Насосы для бассейнов с регулируемой скоростью и интеллектуальным управлением бассейном Hayward серии VS Omni HL32950VVSP, HL32900VSP, HL26720VSP, HL23520VSP, HL23510VSP. Руководство по установке.
Смотрите также: Руководство по эксплуатации →
Загружаем документ…
Текст инструкции
-
FCC Statement
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications…
-
Before you Begin
What’s Included Check that the following components have been included in your package: • • • • • • • • VS Omni Hub Control Pad Smart Relay 2 Temperature Sensors Variable Speed Pump (VSP) 15 ft, 3 conductor (red, black and bare wire) communication cable to connect Hub to VSP 2 Wiring Whips - 6 ft…
-
Overview
The Hayward VS Omni is a web enabled pool automation control with a convenient touchscreen interface. Because it's packaged with a high efficiency variable speed pool filter pump, the VS Omni is ideal for both retrofit and new pool/spa installations. Automatically and remotely control pumps, a…
-
Control Pad
The Control Pad is weather resistant and comes with a 15 ft cord. Its resistive touch screen with flip down cover is designed to function year round directly in the elements. Because it plugs into the Hub, it should be mounted close by, but in a location that is convenient for the user to…
-
Installation
Installation Steps DANGER of Death, Injury or Property Damage if procedure not followed. Power wiring must be shut off before attempting to install the VS Omni. The VS Omni is designed to be mounted outdoors at the pool pad. Both the Hub and the Control Pad are water resistant and can be left out…
-
Mounting the Equipment
VS Omni Hub The Hub is contained in a raintight enclosure that is suitable for outdoor mounting. It must be mounted a minimum of 6 ft (2 meters) horizontal distance from the pool/spa (or more, if local codes require). The Hub is designed to mount vertically with the knockouts facing downward. Do not…
-
Smart Relay
The Smart Relay is packaged with a single gang electrical box but can also be used with any existing comparable standard electrical box with a minimum volume of 16.2 in3. If using 115 VAC, make sure that there is a Neutral line inside the box before installation. If not, you must run a separate…
-
Temperature Sensors
Water Sensor This sensor is used to measure the pool/spa temperature and is installed in the filtration plumbing after the filter but before either the solar or conventionally fueled heaters. 1. 2. 3. Drill a 3/8” (10mm) diameter hole in the PVC piping and remove all chips and burrs. Insert sensor…
-
Electrical Wiring
The Hub requires both high and low voltage connections. Always: - Ensure that Power is disconnected prior to performing any wiring - Follow all local and NEC (CEC if applicable) codes - Use copper conductors only A dedicated channel on the right side of the Hub has been provided for all low voltage…
-
High Voltage Wiring
Hub Input Power The Hub requires a constant 115 VAC or 230 VAC input power to operate. A wiring harness is included and will plug into the input power connector shown on page 10. Wire the harness according to the diagram below. L2 N L1 L1 230 VAC 115 VAC For easy installation, if replacing an…
-
If replacing a 115 VAC pump, you can disconnect power at the pump and use it to power the Hub
only. The new variable speed pump however, requires 230 VAC which will have to be run separately. Refer to the included pump manual for input power wiring. 115 VAC Disconnect from existing 115 VAC pump Neutral L1 Connect 115 VAC to Hub only and run 230 VAC separately to the new VSP Ground If using…
-
Smart Relay Load Wiring
A Smart Relay can be used to control either 115 or 230 VAC pool equipment. The relay is double pole (makes/breaks both “legs” of 230V circuits or one "leg" of 115V circuits). Refer to the diagram below for wire connections. Use the included Wiring Whip if the supplied electrical box will be mounted…
-
Smart Relays
Like VSPs, Smart Relays rely on communication from the Hub. Their 4 conductor cable is wired to the same connector as a VSP. Wire the cable as shown below. Up to two Smart Relays can be controlled by the VS Omni. In addition to communication wiring, the Smart Relay will be wired to high voltage pool…
-
Pool/Spa Sensor
Push on lever Air Sensor Insert wire here Optional Solar Sensor or External Input Switch External Input Switch If solar heating won't be used, a SPST external switch/device can be connected to this input. This normally open or normally closed on/off external device provides a means to turn the…
-
Control Pad
The Control Pad has a 15 ft cable with a connector that plugs directly into the Hub as shown on page 10. Note that there are rubber plugs covering USB port and Ethernet port on the bottom of the Control Pad. The ethernet port is available for those that desire a wired connection to their access…
-
Laars Heaters
1. 2. 3. 4. 5. Turn power off to heater. Remove factory jumper from terminal block. Wire Hub to the heater as shown. Ensure toggle switch is in the ON position. Set heater thermostats to maximum position. to limit switches remove jumper white white Fusible Link Hayward Pre-2007 Heaters Refer to the…
-
BYPASS
ºC ON ºF OFF Dipswitch located on heater circuit board PK W R BK R Terminal block located at electrical junction box Do not remove jumper Hayward 2007-Current Heaters Refer to the instructions in the heater manual for “2-wire Remote Thermostat” operation under “Remote Control Connections” and the…
-
Pentair/Purex/MiniMax
1. 2. 3. 4. Turn power off to heater. Remove factory installed jumper from the “Ext Switch” connector. Wire Hub to the “Ext Switch” connector as shown below. The wires to the Hub must be separated from any line voltage wires. Failure to follow these instructions may cause erratic operation of the…
-
Black
Orange Stripe Orange Black Stripe Yellow/Black P7 RAYPAK RP2100 STA-RITE Heater 1. Turn power off to heater. 2. Remove upper jacket and open the control box. 3. Remove the jumper for the “fireman’s switch. 4. Wire to the Hub using wire rated for 105°C minimum. Transformer Fireman’s Switch Operating…
-
Home Router
Connection to the web is optional. If web enabled devices such as PCs, laptops, tablets or phones will be used to access the VS Omni, an ethernet or wireless connection must be made to the home router. For wireless connections, refer to the Configuration section of this manual. For ethernet…
-
System Startup
After confirming that all wiring has been performed according to NEC and local codes and that the Hub is properly grounded, apply power to the VS Omni. The VS Omni will take about 30 seconds to fully start. Firmware Upgrade The VS Omni's firmware is the basic operating system that runs the unit. The…
-
About the Configuration Wizard
The VS Omni Configuration Wizard will ask you general questions relating to your pool or spa and specific questions about connected pool equipment. Because this process may take some time, do not begin to configure the VS Omni unless you can dedicate at least 15 minutes or more. Configuring the VS…
-
Done - Touch this button to complete your selection
Cancel - Touch this button to cancel your selection. Advance - Touch this button to advance to the next screen. Back - Touch this button to return to the previous screen. Add - Touch this button to add an item Delete - Touch this button to delete a highlighted item. After being prompted to make a…
-
Pre-Programmed Configuration Wizard Guide
As you progress through the Configuration Wizard, refer to the following information to help answer questions and make selections. Connect to Home Network - The first thing you will do in the Configuration Wizard is connect to you home network. Refer to the “Connect to Home Network” section on page…
-
What type of heater? Select the type of heater that is connected to the VS Omni. Solar heating is not an option for a Typical configuration only Heat Pump and Gas are available. Would you like to add a relay controlled accessory? Select whether or not you would like to configure a relay controlled…
-
Advanced Configuration Wizard Guide
As you progress through the Configuration Wizard, refer to the following information to help answer questions and make selections. Be aware that you may be asked to configure options/features that the VS Omni does not support. If unclear, refer to the "Features" section on page 4 to determine the…
-
with the first Body of Water, you’ll follow the same instructions for the second Body of Water, if previously selected. Configured equipment like a VSP and heater will be shared among both. What is the Body of Water type? Select the type of Body of Water that you would like to configure. The choices…
-
Freeze Protect Temperature? Select the temperature to be used for freeze protection
Temperature is adjustable from 33ºF-42ºF (1ºC-6ºC). 38ºF (3ºC) is default. This threshold will be used for all outputs that have freeze protection enabled. Freeze Protect Speed? For two speed pumps only, select 50% or 100%. If VSP is selected: Which Hayward Unique Address? If using a VSP, you’ll be…
-
Freeze Protect Temperature? Select the temperature to be used for freeze
protection. Temperature is adjustable from 33ºF-42ºF (1ºC-6ºC). 38ºF (3ºC) is default. This threshold will be used for all outputs that have freeze protection enabled. Freeze Protect Speed? This is the speed of the pump while freeze protection is active. Select the desired pump speed %. NOTE: this…
-
start. If the priority heater meets the demand within this time frame,
the next heater will not be used. Note that a time interval setting of “0” will eliminate priority and always run both heaters at the same time. Minimum Operation Speed? For variable speed pumps, select the lowest pump speed that is allowed while heating. Set a speed that will ensure that there will…
-
mation), then advance. The relay should now be shown in the box
Advance to the next screen to continue solar heater configuration. Does the Solar Heater Have a Valve? Select whether the solar heating system has a diverter valve to route pool/spa water through the solar collectors. If so, the VS Omni will rotate this valve when the pool temperature is below the…
-
Does Cleaner Have a Pump? Select whether the cleaner has a dedicated pump. If so,
the VS Omni will turn this pump on when the cleaner is scheduled to run. If Yes is selected: What Type? Select the type of pump used. The choices are Single Speed, Two Speed and VSP. If single speed or two speed pump is selected: Which Relay is it Wired to? If using a single speed or two speed pump…
-
Would you like your valve(s) to cycle On and Off at a set interval? If you
would like the cleaner valve(s) to cycle to a set interval while cleaning, select Yes. Set the interval on the next screen. Would You Like to Enable Priming? Select whether you want the pump to prime when turned on. This will turn the pump on at high speed for a set duration to establish normal…
-
feature pump, you’ll be asked what is the Hayward Unique Address
(HUA). If a value is already shown in the box, advance to the next screen. If no value is shown, selecting the box will bring you to a table showing all detected devices. Select the proper HUA from the table and touch the Done button. If unsure of the HUA, refer to the pump’s manual for instructions…
-
Do You Want to Configure Any Lights? Select yes if you are using any type of lights. The options
are UCL (14V), CL4.0 (115V), CL2.5 (14V), Incandescent, and Other. Note that the VS Omni can only support ColorLogic lights in Standalone mode using its high voltage relays. If Yes is selected: What Kind of Lights? Touch the box to select the type of lights that will be used. The options are UCL…
-
Which Hayward Unique Address? If using a VSP for your accessory pump, you’ll be asked what is the Hayward Unique Address (HUA). If a value is already shown in the box, advance to the next screen. If no value is shown, selecting the box will bring you to a table showing all detected devices. Select…
-
Do You Have an Air Temperature Sensor? Select whether there is an air temperature sensor wired
to the VS Omni. If Yes is selected: Where is the Sensor Wired? Touching the box will bring you to a table showing all detected sensors connections. Select the sensor connection used for the air sensor (typically SENS2) and touch the Done button. The sensor connection should now be shown in the box…
-
Name the Group of Lights - Touch the box and use the keyboard to name the lights
How Many Relays are Lights Wired to? Select the number of relays used by the lights. Which Relay is it Wired to? Touching the box(es) will bring you to a table showing all detected relays. Select the relay(s) that are connected to the lights and touch the Done button. The relay(s) should now be…
-
on unless Equipment A is on. If both are running and Equipment A is turned off, Equipment B will turn off as well. Equipment B can be controlled independently as long as Equipment A is on. If Equipment A is on, Equipment B can not be on - Equipment B will not turn on unless Equipment A is off. If…
-
If the Flow Switch detects flow, the Equipment is forced on - The Equipment is always on as long as the Flow Switch detects flow. Once the Flow Switch detects no flow, the Equipment will turn off. The Equipment cannot be controlled independently. If the Flow Switch detects flow, the Equipment is…
-
ment will remain off until the External Input becomes open again. The Equipment cannot be controlled independently. Select Equipment - After selecting the desired interlock statement, use the buttons labeled “External Input” and “Equipment” located below the interlock statement to choose the…
-
will remain off until the Temperature falls back below the set-point. The Equipment cannot be controlled independently. Select Equipment - After selecting the desired interlock statement, use the buttons labeled “Temp. Sensor”, “Temperature” and “Equipment” located below the interlock statement to…
-
Save - Touch this button to save the configuration edit. This button only appears on the
Quick Edit Home screen. Cancel - Touch this button to cancel any changes made to the configuration and exit Quick Edit. This button only appears on the Quick Edit Home Screen. Home - Touch this button to quickly jump back to the Quick Edit Main Menu Screen to save your changes. This button appears…
-
Speed - Change the minimum and maximum allowed speeds of the Filter Pump
as well as the Low, Medium and High speed settings. This option only appears if the Filter Pump is configured as a variable speed pump. Relay - Select the relay(s) that is wired to the Filter Pump. This option only appears if the Filter Pump is configured as a single speed or 2-speed pump. Off for…
-
Relay - Select the relay that is wired to the heater. This option is only available
if the heater is configured as a heat pump or a gas heater. Min Filter Speed - Select the minimum speed that the Filter Pump will run while the heater is active. This option is only available for 2-speed and VSP pumps. Min Air Temperature - Select the minimum air temperature that the heater will be…
-
Freeze Protect - Select whether you want the cleaner to turn on for Freeze Protection. Also set the Freeze Protect air temperature threshold from this menu. Valve Cycle - Configure the valve cycling time period for the cleaner. This option is only available if the cleaner has an assigned valve.…
-
Delete a Water Feature - From this screen, if you wish to delete a water feature
that is currently configured, select the Delete button on the right of the name of the water feature that you wish to delete. If Standalone Lights is selected: Add Standalone Light - Pressing “Add Standalone Light” from this screen will take you through the full configuration for adding new…
-
Priming - Select whether you want the accessory pump to prime. This option is
only available if the accessory pump is configured as a 2-Speed or VSP. Freeze Protect - Select whether you want the accessory to turn on for Freeze Protection. Also set the Freeze Protect air temperature threshold from this menu. Relay - Select the relay that is wired to the accessory. This option…
-
Relay - Select the relay that the accessory is wired to
Delete an Accessory - From this screen, if you wish to delete an accessory that is currently configured, select the Delete button on the right of the name of the accessory that you wish to delete. NOTE: The system does not allow you to configure a pump or a valve to accessory equipment in the…
-
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
-
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
-
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
-
Control Pad Mounting Template
54 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
-
For further information or consumer
technical support, visit our website at www.hayward.com Hayward is a registered trademark and Hub is a trademark of Hayward Industries, Inc. © 2017 Hayward Industries, Inc. All other trademarks not owned by Hayward are the property of their respective owners. Hayward is not in any way affiliated…
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.