Каталоги продукции Airwell 2018-2019. Кондиционирование, отопление
Отопление. Каталог Airwell 2017-2018 г.
Смотрите также: Основной документ →
Загружаем документ…
Текст каталога
-
20 17 years Just feel well 2017/2018 Heating
-
Contact Us
An international sales network www.airwell-res.com Contact details [ HEADQUARTERS ] 3, avenue du Centre - Les Quadrants - Bâtiment A 78280 Guyancourt - FRANCE [ DOCUMENT LIBRARY ] http://lh.airwell-res.com [ COMMERCIAL ] E-mail: airwell-residential@airwell-res.com Tel: +33 (0)1 [ AFTERSALES ] SPARE…
-
Table of contents
PAGE HISTORY 4 SERVICES DIVISION 6 AIR TO WATER HEAT PUMPS RANGE 20 PAC BT Monobloc Low temperature heat pump 32 PAC BT Split Low temperature heat pump with DHW tank included 32 PAC HT Monobloc High temperature heat pump 42 PAC HT Split High temperature heat pump split 48 AIR TO AIR HEAT PUMPS RANGE…
-
1950 The beginning of the Airwell’s story, a french air conditioning brand. The firm developed and began the mass production of the first window unit, to offer exceptional climate conditions, mainly dedicated to European and African markets. 1970 Airwell developed a split system unit by splitting…
-
Services division
The training solution for installers Training courses In partnership with its customers, Airwell Residential provides you with Airwell Academy centers for presentations and training, both in France and worldwide. Training courses are regularly offered to present the brand’s product range and unique…
-
Training plan
Air conditioning l l l Residential air conditioning Light commercial air conditioning Air conditioning systems regulation Heating l l l Residential heating Light commercial heating Heating systems regulation Statutory trainings l l l l l Solutions for hospitals Solutions for hotels Residential…
-
Services division
-
Installation / Commissioning
CALL CENTRE qQ uick, useful response from our experts qG enerous availability qM ultilingual call centre qP rofessionals who constantly benefit from training qA customer-based, service-orientated approach! qA s much attention and help as required for the customer to be fully satisfied LOCAL AND…
-
unique
heating range , A ir to water heat pumps range A ir to air heat pumps range T hermodynamic water heaters 10
-
The exclusive and unique solution
thanks to a complete offer q Modularity second to none q A global offer of products and services , necessarily a solution for your needs: NEW BUILD REFURBISHMENT HEAT AND DHW PRODUCTION HEAT AND/OR DHW PRODUCTION PAC HT (see p. 42) PAC BT (see p. 32) High temperature monobloc Low temperature…
-
Principle of the heat pump
Heat pumps collect heat from outside the home, concentrate this heat and return it into the home. Heat exchanges in a heat pump are related to changes of state. When a liquid boils, it absorbs heat. When a gas condenses, it releases this heat. q The heat is drawn from the heat source: outside air. q…
-
Choosing a heat pump
New build or Refurbishment Domestic Hot Water production Cooling/Heating mode Airwell Solution New build Yes Cooling and heating PAC BT Split Refurbishment Yes Cooling and heating PAC BT Monobloc + DHW tank Refurbishment No Cooling and heating PAC BT Monobloc Refurbishment No Heating only PAC HT…
-
HEAT PUMP SELECTION
We recommend you to use a configuration with a back-up boiler (electrical or fossil energy) to optimize material cost and performances. q BACK-UP BOILER CONFIGURATION An Airwell heat pump can adapt to any type of issuers, namely floor heating radiators at low/medium temperature (55°C) as well as for…
-
DHW POWER CALCULATION
Needs for Domestic Hot Water Number of people in the home Daily water needs by person (in liters of water at 40 °C) ± 35 60 ± 25 50 ± 20 45 ± 20 45 ± 20 Preparation with pure accumulation: the DHW is produced in 6 or 8 hours. Equivalent volume at 60°C : with: V60 = Vx Tx − 10° 60° − 10° Tx : Storage…
-
REGULATION OF LOW TEMPERATURE HEAT PUMP PAC BT
The PAC BT range is equipped by DC Inverter compressor to meet needs. Comfort and seasonal efficiency (Inverter compressor) CAPACITY MODULATION 14 Heat pump Compressor On-Off COP 3 12 COP 2,7 Heating capacity [kVVt] 10 COP 2,5 8 COP 3,1 2 COP 4,9 2 • Optimized running at partial load = Higher COP •…
-
REGULATION OF HIGH TEMPERATURE HEAT PUMP PAC HT
Needs and heat pump power (kW) AC HT is equipped with 2 ON/OFF compressors. This technology allows to P modulate the capacity. Each compressor works with a low compression rate, ensuring longer service life and reduced electricity consumption. Heating power of the heat pump is maintained even at low…
-
Monobloc
or Split system [ MODEL NAME ] Photo Page PAC BT MONOBLOC Monobloc 22 PAC BT SPLIT Split system 32 PAC HT MONOBLOC Monobloc 42 PAC HT SPLIT Split system 48 Air to water heat pumps range LOW TEMPERATURE HEAT PUMP HIGH TEMPERATURE HEAT PUMP 20
-
Capacity
range (kW) Outdoor min Outlet water operating temperature New build temperature range or (°C) (°C) Refurbishment Mode type Domestic Hot Water Solar connection 5-16 -20 35 to 60 Refurbishment Cooling and Heating Optional: 300L No 5-17 -20 35 to 60 New build Cooling and Heating Integrated: 280L…
-
LOW TEMPERATURE HEAT PUMP
COP up to 4.85 PAC BT 5-7 kW EER up to 4.55 A ++ + PRODUCTS • Cooling and heating mode. • Monobloc system. • Available in 3PH (sizes 14 to 16). • High flexibily due to DC Inverter compressor. FEATURES DC INVERTER °C R410A FLUID HEATING MODE OPERATIONAL DOWN TO -20°C OUTDOORS DOMESTIC HOT WATER…
-
OPERATING LIMITS: User function via remote control
HEATING* Outdoor temperature (°C) 30 -2 Auxiliary heat 35 -20 Leaving water temperature (°C) 55 60 * Shaded areas indicate no heat pump operation (backup electric heater or auxiliary heat source only). COOLING Outdoor temperature (°C) Leaving water temperature (°C) 25 DOMESTIC HOT WATER* Outdoor…
-
LOW TEMPERATURE HEAT PUMP
-
LOW TEMPERATURE HEAT PUMP
PAC BT MONOBLOC TECHNICAL DATA - SINGLE PHASE Models AWHM-PACBT-MB5KW-H11 AWHM-PACBT-MB7KW-H11 AWHM-PACBT-MB9KW-H11 AWHM-PACBT-MB10KW-H11 AWHM-PACBT-MB12KW-H11 AWHM-PACBT-MB14KW-H11 AWHM-PACBT-MB16KW-H11 Code 1~230V-50Hz 7HP061015 7HP061016 7HP061017 7HP061018 7HP061019 7HP061020 7HP061021 16.33…
-
PAC BT MONOBLOC TECHNICAL DATA - THREE PHASES
Models Code 3~400V-50Hz AWHM-PAC-BT-MB-12KW-H13 AWHM-PAC-BT-MB-14KW-H13 AWHM-PAC-BT-MB-16KW-H13 7HP061022 7HP061023 7HP061023 16.30 HEATING MODE - OUTDOOR AIR REGIME +7°C / 85% HUMID BULB Water regime 30/35°C* Heating capacity kW 12.37 14.10 Power input kW 2.76 3.26 3.88 4.48 4.33 4.20 COP Water…
-
LOW TEMPERATURE HEAT PUMP
PRINCIPALES OPTIONS ET ACCESSOIRES Photo / Part number Accessory Function ACCESSOIRES FOURNIS (included) Y-shape filter Protect the heat pump from sludging and preserve optimum thermal exchange. User interface kit (digital remote controller) ON/OFF unit, outside heat source. Operation Mode setting…
-
SCHEMATIC DIAGRAM LOW TEMPERATURE HEAT PUMP - MONOBLOC
4 AHS 1 1.6 1.7 1.5 1.4 10 1.8 17 1.3 1.2 9.1 11 19 1.1 9.2 FHL1 FHL2 FHLn CAPTIONS N° NAME N° NAME 1 Outdoor unit 8 Buffer tank (field supply) 1.1 Manometer 9 Balance tank (field supply) 1.2 Pressure relief valve 9.1 Air purge valve 1.3 Expansion vessel 9.2 Drain valve 1.4 Plate heat exchanger 10…
-
LOW TEMPERATURE HEAT PUMP
SCHEMATIC DIAGRAM LOW TEMPERATURE HEAT PUMP - MONOBLOC AHS 13.3 13.1 1 1.6 1.7 17 10 1.5 1.8 19 M 1.3 17 1.1 1.4 1.2 17 13.2 23 9.1 9.2 8 24.1 12 24 FHL1 FHL2 FHLn CAPTIONS N° NAME N° NAME 1 Outdoor unit 10 Expansion vessel (field supply) P_o: outside circulation pump (field supply) 1.1 Manometer 11…
-
WITH DHW TANK INCLUDED
Renewable Energy MADE IN EUROPE A ++ + PRODUCTS q Ideal solution for radiant panel in heating and cooling mode, high temperature heater, towel dryer or fan-coil units. q .5.2 to 17 kW in heating mode / 4.1 to 15.5 kW in cooling mode over 6 models. q .Operating in heating mode up to -20°C outdoor…
-
OPERATING RANGE
COOLING PAC BT 5 TO 9 KW PAC BT 12 TO 17 KW Twu [°C] = outlet exchanger water temperature. Tae [°C]: External exchanger inlet air temperature. 1. Normal operating range 2. Normal operating range, with modulating fans 3. Operating range where the use of ethylene glycol is mandatory in relation to the…
-
WITH DHW TANK INCLUDED
-
таблицы и схемы — в просмотре
-
AWHK-PAC-BT- AWHK-PAC-BT- AWHK-PAC-BT- AWHK-PAC-BT- AWHK-PAC-BT- AWHK-PAC-BTUI-5-9KW-H11 UI-5-9KW-H11 UI-5-9KW-H11 UI-12-17KW-H11 UI-12-17KW-H11 UI-12-17KW-H11 Indoor units Part numbers 7HP010001 7HP010001 7HP010001 7HP010002 7HP010002 7HP010002 AWHK-PAC-BT-UI- AWHK-PAC-BT-UI- AWHK-PAC-BT-UI…
-
WITH DHW TANK INCLUDED
MAIN OPTIONS AND ACCESSORIES Photo / Part number Accessory Function HYDRAULICS Shut-off valve with pressure tap 7ACFH0423 Control valve Settling filter (pot) Protect the heat pump from sludging and preserve optimum thermal exchange. 7ACFH0666 7ACFH0278 Water filter 140-litre buffer tank / mixing…
-
WITH DHW TANK INCLUDED
SCHEMATIC DIAGRAM PAC BT INSTALLATION WITH THERMAL SOLAR PANEL AND TWO TEMPERATURE ZONE EF 9a 18 9b This diagram is recommended when the flow rate of the heat pump is permanently guaranteed and close to the nominal value (no thermostatically controlled valve). The buffer tank (2) completes the…
-
SCHEMATIC DIAGRAM PAC BT
INSTALLATION WITH BOILER BACK UP EF We recommend installing a zone valve to avoid heat losses by the boiler when the split heat pump is operating alone. All the members must be sized such as to minimize pressure loss. The flow rate in the heating circuit is normally guaranteed by the circulator pump…
-
Heating only
MONOBLOC HEAT PUMP COP up to 4.52 A q Ideal for renovations (HT) as well as for new construction (LT). q Constant operation at +65°C with -20°C outdoors. q 6 to 18 kW of heating over 3 models. q A single refrigerant fluid: R407C. q Possibility of installing heat pumps in cascade. q Patents Airwell…
-
PAC HT 12-6 PERFORMANCES
HEATING COP 6 14 Water = 35°C Départoutlet d'eau T=35 °C Water = 35°C Départoutlet d'eau T=35 °C Water = 45°C Départoutlet d'eau T=45 °C Water = 55°C Départoutlet d'eau T=55 °C Water = 60°C Départoutlet d'eau T=60 °C 12 Double stage double operation Fonctionnement étage Water = 45°C Départoutlet…
-
Heating only
MONOBLOC HEAT PUMP PAC HT MONOBLOC TECHNICAL DATA Models PAC HT 12-6 PAC HT 14-7 Part number 1~230V-50Hz 7OG013011 7OG013013 - Part number 3~400V-50Hz 7OG013012 7OG013014 7OG013015 3.79/A+ 3.85/A+ 3,87/A++ 6.30 7.40 8.98 SCOP/Energy label (average climate) PAC HT 18-9 OUTDOOR AIR REGIME +7°C / +6°C…
-
MAIN OPTIONS AND ACCESSORIES
Photo / Part number Accessory Function HYDRAULICS 7ACFH0423 Shut-off valve with pressure tap Control valve Settling filter (pot) Protect the heat pump from sludging and preserve optimum thermal exchange. 7ACFH0666 7ACFH0278 Water filter 140-litre buffer tank / mixing tank It protects the heat pump…
-
Heating only
MONOBLOC HEAT PUMP SCHEMATIC DIAGRAM HEAT PUMP MONOBLOC AND DOMESTIC HOT WATER EC EF This diagram is recommended when the flow rate of the heat pump is permanently guaranteed and close to the nominal value (no thermostatically controlled valve). The buffer tank (2) completes the volume of water in…
-
SCHEMATIC DIAGRAM HEAT PUMP MONOBLOC
AND DOMESTIC HOT WATER PREPARATION KIT (with plate exchanger, use of the existing tank) EC EF We recommend installing a zone valve to avoid heat losses by the boiler when the split heat pump is operating alone. All the members must be sized such as to minimize pressure loss. The flow rate in the…
-
Heating only
HEAT PUMP SPLIT HIGH TEMPERATURE COP up to 4.52 A Made in France + PRODUCTS • Very low noise level: 65 dB(A) for outdoor unit, 41 dB(A) for indoor unit. • Very high performance, COP up to 4.52. • Aesthetics and aluminium finish. • Light and compact wall unit (smaller in size than a boiler). • Large…
-
PAC HT SPLIT 12-6 PERFORMANCES
HEATING COP 6 14 Water = 35°C Départoutlet d'eau T=35 °C Water = 45°C Départoutlet d'eau T=45 °C Water = 55°C Départoutlet d'eau T=55 °C Water = 60°C Départoutlet d'eau T=60 °C Water = 65°C Départoutlet d'eau T=65 °C 12 Fonctionnement double étage Double stage operation Départoutlet d'eau T=35 °C…
-
Heating only
HEAT PUMP SPLIT HIGH TEMPERATURE PAC HT SPLIT TECHNICAL DATA Models PAC HT SPLIT 12-6 PAC HT SPLIT 14-7 PAC HT SPLIT 18-9 Part number indoor units 7OG160001 7OG160001 7OG160002 Part number outdoor units 1~230V-50Hz 7SP063001 7SP063003 - Part number outdoor units 3~400V-50Hz 7SP063002 7SP063004…
-
MAIN OPTIONS AND ACCESSORIES
Photo / Part number Accessory Function HYDRAULICS 7ACFH0423 Shut-off valve with pressure tap Control valve Settling filter (pot) Protect the heat pump from sludging and preserve optimum thermal exchange. 7ACFH0666 7ACFH0278 Water filter 140-litre buffer tank / mixing tank It protects the heat pump…
-
Heating only
HEAT PUMP SPLIT HIGH TEMPERATURE SCHEMATIC DIAGRAM HEAT PUMP SPLIT AND DOMESTIC HOT WATER (hydraulic tank) EC EF This diagram is also recommended for heating installations with highly variable operating rates (presence of thermostatically controlled valves). Observance of this minimum volume is…
-
SCHEMATIC DIAGRAM HEAT PUMP SPLIT
INSTALLATION WITH DOUBLE ZONE (heating floor and radiators) EC EF 9a 18 9b The split heat pump manages a radiator zone (high temperature) and a heating floor zone (low temperature) via a flow sensor in the floor, a modulating three-way valve (3-point 220 V motor) and one circulator pump per zone.…
-
Heating only
General recommendations for installation of air-water heat pump HYDRAULIC ACCESSORIES AIRWELL ■■Disconnector on water system ■■Security group Regulation needs to have a disconnector type CA or BA installed with a power less than 70kW plugged on water system, depending on the heat transfer fluid. The…
-
C
GENERAL CRECOMMENDATIONS C SnowdriftsSnowdrifts D Condensate Condensate discharge discharge D Snowdrifts E rge D Snowdrifts Condensate discha EStrong winds Strong w E Condensate discharge Strong winds D fts Condensate discharge E Strong winds To avoid the water freezing downst drain, lay the tube…
-
[ MODEL NAME ]
Page DUCTED MEDIUM STATIC PRESSURE MONOSPLIT Air to air heat pump range DLSE+VAV 56 58
-
5 kW 24 7 kW 57
-
Solution
unique DLSE Plus VAV Variable Air Volume 58
-
Zone control: Ideal temperature in each room
-
ZONE CONTROL FUNCTION
q Smart air conditioning: Controls up to 6 rooms. q Each zone has a standalone remote control, to control temperature, “I Feel” and ON/OFF. q Option to define automatic damper movement or manually to keep max. opening position. q By-pass damper operates according to system load, which ensures air…
-
EASY INSTALLATION
q Simple wiring connection by connectors and set up. q Up to 70m between indoor and outdoor units. q Monosplit indoor unit: time saving (little tubing). q Option for installing the control box besides the unit. q Water pump and overflow switch built in. Use our design document to select easily your…
-
How to order?
q For each installation select first the damper type, round or rectangular. q The main controller is identical except the set up which is done during the installation. q After that, select motorized round damper, by-pass damper and plenum (see table below). ROUND APPLICATION Motorized circular…
-
RECTANGULAR APPLICATION
19° 20° 22° 23° 24° 18° MOTORIZED RECTANGULAR TYPE ACCESSORIES Part description Product code Main controller VAV kit 7ACEL1641 Motorized grill (30 cm x 15 cm) kit (Wireless controller C85-R included) 7ACEL1642 Motorized grill (40 cm x 15 cm) kit (Wireless controller C85-R included) 7ACEL1643…
-
DLSE+VAV DUCTED MEDIUM
Air/air heat pump A ++ STATIC PRESSURE MONOSPLIT q “I Feel” function with precise room temperature control. q Unique fan technology increases air volume and high static pressure while keeping low noise level. q Quiet operation by using aerodynamic centrifugal fan. q Space saving due to low unit…
-
DLSE TECHNICAL DATA
-
Thermodynamic
water heaters range 66
-
Thermodynamic water heaters range
[ MODEL NAME ] Page THERMODYNAMIC DUCTED WATER HEATER 180 L TDF 190/1.5 70 THERMODYNAMIC DUCTED WATER HEATER 280 L TDF 300/3.5 72 68
-
DUCTED
ENAMEL 69
-
FI
ED BY TDF 190/1.5 180-L DUCTED WATER HEATER LCIE CE RT I Thermodynamic water heaters ELECTRICITY PERFORMANCE + PRODUCTS • Automatic, weekly, antilegionella function. • Multiple safeguards: pressure valve, double safeguard against rises in temperature. • No contamination risk: the condenser coil is…
-
TDF 190/1.5 TECHNICAL DATA
HWHM-TDF190/1.5-H31 Model Part number 7HP030004 COP 2.61 Water heating capacity W 1450 Rated capacity W/A 3900/17 Power supply 220-240V~ 50Hz Operation control Auto/Manual startup, error alarm, timer,etc Protection system TCO1, TCO2, T&P valve, automatic defrost, surge protector etc. Electric heater…
-
FI
ED BY TDF 300/3.5 280-L DUCTED WATER HEATER LCIE CE RT I Thermodynamic water heaters ELECTRICITY PERFORMANCE + PRODUCTS • Automatic, weekly, antilegionella function. • Multiple safeguards: pressure valve, double safeguard against rises in temperature (manual/automatic). • No contamination risk: the…
-
TDF 300/3.5 TECHNICAL DATA
AWHM-TDF300/3.5-H31 Model Part number Enamel 7HP030007 COP 2.74 Water heating capacity W 3000 Rated capacity W/A 4300/18.7 Power supply 220-240V~ 50Hz Operation control Auto/Manual startup, error alarm, timer,etc Protection system TCO1, TCO2, T&P valve, automatic defrost, surge protector etc.…
-
PEP - Ecopassport®
Airwell is part of an eco-environmental approach including a life cycle analysis of our products while building a Product Environmental Profile (PEP). This life cycle analysis (LCA) allowed to inventory and quantify, all along the products lifecycle, the physical material and energy flow associated…
-
Tool box
HELP FOR DIMENSIONING THE HYDRAULIC ACCESSORIES ■■Buffer volume Airwell recommends a minimal water capacity being plugged to the heat pump. This capacity aloows: q To ensure a sufficient inertia q .Maintain a minimum run time of the compressor (anti short cycle) Buffer volume range for a PAC BT…
-
selection
NEW BUILD HEAT PUMP SELECTION Heat pump for heating and/or domestic hot water Do you need an estimate for your Airwell heat pump for your customer? Please fill in the form below and send it to your distributor. INFORMATION SHEET to be filled in by your approved installer File reference: Date…
-
REFURBISHMENT
HEAT PUMP SELECTION ❑ Boiler back-up ❑ Boiler replacement INFORMATION SHEET to be filled in by your installer File reference: Date: INSTALLER Company: Address: Post code: Telephone: Fax: Name: Town: Mobile: E-mail: CUSTOMER Company: Address: Post code: Telephone: Fax: Name: Town: Mobile: E-mail…
-
Icons guide
Icons guide HEAT PUMPS / THERMODYNAMIC WATER HEATERS R407C FLUID R407C refrigerant fluid. °C HEATING MODE OPERATIONAL DOWN TO -20°C OUTDOORS HIGH TEMPERATURE UP TO 65°C Heating mode available even at very low outdoor temperatures through special design of the unit. High temperature production up to…
-
HEATING GB 2017 - AIRWELL RESIDENTIAL SAS - Specifications subject to change without notice. Pictures non contractual. Printed in UE. AIR CONDITIONING & HEATING Our Aftersales Service Export Tel. +33 (0)1 SPARE PARTS ORDERS: e-mail sp@airwell-res.com TECHNICAL SUPPORT: e-mail…
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.