Инструкции на Наружные водоохлаждаемые блоки VRF-системы V4+ (сервис мануалы)
Наружные блоки системы VRF V4+ с жидкостным охлаждением конденсатора. Часть 1. Общая информация. Сервис мануал.
Смотрите также: Коды ошибок: 22 кода →
Загружаем документ…
Текст инструкции
-
1. Midea Product Development History
In 1999, Midea cooperated with Toshiba, produced the first AC Inverter VRF. In 2001, Midea produced the first VRF in Air-conditioning industry. In 2002, Midea developed the first AC Inverter VRF and D series VRF in China. In 2003, Midea completed the 2nd D series and 2nd V series VRF. In 2005, Midea…
-
contribute to higher IPLV greatly. The highest IPLV can reach up to 5.9
3.2.1 High efficiency DC inverter compressor, saving power 25% All series of 8HP, 10HP and 12HP adopt one DC inverter compressor each. With DC inverter compressors, V4 Plus W Series offers increases energy efficiency by 25%. The A/C load ratio of building is 30%-75%, the area use ratio is 55%, most…
-
3.2.2 High efficiency double-pipe heat exchanger
With the innovative designed double-pipe heat exchange technology, the water quality required is low. The water side has large circulation area, and it is not easy to get stuck, higher reliability, easy to clean and maintenance. 3.2.3 Wide side heat recovery In the modern large-scale buildings, the…
-
3.3.3 Long piping length
With the refrigerant piping system, total length of refrigerant pipe can reach up to 300m, and maximum piping actual length of 120m and drop height between indoor unit and main unit of 50m is available. Max. pressure of water side can be as high as 1.96 Mpa(200m height difference), making its design…
-
When the slave 1 failed
and came into standby state, the left module can still work. 3.5.3 Dynamic gas balance technology Dynamic vector balance technology, no need to install gas balance pipe: • High-precision pressure sensor monitors the system pressure on time and transfers the data to master unit • Master unit sends…
-
3.5.5 Oil return technology
Centrifugal oil separator can be up to over 99% separating efficiency, which in time and efficiently send the oil to compressors to ensure compressor oil volume. System auto back oil design can complete through PC core to send oil back instruction by system running time and state. The accumulator is…
-
3.6.4 Super Wiring
It is possible to enable the shared use of the wiring between indoor & main units, as well the centralized control. Hence make it easy for the user to retrofit the existing system with a centralized control, by simply connecting it to the main units. • PQE & XYE, just only one group of communication…
-
4 Model Lineup
Main units (Combination Unit): 8, 10, 12 HP 16 ,18 ,20, 22, 24 HP 26, 28, 30, 32, 34, 36 HP 5 Units Combination Table Capacity Recommend combination Model (HP) 8(HP) 10(HP) 12(HP) 8 MDVS-252(8)W/DRN1 10 MDVS-280(10)W/DRN1 12 MDVS-335(12)W/DRN1 16 MDVS-450(16)W/DRN1 18 MDVS-532(18)W/DRN1 20…
-
6 Capacity Range of Indoor Units
Power supply of all the indoor units is 1 phase, 220-240V, 50Hz Capacity (kW) 2.2 2.8 3.6 4.5 5.6 7.1 11.2 12.5 1365 1535 1911 Ton 0.6 0.8 1 1.3 1.6 2 2.3 2.6 2.9 3.2 3.5 4 5 5.7 7.1 8 11 12.3 15.4 HP 0.8 1 1.25 1.6 2 2.5 2.8 3.2 3.6 4 4.4 15.7 19.6 INDEX √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √…
-
7 External Appearance and model names of Indoor Units
-
Wall-mounted S Type
-
8 Nomenclature
1.1 Main unit: MDV S – 252 (8) W / D R N1 Refrigerant type N1:R410A Omit for R22 Power Supply R: 380~415V, 50Hz, 3N Inverter Type D:DC Inverter Omit for AC Inverter Main unit Rated Capacity (HP), (only for combinable type) Cooling Capacity (×100W) Water source type Midea VRF 1.2 Indoor unit: MDV – D…
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.
Другие файлы документа
- Наружные блоки системы VRF V4+ с жидкостным охлаждением конденсатора (R410a V4 Plus W 50Hz). Часть 2. Рекомендации по подбору. Сервис мануал.PDF · 469.15 Kb
- Наружные блоки системы VRF V4+ с жидкостным охлаждением конденсатора (R410a V4 Plus W 50Hz). Часть 3. Спецификация и производительность. Сервис ману…PDF · 1.88 Mb
- Наружные блоки системы VRF V4+ с жидкостным охлаждением конденсатора (R410a DC Inverter V4 Plus W 50Hz). Часть 4. Установка. Сервис мануал.PDF · 1.45 Mb
- Наружные блоки системы VRF V4+ с жидкостным охлаждением конденсатора (R410a DC Inverter V4 Plus W 50Hz). Часть 5. Устранение неисправностей. Сервис…PDF · 988.22 Kb
- Наружные блоки системы VRF V4+ с жидкостным охлаждением конденсатора (R410a DC Inverter V4 Plus W 50Hz). Часть 6. Система управления. Сервис мануал.PDF · 1007.84 Kb