Технический каталог Ebara 2022 - Насосные станции GP CDA
Технический каталог Ebara 2022 - Насосные станции GP CDA 50Hz
Загружаем документ…
Текст каталога
-
GP CDA
Data Book 50Hz
-
CONTENTS
Page INDEX 2 DEFINITION AND USE OF PRESSURISATION UNITS 101 TYPICAL APPLICATIONS 101 OPERATING CONDITIONS 101 TESTS AND TRIALS 101 MECHANICAL AND HYDRAULIC TESTS 101 ELECTRICAL TESTS 102 PRINCIPLE OF OPERATION OF GP PRESSURISATION UNITS 102 Principle of Operation of GPE Pressurisation UNITS with…
-
CONTENTS
PACKING 603 CONTROL PANEL FIXED SPEED 801 2EP-E SPECIFICATION 801 CONTROL PANEL VARIABLE SPEED 803 E-SPD+ SPECIFICATION 803 SP (EFC and MFC) SPECIFICATION 804 PROTECTION PANEL SPECIFICATION 807 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice CONTENTS…
-
INTRODUCTION
1 In situations in which a municipal water mains is lacking or insufficient for the proper operation of the services, one must install a pressurization unit to provide acceptable pressure and flow rates to even in the most unfavourable services. Pressurisation units are used wherever there is a need…
-
INTRODUCTION
1 • Earthing system continuity • Applied voltage (dielectric rigidity) • Insulation resistance PRINCIPLE OF OPERATION OF GP PRESSURISATION UNITS When water is demanded, it is first drawn from the autoclave tank (if present). This demand for water, with the pumps stopped, lowers the pressure until…
-
INTRODUCTION
Principle of Operation of GPE Pressurisation UNITS with an MFC control panel MFC multiple pump control panels power each pump with an INVERTER to modulate system performance in relation to the reference signal. MFC controllers differ from EFC controller from the point of view of their construction…
-
INTRODUCTION
1 INTRODUCTION Fig. 1 - TWO PUMP UNIT WITH CONSTANT PRESSURE REGULATION GP PRESSURISATION UNIT WATER CIRCUIT DIAGRAM 104 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
INTRODUCTION
1 INTRODUCTION GPE PRESSURISATION UNIT WATER CIRCUIT DIAGRAM 105 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
INTRODUCTION
1 TYPE KEY 2 GPE space CDA 1.00 M space EFC Control type Null = Fixed speed EP-E up to 7,5kW fixed speed EP from 11kW and above EFC = Single Inverter SP-EFC MFC = Multi Inverter SP-EFC ESPM = E-SPD+ MT (Inlet voltage 230V single phase) ESPT = E-SPD+ TT (Inlet voltage 400V three phase) Phase booster…
-
TECHNICAL DATA
2 PRODUCT SPECIFICATIONS BOOSTER SET CDA Model Nominal flow rate ( m3/h ) Operating range 1.00 1.50 2.00 3.00 4.00 5.50 Single pump 5.4 6.0 6.6 8.4 11.4 12.6 2GP 10.8 12.0 13.2 16.8 22.8 25.2 Maximum working pressure Liquid temperature range 6 bar 10 bar +5÷+80°C [1] +5÷+40°C ( 2GP CDA 1.00 )…
-
TECHNICAL DATA
2 BOOSTER SET CDA Model Operating range Control panel Nominal flow rate ( m3/h ) 1.00 1.50 2.00 3.00 4.00 5.50 Single pump 5.4 6.0 6.6 8.4 11.4 12.6 2GP 10.8 12.0 13.2 16.8 22.8 25.2 Principal Electric panel EP-E fixed speed 202 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make…
-
TECHNICAL DATA
2 PUMP CDA Model Operating range Maximum working pressure 1.00 Key components material 2.00 0.6 Mpa ( 6 bar ) 3.00 4.00 5.50 1.0 Mpa \ ( 10 bar ) +5°C to +90°C +5°C to +40°C ( only CDA 1.00 ) Liquid temperature range Liquid handled 1.50 Liquid type Clean water Casing Cast iron Impeller PPE+PS glass…
-
TECHNICAL DATA
2 TECHNICAL DATA TECHNICAL MOTOR DATA MOTOR CDA Frequency Phase Power source 50 Hz Single-phase Rotation speed Three-phase 2850 min-1 0.75 ÷ 1.5 kW 0.75 ÷ 4.0 kW 1 ÷ 2 HP 1 ÷ 5.5 HP 230 ± 10% V 230/400 ± 10% Power rating Voltage Type Efficiency level Type Electric - TEFC - N° of poles IE3 from 0.75…
-
PERFORMANCE RANGE
3 PERFORMANCE RANGE RESEAU BOOSTER SET 2GP(E) CDA PERFORMANCE RANGE GP-GPE 301 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
CURVE SPECIFICATION
4 CURVE SPECIFICATION 2GP(E) Tolerances according to ISO 9906:2012 – Grade 3B. The curves refer to effective speed of asynchronous motors at 50 Hz 2 poles Measurements were carried out with clean water at 20°C of temperature and with a kinematic viscosity of = 1 mm2/s (1 cSt). The NPSH curve is an…
-
SELECTION CHART
4 SELECTION CHART 2GP(.) CDA SELECTION CHART GP-GPE 402 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
PERFORMANCE CURVE 2GP(.) 2GP(.) CDA 1.00 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 403 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) CDA 1.50 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 404 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) CDA 2.00 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 405 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) CDA 3.00 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 406 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) CDA 4.00 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 407 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
2GP(.) CDA 5.50 PERFORMANCE CURVE GP-GPE Test standard: ISO 9906: 2012 - Grade 3B 408 EBARA Pumps Europe EBARA Pumps Europe reserves the right to make changes without prior notice
-
CONSTRUCTION
6 2GP CONSTRUCTION CONSTRUCTION EXTERNAL VIEW 2GP CDA N° PART NAME Principal pump Electric motor Baseplate Baseplate foot Suction manifold Union ball valve Check valve Threaded female cap Nipple for air feeders Discharge manifold Union ball valve Threaded female cap Control panel Control panel frame…
-
DIMENSIONS AND WEIGHT
-
DIMENSIONS AND WEIGHT
7 DIMENSIONS AND WEIGHT PACKING 2GP Booster type 2GP CDA 1.00(M) 2GP CDA 1.50(M) 2GP CDA 2.00(M) 2GP CDA 3.00 2GP CDA 4.00 2GP CDA 5.50 Overall dimensions packing X Y Z 1230 1365 Booster+packing Weight [kg] The dimensions may change without notice. 603 EBARA Pumps Europe EBARA Pumps Europe reserves…
-
CONTROL PANEL
8 CONTROL PANEL FIXED SPEED 2EP-E SPECIFICATION Electrical panel (protection and control) for two electropumps. Manual or automatic operation through pressure transmitter. The panel is configured to start the two pumps alternately in stand-by to pressure transmitter. The electrical panel protects…
-
таблицы и схемы — в просмотре
-
CONTROL PANEL
8 CONTROL PANEL VARIABLE SPEED E-SPD+ SPECIFICATION CONTROL PANEL On board electronic device for controlling electropumps, employing inverter technology. Starts and stops the pump and modulates the speed of the motor in relation to the water demand on the system, to maintain the operating pressure…
-
CONTROL PANEL
8 SP (EFC and MFC) SPECIFICATION The control panels SP EFC/MFC series inverters modulate the operation of electropumps in response to control by the pressure transmitter (transducer measuring flow or other external signal 4-20 mA), regulating the speed of the electropumps to keep system demand…
-
таблицы и схемы — в просмотре
-
CONTROL PANEL
-
таблицы и схемы — в просмотре
-
EBARA Corporation
11-1, Haneda Asahi-cho, Ota-ku, Tokyo 144-8510 Japan Tel. +81 3 6275 7598 Fax +81 3 5736 3193 www.ebara.com I contenuti della presente pubblicazione non devono essere considerati impegnativi. EBARA Pumps Europe S.p.A. si riserva il diritto di apportare senza preavviso le modifiche che riterrà più…
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.