User Notice
◆ When operating, the entire capacity of the cooperating indoor unit should be not larger than 150% of outdoor unit. Otherwise, it will cause the shortage of cooling (heating) capacity. ◆ A Breaker(or fuse) need to be installed in every indoor unit, and the capacity should in according with indoor…
-
Ⅱ Wireless Remote Controller YT1F
Notes: ① . Be sure that there are no obstructions between the receiver and the remote controller; ② . Do not drop or throw the remote controller; ③ . Do not let any liquid into the remote controller and expose the remote controller to direct sunlight or any place where is very hot. ④ . This is a…
-
4) FAN
Auto, Low, Middle, or High fan speed can circularly selected by pressing this button. After powered on, the default is Auto speed. Under Dehumidifying mode, only Low fan speed is available. 5) CLOCK The clock can be set up by pressing this button, with the symbol displayed and blinking. In such a…
-
This kind of remoter controller is universal. And the three swing statuses of
are the same as that of . If the swing function is deactivated when the air guide louver is swing up and down, it will stop at the current position. indicates that the air guide louver swings up and down among all five positions. 13) AIR ( ) AIR ON or Air OFF can be selected by pressing this button.…
-
② . BLOW OFF: When press the ON/OFF button to turn off the unit, the whole unit will be stopped
completely. b. About AFTERHEAT BLOW Under the Heat mode or Auto Heat mode, if the unit is turned off, the compressor and outdoor fan will stop running immediately and the upper and lower guide board will rotate to the horizontal position, while the indoor fan will still run at the low fan speed.…
-
Ⅰ Wired Controller XK19
1 Wired Controller XK19 It is optional for the cassette type, wall-mounted, and floor ceiling indoor units. 1.1 Outside View of the Wired Controller Fig.1 Outside View of the Wired Controller 1.2 LCD of the Wired Controller Fig.2 LCD of the Wired Controller 1
-
1.3 Introduction to the Symbols on LCD
Table 1 No. Symbols Description 1 Swing function. 2 Sleep function (3 types: sleep 1,sleep2 and sleep 3). 3 Running modes of the indoor unit (Cooling, Dry, Fan and Heating). 4 Defrosting function for the outdoor unit. 5 Gate-control function (this function is yet unavailable for this unit). 6 Lock…
-
2.2 Function of the Buttons
Table 2 No. Name 1 Enter/cancel 2 ▲ 6 ▼ Function ① Function selection and cancellation. ② Press it for 5s to examine the outdoor ambient temperature. ① Running temperature setting of the indoor unit, range:16 ~ 30℃ . ② Timer setting, range:0.5-24 hr. ③ Switchover between quiet/auto quiet or among…
-
3.3 Temperature Setting
Press ▲or ▼ to increase/decrease the preset temperature. If press either of them continuously, the temperature will be increased or decreased by 1℃ every 0.5s,as shown in Fig.6. In the Cooling, Dry or Heating mode, the temperature setting range is 16℃~ 30℃ . In the Fan mode, the setting temperature…
-
Timer off setting under the “On” state of the unit is shown as Fig.8
Fig. 8 Timer off Setting under the “On” State of the Unit Timer range: 0.5-24hr. Every press of ▲or ▼ will make the set time increased or decreased by 0.5hr. If either of them is pressed continuously, the set time will increase/ decrease by 0.5hr every 0.5s. 3.6 Swing Setting Swing On: Press…
-
Fig. 9 Swing Setting
Note: ① . Sleep, Save, Turbo, Blow or Quiet setting is the same as the Swing setting. ② . After the setting has been done, it has to press the key “Enter/cancel” to back to the setting status or quit automatically five seconds later. 3.7 Sleep Setting Sleep on: Press Function under on state of the…
-
Fig. 10 Sleep Setting
Sleep off is default after power failure and then power recovery, and the sleep functions is unavailable under the fan mode. There are three Sleep modes: Sleep 1, Sleep 2 and Sleep 3. a. Sleep 1 In the Cooling or Dry mode, the temperature will increase by 1℃ after the unit runs under Sleep 1 for 1hr…
-
For example, the temperature in the Heating mode is set at 22 ℃ .Under the mode of Sleep2, the
temperature will decrease by 1 ℃ every 1hr. After it decreases by 2 ℃ in total, i.e. 20 ℃ ,the unit will keep running at 20℃ . c. Sleep 3 Sleep curve setting under Sleep 3(DIY mode) d. Under the mode of Sleep 3, press Timer to enter the Sleep setting. In this case, “1 HOUR” is displayed where the…
-
When the Turbo function is activated, press Function to enter the Turbo setting interface and then press Enter/Cancel to cancel this function. Turbo function setting is as shown in Fig.14. Fig.14 Turbo Setting Notes: ① . When the Turbo function is activated, if the difference between the room…
-
Fig. 15 Saving Setting for Cooling
Save Setting for Heating: Under on state or in the Heating mode of the unit, press Function to enter the Save setting interface and then press ▲or ▼ to adjust upper limited value in the Heating mode. After that, press Enter/Cancel to activate the Save function for heating. The upper initial limited…
-
Fig.16 Save Setting for Heating
Notes: ① . If press Function on the Save setting interface or if there is not any operation for 5s after last button press, the Save setting will be canceled automatically by the system, with memorizing the present setting data. ② . When power is on after the power failure, the Save function will be…
-
Fig.17 E-heater Setting
3.11 Blow Setting Blow function: After the unit is turned off, the water in evaporator of indoor unit will be automatically evaporated to avoid mildew. In the Cooling or Dry mode, press Function till the unit enters the Blow setting interface and then press Enter/Cancel to active this function. When…
-
Fig.18 Blow Setting
Notes: ① . When the Blow function is activated, if turning off the unit by pressing On/Off or by the remote controller, the indoor fan will run at the low fan speed for 10 min, with “BLOW” displayed on the LCD. While, if the Blow function is deactivated, the indoor fan will be turned off directly. ②…
-
Fig.19 Quiet Setting
Notes: ① . When the Quite function is activated, the fan speed is low and un-adjustable. ② . When the Auto Quite function is activated, the unit will run according to the difference between the room temperature and the setting temperature. In this case, the fan speed is adjustable. Difference…
-
Memory recovery: If this function has been set for the wired controller, the wired controller after power failure will resume its original running state upon power recovery. Memory contents: On/Off, Mode, set temperature, set fan speed, Save function and Lock function. c. Enquiry of the Outdoor…
-
Table 3 Meaning of Each Error
Error Code Error High pressure protection E1 Low pressure protection E3 Discharge protection E4 Over-current protection P5 Communication error E6 Indoor water overflow protection E9 Mode conflict E7 Anti-freezing protection E2 Defrosting or oil returning for heating H1 Indoor ambient temperature…
-
Safety Information
Safety Information Please read this manual carefully before use this unit, and operate it correctly according to the guide in this manual. Please take specially note to the meaning of these two marks: Warning!: This mark means that it may cause casualty or badly heart if the operation is incorrect.…
-
Install Of The Cassette Type Indoor Unit
Install Of The Cassette Type Indoor Unit ★ Schematic diagram of installation spaces H >20 Wall surface Wall surface Wall surface ≥1500 ≥1800 ≥1500 Model MC-C24AI unit:mm H 260 Ground surface Fig.1 ★ Select install location of the indoor unit 1. Obstruct should put away from the intake or outlet vent…
-
caused by the unit that is installed by the department that is not special nominated by Nepa spol.s.ro. would not deal with on time by the inconvenience of the business contact. 780( Gaps between hoisting screw rods) 840( Indoor unit) 890*(Ceiling opening) 950( Decorated surface boards ) ★ Dimension…
-
◆ Install the install cardboard on the unit by bolt (3 piece), and fix the angle of the drainage pipe at the outlet vent by bolt. 3 Adjust the unit to the suitable install place. (Refer to the fig.3) 4 Check if the unit is horizontal. ◆ Inner drainage pump and bobber switch are included in the…
-
Smear freeze motoroil
here Median sponge (attachment) (entwine the wiring interface with seal mat) Thread fasten(x4) Torque wrench Heat preservation sheath of liquid inlet tube (attachment) (for liquid tube) Spanner Flare nut Wiring interface Gas collection tube Liquid inlet tube Heat preservation sheath of gas…
-
Sponge(attachment)
Clamp Sponge (gray) Clamp(attachment) Drain hose Below 4mm Fig.7 Drain stepup pipe note ◆ The install height of the drain raising pipe should less than 280mm. ◆ The drain raising pipe should form a right angle with the unit, and distance to unit should not beyond 300mm. Fig.8 Instruction ◆ The slant…
-
Fig.11
★ Electrical wiring Note:The power of the entire indoor unit must be connected in outdoor unit. ◆ About the electrical wiring, please see the circuit diagram attached with the unit. ◆ All the installation of electrical wiring must be done by professional personnel. ◆ Please do take the earthing…
-
Fig.12
★ Install the panel 1. Set the panel to the indoor unit body by matching the position of the swing flap motor of the panel to the piping position of the panel to the piping position of the indoor unit as shown by fig.13. 2. Install the panel ① Install the panel on the indoor unit temporarily. When…
-
Fig.13
Notes: 1. Improper screwing of the screws may cause the troubles shown in fig.14. Air leak Air leak from ceiling Water condensatation, water drop Fig.14 2. If gap still exist between ceiling and decoration panel after tightening the screws, readjust the height of the indoor unit. (As shown in…
-
※ After fixing, be sure no gap left between the ceiling and the panel
3. Wiring of the decoration panel (Fig.16) Connect the joints for swing flap motor lead wire (at 2 places) installed on the panel. At body At body At pane Fig.16 10 At pane
-
Constitutes and Names of Parts of Cassette Type Indoor Unit
MC-C24AI 11
-
Working Temperature Range
Working Temperature Range Indoor side state 12 Outdoor side stae Dry bulb temp. ℃ Wet bulb temp. ℃ Dry bulb temp. ℃ Wet bulb temp. ℃ Rated Cooling Max. cooling Min. cooling — Rated Heating Max. heating 27 — 24 18 Min. heating 20 15 - 15 - 16
-
Operation Method When Meeting An Emergency
When wireless remote controller is lost or damaged, the following method could be adopted to control cassette type indoor unit: ◆ When the unit is turned off, press AUTO button on corner outer cover Ⅱ , then the unit begin operate in cooling with the fan run in high speed. The temp. will be set to…
-
Malfunction Debarring
Warning! ◆ Cut down the main power switch immediately if malfunction (such as smell the burning odor etc.) happened, and then contact service center. If the abnormal state is maintained, the unit may be damaged or electric shock or fire may be happened. ◆ Do not refit the conditioner. Please contact…
-
★ Instruction
If problem still cannot found out after above checking, please contact service center and instruct phenomena and model. ★ The following circumstance are not malfunction “Malfunction” Air conditioner doesn’t Reason Start up unit immediately after turned The overload protects switch makes it off run…
-
Maintenance Method
When air conditioner won’t be used for a long time, please cut off the main power supply of air conditioner. Warning! ◆ Do turn off the unit and cut off the main power supply when cleaning the air conditioner, otherwise electric shock or harm may happen. ◆ It is forbidden to wash air conditioner by…
-
Fig. 20
Fig. 21 ★ Clean air inlet grille 1. Open air inlet grille (the same with the 1st step of Clean Air Filter) 2. Take out air filter (the same with the 2nd step of Clean Air Filter) 3. Take out air inlet grille Open air inlet grille for an angle of 45°, as shown in fig. 21, rise it. 4. Clean Clean it…
-
Function and usage period for air purifying
◆ Could adsorb CO, CO2, benzene, aldehydes and odor of gasoline etc.. ◆ Could adsorb deleterious material that is smaller than 1μm in air, as dust, pollen, bacteria, and virus. ◆ Usage period is 6 months to 1 year. If it is necessary to be changed, purchase new purifier in the nearest special…