WALL MOUNTED TYPE ROOM AIR-CONDITIONER Split system, Air cooled cooling only type ( ) SRK501CENF-L, SRK561CENF-L 93
-
3.1 GENERAL INFORMATION
3.1.1 Specific features The “Mitsubishi Daiya” room air conditioner: SRK series are of split and wall mounted type and the unit consists of indoor unit and outdoor unit with refrigerant precharged in factory. The indoor unit is composed of room air cooling or heating equipment with operation control…
-
SELECTION DATA 3.2.1 Specifications Model SRK501CENF-L (Indoor unit) SRC501CENF-L (Outdoor unit) Model Item Cooling capacity(1) SRK501CENF-L SRC501CENF-L W 4500/4500 Operation data(1) Power source 1 Phase, 220/240V, 50 Hz Cooling input kW 1.78/1.88 Running current (Cooling) A 8.4/8.2 Inrush current…
-
Model SRK561CENF-L (Indoor unit)
SRC561CENF-L (Outdoor unit) Model Item Cooling capacity (1) SRK561CENF-L SRC561CENF-L W 5000/5000 Operation data(1) Power source 1 Phase, 220/240V, 50 Hz Cooling input kW 2.08/2.18 Running current (Cooling) A 10.2/9.53 Inrush current A 44/48 COP (In cooling) 2.40/2.29 Noise level(5) Exterior…
-
lnlet air temperature range Outdoor air temp.˚CD.B. (1) Range of usage & limitations Applicable temp. range JIS-Cooling Indoor air temp.˚CW.B. Note: The chart is the result from the continuous operation under constant air temperature conditions, however, excludes the initial pull-down stage. (2)…
-
Exterior dimensions
(1) Indoor unit Models SRK501CENF-L, 561CENF-L (2) Outdoor unit Models SRC501CENF-L, 561CENF-L 510 87 Unit: mm Oval (M10x4) holes for Anchor bolt 3.2.3 30 70.5 17 25 Drain pipe Lebel model name 475 615 Service valve (Gas) Ø12.7 (1/2˝) Service valve (Liquid) Ø6.35 (1/4˝) 99
-
Piping system Models SRK501CENF-L, 561CENF-L Indoor unit Outdoor unit Flare connecting Service valve (Gas) Cooling cycle Piping (Gas) ø12.7 Room temperature thermistor Heat exchanger Discharge Check joint Accumulator Heat exchanger Heat exchanger thermistor Suction Compressor Capillary tube Piping…
-
ELECTRICAL DATA 3.3.1 Electrical wiring Models SRK501CENF-L, 561CENF-L Outdoor unit Indoor unit Power source 1 Phase 220/240V 50Hz LB BR G 1 BL Y WH BK RD F 250V 3.15A ) ( H I Wireless R-Amp Display Printed circuit board Meaning of marks Color symbol BK Black Symbol BL Blue CC Parts name Symbol…