Инструкция на Промышленные чиллеры S&A CW-5000/5200. Руководство пользователя
Промышленные чиллеры S&A (Teyu) серий CW-5000 и CW-5200: меры предосторожности, устройство, установка, эксплуатация и настройка параметров, сигнализация расхода. Руководство пользователя. Документ на английском языке.
Загружаем документ…
Текст инструкции
-
S&A
-
Contents
<1> Cautions <2> Parts introduction <3> Installation <4> Operation and parameters adjustment <5> Flow alarm and output ports <6> Specifications <7> Simple troubleshooting 2 13
-
Thank you for using the machine from GUANGZHOU TEYU
ELECTROMECHANICAL CO., LTD. Please read the installation instructions carefully before installing and operating and keep it properly. This installation instructions is not a quality assurance. GUANGZHOU TEYU ELECTROMECHANICAL CO., LTD. reserves the right to the interpretation of correction of…
-
8. Professional use only!
The appliance is not to be used by children or persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction, children being supervised not to play with the appliance! <2> Parts introduction TEMPERATURE…
-
<3> Installation
It is very simple to install this industrial cooling machine. The installation for the first time of the new machine can be carried out by following steps: 1. Open the package to check if the machine is intact and all the necessary accessories are completed. 2. Open the injection port to feed…
-
<4> Operation status and parameters
adjustment The new T503 intelligent temperature controller does not need to adjust the controlling parameters under normal circumstance. It will self-adjust controlling parameters according to room temperature for meeting equipment cooling requirements. The new T504 intelligent temperature…
-
2. Restore to factory settings
Before machine startup, please press and hold Ʒ ͩ button until the controller displays rE, 6 seconds later after releasing the button, the controller works in normal order. Then all parameters settings of the controller have been restored to factory settings. 3. Alarm function (1) Alarm Display: E1…
-
General settings adjustment Press SET button˄ ˄SET˅to enter into the user-defined state. Meanwhile, D1 flashes to indicate that the controller is in parameters setup status. (1) Under intelligent mode, the control panel displays the temperature difference value between water and air (F1). (2) Under…
-
7. Advanced parameters adjustment case
Order Code 1 F0 2 F1 3 F2 4 F3 5 F4 6 F5 7 F6 8 F7 9 F8 10 F9 Item Temperature setting Temperature Difference values Cooling hysteresis Way of control Value in case 1 Value in case 2 Value in case 3 T-503 Temperature controller Factory Setting T-504 Temperature controller Factory Setting -2 -2 -3…
-
<5> Flow alarm and output ports
(1) In order to guarantee the equipment will not be damaged while cooling water circulation is out of control, CW-5000/5200series chillers possesses an unique low flow alarm protection. Flow alarm output ports and the wiring diagram (2) Flow alarm causes of circulating cooling water and working…
-
<6> Specifications
-
<7> Simple troubleshooting
Failure Failure Cause Power cord is not plugged in place Machine turned on but unelectrified Fuse burnt-out Flow Alarm (panel red light is on)use a water pipe directly connect to the water outlet and inlet but still without water flowing Water level in the storage water tank is too low Water…