Технический каталог Ebara 2022 - Насосные станции GP-GPE MATRIX
Технический каталог Ebara 2022 - Насосные станции GP-GPE MATRIX 50Hz
Загружаем документ…
Текст каталога
-
GP - GPE MATRIX
Data Book 50Hz
-
CONTENTS
Page INDEX 2 DEFINITION AND USE OF PRESSURISATION UNITS 101 TYPICAL APPLICATIONS 101 OPERATING CONDITIONS 101 TESTS AND TRIALS 101 MECHANICAL AND HYDRAULIC TESTS 101 ELECTRICAL TESTS 102 PRINCIPLE OF OPERATION OF GP PRESSURISATION UNITS 102 Principle of Operation of GPE Pressurisation UNITS with…
-
CONTENTS
2GP(.) MATRIX 5-7T/1.5 413 2GP(.) MATRIX 5-8T/2.2 414 2GP(.) MATRIX 5-9T/2.2 415 2GP(.) MATRIX 10-3T/1.3 416 2GP(.) MATRIX 10-4T/1.5 417 2GP(.) MATRIX 10-5T/2.2 418 2GP(.) MATRIX 10-6T/2.2 419 2GP(.) MATRIX 18-3T/2.2 420 2GP(.) MATRIX 18-4T/3 421 2GP(.) MATRIX 18-5T/4 422 2GP(.) MATRIX 18-6T/4 423…
-
INTRODUCTION
1 In situations in which a municipal water mains is lacking or insufficient for the proper operation of the services, one must install a pressurization unit to provide acceptable pressure and flow rates to even in the most unfavourable services. Pressurisation units are used wherever there is a need…
-
INTRODUCTION
1 • Earthing system continuity • Applied voltage (dielectric rigidity) • Insulation resistance PRINCIPLE OF OPERATION OF GP PRESSURISATION UNITS When water is demanded, it is first drawn from the autoclave tank (if present). This demand for water, with the pumps stopped, lowers the pressure until…
-
INTRODUCTION
Principle of Operation of GPE Pressurisation UNITS with an MFC control panel MFC multiple pump control panels power each pump with an INVERTER to modulate system performance in relation to the reference signal. MFC controllers differ from EFC controller from the point of view of their construction…
-
INTRODUCTION
1 INTRODUCTION Fig. 1 - TWO PUMP UNIT WITH CONSTANT PRESSURE REGULATION GP PRESSURISATION UNIT WATER CIRCUIT DIAGRAM 104 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
INTRODUCTION
1 INTRODUCTION GPE PRESSURISATION UNIT WATER CIRCUIT DIAGRAM 105 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
INTRODUCTION
1 TYPE KEY 2 GPE space MATRIX 5-4T/0,9 M space EFC Control type Null = Fixed speed EP-E up to 7,5kW fixed speed EP from 11kW and above EFC = Single Inverter SP-EFC MFC = Multi Inverter SP-EFC ESPM = E-SPD+ MT (Inlet voltage 230V single phase) ESPT = E-SPD+ TT (Inlet voltage 400V three phase) Phase…
-
TECHNICAL DATA
2 PRODUCT SPECIFICATIONS BOOSTER SET MATRIX Version Nominal flow rate ( m3/h ) Operating range Hydraulic components Single pump 2GP(E) Maximum working pressure 10 bar Liquid temperature range 0 ÷ +80°C [1] Ambient operating temperature (no higher than 1000 m above sea level) 0 ÷ +40°C Frame Omega…
-
TECHNICAL DATA
2 ELECTRIC PANEL BOOSTER SET MATRIX Version Operating range Single pump 2GP ( E ) EP-E fixed speed ( only for GP ) ● ● ● ● SP EFC/MFC variable speed ( only for GPE ) ○ ○ ○ ○ ● ● ● ○ ● ● ● ○ Nominal flow rate ( m3/h ) Principal Electric panel Control panel E-SPD+ [1] ESPDM singlephase supply inverter…
-
TECHNICAL DATA
2 TECHNICAL PUMP DATA Version Operating range Liquid handled Maximum working pressure 1 MPa ( 10 bar ) Liquid temperature range -15°C to +85°C Liquid type TECHNICAL DATA PUMP MATRIX 18 Water, moderate aggressive solutions, glycol solutions, moderate viscous fluids Casing Impeller EN 1.4301 (AISI…
-
TECHNICAL DATA
2 TECHNICAL MOTOR DATA Frequency Phase Power source TECHNICAL DATA MOTOR MATRIX 50 Hz Single-phase Rotation speed Three-phase 2850 min-1 0.65 ÷ 2.2 kW 0.65 ÷ 4.0 kW 0.9 ÷ 3.0 HP 0.9 ÷ 5.5 HP 230 ± 10% V 230/400 ± 10% Power rating Voltage Type Efficiency level Type Electric - TEFC - N° of poles IE3…
-
PERFORMANCE RANGE
3 PERFORMANCE RANGE RESEAU BOOSTER SET 2GP(.) MATRIX PERFORMANCE RANGE GP-GPE 301 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
CURVE SPECIFICATION
4 CURVE SPECIFICATION 2GP(.) Tolerances according to ISO 9906:2012 – Grade 3B. The curves refer to effective speed of asynchronous motors at 50 Hz 2 poles Measurements were carried out with clean water at 20°C of temperature and with a kinematic viscosity of = 1 mm2/s (1 cSt). The NPSH curve is an…
-
SELECTION CHART
4 SELECTION CHART 2GP(.) MATRIX SELECTION CHART GP-GPE 402 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
PERFORMANCE CURVE 2GP(.) 2GP(.) MATRIX 3-4T/0.65 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 403 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) MATRIX 3-5T/0.75 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 404 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) MATRIX 3-6T/0.9 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 405 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) MATRIX 3-7T/1.3 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 406 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) MATRIX 3-8T/1.3 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 407 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) MATRIX 3-9T/1.5 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 408 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) MATRIX 5-3T/0.65 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 409 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) MATRIX 5-4T/0.9 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 410 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) MATRIX 5-5T/1.3 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 411 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) MATRIX 5-6T/1.3 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 412 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) MATRIX 5-7T/1.5 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 413 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) MATRIX 5-8T/2.2 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 414 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) MATRIX 5-9T/2.2 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 415 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) MATRIX 10-3T/1.3 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 416 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) MATRIX 10-4T/1.5 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 417 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) MATRIX 10-5T/2.2 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 418 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) MATRIX 10-6T/2.2 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 419 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) MATRIX 18-3T/2.2 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 420 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) MATRIX 18-4T/3 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 421 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) MATRIX 18-5T/4 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 422 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) MATRIX 18-6T/4 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 423 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
CONSTRUCTION
6 2GP CONSTRUCTION CONSTRUCTION EXTERNAL VIEW 2GP MATRIX N° PART NAME Principal pump Electric motor Basement Basement foot Suction manifold Union ball valve Check valve Threaded female cap Nipple for air feeders Discharge manifold Union ball valve Threaded female cap Control panel Control panel…
-
CONSTRUCTION
6 CONSTRUCTION EXTERNAL VIEW 2GPE MATRIX E-SPD+ N° 410-22 PART NAME Principal pump Electric motor Baseplate Baseplate foot Suction manifold Union ball valve Threaded female cap Discharge manifold Union ball valve Check valve Threaded female cap E-SPD+ E-SPD+ adaptor Protection panel Protection panel…
-
DIMENSIONS AND WEIGHT
-
таблицы и схемы — в просмотре
-
DIMENSIONS AND WEIGHT
-
DIMENSIONS AND WEIGHT
7 2GP MATRIX THREE PHASE 2GP THREE PHASE 2GP MATRIX 3-4T/0.65 2GP MATRIX 3-5T/0.75 2GP MATRIX 3-6T/0.9 2GP MATRIX 3-7T/1.3 2GP MATRIX 3-8T/1.3 2GP MATRIX 3-9T/1.5 2GP MATRIX 5-4T/0.9 2GP MATRIX 5-5T/1.3 2GP MATRIX 5-6T/1.3 2GP MATRIX 5-7T/1.5 2GP MATRIX 5-8T/2.2 2GP MATRIX 5-9T/2.2 2GP MATRIX…
-
CONTROL PANEL
8 CONTROL PANEL FIXED SPEED 2EP-E SPECIFICATION Electrical panel (protection and control) for two electropumps. Manual or automatic operation through pressure transmitter. The panel is configured to start the two pumps alternately in stand-by to pressure transmitter. The electrical panel protects…
-
таблицы и схемы — в просмотре
-
CONTROL PANEL
8 CONTROL PANEL VARIABLE SPEED E-SPD+ SPECIFICATION CONTROL PANEL On board electronic device for controlling electropumps, employing inverter technology. Starts and stops the pump and modulates the speed of the motor in relation to the water demand on the system, to maintain the operating pressure…
-
CONTROL PANEL
8 SP (EFC and MFC) SPECIFICATION The control panels SP EFC/MFC series inverters modulate the operation of electropumps in response to control by the pressure transmitter (transducer measuring flow or other external signal 4-20 mA), regulating the speed of the electropumps to keep system demand…
-
таблицы и схемы — в просмотре
-
CONTROL PANEL
-
таблицы и схемы — в просмотре
-
EBARA Corporation
11-1, Haneda Asahi-cho, Ota-ku, Tokyo 144-8510 Japan Tel. +81 3 6275 7598 Fax +81 3 5736 3193 www.ebara.com I contenuti della presente pubblicazione non devono essere considerati impegnativi. EBARA Pumps Europe S.p.A. si riserva il diritto di apportare senza preavviso le modifiche che riterrà più…
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.