Инструкция на Электрические накопительные водонагреватели Ariston серии BOOSTER
Электрические накопительные водонагреватели Ariston серии BOOSTER. Инструкция по эксплуатации.
Загружаем документ…
Текст инструкции
-
Realizzazione grafica : Andreani - Foligno - Stampa: Litograf s.r.l. - Jesi
025.0.60.055.1.05 Merloni TermoSanitari SpA Viale Aristide Merloni, 45 60044 Fabriano (AN) Tel. 0732.6011 Telefax. 0732.602331 Telex 560160 http://www.mts.it Rapido Scaldacqua Elettrico Rapido Rapid electric water heater Chauffe-eau Electrique Rapide Elektrischer Wasserdurchlauferhitzer
-
D
W ear customer, e would like to congratulate you on having purchased the BOOSTER water heater, the most innovative of all electric storage water heaters. W e are convinced that BOOSTER will fully satisfy your needs, because it is the fruit of our experience in top quality and technology which…
-
1 HOW TO REMOVE THE PACKAGING
Operations that must be carried out by at least 2 people. 2 INSTRUCTION HANDBOOK SEM0510-040 SEM0510-050 1 First place the box in the position shown in the diagram and open it. Then consult your instruction handbook. 3 Hold the box on both sides and carefully turn it upside down. 4 SEM0510-025…
-
2 DESCRIPTION OF THE SYSTEM
5 Adjustment knob Control panel Cover 1/2" G hot water outlet 1/2" G cold water inlet Sector Voltage feed plug and cable Rating plate BO0299-010 The water heaters are equipped with water intake and outlet connections at the bottom. 2.1 ACCESSORIES SUPPLIED WITH THE HEATER 6 SC1406-202 Safety valve 7…
-
1 Lower heating element 2 Upper heating element H Magnesium anode Boiler Flange Safety thermostat probe Changeover switch thermostat probe 8 Operational thermostat probe 4 1 L 5 BO0299-020 The upper heating element 2 enables only a limited amount of water (H) to be heated. This system gives you a…
-
3.2 TECHNICAL DATA
-
CONNECTION DIAGRAM C 2 1 BO0299-075 NORMAL BOOSTER 11 ELECTRICAL WIRING DIAGRAM BOOSTER Red warning light NORMAL Red warning light Upper green warning light Upper heating element Changeover switch + °C 2 (C) 1 2 Changeover switch thermostat 3 Lower heating element Operational thermostat Lower green…
-
4 GENERAL WARNINGS
• electrical wiring must comthe data on the rating plate ply with what is specified showing the characterisin paragraph 5.3; tics of the appliance; • the safety valve supplied • the earth must be installed with the appliance must correctly; not be tampered with and • do not use extensions or must…
-
5.3 WIRING
The appliance must be connected to the mains supply by means of a differential twopole magnetothermal switch (30 mA) in compliance with the current IEC standards (contact opening of at least 3 mm, preferably equipped with fuses), or by means of the plug. 15 I 0 This switch must be used each time the…
-
7 DESCRIPTION OF THE CONTROLS
BO0299-040 BOOSTER FUNCTION 1 Upper heating element warning light on Lower heating element warning light on Adjustment knob "BOOSTER" button "BOOSTER" function warning light "NORMAL" button "NORMAL" function warning light When the BOOSTER button 4 is pressed, the 2 warning light 5 switches on and…
-
8.1 HOW TO REMOVE THE COVER
In order to gain access to the electrical part, remove cover E as follows: • unscrew screws A-B-C-D that fasten it; • remove the cover by pulling it downwards as shown in the diagram 18. 17 18 B A E D C SEM0510-280 BO0299-090 8.2 HOW TO REMOVE THE FLANGE • Disconnect the appliance from the…
-
22 V BOO15199-F20 BOO15199-F21 8 • Remove the earth screw V. • Remove screws 8 so that the electrical system is disconnected from the water heater. 23 24 BO0299-060 BOO15199-F15 F • Use a 13 mm spanner to remove flange F check nuts. • Remove the flange. 8.3 REGULAR MAINTENANCE 8.3.1 HOW TO REMOVE…
-
8.3.2 WATER SAFETY DEVICE
26 SC1406-200 The safety valve must be made to work regularly at least once a month. Move the lever up and down several times in order to make sure it is not blocked by scale. 8.4 SPECIAL MAINTENANCE 8.4.1 REPLACEMENT OF ANODE The magnesium anode 2 must be replaced at least once every two years…
-
Merloni TermoSanitari S.p.A. is not bound by the data and characteristics described in this handbook and reserves the right to make any modifications it deems necessary, without priornotice or replacement. This appliance complies with the requirements set forth in EMC directive 89/336/EEC concerning…
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.