Каталог продукции ISAN 2019 - Напольные и настенные конвекторы ECOLITE
Загружаем документ…
Текст каталога
-
Lamellar Heat-Exchanger
Convector Heaters
-
About the Company
The ISAN trademark represents a traditional Czech manufacturer of heating units with a history that goes back more than 60 years. ISAN Radiátory s.r.o. has been involved in the development and manufacture of convectors for over 12 years. First-rate technological procedures and the progressive…
-
ECOLITE – Basic Information
Application Convector heaters are generally installed in residential and administrative buildings, oice settings and entrance halls, as well as storage facilities, changing rooms and other workplace areas. Individual models allow for installation in front of large glass walls or free-standing or…
-
BMS
Convector heaters equipped with EC fan technology in combination with a modern digital thermostat can easily be incorporated into building management systems (BMS). Communication with the superior system is either direct or via a thermostat with an output for KNX protocol communication. For other…
-
Heater Type Overview
Self-standing convector heaters 24 ECO& AFE VOLTAGE SAFE LZK TZK TZT LZT NATURAL CONVECTION HEATER FAN OPERATED CONVECTOR HEATER LZK - model CUBE page 12 TZK - model ROUND page 30 LZT - model CUBE page 20 TZT - model ROUND page 38 Wall-mounted convector heaters 24 ECO& AFE VOLTAGE SAFE TSK LSK TST…
-
Design Options
Grilles The grille design is specied upon ordering. The grille is a xed and integral part of the convector heater; it may not be removed to tamper with inner components of the heater. Each grille is carefully selected to match the interior as well as to achieve its purpose in dierent environments.…
-
Convector heater accessories
LZK, LSK, TZK, TSK Thermostatic heads They regulate the ow of heating medium in convectors with natural convection. They proportionally maintain the desired room temperature. It is possible to use alternative thermostat heads with the connection thread M30x1,5. SENSITIVE CHROME Thermostatic head…
-
Thermostatic valve
Z-LE001 AXIAL THERMOSTATIC VALVE Horiozontal axial valve, heating medium ow regulation in the system, installation on the heat exchanger’s inlet pipe Parameters Heating water, water quality to VDI2035 Operating temperature max. 130 °C (262°F) Operating pressure PN10 Dierential pressure max. 2 bar…
-
Fan convector heaters accessories
LZT, LST, TZT, TST Controls and a power supply need to be added to convectors to secure their correct function. The temperature in the room is assessed by a room thermostat (RTD201 , RTM201), which controls the fan’s revs and the ow of heating medium through the heat exchanger. The ow is controlled…
-
Electrothermal actuator
Z-TS24 ELECTROTHERMAL ACTUATOR 24 V DC Opened/closed function (without voltage closed). Parameters Input voltage: 24 V DC Power consumption: at switch-on 6 VA, input at operation: 2,5 W Opening/closing time: 270 s Degree of protection: IP54 cover of the casing Connection to valve: M30×1,5 mm Total…
-
ECOLITE CUBE
Self-Standing and Wall-Mounted Convector Heaters A designer element of contemporary buildings with smooth surfaces, grille and stand variations and colour combinations to match your interior decor. LZK 0200 0198 1200 10 ECOLITE | Lamellar heat-exchanger convector heaters | www.isan.cz
-
LZT 0350 0138 1000
LST 0500 0122 1000 LSK 0400 0122 0800 ECOLITE | Lamellar heat-exchanger convector heaters | www.isan.cz 11
-
LZK Self-standing convector heaters
Convector heaters with lamellar heat-exchangers are popular for their simple design. They nd their application especially at locations where larger glass surfaces, such as French windows, shop windows or walls exposed to cold air, need to be thermally screened. However, they also provide an elegant…
-
Exhaust grille
Cover convector Details of accessories on the page 6 Axial thermostatic valve Z-LE001 Thermostatic head (not supplied with the heater) Stands convector Al-Cu heat exchanger, 50 mm connection spacing, 2 x G1/2“ inner thread Grilles Order grilles and stands in that vary from the cover tip colours to…
-
LZK - Self-standing convectors heating output
-
LZK - Heating output recalculation for another temperature gradient
To obtain the heating output for a dierent temperature gradient multiply heating output value at 75/65/20 ° C by the below mentioned factor f. Example Heating output of the convector LZK 0200 0138 2000 for temperature gradient 70/55°C 1. Output 75/65/20 ° C = 1 391 W 2. Factor from the table for…
-
LSK Wall-mounted convector heaters
Wall-mounted convector heaters with smooth front covers will provide an aesthetic complement to your interior. Convection heating is especially suitable for settings where prompt response to temperature uctuations and low surface temperature are required. Each heater can be tted with a variety of…
-
Exhaust grille
Cover convector Details of accessories on the page 6 Axial thermostatic valve Z-LE001 Thermostatic head (not supplied with the heater) Al-Cu heat exchanger, 50 mm connection spacing, 2 x G1/2“ inner thread Grilles Order grilles and stands in that vary from the cover tip colours to brighten up your…
-
LSK - Wall-mounted convectors heating output
-
таблицы и схемы — в просмотре
-
LZT Fan-operated self-standing convector heaters
Convector heaters equipped with a 24V DC fan are suitable for low-temperature heating systems. Their heat output is suicient even when operated in combination with condensing boilers or heat pumps. A wall-mounted thermostat continuously controls the speed of the fan, while the convector heater…
-
Exhaust grille
Cover convector Electrothermal actuator 24 V DC (not supplied with the heater) connection of electric cabling Corner thermostatic valve Z-TE001 Details of accessories on the page 8 Tangential fan 24 V DC EC with continuous speed control, bottom safety grille Stands convector Al-Cu heat exchanger, 50…
-
LZT - Fan-operated self-standing convectors heating output
Width 138 mm 75/65/20°C Length [mm] 700 1000 1200 1400 1600 1800 2000 2200 2400 2600 Speed [-] / Heating output [W] 55/45/20°C 4 max Length [mm] 700 1000 1200 1400 1600 1800 2000 2200 2400 2600 Speed [-] / Heating output [W] max Exponent n = 1,065 Width 198 mm 75/65/20°C Length [mm] 700 1000 1200…
-
LZT - Heating output recalculation for another temperature gradient
-
LST Fan-operated wall-mounted convector heaters
Fan-operated wall-mounted heaters are distinctive for their compact appearance. The electrothermal actuator for heating uid ow control, as well as the water connection piping, is concealed inside the heater unit. The installed 24V DC fan eectively balances out extreme temperature variations…
-
Exhaust grille
Cover convector Connection of electric cabling Electrothermal actuator 24 V DC (not supplied with the heater) Details of accessories on the page 8 Corner thermostatic valve Z-TE001 Tangential fan 24 V DC EC with continuous speed control Al-Cu heat exchanger, 50 mm connection spacing, 2 x G1/2“ inner…
-
LST - Fan-operated wall-mounted convectors heating output
Height 500 mm / Width 122 mm 75/65/20°C Length [mm] 700 1000 1200 1400 1600 Speed [-] / Heating output [W] 55/45/20°C 4 max Length [mm] 700 1000 1200 1400 1600 Speed [-] / Heating output [W] max Exponent n = 1,079 Height 500 mm / Width 182 mm 75/65/20°C Length [mm] 700 1000 1200 1400 1600 Speed [-]…
-
LST - Heating output recalculation for another temperature gradient
To obtain the heating output for a dierent temperature gradient multiply heating output value at 75/65/20 ° C by the below mentioned factor f. Recalculation to other temperature gradients Example Heating output of the convector LST 0500 0182 1400 for temperature gradient 70/55°C 1. Output 75/65/20 °…
-
ECOLITE ROUND
Self-standing and Wall-mounted Convector Heaters New series of convectors with rounded edges. Their elegant look can be used in both modern and historic buildings but also where itsrounded shapeprovides a prevention of injury: nurseries, schools and health facilities. TZK 0200 0198 1200 28 ECOLITE |…
-
TZK 0200 0198 1200
TST 0500 0122 1000 TZT 0350 0138 1000 ECOLITE | Lamellar heat-exchanger convector heaters | www.isan.cz 29
-
TZK Self-standing convector heaters
Convector heaters with lamellar heat-exchangers are popular for their simple design. The rounding not only enhances the aesthetic appearance of the units, but it also improves safety in exposed areas. They are oen installed in schools, preschools, and health and social facilities where injury…
-
Exhaust grille
Cover convector Stands convector Details of accessories on the page 6 Axial thermostatic valve Z-LE001 Thermostatic head (not supplied with the heater) heat exchanger support Al-Cu heat exchanger, 50 mm connection spacing, 2 x G1/2“ inner thread Grilles Order grilles and stands in that vary from the…
-
TZK - Self-standing convectors heating output
-
TZK - Heating output recalculation for another temperature gradient
To obtain the heating output for a dierent temperature gradient multiply heating output value at 75/65/20 ° C by the below mentioned factor f. Example Heating output of the convector TZK 0200 0138 2000 for temperature gradient 70/55°C 1. Output 75/65/20 ° C = 1 391 W 2. Factor from the table for…
-
TSK Wall-mounted convector heaters
Wall-mounted convector heaters with smooth front panelling and rounded edges will prove an excellent addition to both modern and historic interiors as well as to environments with increased safety requirements. Convection heating is especially suitable for settings where prompt response to…
-
Exhaust grille
Cover convector Details of accessories on the page 6 Axial thermostatic valve Z-LE001 Thermostatic head (not supplied with the heater) Al-Cu heat exchanger, 50 mm connection spacing, 2 x G1/2“ inner thread Grilles Order grilles and stands in that vary from the cover tip colours to brighten up your…
-
TSK - Wall-mounted convectors heating output
-
таблицы и схемы — в просмотре
-
TZT Fan-operated self-standing convector heaters
Convector heaters equipped with a fan are suitable for low-temperature heating systems. Their heat output is suicient even with low inlet temperatures of the heating uid supplied by heat pumps. The rounding not only enhances the aesthetic appearance of the units, but it also improves safety in…
-
Exhaust grille
Cover convector electrothermal actuator 24 V DC (not supplied with the heater) Corner thermostatic valve Z-TE001 Details of accessories on the page 8 Tangential fan 24 V DC EC with continuous speed control, bottom safety grille Stands convector Al-Cu heat exchanger, 50 mm connection spacing, 2 x…
-
TZT - Fan-operated self-standing convectors heating output
Width 138 mm 75/65/20°C Length [mm] 700 1000 1200 1400 1600 1800 2000 2200 2400 2600 Speed [-] / Heating output [W] 55/45/20°C 4 max Length [mm] 700 1000 1200 1400 1600 1800 2000 2200 2400 2600 Speed [-] / Heating output [W] max Exponent n = 1,065 Width 198 mm 75/65/20°C Length [mm] 700 1000 1200…
-
TZT - Heating output recalculation for another temperature gradient
-
TST Fan-operated wall-mounted convector heaters
Fan-operated wall-mounted heaters are distinctive for their compact appearance. The rounded edges will perfectly complement both modern and historic interiors as well as environments with increased safety requirements. The electrothermal actuator for heating uid ow control, as well as the water…
-
Exhaust grille
Cover convector Connection of electric cabling Electrothermal actuator 24 V DC (not supplied with the heater) Details of accessories on the page 8 Corner thermostatic valve Z-TE001 Tangential fan 24 V DC EC with continuous speed control Al-Cu heat exchanger, 50 mm connection spacing, 2 x G1/2“ inner…
-
TST - Fan-operated wall-mounted convectors heating output
Height 500 mm / Width 122 mm 75/65/20°C Length [mm] 700 1000 1200 1400 1600 1800 2000 2200 2400 2600 Speed [-] / Heating output [W] 55/45/20°C 4 max Length [mm] 700 1000 1200 1400 1600 1800 2000 2200 2400 2600 Speed [-] / Heating output [W] max Exponent n = 1,079 Height 500 mm / Width 182 mm…
-
TST - Heating output recalculation for another temperature gradient
-
LBK Convector Bench
Self-standing convector with wooden bench. This unit allows you to sit down comfortably or put your belongings down. It is ideal solution for public areas where the space in front of window is used both for heating and for people to rest i.e. waiting rooms, airports etc. Convector bench is also…
-
Wooden board
Board support Exhaust grille Details of accessories on the page 6 Cover convector Axial thermostatic valve Z-LE001 Thermostatic head (not supplied with the heater) Stands convector Al-Cu heat exchanger, 50 mm connection spacing, 2 x G1/2“ inner thread Grilles tip Grille R - rectangular holes Grille…
-
Atypical convector heaters
Design modications of wall-mounted convector heaters The design of convector heaters can be modied to meet your requirements. You can select from dierent grille setting options in the cover or models with the casing extended to the oor. Below are presented some basic modications; for more options…
-
Atypical convector heaters
Design modications of wall-mounted convector heaters CASING EXTENDED TO THE FLOOR LGK, TGK A compact-looking unit with its casing extended to the oor. The heater seems to be standing directly on the oor. All internal components and connection piping are safely covered. The casing can be removed for…
-
Pressure loss for self-standing models
-
LZT, TZT width 138 mm / height 350 mm
-
Pressure loss for wall-mounted models
-
LSK, TSK width 182 mm / height 165, 200, 300, 400, 500, 600 mm
-
Electrical diagram
SCHEME 1 - basic connection Note The voltage must not drop below 22 V DC, it is necessary to size the cross section of conductors correctly according to the calculation SW. If more than 10 electrothermal actuators are used it is necessary to use the switching relay (see SCHEME 2). If the capacity of…
-
Electrical diagram
SCHEME 3 - connection with more supplies Note The voltage must not drop below 22 V DC, it is necessary to size the cross section of conductors correctly according to the calculation SW. If more than 10 electrothermal actuators are used it is necessary to use the switching relay (see SCHEME 2). All…
-
Acoustics
When planning fan-operated convectors fan for residential rooms it is necessary to take into account the acoustic characteristics of the convector and the environment in which it will be used. It is necessary to design a convector complying with the applicable standard, which denes acoustic limits…
-
Orientation colour card
colour series RAL 9016 colour series S09 colour series RAL 9001 shade snow-white shade snow-white shade ivory nish - nish texture nish - extra charge - extra charge - extra charge - order code 01 order code 68 order code 04 colour series S31 colour series RAL 9018 colour series S08 shade champagne…
-
ECOLITE - coding for convector heaters
with lamellar heat exchangers Code description ECOLITE wall-mounted convector heater; square LSK model; HxWxL 300x198x1,600mm; steel casing – white spray paint RAL 9016; grille: rectangular with cut slots - colour matching the coating; valve-equipped; right-side connection; oor-mounted – block…
-
2 3 MODEL TYPE OF CONSTRUCTION CONVECTOR TYPE L ECOLITE CUBE, convector heaters with a lamellar heat exchanger T ECOLITE ROUND, rounded corners, convector heaters with a lamellar heat exchanger Z Self-standing convector heater, standard B Self-standing convector heater with wooden board S…
-
Notes
Contacts 60 ECOLITE | Lamellar heat-exchanger convector heaters | www.isan.cz
-
ECOLITE | Lamellar heat-exchanger convector heaters | www.isan.cz
-
E0901-EN / We reserve the right to changes and misprints
ISAN Radiátory s.r.o | Poíí 26, 678 01 Blansko, CZ CZ | Tel.: +420 | Fax: +420 | obchod@isan.cz | www.isan.cz SK | Tel.: +421 | obchod@isan.sk | www.isan.sk Export | Tel.: +420 | Fax: +420 | sales@isan.cz | www.isan.cz
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.