Инструкция на Тепловые насосы воздух/вода инверторные Ecoview серии EV-DCS6-18
Тепловые насосы воздух/вода инверторные Ecoview серии EV-DCS6/ EV-DCS9/ EV-DCS12/ EV-DCS15/ EV-DCS18. Инструкция по установке и эксплуатации.
Смотрите также: Коды ошибок: 7 кодов →
Загружаем документ…
Текст инструкции
-
DC inverter split type heat pump
Installation & User Manual Model: EV-DCS6 / EV-DCS9 EV-DCS12 / EV-DCS15 EV-DCS18 Please properly keep this manual. Please read this manual carefully before using the machine.
-
Content
1.Safe precautions 1 2.Structure 2 3.Installation 6 4.Electric connection 16 5.User instruction 17 6.Comon control functions 22 7.Trial operation 27 8.Unit operation and performance 28 9.Maintenance and trouble shooting 30 10.Wiring diagram 32
-
The safety of you and your families is the most important ! This machine belongs to class I equipment. Please ensure the reliable grounding before using it. Note: Please don’t use this machine if there is no grounding or the grounding is not reliable If you are not sure if the grounding is reliable…
-
1.Safety Precautions
!Warning Requirements for the installation environment The installation location must be ventilated, waterproof, sun-proof, and requires a convenient power supply, water supply and drainage channels. Customer's electrical environment must be in accordance with local electrical safety regulations.…
-
2-1 Outer Structure (Indoor Unit)
500mm 800mm 255mm 1-Controller 2-Liquid connection 3-Through hole 4-Gas connection 5-Water inlet 6-Water outlet Picture 2.1 The photo in this manual is only for explanations purpose. If the appearance, function are not in accordance with the real one, please in kind prevail. Model: EV-DCM9 2
-
2- 2 Outer Structure (Outdoor Unit)
1105mm 845mm 425mm 460mm 730mm 1 2 1- Maintenance panel 2-Pressure gauge 3- Wind net 4- Liquid valve 5- Gas valve Picture 2.2 Model: EV-DCM9 3
-
2-3 The main components name (Indoor unit)
1 Indoor unit front panel 7 Hole for wire connection 2 Indoor unit case 8 Automatic vent valve 3 Plate heat exchanger 9 Water flow switch 4 Water pump 10 Electrical heater 5 Controller 11 3-way valve 6 Indoor terminal block 12 Expansion tank Remark: The photo in this manual is only for explanations…
-
2.Componenents name
2- 4 The main components name (Outdoor unit) 13 Evaporator 25 Outdoor terminal block 14 Outdoor unit top panel 26 High pressure gauge 15 Outdoor unit front panel 27 Reactance 16 Wind net 28 Hole for power cable 17 Service valve 29 Hole for control wire 18 Fan blade 30 Low pressure switch 19 Fan…
-
!Attention
The following installation places may cause the malfunction of the machine The places where there is mineral oil; The place that contains salt in the air, such as the seaside; The place that contains corrosive gas, such as hot spring area; The place where the powers supply voltage fluctuates…
-
3-2 Movement
1)Because the gravity center of the unit is not in the middle, when you move the machine, please beware of the drumping. 2) Please do not hold the air inlet, or it will be deformed. 3) In the movement, please don’t touch the fan blade by hand or other things in order to prevent from the damage on…
-
3-4 The space of installation and maintenance
Please leave enough maintenance space as the below before the installation. >60cm >30cm >60cm >30cm >30cm Air inlet >60cm Maintenance space Air inlet Maintenance space Air inlet Air outlet >200cm Install the anti-vibration pads and fix them with expansion screws Figture3. 2 Figure 3.1 Back to back…
-
3- 5 The space of installation and maintenance for the
indoor unit 320mm 412mm The indoor unit needs to be mounted on the wall through the hanging plate. The fixed dimension of the hanging plate refer to the picture 3.5. Picture 3.5 >200mm >300mm >300mm >500mm 1400mm Picture 3.6 Please leave enough maintenance space for the indoor unit as the above…
-
3- 6 Installation of the indoor unit
1)Use a percussion drill to drill four holes in the wall, the dimension of the holes refer to the picture 3.5 2) Fix the four expansion bolts in the four mounting holes, refer to the picture 3.8. 3) Put the hanging plate onto the expansion bolts, and tighten with the nuts, refer to thepicture 3.9.…
-
3- 7 Unit piping and wiring
Install the pipes according to the following methods. 1) Place outdoor unit and indoor unit firmly, and install one end of the refrigerant connecting pipes to the connectors on indoor unit. 2) Pull the other end of the refrigerant connecting pipes to the outdoor unit, shown as picture 3-11. 3)…
-
3-8 Installation of the water pipes
1)To reduce the resistance of the water pipe as much as possible , reducing the elbow position and variable diameter can be adopted. 2) In the process of the piping connection, please make sure the whole system to be clean, no rust and no other dirt, in order to prevent the piping blockage. 3) Leak…
-
3-10 Antifreezing measures
1) When the ambient is lower than minus 5℃, please make sure the unit is energized. 2)The unit is set with anti-freeze protection program, in the state of power on, when the ambient temp gets to the protection value, the unit will run the water pump automatically and even start the heating to…
-
3- 11 Installation diagram
a. Installation for only heating buffer tank indoor unit floor heating circulation pump outdoor unit bypass vavle filter water segregator water collector to water supply water supply valve drain valve to the sewer room floor heating1 room floor heating2 b. Installation for only hot water hot water…
-
c. Installation for hot water & heating
hot water tank indoor unit outdoor unit water supply valve drain valve to water supply to the sewer buffer tank floor heating circulation pump bypass vavle filter 3way valve water segregator water collector to water supply water supply valve drain valve to the sewer room floor heating1 room floor…
-
4.Electric connection
4-1 Electric wiring !Attention 1) The unit should use the dedicated power supply; the power supply voltage should consist with the local rules of the rated voltage. 2) The external power supply circuit must have grounding and the unit power supply grounding wire should be connected to the external…
-
5-1 Controller key description
Up On/ off key Menu Prg Back key E sc Down Confirm key Figure 5. 1 1)On/off key: Press this key to choose to turn on or turn off the unit. 2)Menu:In main interface, press this key to enter into the menu. Hold this key for 5s to start the manual sterilization function. 3)Back key: At menu stage…
-
5- 2 Menu and parameters
In main interface, press Prg key to enter into the menu. All unit status and parameters are in this menu. There are 5 main menus, as follows: - Function setting - Parameter setting - Failure records - Time setting - Temp. curve display Main menu 1: Function setting Sub-menu Parameter Meaning Range…
-
Main menu 2: Parameter setting (requiring password)
Sub-menu Parameter Meaning Range Default Remark 1.1 DHW △T. DHW temp. drop for restart 1~20℃ 5℃ Adjustable 1~20℃ 2℃ Adjustable -20~20℃ 1℃ Adjustable 1.3 EEV Ovetheat/C AC heating temp. drop for restart AC heating target superheat 1.4 EEV Ovetheat/H AC cooling target superheat -20~20℃ 1℃ Adjustable…
-
Sub-menu
Parameter Meaning Range Default Remark 2.1 Def. Cycle Defrost interval 30min~90min 40min Adjustable -20~5℃ -7℃ Adjustable 1~30℃ 10℃ Adjustable 2.4 Def. Max. time Max. defrost duration 1min~12min 8min Adjustable 3.1 Comp. control Compressor speed control Auto/manual Auto Adjustable 3.2 Comp. Freq.…
-
Sub-menu
Parameter 5.4 EEV overheat Meaning 5.4 target superheat Range 1~15 Default 6 5.5 EEV mode 5.5 EEV mode Auto/manual Auto 5. EVI parameter 5.6 Initial step 5.6 EVI EEV initial step 0~480 30 5.7 Adjust step 5.7 EVI EEV manual step 0-480 30 Change Change password password Restore default set change the…
-
6-1 Circulating pump
The unit receives signal to turn on, circulating pump starts 5min before compressor does. 1). The unit receives signal to turn off, circulating pump stops 5min after compressor does. 2). Circulating pump keeps on during defrosting. 3). Compressor stops after reaching set temperature, circulating…
-
2. Heating mode
1). AC heating mode 1.1) Heating water temperature set - When set to AUTO(para. 02 set to 1), set temperature runs as per heating curve, please refer to “AUTO heating” function. - When set to manual, heating water temperature set value T S E T H range 1865℃,default 25℃ 1.2) Heating operation - 3-way…
-
Formula as follows
AC tank target temp.= Initial BTW temp +(Max BTW temp – initial BTW temp)⁄ 35 x (Set room temp –outdoor temp.) note:15℃≤AC tank target temp.≤60℃ for example: set room temp = 20℃ Max BTW temp= 48℃ Initial BTW temp= 20℃ At the following outdoor temp. the AC tank target temp. is: Outdoor temp.=20℃,…
-
3. DHW mode
3.1 DHW temperature setting DHW set temperature T W B S E T range 30-60℃, default set temperature 50℃. 3.2 Normal heating operation - 3 way valve at water circuit is energized, and 4-way valve is dis-energized, and circulating pump turns on. - The outdoor fans have 2 speeds, and run at the speed…
-
- Heat pump controller is in DHW mode (as long as this mode is selected by controller
and heat pump is at ON status, regardless standby status by reaching set temperature or not). - Parameter Solar system is set to ON. - Parameter Solar mode is set to DHW or DHW+Heating. - Solar sensor temp. –DHW temp.>Parameter Start △T When solar sensor temp. –DHW temp. < Parameter Start △T…
-
7.Trial operation
7- 1 Inspection before the trial operation Please check if the following items before the trial operation. 1)If the unit is installed correctly; 2)If the piping and wiring are correct; 3)If the drainage is smooth; 4)If the thermal insulation is well done; 5)If the grounding wire is connected…
-
8.Unit operation and performance
8-1 explanation for some phenomena during the unit operatio 1)Start delay; During the unit running, if the unit is turned off or stops automatically, if restart the unit, the unit has to wait for 3 minutes to start. This setting is the protection on compressor instead of fault. 2)Defrosting ; In the…
-
таблицы и схемы — в просмотре
-
9.Maintenance and trouble shooting
9- 1 Fault code table Wire controller error Standby Normal running Err 00 Err 01 Err 02 Err 06 Err 04 Err 05 Err 07 Err 08 Err 09 Err 10 Err 11 Err 12 Err 13 Err 14 Err 15 Err 16 Err 18/ Err 19 Err 20 Err 21 Err 22 Err 23 Err 31 Err 32 Err 33 Err 34 Err 35 E24 E25 E26 E27 E28 E29 E30 Meaning Main…
-
9.Maintenance and trouble shooting
9 - 1 Malfunctions and treatment !Warning If any fault occurs and the unit stops running, please contact your dealer or after-sales technician to solve the problem. Please do not dismantle the unit and do repair by your own in order to avoid any unnecessary injury. When the unit has abnormal fault…
-
1 0.Wiring diagram
Indoor unit 32
-
10.Wiring diagram
Outdoor unit 33
-
Here is the series number of the heat pump
Please check above series number whether is the same as the heat pump, and always provide the series number if you ask for help from retailer.
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.