 SERIES
OPERA TING CHARACTERISTIC S A T 60 Hz, 2 POLES OPERATING CHARACTERISTICS AT These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec. 15
-
CEA3706 SERIES
OPERA TING CHARACTERISTIC S A T 60 Hz, 2 POLES OPERATING CHARACTERISTICS AT These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec. 16
-
DIMENSIONS AND WEIGHTS A
-
TwinImpeller
Centrifugal Electric Pumps CA-CA(N) 60 Hz Series MARKET SECTORS CIVIL, AGRICULTURAL, INDUSTRIAL. APPLICA TIONS APPLICATIONS • Handling of chemically and mechanically nonaggressive water and liquids (*). • Water supply. • Irrigation. • Water circulation (cold, hot, refrigerated). * For moderately…
-
IDENTIFICA
TION CODE IDENTIFICATION CA M 120 6 / 33 N /_ - V FPM VERSION NULL OR LETTER ASSIGNED BY THE MANUFACTURER VERSION MADE OF AISI 316 IMPELLER SIZE 6 = 60 Hz NULL = 50 Hz FLOW RATE IN l/min M = SINGLE-PHASE NULL = THREE-PHASE SERIES NAME EXAMPLE : CAM 1206/33-V CA series electric pump, single-phase…
-
LIST OF MODELS AND T
ABLE OF MA TERIALS TABLE MATERIALS DENOMINAZIONE MODEL SERIE CA VERSIONS CA706/33 CA1206/33 CA2006/33 ca-caN-2p60-en_a_mo MATERIALI CA70-CA120-CA200 CA SERIES T ABLE OF MA TERIALS TABLE MATERIALS REF. PART REFERENCE STANDARDS MATERIAL N. EUROPE Suction flange Pump body Impeller Diffuser cover…
-
PRESTAZIONI IDRAULICHE SERIE CA 2 poli 60 Hz
-
s = Standard voltage
-
ULIC PERFORMANCE RANGE A
-
CA706 SERIES
OPERA TING CHARACTERISTIC S A T 60 Hz, 2 POLES OPERATING CHARACTERISTICS AT These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec. 27
-
CA1206 SERIES
OPERA TING CHARACTERISTIC S A T 60 Hz, 2 POLES OPERATING CHARACTERISTICS AT These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec. 28
-
CA2006 SERIES
OPERA TING CHARACTERISTIC S A T 60 Hz, 2 POLES OPERATING CHARACTERISTICS AT These performances are valid for liquids with density ρ = 1.0 Kg/dm3 and kinematic viscosity ν = 1 mm2/sec. 29
-
DIMENSIONS AND WEIGHTS A
-
TECHNICAL
APPENDIX 31
-
TYPICAL APPLICA
TIONS CEA AND CA SERIES ELECTRIC PUMPS APPLICATIONS Water Purification: Filtration De-ionized water Water treatment Commercial and residential pools Waste Management: Waste treatment Pollution control Plastic Industry: Temperature Regulators Extrusion machines Manufacture of polymers Machine Tool…
-
TECHNICAL APPENDIX carbon - ceramic standard product configuration code configuration code configuration code standard product carbon - ceramic standar product carbon - ceramic not recommended configuration code configuration code carbon - ceramic standard product carbon - ceramic carbon - ceramic…
-
TECHNICAL APPENDIX
34 1 = COMPATIBILITA' BUONA 2 = COMPATIBILITA' MEDIOCRE 3 = NON COMPATIBILE 1 = GOOD COMPATIBILITY 2 = POOR COMPATIBILITY 3 = NO COMPATIBILITY (X) - Richiesto battente positivo / Positive suction head required configuration code configuration code configuration code configuration code configuration…
-
WATER REQUIREMENTS IN CIVIL USERS
Determination of the water requirement depends on the type of users and contemporaneity factor. The calculation may be subject to regulations, standards or customs that may vary from country to country. The calculation method shown below is an example based on practical experience, designed to…
-
TABLE OF WATER REQUIREMENTS IN CIVIL USERS
WITH FLUSH TANK WC NUMBER OF APARTMENTS 1 WITH CONTROLLED FLUSHING SYSTEM WC 1056 1114 FLOW RATE (l/min) For seaside resorts, a flow rate increased by at least 20% must be considered. TECHNICAL APPENDIX 36 G-at-fi_a_th
-
WATER REQUIREMENTS FOR COMMUNITY BUILDINGS
The requirements of buildings intended for specific uses, such as offices, residential units, hotels, department stores, nursing homes and so on, are different from those of condominiums, and both their global daily water consumption and the maximum contemporaneity flow rate are usually greater. The…
-
NPSH
The maximum possible suction head for installation depends on the value of the atmospheric pressure (i.e. the elevation above sea level at which the pump is installed) and the temperature of the liquid. The minimum operating values that can be reached at the pump suction end are limited by the onset…
-
TECHNICAL APPENDIX VAPOUR PRESSURE PS VAPOUR
-
FLOW RESISTANCE
TABLE OF FLOW RESISTANCE IN BENDS, VALVES AND GATES The flow resistance is calculated using the equivalent pipeline length method according to the table below: DN ACCESSORY TYPE 45° bend 90° bend 90° smooth bend Union tee or cross Gate Non return valve 0,2 0,4 0,4 1,1 1,1 0,2 0,6 0,4 1,3 1,5 0,4 0,9…
-
V
OL UMETRIC CAP ACITY OLUMETRIC CAPACITY VOLUMETRIC CAPACITY Litres Cubic metres Cubic feet Cubic feet Imp. gal. US gal. per minute per hour per hour per minute per minute per minute l/min m3/h ft3/h ft3/min 0,0353 0,5886 0,0167 1,0000 0,1605 0,1337 Imp. gal/min 0,2200 3,6662 0,1038 6,2288 1,0000…
-
FURTHER PRODUCT SELECTION AND DOCUMENT
ATION DOCUMENTA Xylect Xylect is pump solution selection software with an extensive online database of product information across the entire Lowara, and Vogel range of pumps and related products, with multiple search options and helpful project management facilities. The system holds up-to-date…
-