Модели: внутренние блоки RAS-B10S4KVPG-E, RAS-B13S4KVPG-E, RAS-B18S4KVPG-E, наружные RAS-10S4AVPG-E, RAS-13S4AVPG-E, RAS-18S4AVPG-E. Инструкция по монтажу (R32): меры безопасности, комплектующие, установка внутреннего и наружного блоков, электрические подключения, проверка и пробный пуск. Документ на английском языке.
Загружаем документ…
Текст инструкции
-
R32
-
PRECAUTIONS FOR SAFETY
Read the precautions in this manual carefully before operating the unit. This appliance is filled with R32. Warning indications on the air conditioner unit Warning indication CAUTION BURST HAZARD Open the service valves before the operation, otherwise there might be the burst. Description CAUTION…
-
DANGER
• FOR USE BY QUALIFIED PERSONS ONLY. • TURN OFF MAIN POWER SUPPLY BEFORE ATTEMPTING ANY ELECTRICAL WORK. MAKE SURE ALL POWER SWITCHES ARE OFF. FAILURE TO DO SO MAY CAUSE ELECTRIC SHOCK. • CONNECT THE CONNECTING CABLE CORRECTLY. IF THE CONNECTING CABLE IS CONNECTED WRONGLY, ELECTRIC PARTS MAY BE…
-
• Do not use any refrigerant different from the one specified for complement or
replacement. Otherwise, abnormally high pressure may be generated in the refrigeration cycle, which may result in a failure or explosion of the product or an injury to your body. • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. •…
-
CAUTION
• Exposure of unit to water or other moisture before installation could result in electric shock. Do not store it in a wet basement or expose to rain or water. • After unpacking the unit, examine it carefully for possible damage. • Do not install the unit at place where leakage of flammable gas may…
-
ACCESSORY AND INSTALLATION PARTS
Indoor Unit No. Part name No. 1 Part name 2 Installation plate × 1 Wireless remote controller × Battery × 2 Remote controller holder × Ultra pure filter × 2 Mounting screw × Screw × 2 Flat head wood screw × 2 9 ! Owner’s Manual × 1 Installation Manual × 1 Outdoor Unit No. Part name No. " Part name #…
-
INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
66 mm or more For the rear left and bottom left piping Hook Mounting screw 6 Wall Hook 1 Installation plate 300 m m or m Cut out a piece of SPACER from indoor unit packaging box, roll it and insert between the indoor unit and wall to tilt the indoor unit for better operation. ore 300 mm or mor e…
-
INDOOR UNIT
Mounting the installation plate Recommended mounting screw positions Hook CAUTION Pipe hole • Direct sunlight to the indoor unit’s wireless receiver should be avoided. • The microprocessor in the indoor unit should not be too close to RF noise sources. (For details, see the Owner’s Manual.) Thread…
-
• Rear right
When the installation plate is directly mounted on the wall • Rear left Drain hose 1. Securely fit the installation plate onto the wall by screwing it in the upper and lower parts to hook up the indoor unit. 2. To mount the installation plate on a concrete wall with anchor bolts, use the anchor bolt…
-
How to fix the drain hose
• Cut off the pipe exist from inside of Front panel using a coping saw or an equivalent tool. • The plastic burrs from the cutting process should be removed with a half round file or an equivalent tool. • To install the drain hose, insert the drain hose firmly until the connection part contacts with…
-
Left-hand connection with piping
Indoor Unit Fixing • Bend the connecting pipe so that it is laid within 43 mm above the wall surface. If the connecting pipe is laid exceeding 43 mm above the wall surface, the indoor unit may unstably be set on the wall. • When bending the connecting pipe, make sure to use a spring bender so as not…
-
How to remove the air inlet grille
Drainage 1. Be careful open the air inlet grille until arm touch the stopper of the front panel. 2. Push arms on left and right side to outward direction then pull toward you to remove front panel. 1. Run the drain hose sloped downwards. Front panel NOTE • The hole should be made at a slight…
-
OUTDOOR UNIT
Precautions about Installation in Regions with Snowfall and Cold Temperatures Installation Place • A place which provides the spaces around the outdoor unit as shown in the diagram. • A place which can bear the weight of the outdoor unit and does not allow an increase in noise level and vibration. •…
-
Refrigerant Piping Connection
Draining the Water • Holes are provided on the base plate of the outdoor unit to ensure that the defrost water produced during heating operations is drained off efficiently. If a centralized drain is required when installing the unit on a balcony or wall, follow the steps below to drain off the…
-
Packed valve handling precautions
Evacuating • Open the valve stem all the way out, but do not try to open it beyond the stopper. After the piping has been connected to the indoor unit, you can perform the air purge together at once. AIR PURGE Evacuate the air in the connecting pipes and in the indoor unit using a vacuum pump. Do…
-
ELECTRICAL WORKS
Model RAS-B10S4KVPG-E RAS-B13S4KVPG-E RAS-B18S4KVPG-E 50 Hz, 220 – 240 V Single phase Power source Maximum running current 8.50 A 9.95 A 12.00 A Circuit breaker rating 15 A 15 A 20 A Power supply cable H07RN-F or 60245 IEC66 (1.25 mm2 or more) H07RN-F or 60245 IEC66 (1.5 mm2 or more) H07RN-F or…
-
In Case of Indoor Unit Connect With 1:1 Outdoor Unit
The power supply can be selected to connect to indoor unit or outdoor unit. Choose proper way and connect the power supply and connecting cable by follow the instruction as following. Power Supply Input at Indoor Unit Terminal Block (Recommend) Indoor Unit Stripping length of the power supply cable…
-
Power supply input Wiring Diagram for 1:1 Outdoor Unit
Power supply input at Indoor Terminal Block (Recommend) Indoor Terminal Block Power supply input Outdoor Terminal Block Power supply input at Outdoor Terminal Block (Optional) Indoor Terminal Block Outdoor Terminal Block Power supply input CAUTION 1. The power supply must be same as the rated of air…
-
In Case of Indoor Unit Connect With Inverter Multi System (IMS)
Power Supply Input at Outdoor Unit Terminal Block 10 mm 3 2 Earth line 1 10 mm 40 mm 50 mm 30 mm 10 mm Earth line Terminal block (L N 1 2 3) 10 mm Stripping length of the connecting cable Connecting cable connect to 30 mm 10 mm Connecting cable Outdoor Unit 40 mm Indoor Unit Earth line 10 mm 70 mm…
-
OTHERS
Test Operation Gas Leak Test To switch the TEST RUN (COOL) mode, press [RESET] button for 10 seconds. (The beeper will make a short beep.) Check places for the indoor unit. OPERATION / RESET Button Check places for the outdoor unit. Auto Restart Function Setting • Check the flare nut connections for…
-
APPENDIX
Work instructions The existing R22 and R410A piping can be reused for inverter R32 product installations. WARNING Confirming the existence of scratches or dents on the existing pipes and confirming the reliability of the pipe strength are conventionally referred to the local site. If the specified…
-
INSTALLATION CHECK LIST
Model name After finishing installation work, please check items below and hand this sheet to user to keep it in a safe place together with Owner and Installation Manuals Check date Checked by Note : Please put a mark " " in the box you checked. Piping work Check items Symptom Check Connecting pipes…
Схемы, таблицы и рисунки — в просмотре документа выше. Клик по номеру страницы открывает её в просмотре.
Другие файлы документа
- Модели: RAS-B10S4KVDG-E, RAS-B13S4KVDG-E, RAS-B18S4KVDG-E, RAS-10…18S4AVPG-E. Сервисная инструкция (SVM-24002, февраль 2024): спецификации, электрич…PDF · 20.11 Mb
- Инженерные данные (Engineering Data Book TCTC-E24-RES002-2, ред. 02 от 10.06.2024) на внутренние блоки RAS-B10…18S4KVPG/KVDG-E и наружные RAS-10…18S…PDF · 4.39 Mb
- Модели: RAS-B10…18S4KV*G-E. Руководство пользователя (R32): меры безопасности, пульт управления, режимы работы, уход и обслуживание. Документ на анг…PDF · 6.42 Mb