Инверторные мультисплит-кондиционеры. Каталог 2008г.
M5MSX 020/025/030 A/AR. Инверторные мультисплит-кондиционеры. Каталог 2008г.
Загружаем документ…
Текст каталога
-
Catalog
-
Nomenclature
-
Outdoor
-
Nomenclature
-
Features
Higher Energy Savings The compressor in McQuay DC Multi Split Inverter is programmed to run at the optimum speed. The compressor speed is controlled by input frequency that varies according to the indoor load requirements. Once the indoor set temperature is achieved, the input frequency supply to…
-
Application Information
Operating Range Ensure the operating temperature is in allowable range Cooling only Outdoor temp. (°C DB) 46 Cautions: 35 STD The use of your air conditioner outside the range of working temperature and humidity can result in serious failure. Indoor temp. (°C WB) Heat pump Heating Cooling 6 Outdoor…
-
Refrigerant Circuit Diagram
-
Controllers
G11 Remote Controller Temperature Setting To set the desired room temperature, press the button to increase or decrease the set temperature. On/Off Button • Press Once to start the air conditioner • The temperature setting range is from 16°C to 30°C • Press again to stop the unit • Press both…
-
Installation
Safety Precautions Before installing the air conditioner unit, please read the following safety precautions carefully Warning • Installation and maintenance should be performed by qualified persons who are familiar with local code and regulation, and experienced with this type of appliance. • All…
-
Installation of the indoor unit
The indoor unit must be installed in such a way so as to prevent short circuit of the cool discharged air with the hot return air. Please follow the installation clearance shown in the figure. Do not place the indoor unit where there could be direct sunlight shinning on it. Also, this location must…
-
Installation Diagram
L4 VERTICAL HEIGHT DIFFERENCE MAX. H L3 L2 INDOOR UNIT L1 OUTDOOR UNIT Indoor unit combination for outdoor unit M5MSX 020A/AR, M5MSX025A/AR and M5MSX030A/AR Indoor units with model name M5WMX 010G/GR, M5WMX015G/GR and M5WMX020G/GR could be coupled with this outdoor unit. The following table shows…
-
Installation of outdoor unit
-
Refrigerant piping work
-
Piping Works
Cutting copper tube • Do not use contaminated or damaged copper tubing. Do not remove plastic, rubber plugs and brass nuts from the valves, fittings, tubings and coils until you are ready to connect suction or liquid line into valves or fittings. • If any brazing work is required, ensure that the…
-
Electrical wiring connection
IMPORTANT : The figures shown in the table are for information purpose only. They should be checked and selected to comply with the local/national codes of regulations. This is also to the type of installation and conductors used. 1 2 INDOOR UNIT D TERMINAL BLOCK 3 PO W E R S U PPL Y N L 1 INDOOR…
-
Voltage range
M5WMX010G/15G M5WMX020G/GR 220V-240V / 1 Ph / 50Hz + 3.0 3 1.5 2.5 Power supply cable size (mm ) Number of wire 2 Interconnection cable size (mm ) Number of wire Recommended time delay fuse for O/D unit • The table above shows the electrical wire sizing for different connection cables. If the length…
-
Vacuuming and charging
Purging the piping and indoor unit Except for the outdoor unit which is pre-charged with refrigerant R22, the indoor unit and the refrigerant connection pipes must be air-purged because the air containing moisture that remains in the refrigerant cycle maycause malfunction of the compressor. • Make…
-
Indicator Lights
IR signal receiver When an infrared remote control operating signal has been transmitted, the signal receiver on indoor unit will made a (beep) sound to comfirm acceptance of the signal transmission. The table shows the LED indicator lights for the indoor air conditioner unit under normal operation…
-
Air conditioner unit opeartion
Dry mode • When the air humidity is high, the unit can operate in dry mode. Press <MODE> button and choose <DRY>. • If the room temperature is 2°C higher than the set temperature, the air conditioner will operate under cooling mode until it reaches within the 2°C range of difference compared to the…
-
Electrostatic Filter
Dual Action Electrostatic Air Purifying and Deodorizing Filter Media and Filter Frame Action 1Electtrostatic air purifying filter Action 2Deodorizing filter Removes microscopic dust, smoke and small invisible particules to keep the room air clean with pre-charged electrostatic polypropylene filter.…
-
Engineering and Physical Data
General Data - Cooling Only MODEL OUTDOOR UNIT M5MSX 020A INDOOR UNIT NOMINAL COOLING CAPACITY M5WMX 010G M5WMX 015G Btu/h 19000 (4500 - 21000) W 5570 (1320 - 6150) NOMINAL TOTAL INPUT POWER W 1500 (355 - 1870) NOMINAL RUNNING CURRENT A 6.75 (1.61 - 8.42) 220 - 240 / 1 /50 POWER SOURCE V/Ph/Hz…
-
OUTDOOR UNIT
M5MSX 025A INDOOR UNIT NOMINAL COOLING CAPACITY M5WMX 010G M5WMX 015G Btu/h 22000 (9000 - 24000) W 6450 (2640 - 7030) NOMINAL TOTAL INPUT POWER W 1815 (590 - 2200) NOMINAL RUNNING CURRENT A 8.13 (3.18 - 9.86) 220 - 240 / 1 /50 POWER SOURCE V/Ph/Hz REFRIGERANT TYPE CONTROL INDOOR UNIT AIR FLOW R410A…
-
OUTDOOR UNIT
M5MSX 025A INDOOR UNIT M5WMX 020G Btu/h 22000 (9000 - 24000) W 6450 (2640 - 7030) NOMINAL TOTAL INPUT POWER W 1815 (590 - 2200) NOMINAL RUNNING CURRENT A 8.13 (3.18 - 9.86) 220 - 240 / 1 /50 NOMINAL COOLING CAPACITY POWER SOURCE V/Ph/Hz REFRIGERANT TYPE CONTROL INDOOR UNIT AIR FLOW R410A OPERATION…
-
OUTDOOR UNIT
M5MSX030A INDOOR UNIT NOMINAL COOLING CAPACITY M5WMX010G M5WMX015G Btu/h 26000 (4500 - 29000) W 7620 (1320 - 8500) NOMINAL TOTAL INPUT POWER W 2350 (400 - 2815) NOMINAL RUNNING CURRENT A 10.44 (1.81 - 12.50) 220 - 240 / 1 /50 POWER SOURCE V/Ph/Hz REFRIGERANT TYPE CONTROL INDOOR UNIT AIR FLOW R410A…
-
OUTDOOR UNIT
M5MSX 020AR INDOOR UNIT M5WMX 010GR Btu/h NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY M5WMX 015GR 19000 (4500 - 21000) W 5570 (1320 - 6150) Btu/h 21000 (4500 - 23000) W 6150 (1320 - 6740) NOMINAL TOTAL INPUT POWER (COOLING) W 1500 (355 - 1870) NOMINAL TOTAL INPUT POWER (HEATING) W 1630 (350…
-
OUTDOOR UNIT
M5MSX 025AR INDOOR UNIT M5WMX 010GR Btu/h NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY M5WMX 015GR 22000 (9000 - 24000) W 6450 (2640 - 7030) Btu/h 25000 (4500 - 26000) W 7330 (1320 - 7620) NOMINAL TOTAL INPUT POWER (COOLING) W 1815 (590 - 2200) NOMINAL TOTAL INPUT POWER (HEATING) W 1900 (400…
-
OUTDOOR UNIT
M5MSX 025AR INDOOR UNIT M5WMX 020GR Btu/h NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY 22000 (9000 - 24000) W 6450 (2640 - 7030) Btu/h 25000 (4500 - 26000) W 7330 (1320 - 7620) NOMINAL TOTAL INPUT POWER (COOLING) W 1815 (590 - 2200) NOMINAL TOTAL INPUT POWER (HEATING) W 1900 (400 - 2155)…
-
OUTDOOR UNIT
M5MSX 030AR INDOOR UNIT M5WMX 015GR M5WMX 010GR Btu/h NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY W 7620 (1320 - 8500) Btu/h 28000 (4500 - 32000) W 8210 (1320 - 9380) NOMINAL TOTAL INPUT POWER (COOLING) W 2350 (400 - 2815) NOMINAL TOTAL INPUT POWER (HEATING) W 2030 (400 - 2755) NOMINAL RUNNING…
-
OUTDOOR UNIT
M5MSX 020A INDOOR UNIT M5WMX 010GR TYPE 1 QUANTITY INDOOR FAN INDOOR FAN MOTOR 1 ACRYLO NITRILE STYRENE MATERIAL DRIVE DIRECT DIAMETER mm/in 87 / 3.4 LENGTH mm/in 636 / 25.0 TYPE INDUCTION Q'TY 1 INDEX OF PROTECTION (IP) IP24 TYPE OUTDOOR FAN M5WMX 015G ANTI FUNGUS CROSS FLOW FAN PROPELLER FAN…
-
M5MSX 025A
OUTDOOR UNIT INDOOR UNIT M5WMX 010G TYPE 1 QUANTITY INDOOR FAN INDOOR FAN MOTOR M5WMX 015G ANTI FUNGUS CROSS FLOW FAN 1 ACRYLO NITRILE STYRENE MATERIAL DRIVE DIRECT DIAMETER mm/in 87 / 3.4 LENGTH mm/in 636 / 25.0 TYPE INDUCTION Q'TY 1 INDEX OF PROTECTION (IP) IP24 TYPE OUTDOOR FAN PROPELLER QUANTITY…
-
OUTDOOR UNIT
M5MSX 025A INDOOR UNIT M5WMX 020G TYPE INDOOR FAN INDOOR FAN MOTOR ANTI FUNGUS CROSS FLOW FAN QUANTITY 1 MATERIAL ACRYLO NITRILE STYRENE DRIVE DIRECT DIAMETER mm/in 87 / 3.4 LENGTH mm/in 636 / 25.0 TYPE INDUCTION Q'TY 1 INDEX OF PROTECTION (IP) IP24 TYPE OUTDOOR FAN PROPELLER QUANTITY 1 MATERIAL…
-
OUTDOOR UNIT
M5MSX030A INDOOR UNIT M5WMX010G TYPE INDOOR FAN MOTOR 1 MATERIAL DRIVE DIRECT DIAMETER mm/in 87 / 3.4 LENGTH mm/in 636 / 25.0 TYPE INDUCTION Q'TY 1 INDEX OF PROTECTION (IP) IP24 PROPELLER QUANTITY 1 MATERIAL GLASS REINFORCED ACRLY STYRENE RESIN DRIVE DIRECT DIAMETER OUTDOOR FAN MOTOR 460 / 18 mm/in…
-
M5MSX 020AR
OUTDOOR UNIT INDOOR UNIT M5WMX 010GR TYPE 1 QUANTITY INDOOR FAN INDOOR FAN MOTOR DRIVE DIRECT DIAMETER mm/in 87 / 3.4 LENGTH mm/in 636 / 25.0 INDUCTION TYPE 1 Q'TY INDEX OF PROTECTION (IP) IP24 PROPELLER FAN QUANTITY 1 MATERIAL GLASS REINFORCED ACRLY STYRENE RESIN DRIVE DIRECT DIAMETER OUTDOOR FAN…
-
OUTDOOR UNIT
M5MSX 025AR INDOOR UNIT M5WMX 010GR TYPE QUANTITY INDOOR FAN INDOOR FAN MOTOR M5WMX 015GR ANTI FUNGUS CROSS FLOW FAN 1 MATERIAL 1 ACRYLO NITRILE STYRENE DRIVE DIRECT DIAMETER mm/in 87 / 3.4 LENGTH mm/in 636 / 25.0 INDUCTION TYPE 1 Q'TY INDEX OF PROTECTION (IP) IP24 TYPE OUTDOOR FAN PROPELLER…
-
OUTDOOR UNIT
M5MSX 025AR INDOOR UNIT M5WMX 020GR TYPE INDOOR FAN INDOOR FAN MOTOR ANTI FUNGUS CROSS FLOW FAN QUANTITY 1 MATERIAL ACRYLO NITRILE STYRENE DRIVE DIRECT DIAMETER mm/in 87 / 3.4 LENGTH mm/in 636 / 25.0 TYPE INDUCTION Q'TY 1 INDEX OF PROTECTION (IP) IP24 TYPE OUTDOOR FAN PROPELLER QUANTITY 1 MATERIAL…
-
M5MSX 030AR
OUTDOOR UNIT M5WMX 010GR INDOOR UNIT TYPE INDOOR FAN MOTOR 1 DIRECT DRIVE DIAMETER mm/in 87 / 3.4 LENGTH mm/in 636 / 25.0 TYPE INDUCTION 1 Q'TY INDEX OF PROTECTION (IP) IP24 PROPELLER QUANTITY 1 MATERIAL GLASS REINFORCED ACRLY STYRENE RESIN DIRECT DRIVE DIAMETER OUTDOOR FAN MOTOR 460 / 18 mm/in TYPE…
-
Performance Data
Capacity Rating Heating Cooling CONDITION Specifications for M5MSX020A/AR with M5WMX-G/GR INDOOR OPERATING UNIT NOMINAL COOLING CAPACITY INPUT RUNNING TOTAL POWER CURRENT INDIVIDUAL INDOOR BTU/h kcal/h KW (W) (A) A (BTU/h) B (BTU/h) RATED RATED RATED (MAX) RATED (MAX) RATED (MAX) RATED (MAX) RATED…
-
Heating
Cooling CONDITION Specifications for M5MSX025A/AR with M5WMX-G/GR INDOOR OPERATING NOMINAL COOLING CAPACITY INDIVIDUAL INDOOR TOTAL BTU/h kcal/h INPUT RUNNING POWER CURRENT (W) KW (A) A B C RATED RATED RATED RATED (MAX) RATED (MAX) RATED (MAX) RATED (MAX) RATED 10 9000 - - 9000 (10000) 2268 (2520)…
-
Heating
Cooling CONDITION Specifications for M5MSX030A/AR with M5WMX-G/GR NOMINAL COOLING CAPACITY INDOOR OPERATING UNIT (M5WMX-G/GR) INDIVIDUAL INDOOR TOTAL BTU/h kcal/h INPUT RUNNING POWER CURRENT KW (W) (A) A B C C RATED RATED RATED RATED RATED (MAX) RATED (MAX) RATED (MAX) RATED (MAX) RATED 10 9500…
-
Dimensional Data
-
Outdoor Unit
-
таблицы и схемы — в просмотре
-
Electrical Data
Electrical Data - Cooling Only MODEL OUTDOOR UNIT M5MSX 020A M5WMX 010G INDOOR UNIT M5WMX 015G INSULATION GRADE POWER SOURCE INDOOR MOTOR E 230 / 1 / 50 V/Ph/Hz RATED INPUT POWER W 38 RATED RUNNING CURRENT A 0.19 MOTOR OUTPUT W 40 0.20 17 POLES 4P INSULATION GRADE POWER SOURCE OUTDOOR MOTOR RATED…
-
OUTDOOR UNIT
M5MSX 025A INDOOR UNIT M5WMX 020G INSULATION GRADE POWER SOURCE INDOOR MOTOR E 230 / 1 / 50 V/Ph/Hz RATED INPUT POWER W 60 RATED RUNNING CURRENT A 0.31 MOTOR OUTPUT W 40 POLES 4P INSULATION GRADE POWER SOURCE OUTDOOR MOTOR RATED INPUT POWER B 230 / 1 / 50 V/Ph/Hz W 140 RATED RUNNING CURRENT A 0.58…
-
Electrical Data - HeatPump
MODEL M5MSX 025AR OUTDOOR UNIT INSULATION GRADE POWER SOURCE INDOOR MOTOR E W 38 RATED RUNNING CURRENT A 0.19 MOTOR OUTPUT W POLES 40 0.20 17 4P INSULATION GRADE B V/Ph/Hz OUTDOOR MOTOR RATED INPUT POWER 230 / 1 / 50 W 140 RATED RUNNING CURRENT A 0.58 MOTOR OUTPUT W 80 V/Ph/Hz 0-300/3/0-100 µF…
-
OUTDOOR UNIT
M5MSX030A M5WMX 010G INDOOR UNIT INSULATION GRADE POWER SOURCE INDOOR MOTOR M5WMX 020G E 230 / 1 / 50 V/Ph/Hz RATED INPUT POWER W 38 RATED RUNNING CURRENT A 0.19 40 0.20 0.31 MOTOR OUTPUT W POLES 60 4P INSULATION GRADE POWER SOURCE B 230 / 1 / 50 V/Ph/Hz OUTDOOR MOTOR RATED INPUT POWER W 170 RATED…
-
Wiring Diagrams
Indoor Unit Model : M5MSX 020AR 52
-
Servicing and Maintenance
Service Parts Maintenance Procedures Period 1. Remove any dust adhering to the filter by using a vacuum At least once every 2 weeks. More frequently if necessary. cleaner or wash in lukewarm water (below 40°C) with a neutral Indoor air filter cleaning detergent. 2. Rinse the filter well and dry…
-
Troubleshooting
If there is any malfunction of the air conditioner unit detected, please sitch off the main power supply immediately before proceeding with the following troubleshooting procedures as safety precautions. The following are some common fault conditions and simple troubleshooting tips. If encounter any…
-
Normal Running Mode condition
If the air conditioner unit has no faulty indications and the compressor is running at normal mode, the outdoor P.C. Board’s LED indication will blink at a slower pace. The table below shows the significant meaning of different running mode and limitation for this air conditioner unit. One must not…
-
Troubleshooting Progress
If the air conditioner is not operating normally, One should follow the troubleshooting steps as stated in the flow chart below . Keep the Main Power Supply ON Open up the Outdoor Unit’s Top Panel or Service Panel Note: DO NOT TOUCH ANY OF THE WIRES OR CONNECTIONS IN THE CONTROL BOX Notice the RED…
-
Check Point (3) – IPM Board
Step-by-step troubleshooting guide for identifying IPM Board error. Check Point (3) Check IPM Board Use Multi Meter Check Connectivity Between +ve and U, V and W Terminals Check DC Voltage Input ~300Vdc DC Voltage ~300Vdc? No Check Wiring & Connection Short? Yes Change IPM Board Yes Change IPM Board…
-
Exploded View and Parts List
-
Products manufactured in an ISO certified facility
This document contains the most current product information as of this printing. For the most up-to-date product information, please go to www.mcquay.com. © 2008 McQuay International +1 (800) 432-1342 www.mcquay.com